Sunteți pe pagina 1din 3

1.) All the disk in the storage are good and online.

sccli: selected device


/dev/rdsk/c3t600C0FF000000000083E37399BABE500d0s2 [SUN StorEdge 3510
SN#083E37]
Ch Id Size Speed LD Status IDs
Rev
-----------------------------------------------------------------------
-----
2(3) 16 136.73GB 200MB ld0 ONLINE M FUJITSU MAT3147F SUN146G
1203
S/N 000523C034RU
WWNN 500000E0112957B0
2(3) 17 136.73GB 200MB ld0 ONLINE M FUJITSU MAT3147F SUN146G
1203
S/N 000523C033WW
WWNN 500000E011291E60
2(3) 18 136.73GB 200MB ld0 ONLINE M FUJITSU MAT3147F SUN146G
1203
S/N 000523C034SK
WWNN 500000E011295A70
2(3) 19 136.73GB 200MB ld0 ONLINE M FUJITSU MAT3147F SUN146G
1203
S/N 000523C034RT
WWNN 500000E011295790
2(3) 20 136.73GB 200MB ld0 ONLINE M FUJITSU MAT3147F SUN146G
1203
S/N 000523C034R7
WWNN 500000E0112955B0
2(3) 21 136.73GB 200MB ld0 ONLINE M FUJITSU MAT3147F SUN146G
1203
S/N 000523C033YG
WWNN 500000E011291F80
2(3) 22 136.73GB 200MB ld0 ONLINE M FUJITSU MAP3147F SUN146G
1701
S/N 000412R010NK
WWNN 500000E0107EC610
2(3) 23 136.73GB 200MB ld0 ONLINE M FUJITSU MAP3147F SUN146G
1701
S/N 000412R010PP
WWNN 500000E0107EC860
2(3) 24 136.73GB 200MB ld0 ONLINE M FUJITSU MAP3147F SUN146G
1701
S/N 000412R01127
WWNN 500000E0107EE700
2(3) 25 136.73GB 200MB ld0 ONLINE M FUJITSU MAP3147F SUN146G
1701
S/N 000412R010LG
WWNN 500000E0107EBB80
2(3) 26 136.73GB 200MB ld0 STAND-BY M FUJITSU MAP3147F SUN146G
1701
S/N 000412R010RA
WWNN 500000E0107EC940
2(3) 27 136.73GB 200MB ld0 STAND-BY M FUJITSU MAT3147F SUN146G
1203
S/N 000523C03414
WWNN 500000E011292280

2.)The logical drive status is also good.


sccli: selected device
/dev/rdsk/c3t600C0FF000000000083E37399BABE500d0s2 [SUN StorEdge 3510
SN#083E37]
LD LD-ID Size Assigned Type Disks Spare Failed Status
-----------------------------------------------------------------------
-
ld0 399BABE5 682.39GB Primary RAID1 10 2 0 Good
Write-Policy Default StripeSize 128KB

4.)Controller redundancy status is also enabled.

sccli: selected device


/dev/rdsk/c3t600C0FF000000000083E37399BABE500d0s2 [SUN StorEdge 3510
SN#083E37]
Primary controller serial number: 8032803
Primary controller location: Upper
Redundancy mode: Active-Active
Redundancy status: Enabled
Secondary controller serial number: 8032389

5.)Batter status of the storage is also good.

sccli: selected device


/dev/rdsk/c3t600C0FF000000000083E37399BABE500d0s2 [SUN StorEdge 3510
SN#083E37]
Upper Battery Type: 1
Upper Battery Manufacturing Date: Sat Jan 6 00:00:00 2007
Upper Battery Placed In Service: Fri Jun 1 14:45:00 2007
Upper Battery Expiration Date: Sun May 31 14:45:00 2009
Upper Battery Expiration Status: OK

Lower Battery Type: 1


Lower Battery Manufacturing Date: Sat Jan 6 00:00:00 2007
Lower Battery Placed In Service: Fri Jun 1 14:38:57 2007
Lower Battery Expiration Date: Sun May 31 14:38:57 2009
Lower Battery Expiration Status: OK

---------------------------------------------------------------
Upper Battery Hardware Status: OK
Lower Battery Hardware Status: OK

6.) From the /var/adm/messages of both the servers there is no issues


related to the disk in the storage observed. But in the server Prodapp
c1t3d0 failure prediction threshold exceeded so need to replaced.

Jan 14 15:07:27 prodapp scsi: [ID 107833 kern.warning] WARNING:


/pci@1f,700000/scsi@2/sd@3,0 (sd4):
Jan 14 15:07:27 prodapp Error for Command: load/start/stop
Error Level: Informational
Jan 14 15:07:27 prodapp scsi: [ID 107833 kern.notice] Requested
Block: 0 Error Block: 0
Jan 14 15:07:27 prodapp scsi: [ID 107833 kern.notice] Vendor:
SEAGATE Serial Number: 0447B9KFXG
Jan 14 15:07:27 prodapp scsi: [ID 107833 kern.notice] Sense Key:
Soft Error
Jan 14 15:07:27 prodapp scsi: [ID 107833 kern.notice] ASC: 0x5d
(drive operation marginal, service immediately (failure prediction
threshold exceeded)), ASCQ: 0x0, FRU: 0x5

7.)From the server all the did's appearing to both the servers status
is good.
prodapp:/dev/did/rdsk/d2 Ok
prodapp:/dev/did/rdsk/d3 Ok
prodapp:/dev/did/rdsk/d4 Ok
prodapp:/dev/did/rdsk/d5 Ok
prodapp:/dev/did/rdsk/d6 Ok
prodapp:/dev/did/rdsk/d7 Ok
prodapp:/dev/did/rdsk/d13 Ok
proddb:/dev/did/rdsk/d9 Ok
proddb:/dev/did/rdsk/d10 Ok
proddb:/dev/did/rdsk/d11 Ok
proddb:/dev/did/rdsk/d12 Ok
proddb:/dev/did/rdsk/d6 Ok
proddb:/dev/did/rdsk/d7 Ok
proddb:/dev/did/rdsk/d13 Ok

8.) It is observed there are defunct process.


In prodapp

8 Z prodapps 4537 1668 0 0:00 <defunct>

In proddb

8 Z root 2691 2690 0 0:00 <defunct>

S-ar putea să vă placă și