Method Statement for Application

CRACK INJECTION REPAIR TO


CONCRETE STRUCTURES

Scope:
Injection of dead cracks with low viscosity 2 components epoxy
resin.

The information, and, in particular, the recommendations relating to the application and end-use
of Sika products, are given in good faith based on Sika's current knowledge and experience of
the products when properly stored, handled and applied under normal conditions. In practice,
the differences in materials, substrates and actual site conditions are such that no warranty in
respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either from this information, or from any written
recommendations, or from any other advice offered. The proprietary rights of third parties must
be observed. All orders are accepted subject to our current terms of sale and delivery. Users
should always refer to the most recent issue of the Product Data Sheet for the product
concerned, copies of which will be supplied on request

1/3
Sika(Cambodia)Ltd
62B, Street 432, Toul Tom Poung II - Phnom Penh
Tel 23 2 33 a 23 22 23 6 email: sika@kh.sika.com
I. PREPARATION
14mm holes must be drilled along the crack path between 200 300 mm
centres. The holes must be deep enough to receive the metal pipe slee es
(approx. 20mm)
Insert Sika metal pipe sleeves into all the holes and epoxy into position using
Sikadur 31CF Normal
Clean the concrete surface adjacent to the crack with a wire brush or
sandpaper.
Wipe down the concrete with a clean rag to remove any dust and loosely
adhering particles.
The cleaned surface is then sealed using Sikadur 31CF Normal applied by a spatula or
trowel.

II. CRACK INJECTION


Following the curing of the Sikadur 31CF Normal
(minimum of 12 hours at 30oC) the epoxy injection can commence.
Starting from one side or the lowest point of the crack a Sika nipple is
screwed into the first pipe sleeve and Sikadur 752 injected into the crack until
the epoxy is seen to ooze from the adjacent pipe sleeve, this pipe sleeve is
then sealed with a nipple, continue to inject the current port until refusal
(epoxy resin can not be injected more) and then start the injection of the
adjacent port and so on. This procedure is continued in the sequence
indicated until all have been completed.
Beginning at the first nipple filled, the nipple is removed and checked for
incomplete filling. If any of the pipe sleeves are found to be incompletely filled,
the injection of Sikadur 752 must recommence from the previous pipe sleeve
to the one found incomplete until full and the nipple replaced. This checking
process is continued (without interruption) along the crack until all have been
checked.
After a curing time of 12 hours the sleeve and nipples are trimmed off with an
angle grinder or other suitable equipment.

Sika(Cambodia)Ltd
62B, Street 432, Toul Tom Poung II - Phnom Penh
Tel 23 2 33 a 23 22 23 6 email: sika@kh.sika.com
PUMP

NIPPLE

SLEEVE
SIKADUR 31CF

CONCRETE SIKADUR 752

Further assistance needed please do not hesitate to contact Technical


Department

Sika(Cambodia)Ltd
62B, Street 432, Toul Tom Poung II - Phnom Penh
Tel 23 2 33 a 23 22 23 6 email: sika@kh.sika.com