Summary of Product element Installation (Continued) LED indication
<EX260-SPN1/-SPN2/-SPN3/-SPN4> Connecting cables Select the appropriate cables to mate with the connectors mounted on the SF BF L/A1 L/A2 PWR PWR(V) Installation & Maintenance Manual 6 SI unit. LED Status Description Fieldbus device (SI unit) Fieldbus interface connector layout OFF Operating normally EX260 Series for PROFINET 1 BUS OUT: M12 4-pin socket D-coded SI unit-related diagnostic error is detected SF No. Designation Description Red ON (load power for the valve is not supplied 2 1 or outside tolerance range). Safety Instructions 4 1 TD+ Transmit Data + 2 2 RD+ Receive Data + OFF Operating normally This manual contains essential information for the protection of users 3 3 TD- Transmit Data - •SI unit cannot detect a transmission rate and others from possible injury and/or equipment damage. 4 5 4 RD- Receive Data - and the connection to the PN master has •Read this manual before using the product, to ensure correct handling, failed. and read the manuals of related apparatus before use. BF 7 Red ON •The configuration data sent from the PN •Keep this manual in a safe place for future reference. 3 BUS IN: M12 4-pin socket D-coded master to the SI unit does not agree with •These instructions indicate the level of potential hazard by label of 1 No. Designation Description the SI unit configuration. "Caution", "Warning" or "Danger", followed by important safety No. Element Description 4 1 TD+ Transmit Data + •IP address/device name duplicated 2 information which must be carefully followed. Fieldbus interface PROFINET connection PORT 2 2 RD+ Receive Data + Green ON BUS IN side: Link •To ensure safety of personnel and equipment the safety instructions in 1 3 connector (BUS OUT) (M12 4-pin socket, D-coded) 3 TD- Transmit Data - Green OFF BUS IN side: No Link this manual and the product catalogue must be observed, along with L/A1 Fieldbus interface PROFINET connection PORT 1 4 RD- Receive Data - Yellow flashing BUS IN side: Activity other relevant safety practices. 2 connector (BUS IN) (M12 4-pin socket, D-coded) Yellow OFF BUS IN side: No Activity CAUTION indicates a hazard with a low level of risk Power supply connector layout Green ON BUS OUT side: Link Power supply with load voltage for valves and which, if not avoided, could result in minor or Power supply Caution 3 operating voltage for SI unit PWR: M12 5-pin plug A-coded Green OFF BUS OUT side: No Link moderate injury. connector L/A2 (M12 5-pin plug, A-coded) Yellow flashing BUS OUT side: Activity 3 No. Designation Description WARNING indicates a hazard with a medium level 4 Ground terminal Functional earth (M3 screw) 1 SV24 V +24 V for solenoid valve Yellow OFF BUS OUT side: No Activity of risk which, if not avoided, could result in death or 5 Output connector Output signal interface for valve manifold 4 5 2 Green ON SI unit operating voltage is supplied. Warning serious injury. 2 SV0 V 0 V for solenoid valve PWR 6 LED Bus status−specific and SI unit−specific LEDs 1 3 SI24 V +24 V for SI unit operation OFF SI unit operating voltage is not supplied. DANGER indicates a hazard with a high level of risk Mounting hole for connection to the valve 4 SI0 V 0 V for SI unit operation Green ON Load voltage for the valve is supplied. which, if not avoided, will result in death or serious 7 Mounting hole Danger manifold Load voltage for the valve is not supplied injury. 5 - Unused PWR(V) OFF or is outside the tolerance range Accessories (19 V or less) This product is class A equipment that is intended for use in an industrial Ground terminal environment. Hexagon socket head cap 2 pcs. M3x30 screw for connection to the valve Connect the ground terminal to ground. There may be potential difficulties in ensuring electromagnetic screw manifold Resistance to ground should be 100 ohms or less. compatibility in other environments due to conducted as well as radiated 1 pc. seal cap for unused fieldbus interface Seal cap disturbances. connector (BUS OUT)