Sunteți pe pagina 1din 1

PT.

DALUT NUSANTARA BARU


Jl. Ikan Tongkol No. 32 E mail : dalut.nusantarabaru03@gmail.com

LIQUID PENETRANT TEST EXAMINATION REPORT


NAME OF SHIP MT. PETRO OCEAN XXVII OWNER PT . BAHANA LINE ACCEPTANCE STANDARD Section 10 To 17 EN 571-1

CLIEN NAME PT . BEN SANTOSA REPORT NO 0354/ DNB / TEK / PT / V / 2019 PAGE NO 1 Of 2

TEST PROSEDURE 0001/DNB/ - Prosedur / 1.2015 LOKASI Workshop. PT. Ben Santosa, Kamal TESTING DATE Juny 10, 2019

GENERAL PARTICULAR
* Kind of Test * Type of Particle * Dwell Time ( min ) * Document for Test * Temperature
Liquid Penetrant Test Penetrant : 10 Min
Pre Cleaning : Magnaflux SKC - S a) Examination Procedur : 30 ° C
* Object of Test Developer : 10 Min
Penetrant : Magnaflux SKL - SP 1 Drying Time : 5 Min 0001 / DNB / - Prosedur / 1.2015 * Personal Qualification
Propeller Blade
Developer : Magnaflux SKD - S2 Interpretation : 1 Hours Rev. 0 - 23 Januari a) Operator / Examiner :
* Kind of Material
Type of Penetrant : Visible * Penetrant Process b) Acceptance Code : Ahmad Wajih
Steel
Type of Develover : Non Aqueous Dev. Solvent Removable BKI Rules for Materials - 2014 b) Certificate No :
* Surface Condition
Apply of Penetrant : Spraying * Examination Medium Section 4 To 17 EN 571 - 1
Smooth 11510521
See Sketch Above

DRAWING LIQUID PENETRANT TEST


Sketched :
Propeller Blade
720

II

240
840

365
III

520

Examination area :

Result Remarks
Acc -

Indication Code LI : Linear Indication RI : Rounded Indication C : Crack

Tested by : PT. DALUT NUSANTARA BARU Reviewed by : PT. BEN SANTOSA Surveyor : BIRO KLASIFIKASI INDONESIA

SIGNATURE SIGNATURE SIGNATURE

NAME Ahmad Wajih NAME NAME M. Baqi, S.T.

LEVEL Inspector. MT/ PT Level II LEVEL QA / QC LEVEL Surveyor

DATE Juny 12, 2019 DATE DATE Juny 18, 2019