HEAT EXCHANGER VENDOR BID EVALUATION TABLE - KEY DATA

Condensers Reboilers Sidedraw Rundown Cooler


Fusion Weld Stelform HEI Fusion Weld (1)
Stelform (1) HEI (2)
Fusion Weld Stelform HEI
Shell Information
Shells in Series 3 3 3 1 1 1 2 2 2
Shells in Parallel 1 1 1 1 1 1 1 1 1
Passes Per Shell 1 1 1 Double Split Double Split Double Split 1 1 1
Shell Type AEU AEU AEU AHU AHU AHU AEU AEU AEU
Shell ID (mm) 1050 1050 1067 787 787 610 387 387 337
Tube Information
No. of Tube Passes 2 2 2 2 2 2 4 4 4
No. of U's 555 555 - 286 286 205 54 54 50
Overall Tube Length (mm) 6100 6100 5000 4880 4880 3500 4500 4500 4500
Performance Information
Area (m2), Total Unit 1201 1201 957 165.3 165.3 91 59.2 59.2 55
Shell Pressure Drop (kPa) 50 50 53.8 3.5 3.5 4.5 10 10 15.9
Tube Pressure Drop (kPa) 65 65 57.3 15 15 11 50 50 53.9
LMTD (oC) 12.44 12.44 - 61.78 61.78 - 13.62 13.62 -
Overall HTC (W/m2.K) 409.9 409.9 - 602 602 - 325 325 -
Heat Duty (MW) 6.127 6.127 5.83 6.15 6.15 6.15 0.262 0.262 0.263
Cost ($AUS) - 363270 271470 - 73730 63200 - 76714 50980

Notes

1. Based on Film Boiling Regime


2. Based on Convective Boiling Regime