Shandong Vicot Air Conditioning Co.,Ltd.

Air Handler
Shandong Vicot Air Conditioning Co.,Ltd.

Introduction

The VICOT CTF series air handler offer state-of-the-art heat transfer technology, which are designed to fit almost anywhere
and are ideal for supermarkets, hospitals, villas, residences, hotels and office buildings.

Performance
— Efficiency range from 10SEER &13SEER
— Nominal capacity from 1.5 to 5 Tons

Features

— High quality galvanized panels ensure high corrosion resistance


— High static pressure design makes unit independent of duct system
— The evaporator uses high efficient inner screwed copper tubes and
ripple style fins, which ensures state-of-the-art heat transfer technology
— Special insulation design allows for quiet operation
— Three speed motor offers selectable airflow volume
— Advanced design allows different unique installations
— Rigorous electrical protection designed for more safety protection
— Patented diffusing equipment offers high energy efficiency.

Nomenclature

Technical Data
Shandong Vicot Air Conditioning Co.,Ltd.

Technical Data
Indoor Unit Model CTF018CN2 CTF024CN2 CTF030CN2 CTF036CN2 CTF048CN2 CTF060CN2
Outdoor Unit Model CTF018NW2 CTF024NW2 CTF030NW2 CTF036NW2 CTF048NW2 CTF060NW2
Performance Data
Nominal Cooling Capacity BTU/H 17600 22600 28600 34500 47000 55500
SEER BTU/H-W 10 10 10 10 10 10
Power / 208-230/60/1
Voltage Range / 197-253
Electric Data
Min. Operating Current A 1.9 1.9 3.4 3.4 3.9 5.9
Max. Safety Current A 10 15
Fan Motor Data
Operating Current A 2.1 2.1 3.6 3.6 4.2 6.2
Power HP 1/4 1/4 1/3 1/3 1/3 3/4
Speed High, Medium, Low
Air Outlet Dimension
Length INCH 16-5/8 16-5/8 16-5/8 16-5/8 16-5/8 19-3/4
Width INCH 11 11 11 11 11 11
Refrigerant
Type R22
Connecting Pipe Size
Liquid Pipe INCH 3/8
Gas Pipe INCH 5/8 5/8 5/8 5/8 3/4 7/8
Drain Pan Dimension INCH 3/4 3/4 3/4 3/4 3/4 3/4
Unit Size
Length INCH 23-5/8 23-5/8 23-5/8 23-5/8 23-5/8 23-5/8
Width INCH 19-1/4 19-1/4 19-1/4 19-1/4 19-1/4 22-1/2
Height INCH 37-1/2 37-1/2 37-1/2 37-1/2 41-1/4 47-1/8
Ship Weight LB 108 108 115 115 142 174
FOOTNOTES:

1. Indoor working conditioning: in cooling, temperature DB:27℃ (80 ℉), WB:19℃(67 ℉)


2. Fan Power is measured under high velocity running at the standard conditions.
3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5 meters.

As part of our continuous product improvement, Vicot reserves the right to change specifications and design without notice.
Shandong Vicot Air Conditioning Co.,Ltd.

Technical Data

Indoor Unit Model CTF018CN4 CTF024CN4 CTF030CN4 CTF036CN4 CTF048CN4 CTF060CN4


Outdoor Unit Model CTF018NW4 CTF024NW4 CTF030NW4 CTF036NW4 CTF048NW5 CTF060NW5
Performance Data
Nominal Cooling Capacity BTU/H 17600 22600 28600 34500 47000 55500
SEER BTU/H-W 10 10 10 10 10 10
Power / 220-240/50/1
Voltage Range / 198-264
Electric Data
Min. Operating Current A 1.9 1.9 3.4 3.4 3.9 5.9
Max. Safety Current A 10 15
Fan Motor Data
Operating Current A 2.1 2.1 3.6 3.6 4.2 6.2
Power HP 1/4 1/4 1/3 1/3 1/3 3/4
Speed High, Medium, Low
Air Outlet Dimension
Length INCH 16-5/8 16-5/8 16-5/8 16-5/8 16-5/8 19-3/4
Width INCH 11 11 11 11 11 11
Refrigerant
Type R22
Connecting Pipe Size
Liquid Pipe INCH 3/8
Gas Pipe INCH 5/8 5/8 5/8 5/8 3/4 7/8
Drain Pan Dimension INCH 3/4 3/4 3/4 3/4 3/4 3/4
Unit Size
Length INCH 23-5/8 23-5/8 23-5/8 23-5/8 23-5/8 23-5/8
Width INCH 19-1/4 19-1/4 19-1/4 19-1/4 19-1/4 22-1/2
Height INCH 37-1/2 37-1/2 37-1/2 37-1/2 41-1/4 47-1/8
Ship Weight LB 108 108 115 115 142 174

FOOTNOTES:

1. Indoor working conditioning: in cooling, temperature DB:27℃ (80 ℉), WB:19℃(67 ℉)


2. Fan Power is measured under high velocity running at the standard conditions.
3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5 meters.

As part of our continuous product improvement, Vicot reserves the right to change specifications and design without notice.
Shandong Vicot Air Conditioning Co.,Ltd.

Technical Data
Indoor unit Model CTRF 018CN2 CTRF 024CN2 CTRF 030CN2 CTRF 036CN2 CTRF 042CN2 CTRF 048CN2 CTRF 060CN2

Outdoor unit Model CTRF018AW2 CTRF 024AW2 CTRF 030AW2 CTRF 036AW2 CTRF 042AW2 CTRF 048AW2 CTRF 060AW2

Performance Data
Nominal Cooling
BTU/H 18500 23800 29500 36000 41000 46500 56500
Capacity
SEER BTU/H-W 13 13 13 13 13 13 13
Power / 208-230/60/1
Voltage Range / 197-252
Electric Data
Min. Operating
A 2.2 2.2 3.0 3.0 3.8 3.8 3.8
Current
Max. Safety Current A 10 15
Fan Motor Data
Operating Current A 2.0 2.0 2.7 2.7 3.2 3.2 3.2
Power HP 1/2 1/2 3/4 3/4 7/8 7/8 7/8
Speed High, Medium, Low
Air Outlet Dimension
Length INCH 19-3/4 19-3/4 19-3/4 19-3/4 19-3/4 19-3/4 19-3/4
Width INCH 11 11 11 11 11 11 11
Refrigerant
Type R22
Connecting Pipe Size
Liquid Pipe INCH 3/8
Gas Pipe INCH 3/4 3/4 3/4 3/4 3/4 3/4 7/8
Drain Pan
INCH 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Dimension
Unit Size
Length INCH 26-1/2 26-1/2 26-1/2 26-1/2 26-1/2 26-1/2 26-1/2
Width INCH 18-7/8 18-7/8 18-7/8 22-1/2 22-1/2 22-1/2 22-1/2
Height INCH 46-7/8 46-7/8 46-7/8 46-7/8 46-7/8 46-7/8 46-7/8
Ship Weight LB 132 132 132 165 165 192 192

FOOTNOTES:
1. Indoor working conditioning: in cooling, temperature DB:27℃ (81 ℉), WB:19℃(67 ℉)
2. Fan Power is measured under high velocity running at the standard conditions.
3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5 meters

As part of our continuous product improvement, Vicot reserves the right to change specifications and design without notice.
Shandong Vicot Air Conditioning Co.,Ltd.