Sunteți pe pagina 1din 2

Vertical Heater

Treater

Separation that sets the standard.


Phase separators effectively separate and remove free water from the well stream, but emulsified
water requires the application of heat and demulsifying chemicals for removal. Our field-proven,
Vertical Heater Treaters effectively process inlet well fluids and break those oil/water emulsions
while separating oil, gas, and water.

Plus, pre-engineered, inventoried models are eligible for “Quick Ship” on-demand delivery
because we know that you need equipment on time.

Benefits Features How it Works The heat breaks the emulsion and
• Heat improves separation of oil • Removable firetube and stack Well fluids enter the top section water is released and settles to the
and water • High-efficiency burner and pilot of the separator where an inlet bottom of the treater where it is dis-
• Heat also reduces paraffin buildup assembly diverter deflicts the fluid to the charged to the water storage tank
on instruments, valves and pipes • Temperature controller treater shell
The treated oil rises and exits the
• Mist extractor boosts efficiency • Liquid gauge assemblies
Free gas and solution gas is re- treater at the top of the oil settling
• Pre-assembled unit allows for • Pressure gauge with isolating valve
leased from the liquid and exits the section to the oil storage tank
quick and easy installation • Thermal relief valve
top of the separator
• Oil/water outlet dump valves
• Flame arrestor/burner Oil, water and emulsion flow
• Fuel gas scrubber with high-level through the downcomer pipe
shutoff and drain beneath the firebox
• Fuel gas regulator
For more information call:
(713) 335-6600

productiontechnologies@nov.com nov.com/productiontechnologies
Vertical Heater Treater

Pre-engineered. Field-proven. Quality tested.


Relief Gas
Connection Outlet
Gas
Separating
Section S.S. Wire Mesh
Mist Extractor
16"
Manway
Solid Baffle
Gas Equalizer Ladder
o
Untreated Water Leg
Crude oil Inlet Siphon
Adjustment
Emulsion
Downcomer o
Treated Crude Sight
Upper Water
Oil Out Glass
Leg Section
o

Treated Oil
Stack Oil
Settling Water Dump
Section Connection
o Sight Glass

o Pressure Gauge
Interface Thermometer
Thermostat
o
16"
Water Manway
Heated Salt Water

Scrubbing Relief
Section Connection
16" Firetube

Treated Crude Gas Outlet


Oil Out

16"
Water Out
Manway Spreader
And Drain
Plate
Untreated
Water
Precast Crude oil Inlet
Leg
Concrete
Ladder
SECTION THRU FIREBOX SECTION THRU WATER SIPHON FRONT ELEVATION PLAN

Vertical Heater Treater


Specifications and Details
Diameter x Height (ft)

4’ x 20’ 6’ x 20’ 8’ x 20’

Working Pressure (PSI) 75 or 125 75 or 125 75 or 125


Oil treating capacity (bbl/day) 100 - 500 200 - 1000 500 - 1600
Gas capacity (MMCFD) 1-2 2-4 3-6
Fire box capacity (BTU/HR) 360,000 500,000 1,000,000
Fire box area (sq ft) 36 52 100
Fire tube size (in) 16” 16” 24”
Stack size (in) 8” 8” 16”
Settling section volume (bbl) 19 43 72
Total oil & water volume (bbl) 34.2 80.3 143
Inlet size (in) 3” 3” 4”
Oil outlet size (in) 3” 3” 4”
Water outlet size (in) 3” 3” 4”
Gas outlet size (in) 3” 3” 4”
Drain size (Siphon Type) (in) 3” 3” 3”
Water leg weir (in) 3” 3” 3”
Relief valve size (in) 2” 2” 2”
No. of 16” manways 2 2 2
Shipping weight (lbs) 6,000 8,500 11,500

productiontechnologies@nov.com nov.com/productiontechnologies
©National Oilwell Varco - All rights reserved - DPF1000042-MKT-001 Rev 01