9 Tier 1, 1999
8
Euro 1 1992
7
Euro 2 1996
NOx g/kWh
6
Tier 2, 2002
5
4
3 Tier 3, 2007
2 Tier 4I, 2011
1
Tier 4 final, 2014
0
0 0.10 0.20 0.30 0.40 0.50 0.60 0.70
PM g/kWh
Tier 4F DC 9
Note: All Engines have SCR
Tier 4F DC 13
Note: All Engines have SCR
Tier 4F DC 16
Note: All Engines have SCR
1. DEF hose
2. Coolant hose
3. Water control valve
4. DEF hose
5. DEF tank
6. Coolant hose
7. NOx Sensor
8. DOC (Diesel Oxidation Catalyst)
9. Exhaust Temperature sensor
10.SCR catalyst
11.NOx sensor
SCR exhaust
Stainless steel piping must be used
V clamp torque
16.23 ft.lb. V clamp torque V clamp torque
22 Nm. 14.75 ft.lb. 14.75 ft.lb.
20 Nm. 20 Nm.
Tier 4i connections
Tier 4F connections
SCR Catalyst
All SCR catalysts have the same diameter 13.7 in. (349mm)
Catalyst length is dependant on engine type
End parts are rotatable
Flow direction is important
T115 T131
The NOx sensors report the NOx levels to the EEC, the EEC uses
this reading to inject the correct amount of DEF into the exhaust.
The sensor is electrically heated, which is controlled by the EEC.
When the exhaust temperature reaches 400°F (205°C) the EEC will
start injecting DEF into the exhaust.
The catalyst has good function above 482°F (250°C)
The optimal function for the catalyst is 572°F (300°C) to 930°F (500°C)
If the exhaust temperature reaches 1020°F (550°C) the engine will
derate to avoid damages to the system.
DEF Tank
All dimensions in mm
1. Inlet, DEF
2. Outlet, DEF
3. Prefilter, DEF
4. Expansion sleeve
5. Overflow valve
6. Port to pump chamber
7. Check valve
If the pressure in the system exceeds 13 bar the relief valve in
the pump will open.
1. Expansion sleeve
2. DEF filter
Level sensor
Temperature sensor
DEF quality sensor
1. Electrical connector
2. DEF inlet
3. DEF outlet
4. Metering nozzle
5. Ventilation
1. Graphite gasket
2. Metering nozzle
The dosing unit opens once per second and the amount of
time that the solenoid valve is open during that second
determines the dosage quantity.
The opening time can vary from 5–95% of 1 second.
The dosing unit also monitors pressure and temperature
and reports this back to the EEC.
When the DEF temperature reaches 18°F (-8°C), the DEF pump
starts to build pressure.