Documente Academic
Documente Profesional
Documente Cultură
Discussion
Afton Coleman, CFSP
Functional Definition of SIS
“Safety Instrumented System”: A
system composed of sensors, logic
solvers and final element designed to:
– Automatically take the process to a safe
state when specified dangerous
conditions exist
– Permit a process to move forward in a
safe manner when specified conditions
allow (permissive functions); or
– Take action to mitigate consequences
of an industrial hazard
Sensor
50% failures
are in Final
Control
Element
SIL 3
Linkageless feedback
Revolutionized Smart
increases reliability
Instrumentation
Over 50,000 units sold
Over 1 million units sold
Usability Enhancements
– Pushbutton autocal
– Pushbutton protection
PWB
or
– Stand alone powered by
analog signal (4-20 mA
point to point)
– Type A Device
– Trigger data captures
safety events and return
stroke
– Saves I/O Card in Control
Room, reduces wiring cost
[File Name or Event]
Emerson Confidential
27-Jun-01, Slide 10
DVC6200 SIS: Application Flexibility
With Solenoid(s)
– DVC6200 SIS can be used
– in addition to a solenoid as
a redundant element
– or as a PST only unit (ETT
DVC6200 SIS, DETT SOV) 0-24VDC
DETT
– Trigger data captures safety
events and return stroke 4-20 mA DETT
SOLENOID VALVE
SEPARATE POWER
24 VDC
SOURCES FOR DIGITAL
S VALVE CONTROLLER
AND SOLENOID VALVE
4-20 MA DC
EXHAUST
27-Jun-01, Slide 13
Online Partial Valve Stroke Testing
Safety Function Priority
• Safety demand will override PST to take the valve to safe state