Sunteți pe pagina 1din 4

26-2000 Series

Regulators - Pressure Reducing D26201821X012

Specifications
For other materials or modifications, please consult TESCOM.

OPERATING PARAMETERS
Pressure rating per criteria of ANSI/ASME B31.3

Maximum Inlet Pressure


AIR
Brass: 6000 psig / 413 bar
Stainless Steel: 10,000 psig / 690 bar
Stainless Steel (Spring and Air Load only): 15,000 psig / 1034 bar
Outlet Pressure Ranges
See Part Number Selector
Design Proof Pressure DOME
150% of rated pressure
Leakage
Non-Metal Seat: Bubble-tight
Metal Seat: 2 drops/minute at 150 SUS at 2500 psig / 172 bar SPRING
Operating Temperature
-15°F to 165°F / -26°C to 73°C
Flow Capacity
Cv = 0.02, 0.06, 0.12, or 0.30
TESCOM 26-2000 Series high pressure, low flow
MEDIA CONTACT MATERIALS piston sensed regulator is available in dome, spring
Body and air load versions. This regulator comes with
316 Stainless Steel or Brass segregated captured venting standard with inlet
Seat, Vent, and Main Valve pressure ratings of 6000-15,000 psig / 413-1034 bar.
See Part Number Selector
O-Ring Applications
See Part Number Selector
• R&D labs
Back-up Ring
Teflon® • Pressure filling
Filter* • Calibration testing
26-201XX-XX: Bronze
26-202XX-XX: 300 Series Stainless Steel • Burst testers
Remaining Parts • Component testing
316 Stainless Steel and 17-4 Stainless Steel
• High pressure hydraulic or pneumatic applications
OTHER
Features and Benefits
Cleaning
CGA 4.1 and ASTM G93 • Segregated captured vent is standard
Weight (approximate) • Three standard loading methods - spring, dome,
5.5 lbs / 2.5 kg and air actuated
*no filter with metal seat
• Available with soft and metal-to-metal seating
Teflon® is a registered trademark of E.I. du Pont de Nemours and Company.
• Standard 40 micron internal filter (soft seated
models) increases service life
• High flow version is available with Cv of 0.30
• An excellent choice to be used with the TESCOM
ER3000 Electropneumatic Controller

www.tescom.com
26-2000 Series Regulator Drawings

SPRING LOADED

psi

DOME LOADED

AIR LOADED

All dimensions are reference & nominal


Metric [millimeter] equivalents are in brackets

2
26-2000 Series Regulator Flow Charts

For more information on how to read flow curves, please refer to the Flow Curves and Calculations document (debul2007x012) in the
TESCOM catalog or on www.tescom.com.

SPRING LOADED
4500
[310]

4000

OUTLET PRESSURE - psig [bar]


[276] 26-2062D24S270
3500
[241] P1 = 4500 psig
[310 bar]
3000
[207]

2500
[172]
4500 26-2064D24S270
2000
[137]

1500
[103]
1000
[69.0]

500
[34.5] 26-2067D24S270
4500
0 20 40 60 80 100 120 140 160 180 200 210
[566] [1132] [1698] [2264] [2830] [3396] [3962] [4528] [5094] [5660] [6226]

FLOW - SCFM [SLPM] Nitrogen

DOME LOADED
4500
[310]

4000
OUTLET PRESSURE - psig [bar]

[276]

3500 26-2062D24D270
[241] P1 = 4500 psig
[310 bar]
3000
[207]

2500
[172]
26-2062D24D270
2000 4500
[138]

1500
[103]

1000
[69.0]
500
[34.5]
4500 26-2067D24D270
0 20 40 60 80 100 120 140 160 180 200 210
[566] [1132] [1698] [2264] [2830] [3396] [3962] [4528] [5094] [5660] [6226]

FLOW - SCFM [SLPM] Nitrogen

AIR LOADED
4500
[310]

4000
OUTLET PRESSURE - psig [bar]

[276]

3500
26-2062D24A270
[241] P1 = 4500 psig
[310 bar]
3000
[207]

2500
[172] 26-2064D24A270
4500
2000
[137]
1500
[103]
1000
[69.0]
500
[34.5] 4500 26-2065D24A270

0 20 40 60 80 100 120 140 160 180 200 210


[566] [1132] [1698] [2264] [2830] [3396] [3962] [4528] [5094] [5660] [6226]

FLOW - SCFM [SLPM] Nitrogen

3
26-2000 Series Regulator Part Number Selector

Repair Kits, Accessories & Modifications may be available for this product. Please contact TESCOM for more information.

S – Spring load
Example for selecting a part number: D – Dome load
A – Air load

26-20 6 1 A 2 4 S 1 7 0
SOFT GOODS MATERIAL MAIN
INLET INLET GAUGE
VALVE
MAXIMUM AND AND FLOW PORT
BASIC BODY OUTLET VENT AND
INLET BACKUP OUTLET OUTLET CAPACITY OPTIONS
SERIES MATERIAL PRESSURE O-RING PORT VENT
PRESSURE RING PORT PORT (CV) 1/4"
SEAT
TYPE SIZE NPTF
MATERIAL
26-20 1 – Brass 6000 psig Spring Load B – Buna-N Teflon® 1 – SAE 1/4" SAE 4 – 1/4" 1 – .02 5 – 17-4 0 – None
413 bar 1 – 200- (90 durometer) Teflon® 2 – NPTF 1/4" NPTF 6 – 3/8" (not Stainless
10,000 psig D – Buna-N Teflon® 3 – MS33649 1/4" MS33649 8 – 1/2"2 available Steel
6 – 316 10,000 psig 14-690 bar (70 durometer) Teflon® 4 – High 1/4" NPTF for metal 7 – Vespel® 1 – One Outlet
Stainless 690 bar (Stainless steel N – Neoprene Teflon® pressure/ seated Gauge
body only) 8 – Peek
Steel T – Viton® Teflon® Aminico models) at 90°
2 – 50-
U – Urethane Teflon® 6 – Medium 1/4" NPTF 2 – 0.06
6000 psig
9 – 316 15,000 psig1 V – Kalrez® pressure/
3.4-413 bar 3 – 0.123
Stainless 1034 bar Z – E.P Slimline
3 – 25- (metal
Steel
4000 psig and/or 2 – Two Gauge
(spring and air
1.7-275 bar Vespel® Ports at 60°
load only)
4 – 15- seat only)
2500 psig
1-172 bar
5 – 10- 3 – Two Gauge
1500 psig Ports at 60°
0.7-103 bar (left hand
6 – 5-800 psig inlet)
0.35-55 bar
7 – 5-500 psig
0.35-35 bar
Dome Load
1 – 200- 4 – Two Gauge
10,000 psig Ports at 90°
14-690 bar
(Stainless Steel
body only)
2 – 50-
6000 psig
3.4-413 bar 5 – One Outlet
7 – 5-500 psig Ports at 90°
0.35-35 bar (left hand
Air Load inlet)
1 – 200-
10,000 psig
14-690 bar
(Stainless Steel
body only)
2 – 50-
6000 psig
3.4-413 bar
4 – 15-
2500 psig
1.7-172 bar
1. 15,000 psig / 1034 bar inlet requires a CTFE back-up ring on main valve, consult TESCOM.
5 – 10- 2. 1/2" not available in High (Aminco) or Medium (Slimline) pressure ports.
1500 psig 3. Not available with 15,000 psig / 1034 bar inlet.
0.7-103 bar

WARNING! Do not attempt to select, install, use or maintain this product until you have read and fully understood the TESCOM Safety,
Installation and Operation Precautions.

D26201821X012 © 2012 Emerson Process Management Regulator Technologies, Inc. All rights reserved. 05/2012.
Tescom, Emerson Process Management, and the Emerson Process Management design are marks of one of the Emerson Process
Management group of companies. All other marks are the property of their respective owners.

www.tescom.com
4

S-ar putea să vă placă și