Sunteți pe pagina 1din 3

Classification: Internal Use

Classification: Internal Use


Rev. No.: 08
Dated: Aug/2017 EQUIPMENT / PIPING THICKNESS MEASUREMENT SHEET
SMP / WI No.: SMP-INSP-051
INSPECTION DEPARTMENT
Page: 1 of 1
Drowing/Sketch Thickness Thickness Reading
Orig. Remark(s)
Measurement (mm)
Thk.
Location *

50-KC/CL-8232125-
(mm) 0 90 180 270 N E S W
(TMLs)
1–4 "Ø 2.9 5.8 5.9 5.9 6.0
2–4 "Ø 2.9 5.8 6.0 5.9 6.0
3–4 "Ø 2.9 5.4 6.2 6.2 ELBOW
N
BB31A
4–4 "Ø 2.9 6.3 5.9 5.6 6.0

6 4 5–4 "Ø 2.9 6.0 5.6 5.9 5.9


3 6–4 "Ø 2.9 4.9 5.8 5.9 ELBOW
7 7–4 "Ø 2.9 6.1 6.0 5.9 6.0

5 8–4 "Ø 2.9 6.0 6.1 6.1 6.0


9–4 "Ø 2.9 6.4 6.1 6.0
10–4 "Ø 2.9 6.1 5.9 6.1 5.8
11–4 "Ø 2.9 6.2 6.0 5.8 5.8
2 12–4 "Ø 2.9 5.8 5.6 5.8
TV-8205 13–4 "Ø 2.9 6.0 6.1 6.0 6.1
14–4 "Ø 2.9 6.1 5.9 5.7 6.1
15–4 "Ø 2.9 6.0 6.1 5.8 5.9
8 1 16–4 "Ø 2.9 4.9 5.1 4.7 4.8
1 17–4 "Ø 2.9 2.2 2.3 2.5
3 1 9
1 Thickness Gauge S.R. No. : GE DM5E (S/N: 1309726)
1 Calibration date : 23-DEC-2018
1
2 Probe # and Frequency : DK-537 - 5 MHz (S/N: 1835/58)
0
Applicable Procedure : PK SHEM 7.05 & SMP-INSP-051
Criteria for passing Inspection : API 570
1
TP-8202 : A-106 GRB
4 Eqpt. / Piping Material
1 Corrosion Allowance (mm) : 0 mm
5 Corrosion Rate (mm / Year)
1 : -
1 6 Remaining Life (Year) : -
7 Surface Temperature (ºC) : AMBIENT
Condition of Piping : Satisfactory X Unsatisfactory
:
Recommendation (if any)

Plant : VCM – UNIT 82 Description : NEAR TP-8202 Inspector(s) : JOHNSON Date : 04/06/2019
Classification: Internal Use
Eqpt / Line No. : 100-KC/CL-8232126-PQ31A Service : CAUSTIC KARTIK