RAMBOLL IN BRIEF
2
STUDY OF SOLAR SITES IN BIHAR
3
GREEN POWER TOWER FOR TELECOM SITES
4
GREEN POWER NEXT STEPS
Site conditions
*Cloudy Climate
GREEN POWER TOWER SOLUTIONS BY RAMBOLL
01-07-2016
STUDY OF SOLAR SITES (BIHAR)
RECOMMENDED SOLAR & WIND (HYBRID) SOLUTION
• It is seen that the load itself is not being fulfilled by the Solar panels and there is no
additional energy to charge the batteries during daytime.
• To overcome this short fall either to increase the panel size, install micro wind turbine
depending on wind condition.
• For average 1600W load ideal solar panel size is 6kWP (60 sqm area of solar panels).
• Suggested solution would be
• 3kWP from solar (30m^2)
• 3~4.5kWP from wind turbine
• Battery bank to be sized properly based on the panel size, load and Depth of discharge
required. Remote monitoring of BB health to be done.
• Automation of cell site to improve uptime and proper monitoring.
2. The global natural frequency of tower and local rotational frequency of 5 4LA_Model 1 2.38 1.77 1.42 1.2
top tube used to install the turbine in the top of tower should not 6 4LA_Model 2 3.04 2.23 1.82 1.56
coincidence.
3. For utility scale turbines, operating intervals typically range from 10 to Specifications to consider for design
50 rpm correspond to operating frequencies between 0.16 and 0.83 • Weight of rotor and total assembly
Hz for smaller turbines. • Rotational speed at cut-in wind speed.
4. The natural frequency of the wind turbine support structure must • Distance between rotor CoG and first shaft
remain above the largest operating frequency of a particular turbine bearing
by an appropriate factor, typically between 1.1 and 2, in order to • How is the turbine regulated? Free to yaw?
avoid resonance at any point throughout the turbine’s operational Can the blades pitch or does it apply
interval. centrifugal breaks when above cut-out wind
5. Major business for Opco/IP’s are active sharing and hence installing speed.
solar/turbine may reduce tower capacity if it installed on existing • Service life?
tower. • Maximum breaking moment for stopping the
6. Tower design stability shall be dependent on solar/turbine & antenna wind turbine
loading specification and need to be validated on case to case basis. • Wind turbine thrust coefficient (CT)
7. For optimum solution cost of tower structure, preferred to include • Dimensions & Drag coefficient for blades
loads of solar/turbine in the initial design to avoid additional during parked condition
retrofitting costs. • Vibration controllers