Sunteți pe pagina 1din 1

LIMITES DE ATTERBERG

ASTM D-4318 - MTC - E - 111


PROYECTO : CREACION DE UN MINI COMPLEJO DEPORTIVO EN LA LOCALIDAD DE JUAN DIAZ, DISTRITO
COLOSAY, PROVINCIA DE JAEN, DEPARTAMENTO DE CAJAMARCA
UBICACIÓN : DISTRITO COLASAY, PROVINCVIA JAEN, REGION CAJAMARCA
CALICATA : C - 01 - GRADERIAS
FECHA : ABRIL - 2019
LIMITE LIQUIDO
CALICATA Nº - MUESTRA Nº M-1 ---
PROFUNDIDAD (m) 0.25 - 2.00 ---
Número de golpes 20 28 37 --- --- ---
1. Recipiente Nº 2 3 4 --- --- ---
2. Peso suelo húmedo + Tara (gr) 48.32 52.35 55.48 --- --- ---
3. Peso suelo seco + Tara (gr) 37.91 41.39 43.91 --- --- ---
4. Peso de la Tara (gr) 14.28 15.48 15.64 --- --- ---
5. Peso del agua (gr) 10.41 10.96 11.57 --- --- ---
6. Peso del suelo seco (gr) 23.63 25.91 28.27 --- --- ---
7. Humedad (%) 44.05 42.30 40.93 --- --- ---

LIMITE PLASTICO
CALICATA Nº - MUESTRA Nº M-1 ---
PROFUNDIDAD (m) 0.25 - 2.00 ---
1. Recipiente Nº 6 --- --- --- --- ---
2. Peso suelo húmedo + Tara (gr) 20.16 --- --- --- --- ---
3. Peso suelo seco + Tara (gr) 18.61 --- --- --- --- ---
4. Peso de la Tara (gr) 12.10 --- --- --- --- ---
5. Peso del agua (gr) 1.55 --- --- --- --- ---
6. Peso del suelo seco (gr) 6.51 --- --- --- --- ---
7. Humedad (%) 23.81 --- --- --- --- ---

GRAFICO DEL LIMITE LIQUIDO


MUESTRA
M-1 ---
46.00
L.L. 43.04 ---
CONTENIDO DE HUMEDAD (%)

45.00
L.P. 23.81 ---
44.00
I.P. 19.23 ---
43.00

42.00
CLASIFICACION
41.00
25 MUESTRA SUCS AASHTO
40.00
M-1 CL A - 7 - 6 (0 )
39.00
--- --- --- (--- )
38.00
10 100
20 30 40 50
NUMERO DE GOLPES

Observaciones:
Registro INDECOPI Nº 00064062

S-ar putea să vă placă și