I’m pleased to bring you our first Harmony This news bulletin will help us share the which will be of interest to customers
INFI 90 news bulletin intended for users of news about ABB’s investments in new who have not yet signed up for a service
the ABB Harmony INFI 90 control system. products and software versions for the contract and lack these announcements.
You might wonder why we would start a Harmony INFI 90 control platform.
newsletter now for a control system that We plan to issue at least an annual news
was introduced in the 80s as Network 90. Secondly, we would like to tell you bulletin, packed with valuable information
It is not a marketing oversight, so let me about all upgrade possibilities designed for you. In addition, we encourage your
assure you there are good reasons. to increase the performance of this feedback and invite you to share your
system as well as the seamless, proven interests and comments with us. We are
First, it’s an opportunity to remind that migration possibilities for the HMI based delighted to provide any additional infor-
your Harmony INFI 90 control system on state-of-the-art hardware solutions, mation or advice you may need.
is still being developed and supported both of which can help secure your
by ABB. How can we do that? ABB’s equipment investments. I wish you happy reading.
commitment is the “Evolution without
obsolescence” concept. This keeps your And finally, we want to keep you up-to- Kind regards
control system up-to-date by just pro- date regarding worldwide ABB events Fabio Fargione
vi-ding small steps instead of a total including Harmony INFI 90 technology as Harmony Evolution Manager
replace solution. well as status reports and platform notes, ABB Power Systems Division
Project news Events
Duvha power station is a six unit, coal- The Duvha plant's control system con- from the late 1990s is based on Process
fired power plant operated by the South sists of the ABB Harmony INFI 90 Portal B / Windows 2000.
African electrical utility, Eskom, with a total process control system, with 17 power
installed capacity of 3,600 megawatts conditioning units (PCUs), multi-function After more than 15 years of good opera-
(MW). The plant is located in approxima- processors (MFP), bridge controllers tion the system faced normal component
tely 15 km east of Witbank in Mpumalanga (BRC100) and block I / Os. The original aging, in addition to fast evolution of the
province. human machine interface (HMI) solution plant operating system.
All events are hosted by the Power Generation users themselves and focuson meeting, sharing experiences and
Engineering station upgrades enable new redundancy bridge controller. exchanging best practices. In addition, they are the perfect platform to experience the latest Harmony INFI 90 product
updates and system news by ABB.
The first step was an update of the Har- system, without impacting normal plant
mony engineering to the latest version of
Composer for Harmony applications.
operations. Benefits of If you would like to participate in one of the Power Generation events, please do not hesitate to contact us.
2 The ABB Harmony INFI 90 news bulletin 1 | 15 The ABB Harmony INFI 90 news bulletin 1 | 15 3
Platform news Platform news
ABB control systems Harmony INFI 90 Available life cycle parts services
extends its life cycle support ABB offers a comprehensive range of ABB’s life cycle parts services portfolio ABB ensures that our customers receive
spare parts with short lead times, which meets customers’ needs to minimize the best possible return on their assets
helps minimize downtime if a failure costs and maximize the value of their throughout the entire product life cycle.
Symphony Harmony is a proven process control system used for demanding occurs. investments in ABB equipment.
applications in various industries.
The wide range of Harmony references introduced in 1980 as Network 90, the new generation enhances its predeces-
includes the power generation, chemical, system has gone through several evolu- sors and is backwardly compatible with
Evolution without
Non-active since
Obsolecence to
OIS2 x CVMS
OIU PGP
HMI MCS
OIS4x CNT
PPA
S+ Operations
PCV PPB
Product
Status
Engineering EWS WinTools Composer S+ Engineering
Like its predecessors listed above, Sym- generation and water treatment. as customers continue to upgrade and Composer Harmony 6.1 Active
phony Plus is designed to meet the evolve their installed systems to our lat- Symphony Plus Engineering Active
requirements of plant owners in all geo- Automation Sentinel remains the key est generation offerings.
Network 90 Power System 1999 Obsolete MPSIII
graphic markets and in all types of power program for lifecycle system support
Modular Power System I 2001 Obsolete MPSIII
Modular Power System II 2003 Limited O O O MPSIII
Modular Power System III Active
ABB life cycle policy statement Bridge Controller Active
Multi-Function Processor 2006 Limited O O O BRC410
ABB’s control systems are designed for Harmony Area Controller 2004 Limited O O O HPC800
continuous evolution. It is ABB’s goal to Harmony Rack Controller BRC410 Active
protect our customers’ intellectual invest-
Active Classic Limited Obsolete
Harmony Din Controller HPC800 Active
ment (i.e. application software) beyond
the life cycles of the underlying platform Harmony Block I/O 2003 Limited O O O S800 I/O
products (i.e. hardware and software). Once a product has been removed from It is ABB’s intention to provide support Harmony Rack I/O HR Series Active
active sale, ABB will continue to support for as long as there are significant cus-
Harmony Din I/O SD Series Active
ABB will not “Remove from Active Sale” the product for at least 10 years, al- tomer needs after the “Manufacturing
any product or “family” of products un- though exceptions to this may occur if End” through field service, repair and Harmony with S800 I/O Active
til an equivalent replacement to those components or technologies needed are by making replacement spares (new or Harmony Control Network Active
products is available. no longer provided to ABB. refurbished modules) available.
4 The ABB Harmony INFI 90 news bulletin 1 | 15 The ABB Harmony INFI 90 news bulletin 1 | 15 5
Platform news Platform news
Report
Report
6
Loop Node Mod Type Rev
C
1 15 0 INIIT03 B4
1 16 0 INIIT03 B4 7 8
1 17 0 INIIT03 B4 C C
1 18 0 INIIT03 B4
1 19 2 INICT03 G0
1 20 2 INICT03 G8 PCU = process control unit
1 21 2 INICT03 G3
C = console/computer
1 22 2 INICT03 G9 1 9
1 40 1 INIIT03 B4 PCU C
2 1 0 INNPM01 E5
2 1 2 IMMFP02 G5
2 1 3 IMMFP02 G5
2 2 0 INNPM01 E5 2 3
2 2 2 IMMFP02 G5 PCU PCU
6 The ABB Harmony INFI 90 news bulletin 1 | 15 The ABB Harmony INFI 90 news bulletin 1 | 15 7
Training Center
Training programs for engineers, pro- on-line. We help you to increase the skill in any given situation hence improving
grammers, maintenance and operations level and knowledge of your employees operational efficiency of your assets.
personnel provide up-to-date technical through training assessment programs
expertise for existing and new products, including competence development, cus-
processes, and technology advances. tom courseware and coaching services.
We offer training on-site at ABB training Accurate training will increase your capa-
facilities, locally at your plant site, or bility to respond rapidly and efficiently
8 The ABB Harmony INFI 90 news bulletin 1 | 15 The ABB Harmony INFI 90 news bulletin 1 | 15 9
Contact Contact
ABB Argentina: Daniel Guerrero ABB South Africa: Edith Kikonyogo ABB Indonesia: Homijujung Sihombing
Phone: +54 911 6026 5606 Phone: +27 60 544 6346 Phone: +62 811 213 1513
Email: daniel.guerrero@ar.abb.com Email: Edith.Kikonyogo@za.abb.com Email: homijujung.sihombing@id.abb.com
10 The ABB Harmony INFI 90 news bulletin 1 | 15 The ABB Harmony INFI 90 news bulletin 1 | 15 11
Contact us
Harmony Global Execution Center
06.15
The information in this document is subject to change without notice
Power Systems Division Service
and should not be construed as a commitment by ABB. ABB assumes
Via Enrico Albareto 35, no responsibility for any errors that may appear in this document. In
9AAK10103A1068
16153 Genoa, Italy no event shall ABB be liable for direct, indirect, special, incidental or
Hotline Phone: +39 010 607 37 77 consequential damages of any nature or kind arising from the use
of this document, nor shall ABB be liable for incidental or consequential
Email: gec.harmony@it.abb.com
damages arising from use of any software or hardware described in
this document. This document and parts thereof must not be reproduced
ABB Training Center or copied without written permission from ABB, and the contents thereof
Power System Division Service must not be imparted to a third party nor used for any unauthorized
new.abb.com/power-generation/
power-plant-automation/harmony