Documente Academic
Documente Profesional
Documente Cultură
Ordering Instructions--Specify
2. Electrical Classification
5. Tag
The 760 and 761 Series SINGLE STATION MICRO Controllers are a
family of self-contained, multipurpose, microprocessor based
controllers. The basic 760 Series is ideal for simple to moderately
For shelf mounted versions, refer to 2E-2A1, Pages 7 and 8 to complex applications. The 761 Series has all the capability of the
specify and price 202S Series Shelves and Cord Sets. basic 760 Series plus all the flexibility and functional capacity
required for even the most advanced control schemes, including
single station cascade.
Standard Specifications
Configurable Control Functions: Proportional Input Signals: Any combination of the following
Modes P, Pl, PD, PID, nonlinear Pl, nonlinear PID, and PID proportional inputs with total of all types not to exceed 4 for
with EXACT tuning. 760 Series, 6 for 761 Series.
External Integral (Reset) 4 Current Inputs: 4 to 20 mA dc into 250 ohm input resistors. Will
accept 1 to 5 V dc directly by removing input resistors or 10 to 50
Internally or Remotely Adjustable High and Low Output Limits mA dc directly by substituting 100 ohm input resistors on terminal
board. Includes 24 V dc source for powering up to two 4 to 20
Output Tracking mA field transmitters. Refer to Optional Features on Page 3 for
10 to 50 mA transmitters.
Output Summing
2 Frequency Inputs: Input pulse rates, voltage levels, and field power
Ratio Control are compatible with Foxboro vortex meters and turbine meters
with preamplifiers. Input impedance 500 ohms
Remote Set Point
Discrete Input Signals: 2 contact or transistor switch inputs, 5 V dc
Set Point Tracking nominal open circuit voltage, 1 mA maximum current. For remote
status changes, such as Auto/Manual, Remote/Local, etc.
Input and Output Signal Conditioning: Square, square root,
adjustable 0 to 10 minutes filter (input signal only), Analog Output Signals: 2 analog output signals. Output No. 1 is
adjustable 20 segment characterizer, adjustable ±0 to 100% a 4 to 20 mA dc control output. Output No. 2 is a 1 to 5 V dc
bias, and adjustable 0 to 10 gain. auxiliary output for retransmitting the measurement, set point,
or conditioned inputs. Refer to Optional Features on Page 3
Calculations: Multiply, divide, and sum, with appropriate scaling. for 10 to 50 mA output.
Gate Functions for Contact Inputs: AND, OR, NOR, XOR, NOT, Discrete Output Signals: 2 open collector, transistor switch outputs,
NAND, NXOR. 50 V dc maximum at 250 mA dc maximum. For status indication
of Auto/Manual, Remote/Local, Workstation/Panel, and Alarms.
FOR 761 SERIES ONLY:
Output Multiplying
Dynamic Compensation
Signal Selection
Standard Specifications
(Continued)
Electrical Classification: Display Presentation:
For all Models without Optional Feature code -3: FM (Factory 2 lines of 9 alphanumeric characters. The first line provides
Mutual) and CSA (Canadian Standards Association) certified for loop tag and prompts for configuration. The second line
use in ordinary locations. For optional Division 2 classification, provides high resolution display of inputs, set point,
specify CS-E code from table below. measurement, and outputs and prompts for configuration.
For all Models with Optional Feature code -3: Foxboro self-certified 3 bright, 50 segment bar arrays for set point, measurement,
for ordinary locations only. and output. Single bar illuminated for cursor-like display of
set point.
Alarms:
760 Series: 3 absolute alarms and 1 deviation alarm. 2 absolute Individual alpha characters for Auto/Manual, Remote/Local,
alarms assignable to measurement, 1 to output. Deviation alarm and Workstation/Panel status.
between set point and measurement. Each alarm has 2 points,
high and low. Measurement alarm status indication assignable Pictorial status indicator for alarm annunciator.
to display measurement and output bars. Alarm dead band is
adjustable to 10% of span.
761 Series: 4 dual level alarms, each with a dead band and Mounting:
1 Boolean output, are available. Each alarm is configurable Housing Mounted: Individual, single unit enclosure included
for Absolute, Deviation, Rate of Change, High/Low, with controller. Nominal panel face dimensions 72 x 144 mm
High/High, Low/Low, Latching, Nonlatching, or Permissive. (2.8 x 5.7 in) in accordance with DIN standards. Overall length
Each alarm can be configured to act on any of the from front of panel for ordinary locations approximately
internal or external signals. 480 mm (19 in). Choice of 32 point terminal board or
30 pin receptacle for Foxboro 2AK Series Cable located on
Computer Communications: RS-485 Serial Communications Port. rear of housing.
Nominal Supply Voltage and Frequency: 24, 100, 120, 220, or Shelf Mounted: For mounting in 202S Series Universal Shelves
240 V ac, 50/60 Hz or 24 V dc, as specified. with 30 conductor shelf cable and terminal board in new
installations. For mounting in EH, 101, 102, and 202 Series
Shelves with appropriate hardware, in retrofit installations only.
Optional Electrical Classification: Not available for Models with Optional Feature code -3. Select ordering code, quotation description, and price
addition from the following table.
EXACT and SINGLE STATION MICRO are trademarks of The Foxboro Company
OPTIONAL FEATURES
AS
US Dollars
Reference
Circuit Board Coating: A conformal sealant applied to the circuit board and a special oil
CBC 509.00-
added to connectors to improve corrosion resistance.
10 to 50 mA Input Signals: Consists of input resistor substitution on all 4 analog inputs to
accept 10 to 50 mA signals from self-powered sources only. Output signal remains 4 to 20 mA. SIG Net
Available for housing mounted controllers with "Housing and Signal Connections" code T only.
Surge Suppressor: For use with serial communication input when external wiring is located
near transient producing sources such as motors, solenoids, high voltages, SURSUP 184.00-
etc.
ACCESSORIES
Part No. US Dollars
Conversion Kit: To convert a 760 Series Controller to a 761 Series Controller. Firmware kit
consists of 4 plug-in modules (chips) including the nonvolatile, random access memory
710.00-
(NOVRAM) module and instruction sheets.
Specify KIT-C-760*A-761*AB
Copy Accessory: All of the operating configuration is stored in a nonvolatile, random access
memory (NOVRAM) module. The copy accessory permits the entire contents of the memory
module to be quickly copied into another memory module, either a spare or one from another
controller. Refer to instruction sheet MI 018-837
Copy Accessory K0143DV 262.00-
Spare Memory Module
for 760 Series K0143SA 223.00-
for 761 Series K0141LA 223.00-
Replacement Shelf Signal Connector Assembly: For installing Shelf Mounted Controllers,
Indicators and Manual Stations with 30-pin receptacles in existing 102, 202, and EH Series
Shelves. Connector set assembly includes plug, cable, and terminal block. Part Number
N0139CA (Type HVP), N0139CB (Type HVL), or N0139TZ (Type HVS). Power Cord also required
For 4 to 20 mA inputs and output K0143CG 481.00-
For 10 to 50 mA self-powered inputs and 4 to 20 mA output and for use with
Optional Feature code -3 K0143EF 764.00-
Guide for EH Series Shelves: A snap-in, plastic instrument guide must be added to EH Series
Shelves between instruments when installlng 760 or 761 Series Controllers and Recorders. K0143CF 14.00-
Refer to instruction sheet MI 018-842
Panel Cutout Adapter Bezels: For replacing E Series Housing Mounted Electronic CONSOTROL Control Stations/Recorders and 54 Series
Pneumatic CONSOTROL Control Stations/Recorders with 760 or 761 Series Control Stations and Recorders. Two bezels are required for each
panel cutout. Refer to instruction sheet MI 018-842 for installation details.
STANDARD SPECIFICATIONS
Control Functions: Alarms:
Dual, Independent Controllers, Single Station Cascade, Four, dual level alarms, each with a dead band and 1 Boolean
Two variable auto selector, two 7-digit totalizers, split output. Each alarm is configurable for Absolute, Deviation,
range outputs, 3-variable indicators, auto/manual transfer Rate-of-Change, High/Low, High/High, Low/Low, Latching,
stations, External Integral (Reset), Output Limits, Output Nonlatching, or Permissive. Each alarm can be configured to act
Tracking, Output Summing, Output Multiplying, Ratio on any of the internal or external signals. Alarm dead band is
Control, Remote Set Point, Set Point Tracking, adjustable to 10% of span. Measurement alarm status indication
Modes: P, PI, PD, PID, PID with EXACT tuning, and Nonlinear. assignable to display measurement and output bars.
Input and Output Signal Conditioning: Square, square root, adjustable Computer Communications: RS-485 Serial Communications Port.
0 to 10 minute input filter, two, 8-segment characterizers, adjust- Nominal Supply Voltage and Frequency: 24, 100, 120, 220, or 240 V
able ±0 to 100% bias, and 0 to 10 input gain. ac, 50/60 Hz or 24 V dc, as specified.
Calculations: Multiply, divide, and sum, with appropriate scaling Display Presentation:
Dynamic compensation, Signal selection. 2 lines of 9 alphanumeric characters. The first line provides loop
Gate Functions: AND, OR, NOR, XOR, NOT, NAND, XNOR. tag and prompts for configuration. The second line provides high
Proportional Input Signals: resolution display of inputs, set point, measurement, outputs and
Four Current Input: 4 to 20 mA dc into 250 ohm input resistors. totals.
Will accept 1 to 5 V dc directly by removing input resistors.
Includes 28 V dc source for powering up to two 4 to 20 mA field 3 bright, 50 segment bar arrays for set point, measurement, and
transmitters. output. Single bar illuminated for cursor-like display of set point.
Two Frequency Inputs: Input pulse rates, voltage levels, and field Individual alpha characters for Auto/Manual, Remote/Local, and
power are compatible with Foxboro vortex meters and turbine Workstation/Panel status.
meters with preamplifiers. Input impedance 500 ohms.
Discrete Input Signals: Two contact or transistor switch inputs, 5 V dc nominal open Pictorial status indicator for alarm annunciator.
circuit voltage, 1 mA maximum current. Mounting:
Analog Output Signals: Two, 4 to 20 mA analog output signals. Housing Mounted: Individual, single unit enclosure included
Ambient Temperature Limits: 14°F and 140°F (-10 and 60°C) with controller. Nominal panel face dimensions 72 x 144 mm
Discrete Output Signals: Two, open collector, transistor switch (2.8 x 5.7 in) in accordance with DIN standards. Overall
outputs, 50 V dc maximum at 250 mA dc maximum. length from front of panel for ordinary locations approximately
Electrical Classification: 330 mm (13 in).
FM (Factory Mutual) and CSA (Canadian Standards Association) Shelf Mounted: For mounting in 202S Series Universal Shelves
certified for use in ordinary locations. For optional Division 2 with 30 conductor shelf cable and terminal board in new
classification, specify CS-E code from Optional Features. installations. For mounting in EH, 101, 102, and 202 Series
Shelves with appropriate hardware, in retrofit installations
Conforms to the European Union Directives only.
(Symbolized by the "CE" Marking)
OPTIONAL FEATURES
AS
US Dollars
Reference
Circuit Board Coating: A conformal sealant applied to the circuit board and a special oil added
CBC 509.00-
to connectors to improve corrosion resistance
Surge Suppressor: For use with serial communication input when external wiring is located near
SURSUP 184.00-
transient producing sources such as motors, solenoids, high voltages, etc.
ACCESSORIES
Part No. US Dollars
Copy Accessory: All of the operating configuration is stored in a nonvolatile, random access
memory (NOVRAM) module. The copy accessory permits the entire contents of the memory
module to be quickly copied into another memory module, either a spare or one from another
controller. Refer to instruction book.
Copy Accessory L0122TU 261.00-
Spare Memory Module K0141LN 223.00-
Instruction Book: A very comprehensive, wire-bound instruction book, which includes
configuration worksheets, structure diagrams, parts list and dimensional prints, is included
with each controller.
To order separate copies, specify Instruction Book Number 3472 for housing mounted
37.00-
and 3476 for shelf mounted controllers.
Replacement Shelf Signal Connector Assembly: For installing Shelf Mounted Controllers,
Indicators and Manual Stations with 30-pin receptacles in existing 102, 202, and EH Series
Shelves. Connector set assembly includes plug, cable, and terminal block. Part Number
N0139CA (Type HVP), N0139CB (Type HVL), or N0139TZ (Type HVS), power cord is also
required.
For 4 to 20 mA inputs and output K0143CG See 2C-1A1,Pg 4
For 10 to 50 mA self-powered inputs and 4 to 20 mA output K0143EF 764.00-
Guide for EH Series Shelves: A snap-in, plastic instrument guide must be added to EH Series
Shelves between instruments when installing 762CSA Series Controllers and Recorders. Refer
to instruction sheet MI 018-842 K0143CF 14.00-
Description AS Reference
Single Loop Controller SINGL C
with Hi/Lo Measurement Alarm SINGL C1
with One Totalizer SINGL C2
with Hi/Lo Alarm and Totalizer SINGL C3
with split range outputs SINGL C4
with 3-variable indicator station SINGL C5
with Auto manual Transfer station SINGL C6
Dual Loop Controller DUAL C
with Hi/Low measurement alarms DUAL C1
with Two totalizers DUAL C2
with alarms and totalizers DUAL C3
3-Variable Indicator Station IND S
with three Hi/Lo alarms IND S1
with two totalizers IND S2
with alarms and totalizers IND S3
with second 3-variable indicator station IND S4
with second 3-variable indicator station, Hi/Low alarms and totalizers IND S5
with auto manual Transfer station IND S6
Auto manual Transfer station A/M S
with Hi/Low alarm A/M S1
with totalizer A/M S2
with alarm and totalizer A/M S3
with second auto manual Transfer station A/M S4
with second auto manual Transfer station, Hi/Low alarms and totalizers A/M S5
with split range outputs A/M S6
Single Loop Flow Ratio Controller, 0 to 2 Ratio Range, square root inputs RATIO C
with Hi/Low alarm RATIO C1
with one totalizer RATIO C2
with Hi/Low alarm and totalizer RATIO C3
with split range outputs RATIO C4
with 3-variable indicator station RATIO C5
with auto manual Transfer station RATIO C6
Cascade Controller CASCDE C
with Hi/Low primary alarm CASCDE C1
with one totalizer CASCDE C2
with Hi/Low alarm and totalizer CASCDE C3
Auto selector controller, low select A SEL C
with Hi/Low alarms A SEL C1
with totalizer A SEL C2
with alarms and totalizer A SEL C3
with high select A SEL C4
Single Loop Controller with Pulse or contact driven set point PULSE SP
Single Loop Controller with output freeze from external contact input 1 FREEZE
Single Loop Controller with output switching to a preset value from external contact input 1. PRESET