Sunteți pe pagina 1din 1

Camesa 7/32" H2S 1K22-S75

lb
Cable breaking strength 4800
Max suggested working tension 2400

No. of Inner armor 15


No. of outer armor 15

Inner (lb) 113


Average wire breaking strength
Outer (lb) 246

lb/Kft lb/Km
Air 95 311.7
Cable Weight
Water 80 262.5

Core Resistance 22 ohm/Km


Stretch Coefficient 2.47 ft/Kft/Klb

WP Construction
Outer/Inner
10/2 9/2 8/2 7/2 6/2
Weak Point (lb) 2042 1838 1633 1429 1225

Max Depth (meter) 1365 2143 2921 3699 4478


Gas 1150 1805 2460 3115 3771
Do not consider Inners in strength of WP if the inner OD is smaller than outer OD
Hole fluid is water in calculation, Max depth depend on fluid density
Max Depth = 1000*(2700-WP)/(Cable weight per foot*3.28)
Max Safe pull = 0.5*WP+Cable weight@ stuck point
Weak Point = Armor breaking strength*No. of Armors*0.83

S-ar putea să vă placă și