Documente Academic
Documente Profesional
Documente Cultură
Belden FX Systems are available in a variety of performance levels to meet the value and
price point for a wide variety of applications. Each system is uniquely color-coded for easy
identification in the field.
The following is a recap of the five Belden FX Systems that are offered today:
Belden System FX OM1 FX OM2 FX OM3 FX OM4 FX SM A1
OS2 - 9 µm
OM1 - 62.5 µm OM2 - 50 µm OM3 - 50 µm OM4 - 50 µm
Singlemode
Multimode Multimode Multimode Multimode
Bend Insensitive
Non-Bend Insensitive Bend Insensitive Bend Insensitive Bend Insensitive
Standard TIA-492CAAB
TIA-492AAAA TIA-492AAAB TIA-492AAAC TIA-492AAAD
ANSI/TIA-568-D.3
ANSI/TIA-568-D.3 ANSI/TIA-568-D.3 ANSI/TIA-568-D.3 ANSI/TIA-568-D.3
ISO/IEC 11801
ISO/IEC 11801 ISO/IEC 11801 ISO/IEC 11801 ISO/IEC 11801
ITU G.657.A1
1G up to 550 m
Ethernet Legacy Not Recommended for New 10G up to 400 m 10G up to 30/40 km
10G up to 300 m
Applications 1G up to 275 m Designs 40G/100G up to 150 m 40G/100G up to 10/40 km
40G/100G up to 100 m
4G up to 380 m
Fibre Channel Not Recommended for New
Legacy 1G up to 300 m 8G up to 300 m 16G up to 125 m 4/8/16G up to 10 km
Applications Designs
16G up to 100 m
Fiber Cable
Erika Violet
Assemblies Orange Orange Aqua Yellow
Aqua (optional)*
Jacket Color
Pre-Term
MPO-12 0.5 dB MPO-12 0.5 dB MPO-12 0.35 dB MPO-12 0.2 dB MPO-12 0.5 dB
Connector
LC/SC/ST 0.25 dB LC/SC/ST 0.25 dB LC/SC/ST 0.25 dB LC/SC/ST 0.15 dB LC/SC/ST 0.35 dB
Loss
Tight Buffer (900 µm) Tight Buffer (900 µm) Tight Buffer (900 µm) Tight Buffer (900 µm) Tight Buffer (900 µm)
3.5 dB @ 850 nm 3.5 dB @ 850 nm 3.0 dB @ 850 nm 3.0 dB @ 850 nm 0.5 dB @ 1310 nm
Fiber Cable 1.2 dB @ 1300 nm 1.2 dB @ 1300 nm 1.2 dB @ 1300 nm 1.0 dB @ 1300 nm 0.5 dB @ 1550 nm
Loss Enterprise Loose Tube (250 µm) Enterprise Loose Tube (250 µm) Enterprise Loose Tube (250 µm) Enterprise Loose Tube (250 µm) Enterprise Loose Tube (250 µm)
3.5 dB @ 850 nm 3.5 dB @ 850 nm 3.0 dB @ 850 nm 3.0 dB @ 850 nm 0.5 dB @ 1310 nm
1.2 dB @ 1300 nm 1.2 dB @ 1300 nm 1.9 dB @ 1300 nm 1.0 dB @ 1300 nm 0.5 dB @ 1550 nm
Min. OFL
200 @ 850 nm 500 @ 850 nm 1500 @ 850 nm 3500 @ 850 nm
Bandwidth N/A
500 @ 1300 nm 500 @ 1300 nm 500 @ 1300 nm 500 @ 1300 nm
(MHz∙km)
* Belden Standard OM4 products use Erika Violet cable with Erika Violet connectors. Aqua OM4 cable and connectors are available as Tailored products by selecting OM4 fiber with the Aqua color code.
Other combinations of fiber type and color will continue to use the default connector colors with the specified cable jacket color.
Belden’s FX Fusion Splice-On connectors combine the benefits of fusion splicing with the
versatility of a field-installable connector to provide superior performance and installation
reliability.
FASTER
• Faster deployment with increased first pass termination yield
EASIER
• Easier termination technique with automated splicing tools
• Easier with existing termination tools and compatible splicers
BETTER
• Better insertion and return loss performance for futureproof networks
FX Fusion Splice-On Connectors • Better versatility for both indoor and outdoor environments
Connector Performance
FX Fusion Splicer
Description Belden Part Number
FX Fusion Active Cladding Splicer Kit (includes splicer, splice holder, charger, spare electrodes, cooling tray, FXFSTOSPL
carrying case with strap, screwdriver, and fiber seath clamps)*
*Belden's FX Fusion splicer is compatible with Splice Holder Family 2, part #FXFSSHFM2 (included), when terminating FX Fusion connectors
FXFSTOSPL, FX Fusion Active Cladding Splicer Kit
FX Fusion Installation Kits
Description Belden Part Number
Standard Tool Kit (Standard Cleaver, Fiber Preparation Tools) FXFSTOSTK
Precision Tool Kit (Precision Cleaver, Fiber Preparation Tools) FXFSTOPTK
FX Fusion Accessories
Splicer Kit Accessories
Installation Kit Accessories and Spare Parts
Description Belden Part Number Description Belden Part Number
Precision Cleaver FXFSTOPCL AC Adapter/Charger FXFSTOSAC FXFSTOSCL, FX Fusion Standard Cleaver
Standard Cleaver FXFSTOSCL Shoulder Strap FXFSTOSSS
Slitter for Jacketed Fiber FXFSTOSLT Cleaning Brushes FXFSTOSCB
Splice Holder Family 1 FXFSSHFM1 Fiber Holders/Clamps FXFSTOSFC
Splice Holder Family 2 FXFSSHFM2 Spare Electrode FXFSTOSSE
Splice Holder Family 3 FXFSSHFM3 Cooling Tray FXFSTOSCT
For a complete list of FX Fusion compatible splicers and holders, Carrying Case FXFSTOSCC
please visit www.belden.com/splice-on and refer to the installation User Guide CD FXFSTOSCD
tools reference guide.
Keys for Lock FXFSTOSKY
Screwdriver FXFSTOSSD
Yellow Tackle Box FXFSTOSTB
FT 3 LC 900 F S01
Fiber Type Connector Cable Type Product Family Packaging
1 OM1 LC LC Simplex 900 Tight Buffer F Splice-On S01 Single Pack
3 OM3 LB LC/APC Simplex 2MM Jacketed
4 OM4 SC SC Simplex
S OS2 SB SC/APC Simplex
FASTER
• Faster fiber termination in as few as 5 seconds
• Faster installation proficiency through simple termination technique
• Faster 250 µm direct installation eliminating break-out kits
EASIER
• Easier with no epoxy or polishing
• Easier no-crimp design
• Easier with duplex clips to hold TX/RX pairs together
FX Brilliance Universal Connectors
BETTER
• Better termination yield with integrated VFL feedback
Three Simple Steps
• Better universal cable support for 250 µm, 900 µm, 2 mm Jacketed, 3 mm Jacketed
1 • Better universal fiber support for OM1, OM2, OM3, OM4 as well as OS2
Insert Fiber
Connector Performance Maximum Insertion Loss Typical Insertion Loss Return Loss
Multimode 0.5 dB 0.2 dB 25 dB
Singlemode UPC 0.5 dB 0.3 dB 50 dB
Singlemode APC 0.5 dB 0.3 dB 60 dB
FX Breakout Kits
Description Belden Part Number
Breakout Kit for 2.0 mm Subunits, 6-fiber, 1-Pack AX101100
Breakout Kit for 3.0 mm Subunits, 12-fiber, 1-Pack AX101101
Breakout kit for 5.2 mm Subunits (Central Tube), 6-fiber, 1-Pack AX104695
Breakout kit for 5.2 mm Subunits (Central Tube), 12-fiber, 1-Pack AX104696
When used with the VFL, a light can be seen through the clear
window on the connector body until a fiber has been properly
terminated
FASTER
• Faster connector identification with color-coded pigtail kits
• Faster delivery with standard LC, SC or ST 2 meter pigtail kits
• Faster installation with Mass-Fusion pigtail kits
EASIER
• Easier field-termination with factory pre-terminated connectors
• Easier ordering with intuitive SmartPart numbers
FT4LC250PR12, FX Mass-fusion Pigtail, OM4 Erika Violet,
LC Simplex, 2 m
BETTER
• Better quality with precision factory-polished connectors
• Better insertion loss at 0.2 dB MPO-12 and 0.15 dB Max IL OM4
Standard Performance
Description FX OM1 FX OM3 FX OM4 FX SM FX SM/APC
Cable Performance - LC/SC/ST
IL Max. 850 nm/1300 nm (dB/Km) 3.5/1.2 3.25/1.2 3.0/1.2 –
IL Max. 1310 nm/1550 nm (dB/Km) – – – 0.5/0.5
OFN (<= 3 m)
Fire Rating OFNP for Interconnect Ribbon 12-fiber (> 3 m)
OFNR for all other cables (> 3 m)
FT4LCRIBPS019ME, FX Mass-fusion Pigtail, OM4 Erika Violet, 900 µm Color-coded fiber kit (6 or 12 colors from TIA-598)
LC Simplex, 9 m 900 µm single fiber OM1-Gray, OM3/OM4-Aqua, OS2-White
Cable Style 250 µm Bare ribbon fiber
Interconnect Simplex/Duplex, 2 mm/3 mm cords
Interconnect Ribbon 12-fiber cable
Standard Length 2 meters
Connector Performance - LC/SC/ST
IL Max. (dB) 0.25 0.25 0.15 0.35 0.35
Polish - RL Typ. (dB) PC - 30 PC - 30 PC - 30 UPC - 55 APC - 65
Mass fusion splicing can fuse up to all 12 fibers in one ribbon at once. Mass fusion pigtails
come with all 12 fibers terminated and a ribbonized open end. Splicers splice entire
ribbons simultaneously.
Tailored FX Pigtails
Building a SmartPart Number
FX Feild 1. Choose 2. Choose 3. Choose 4. Choose 5. Choose 6. Choose 7. Choose
Termination Fiber Type Connectors Cable Type Product Family Packaging
Standard Mass Fusion Pigtail Kits
Length Jacket/ Buffer
Color
FT 3 LC 900 P R12 3M
Pigtail Assembly Length (≤3 m)
SC SC Simplex 3MM 3 mm
0.5 m (19.7") FanoutJacketed
Length
Connector 7
0.5 m (19.7") Fanout Length
7M A Aqua Transion
Connector 7
Ribbon Length Ribbon Length
SA SC/APC Duplex
Connector 1
Connector 8
Connector 1 8M E Ribbon
12-fiber Erika V. Connector 8
(250 µm Ribbon Fiber)
SB SC/APC Simplex 9M D Default
Connector 9 Connector 9
Connector 2 Connector 2
Connector 10 Color Connector 10
ST ST Connector 3 Connector 3
Connector 11 Connector 11
MM MPO-12 (m)
Connector 4 Connector 4
Connector 12 Connector 12
MF MPO-12 (fConnector
) 5 Connector 5 Standard Mass Fusion Pigtail Kits
900 µm Legs
Connector 6 Long Mass FusionLong
Pigtail
MassKitsFusion Pigtail Kits Connector 6
Standard Mass Fusion Pigtail
Standard MassKitsFusion Pigtail Kits Transion Transion
PULL
4
Connector 1Connector 1 Connector 1Connector 1 5
6
7
Connector 3 8
9 Connector 3
Connector 2Connector900 µm Legs 900 µm Legs
10
Connector 2Connector 2 2 Long Mass FusionLong Mass
Pigtail KitsFusion Pigtail Kits
11
12
Connector 3Connector 3
Standard
Standard Mass Fusion Mass
Pigtail KitsFusion Pigtail Kits
Mass Fusion Pigtail Kits
Connector 3Connector 3
Connector 4 12-fiber Ribbon
(250 µm Ribbon Fiber)
Connector 4
Connector 5 Connector 5
Connector 4Connector 4 Connector 4Connector 4
Connector 6 Connector 6
Connector 5Connector 5 Pigtail Assembly
Pigtail Assembly
Length (≤3Length
m) (≤3 m) Connector 5Connector 5 Pigtail Assembly Length
Long (≤3
Pigtail
Long m)
Assembly
Pigtail Assembly
Length (≥4Length
m) (≥4 m) Long Pigtail Assembly Length (≥4 m)
Transion
Connector 7 Connector 7
Connector 6Connector 6 Connector 6Connector 6
Pigtail Assembly Length (≤3 m)
0.5 m (19.7")
0.5 mFanout
(19.7")
Length
Fanout Length 0.5 m (19.7")
0.5 mFanout
(19.7")
Length
Fanout Length
Transion Transion Transion Transion Connector 8 12-fiber Ribbon Connector 8
Connector 7Connector 7 Ribbon Length
Ribbon Length Connector 7Connector 7 Ribbon Length
Ribbon Length (250 µm Ribbon Fiber) 0.5
1
Connector 9 1
Connector 9
Connector
Connector 81Connector
Connector 81 12-fiber Ribbon
12-fiber Ribbon Connector
Connector 81Connector
2
3 8
Connector 1 12-fiber Jacketed
12-fiber Ribbon
Jacketed Ribbon
2
3
PULL
PULL
4 4
5 5
Connector 10 Connector 10
(250 µm Ribbon Fiber) (250 µm Ribbon Fiber)
6 6
PULL
4
Connector 11
Connector 11 Connector 11
Connector 11
5
6
Connector 3 Connector 3 7
8
9
1
2 1
1
2 1 Connector 11 10
11 Connector 11
Connector 12
Connector 12 3 2
3
Connector 4 Connector 12
Connector 12 3 2
3
Connector 4
12
PULL
PULL
4 4
PULL
PULL
4 4
12-fiber Ribbon
5 5
6 5 6 5
7 6 7 6
7 7
Connector 12 Connector 12
900 µm Legs
900 µm Legs 900 µm Legs
900 µm Legs
8 8
8 8
(250 µm Ribbon Fiber)
9 9
9 9
10
11
12
10
11
Connector 5 10
11
12
10
11
Connector 5
12 12
12-fiber Ribbon
12-fiber Ribbon 12-fiber Jacketed
12-fiber Ribbon
Jacketed Ribbon 900 µm Legs
Connector 6 Connector 6
(250 µm Ribbon
(250 µmFiber)
Ribbon Fiber) (250 µm Ribbon
(250 µmFiber)
Ribbon Fiber) Transion
Pigtail Assembly
Pigtail Assembly
Length (≤3Length
m) (≤3 m)
Pigtail Kits
Connector 7
Long Pigtail
LongAssembly
Pigtail Assembly
Length (≥4Length
m) (≥4 m)
Connector 7
Single Pigtails
Pigtail Assembly Length (≤3 m)
Connector 8 Connector 8 12-fiber Distribuon Cable
Pigtail Assembly Length (≤3Length
Pigtail Assembly m) (≤3 m) Connector 9 Long Pigtail
LongAssembly Length (≥4Length
Pigtail Assembly m) (≥4 m) Connector 9 Pigtail Assembly(900 µm Tight Buffered Fiber)
Length 0.5 m (19
Connector 10 Connector 10
0.5 m (19.7")
0.5 mFanout Length
(19.7") Fanout Length
1 1 1 1 Connector 1 Connector 1
2
3
2
3
Connector 11
2
3
2
3
Jacketed Length
Jacketed Length Connector 11
PULL
PULL
PULL
PULL
4 4 4 4
5 5 5 5
6 6 6 6
7
8
7
8
7
8
7
8 Connector 2
Connector 1 Connector 2
Connector 1Connector 1
9
10
11
9
10
11
Connector 12 Connector 1Connector 1
9
10
11
9
10
11
Connector 12
12 12 12 12
Connector 3 Simplex Connector Connector 3
Connector 2Connector 2 12-fiber Ribbon
12-fiber Ribbon Connector 2Connector 2 900 µm Legs 12-fiber Jacketed
12-fiber Ribbon
Jacketed Ribbon Types 900 µm Legs 900 µm Tight Buffered Fiber
(250 µm Ribbon
(250 µmFiber)
Ribbon Fiber) (250 µm Ribbon
(250 µmFiber)
Ribbon Fiber) Connector 4 Connector 4
Connector 3Connector 3 Connector 3Connector 3
Connector 5 Connector 5
Connector 4Connector 4 Connector 4Connector 4 Connector 1
Connector 6 Connector 6
Connector 5Connector 5 Pigtail Assembly
Pigtail Assembly
Length (≤3Length
m) (≤3 m) Connector 5Connector 5 Long Pigtail
LongAssembly
Pigtail Assembly
Length (≥4Length
m) (≥4 m) Simplex Connector Simplex Zip Interconnect Cable 2 mm/3 mm
Pigtail Assembly Length Connector 7 Types Connector 7
(900 µm Tight Buffered Fiber)
Connector 6Connector 6 Connector 6Connector 6
0.5 m (19.7")
0.5 mFanout
(19.7")
Length
Fanout Length
Transion Transion Connector 8 Connector 8
Connector 7Connector 7 Connector 7Connector 7 Jacketed Length
Jacketed Length Connector 1
A
Connector 9 Connector 9
Connector
Connector 81Connector
Connector 81 Connector 1 Connector
Connector 81Connector
Connector 81 12-fiber Distribuon Cable
12-fiber Distribuon Cable Connector 2
B
Connector 10 Connector 10
Connector
(900 µm Tight
(900 Buffered
µm TightFiber)
Buffered Fiber)
Connector 92Connector
Connector 92 Connector
Simplex 92Connector
Connector
Connector Connector 92
Types 900 µm Tight Buffered Fiber Connector 11
Duplex Connector Duplex Zip Interconnect Cable 2 mm/3 mm Connector 11
Types
Connector
Connector10
Connector
3Connector103 Connector
Connector10
Connector
3Connector103 (900 µm Tight Buffered Fiber)
Connector 12 Connector 12
Connector
Connector11
Connector
4Connector114 Connector
Connector11
Connector
4Connector114
Connector 1 1
2
3
900 µm Legs
Connector
Connector12 Connector
Connector12
PULL
4
Connector
5Connector125 Connector
5Connector125 5
Transion Transion
MPO Connector
12-fiber uMini-Distribuon Cable
Connector 7Connector 7 Connector 7Connector 7
Types (250 µm Loose Fiber)
Connector 1
A
Connector 9Connector 9
Please
Pigtail Assembly contact
Length
Pigtail Assembly Length Belden for any help configuring/validating
Connector 9Connector 9
Duplex Connector
SmartPart Numbers or for any other custom Engineered solutions
Duplex Zip Interconnect Cable 2 mm/3 mm
Connector 10
Connector 10 Connector
Types 10
Connector 10
(900 µm Tight Buffered Fiber) Connector 1
Connector 11
Connector 11 Connector 11
Connector 11
Simplex Connector
Connector
Connector 12
1Connector
1
Types 900 µm Tight Buffered Fiber
Connector 12 Connector 12
Connector 12
2
1 3
PULL
4
5
Connector 1 6
10
7
Simplex Connector 900 µm Legs
900 µm Legs
8
900 µm Legs
900 µm Legs
1.800.BELDEN.1 (800.235.3361) www.belden.com
Simplex Connector 9
Types Types
900 µm Tight
900 Buffered
µm TightFiber
Buffered Fiber
10
11
12
MPO Connector
12-fiber uMini-Distribuon Cable Connector 1
Types (250 µm Loose Fiber) Simplex Connector Simplex Zip Interconnect Cable 2 mm/3 mm
Types
Connector 1Connector 1 (900 µm Tight Buffered Fiber)
Simplex Connector Simplex
Simplex Connector PigtailZip Interconnect
Assembly
PigtailZip
Simplex Cable
Assembly
Length 2 mm/3
Length
Interconnect Cablemm
2 mm/3 mm
Faster.
Easier.
Better.
FASTER
• Faster field-termination with high-accessibility sliding and tilting drawers
• Faster pre-term installation with simple fixed shelves and cassettes
EASIER
• Easier installation with tool-less removable drawers and lightweight housings Top: AX104681, FX Ultra HD 1U Patch Panel Housing
Bottom: AX104683, FX UHD 4U Patch Panel Housing
• Easier port identification with clear visible labeling (shown loaded)
• Easier to configure with flexible port count LC, SC, ST and MPO modules
BETTER
• Better fiber protection with covered patch cord tray
• Better high density offering with 18-port modules for up to 72 LC Duplex ports per 1U
• Better visibility with light colored Titanium finish
FX UHD Housings
Feature-rich housings are fully enclosed to provide protection for exposed 250 µm and AX104681, FX UHD Patch Panel 1U with Mounted Splice Housing
Kit (AX104684)
900 µm fibers coupled with sliding and tilting drawers to speed up and simplify installation
and maintenance.
Total LC Duplex/ Total LC Duplex/ Belden Part Number
Number of MPO Ports using MPO Ports using
Description Module Bays FX Ultra Frames FX UHD Frames
and Cassettes and Cassettes Titanium Black
1U Housing with Front and 4 48 72 AX104681 AX105563
Rear Cable Tray
2U Housing with Front and Rear Cable Tray 8 96 144 AX104682 AX105564
4U Housing with Front and Rear Cable Tray 16 192 288 AX104683 AX105565
4U 23” Housing with Front and Top: AX105164, FX UHD 1U Patch Panel Standard Shelf
20 240 360 AX105379 –
Rear Cable Tray Bottom: AX105167, FX UHD 4U Patch Panel Recessed Shelf
Optional 1U Splice Housing Kit, 144 splices N/A N/A N/A AX104684 AX105678 (shown loaded)
(add up to 4 on the 4U Housing)1
Optional Patch Cord Tray Cover, 19”2 N/A N/A N/A AX105162 AX105672
1. Up to 4 splice housing kits can be added to 4U housings. Splice housing kits are only compatible with standard 19” rack mount housings.
2. Use with 1U or 4U housings to protect the contents of the topmost patch cord tray. Patch cord tray cover is included with 23” housings.
FC 3 U 03 LD MM A A
Fiber Type Product Family Port Count (Patch Connector (Patch Side) Connector (Trunk Side) Polarity (Trunk) Adapter Color
Side)
1 OM1 H FX UHD LD LC Duplex MM MPO-12 (m) A Type-A T Beige
03
3 OM3 U FX Ultra (1” Pull) LA LC/APC Duplex MF MPO-12 (f) 1 Type-A ALT. N Black
06
4 OM4 L FX U Angled Left SD SC Duplex A Aqua
12
S OS2 R FX U Angled Right SC SC Simplex E Erika V.
18
SA SC/APC Duplex B Blue
SB SC/APC Simplex G Green
ST ST
For further options contact Belden for custom Engineered solutions.
FC 3 U 04 LD 4M 4 A
Fiber Type Product Family Port Count Connector (Patch Side) Connector (Trunk Side) Polarity (Trunk) Adapter Color
(Patch Side)
3 OM3 H FX UHD LD LC Duplex 4M MPO-12 (8f) Male 4 SR4 (Base8) A Aqua
04 4 Ports
4 OM4 U FX Ultra 4F MPO-12 (8f) Female E Erika V.
08 8 Ports
S OS2 L FX U Angled Left B Blue
12 12 Ports
R FX U Angled Right
16 16 Ports
For further options contact Belden for custom Engineered solutions.
Patch Ports OM1 Beige OM3 Aqua OM4 Erika SM Blue SM/APC Green
Family
(fibers) Adapters Adapters Violet Adapters Adapters Adapters
MPO Type-A (Key-Up/Key-Down)
18 FX UHD – FF3H18MP FF4H18MP – FFSH18MP
12 FX Ultra – FF3U12MP FF4U12MP – FFSU12MP
LC Duplex
18 (36) FX UHD – FF3H18LD FF4H18LD FFSH18LD FFSH18LA
12 (24) FX Ultra FF1U12LD FF3U12LD FF4U12LD FFSU12LD FFSU12LA
FF3H18LD, FX UHD Frame, OM3, 18 Ports, LC Duplex,
SC Duplex Aqua Adapters
6 (12) FX Ultra FF1U06SD FF3U06SD FF4U06SD FFSU06SD FFSU06SA
SC Simplex
12 (12) FX Ultra – – – FFSU12SC FFSU12SB
ST
12 (12), Metal FX Ultra FFSU12ST –
FF 3 H 18 LD A
Fiber Type Product Family Port Count Connector Adapter Color
(Patch Side) (Patch Side)
1 OM1 H FX UHD T Beige
3 OM3 U FX Ultra (1” Pull) 03 LD LC Duplex N Black
4 OM4 06 LA LC/APC Duplex A Aqua
S OS2 12 LS LC Duplex
w/Shutters E Erika V.
18 B Blue
SD SC Duplex
SC SC Simplex G Green
SA SC/APC Duplex
SB SC/APC Simplex
SS SC Duplex
w/ Shutters
SC Simplex
SR w/ Shutters
ST ST
MP MPO Up/Down
MR MPO Up/Up
Splitter Cassette
Description Splitter Belden Part Number
(Upstream/Downstream)
SC/APC to LC/APC Single 2x8 SCSU1208SLF
SC/APC to LC/APC Single 2x16 SCSU1216SLF
SC/APC to LC/APC Dual 2x8 SCSU2208SLF
MPO/APC to LC/APC Quad 2x8 SCSH4208MLF
LC/APC to LC/APC Quad 1x8 SCSH4108LLF
LC/APC to LC/APC Dual 2x16 SCSH2216LLF
AX104681, FX UHD Housing (shown loaded from left to right with,
FCSH12SBFS, FX UHD Splice Cassette, SCSH2116SLF, FX UHD SC/APC to LC/APC Dual 1x16 SCSH2116SLF
Splitter Cassette, 2 x FCSH12LAFS, FX UHD Splice Cassettes)
SC/APC to LC/APC Single 2x32 SCSH1232SLF
TAP Cassette
Belden Part Number Number TAP
of Live Live A-Port Live B-Port TAP Port
OM4 OM4 (Aqua) OM3 A-Ports Ratio
MPO Female
SCSH2116SLF, FX UHD Splitter Cassette, OS2, Dual 1x16 Splitter, TC4H06LDMFLD TC4H06LDMFLD7A TC3H06LDMFLD 6 70/30 LC Duplex LC Duplex
SC/APC Upstream Ports, LC/APC Downstream Ports (12f)
70/30 MPO(8f)
Female MPO Female MPO Male
TC4H044F4F4M TC4H044F4F4M7A TC3H044F4F4M 4 (8f) (8f)
XPE-S0003, FX UHD Basket Hanger for 1U FX UHD Patch Panel Housings and Shelves.
Clean, simple, lightweight wall mount unit that accepts all cassettes and frames from the
FX UHD ecosystem. The FX UHD wall mount is a modular platform; A vertically stacked
configuration creates an interconnect, while the patching spaces can be combined
in a horizontal configuration to make a proper cross-connect. There are two separate
compartments, one for the main service area (lockable) and one for the patching space.
Ideal for MDUs and Passive Optical LAN applications.
EASIER
• Easier configuration with FX UHD and FX Ultra modules in LC, SC and ST
• Easier security with optical door lock
• Easier expansion with stackable design
Economical yet effective. Low to medium density rack mount fiber panels with simple
adapter strips are the mainstay for fiber field termination.
FASTER
•• Faster access to rear side (trunk) connectivity without removing patch cords
EASIER
•• Easier on the budget with economical adapter strips AX100041, FX 12/24 Port (1U) Rack Mount Patch Panel
•• Easier access to the trunk side connectivity with swing out faceplate
BETTER
•• Better support for mixed field-term connectivity including splicing
•• Better use of valuable space through a compact footprint
Belden's FX Enterprise Closet X (ECX) Patch Panel system is an elegant, intuitive and
flexible solution that has been designed to maximize installer flexibility when compared
to industry-leading solutions. FX ECX has been optimized for LAN environments, and
provides an easy-to-deploy, efficient solution for installers.
FASTER
• Faster installation with fewer detachable components
• Faster field termination with removable clear top covers (all panels) and removable front
ECX-01U, FX ECX 1U Housing and rear housing (4U)
EASIER
• Easier frequent MAC work with front and rear removable cassettes (patent pending)
• Easier to configure with flexible port count LC, SC, ST and MPO couplers as well as
KeyConnect compatibility (copper and multimedia modules)
• Easier port identification with retractable label holder and compatibility with LabelFlex
labels (optional)
BETTER
ECX-02U, FX ECX 2U Housing • Better fiber routing with slack management integrated into the splice cassette lid
(eliminates pinch points)
• Better management with multiple built-in options for cable and patch cords strain relief
• Better flexibility to support all modern field-termination techniques (Splice trays, Splice
cassettes, Splice-on connectors, Mechanical splice connectors)
FX ECX Housings
Total LC Duplex using Total LC Duplex using
Description Number of Module Bays Belden Part Number
ECX Frames ECX Cassettes
1U Housing 2 Cassettes or Frames 32 24 ECX-01U
ECX-04U, FX ECX 4U Housing
2U Housing 4 Cassettes or Frames 96 72 ECX-02U
4U Housing 12 Cassettes or Frames 192 144 ECX-04U
ECX-INTERSTR ECX-4U-INTSTR
FF S F 06 SC
Fiber Type Product Family Port Count Connector
(Patch Side) (Patch Side)
1 OM1 X ECX
3 OM3 03 LD LC Duplex
4 OM4 06 LA LC/APC Duplex
S OS2 08 SD SC Duplex
12 SC SC Simplex
16 SA SC/APC Duplex
FF4X16LD, LC Duplex Frame, OM4 Ericka Violet Adapters SB SC/APC Simplex
ST ST
MP MPO Up/Down
FC S F 06 SC FS
Fiber Type Product Family Port Count Connector Connector
(Patch Side) (Patch Side) (Trunk Side) FC1X12SCFS, SC Simplex Splice Cassette, OM1 Beige Adapters
1 OM1 X ECX
3 OM3 03 LD LC Duplex FS Splice Cassette
4 OM4 06 LA LC/APC Duplex
S OS2 08 SD SC Duplex
12 SC SC Simplex
SA SC/APC Duplex
SB SC/APC Simplex
ST ST
MP MPO Up/Down
Standard FX ECX Splitter Cassettes FC4X12LDFS, LC Duplex Splice Cassette, OM4 Ericka Violet Adapters
FASTER
• Faster delivery with off-the shelf availability of standard items
• Faster identification of fiber type with Erika Violet for OM4 cable and connectors
EASIER
FX MPO-12(f) Patch Cords, Assortment • Easier installation in dense cable trays with small diameter cord options
• Easier ordering with simple intelligent SmartPart Numbers
• Easier polarity management with industry leading easy-to-use duplex clips
BETTER
• Better architectural flexibility with low-loss OM4 0.2 dB MPO and 0.15 dB LC connectors
• Better ruggedization with larger diameter cord options
• Better flexibility with multiple connector options including LC, SC, ST and MPO
• Better quality through exhaustive design validation against TIA standards
FX LC Duplex Patch Cords, Assortment
FX Patch Cords - Standard Performance
Description FX OM1 FX OM3 FX OM4 FX SM FX SM/APC
Cable Performance - LC/SC/ST
IL Max. 850 nm/1300 nm (dB/Km) 3.5/1.2 3.0/1.2 3.0/1.0 –
IL Max. 1310 nm/1550 nm (dB/Km) – – – 0.5/0.5
Fire Rating LC/SC/ST: Riser
LC: Interconnect Duplex Zip 2 mm
Cable Style LC Uniboot: Interconnect Mini-Round 2 mm
SC/ST/Hybrid: Interconnect Duplex Zip 3 mm
FX LC Duplex UHD Uniboot Patch Cords, Assortment Jacket Color Orange Aqua Erika Violet Yellow Yellow
Connector Performance - LC/SC/ST
IL Max. (dB) 0.25 0.25 0.15 0.35 0.35
Polish - RL Typ. (dB) PC - 30 PC - 30 PC - 30 UPC - 55 APC - 65
Polarity A-TO-B / B-TO-A
Connector Color Beige Aqua Erika Violet Blue Green
Cable Performance - MPO
IL Max. 850 nm/1300 nm (dB/Km) 3.5/1.2 3.0/1.2 3.0/1.0 –
IL Max. 1310 nm/1550 nm (dB/Km) – – – 0.5/0.5
Fire Rating Plenum
Cable Style MPO-12: Interconnect Mini-Round 2 mm
Jacket Color Orange Aqua Erika Violet Yellow Yellow
FX SC Duplex Patch Cords, Assortment
Connector Performance - MPO
IL Max. (dB) 0.5 0.35 0.2 – 0.5
Polish - RL Typ. (dB) PC - 30 PC - 30 PC - 30 – APC - 60
Polarity Type-B
Connector Color Beige Aqua Erika Violet Blue Green
FP 3 LD LD 003M
FP4LULU003M, LC Duplex UHD Uniboot to LC Duplex
UHD Uniboot, OM4 Erika Violet Fiber Type Connector 1 Connector 2 Length*
1 OM1 LD LC Duplex LD LC Duplex
00M3 to 015M
3 OM3 LC LC/APC Duplex LA LC/APC Duplex
*use M as decimal
4 OM4 LI LC Duplex UHD LI LC Simplex UHD
S OS2 LU LC Duplex UHD Uniboot LU LC Duplex UHD Uniboot
LF LC/APC Simplex UHD LF LC/APC Simplex UHD
SD SC Duplex SD SC Duplex
SA SC/APC Duplex SA SC/APC Duplex
ST ST ST ST
4F MPO-12 (F) Base 8 4F MPO-12 (F) Base 8
MF MPO-12 (F) MF MPO-12 (F)
NF MPO-24 (f) NF MPO-24 (f)
See FX Patch cords - Standard Performance table for standard defaults (Page 24).
FP 3 LD LD 003M R 3 X A
Fiber Type Connector 1 Connector 2 Length* Fire Rating Cable Construction Polarity Jacket Color
1 OM1 LD LC Duplex LD LC Duplex 00M3 to 100M R Riser 2 Duplex ZipCord 2.0 mm X A/B (Cross) O Orange
2 OM2 LC LC Simplex LC LC Simplex M Meters P Plenum 3 Duplex ZipCord 3.0 mm S A/A (Straight) Y Yellow
3 OM3 LM Mini-LC Duplex LM Mini-LC Duplex use M as decimal L LSZH 4 Simplex Cord 2.0 mm A Type-A A Aqua
4 OM4 LA LC/APC Duplex LA LC/APC Duplex 5 Simplex Cord 3.0 mm B Type-B E Erika V.
S OS2 LB LC/APC Simplex LB LC/APC Simplex 6 Round 2.0 mm C Type-C
LI LC Simplex UHD LI LC Simplex UHD
7 Round 3.0 mm
LU LC Duplex UHD Uniboot LU LC Duplex UHD Uniboot
LF LC/APC Simplex UHD LF LC/APC Simplex UHD
SD SC Duplex SD SC Duplex
SC SC Simplex SC SC Simplex
SA SC/APC Duplex SA SC/APC Duplex Examples:
SB SC/APC Simplex SB SC/APC Simplex FP3LULU020MR6XA - FX Patch Cord, 0M3, LC Duplex UHD Uniboot - LC Duplex UHD
ST ST ST ST Uniboot, 20 m, OFNR, Round 2.0 mm, A-to-B, Aqua Jacket
4M MPO-12 (M) Base 8 4M MPO-12 (M) Base 8 FP4LDLD030MR2XE - FX Patch Cord, 0M4, LC Duplex - LC Duplex, 30 m, OFNR,
4F MPO-12 (F) Base 8 4F MPO-12 (F) Base 8 Duplex Zip 2.0 mm, A-to-B, Erika Violet Jacket
MM MPO-12 (M) MM MPO-12 (M) FP4LDLD030MR2XE - FX Patch Cord, 0S2, SC Duplex - SC Duplex, 5 m, OFNP,
MF MPO-12 (F) MF MPO-12 (F) Duplex Zip 3.0 mm, A-to-B, Yellow Jacket
NM MPO-24 (m) NM MPO-24 (m) FP3LDLH010MR2XA - FX Patch Cord, 0M3, LC Duplex - LC Duplex UHD, 10 m,
NF MPO-24 (f) NF MPO-24 (f) OFNR, Duplex Zip 2.0 mm, A-to-B, Aqua Jacket
ZZ OPEN FP4MFMF005MP6AE - FX Patch Cord, 0M4, MPO-12 (F) - MPO-12 (F), 5 m, OFNP,
Round 2.0 mm, Type-A, Erika Violet Jacket
Tailored FX Patch Cord SPN table should ONLY be used for any product combination
that is not covered by the Standard FX Patch Cords configurator above.
Please contact Belden for any help configuring/validating SmartPart Numbers or for any other custom Engineered solutions
Uniquely suited within dense fixed environments. Compact alternative for statically
configured patch cords and pre-term cassettes eliminates connection points to improve
performance and alleviate space constraints.
FASTER
• Faster deployment at the switch with MPO to LC fanout construction
• Faster installation with lighter LPM transitions, 40% less weight
BETTER
• Better identification of fiber type with Erika Violet for OM4 cable and connectors
• Better cable stress with LPM integrated transition boot for best bend radius control
• Better airflow and cable routing with our new smaller (25%) LPM transition
FP 3 LD MF 003M
Fiber Type Connector 1 Connector 2 Length*
3 OM3 LD LC Duplex MM MPO-12 (m)
LM Mini-LC Duplex MF MPO-12 (f) 001M to 015M
4 OM4
LA LC/APC Duplex 4M MPO-12 (M) Base 8 *use M as decimal
FP3LDMF002M, FX Hydra Patch Cord, OM3, MPO-12F (F) to S OS2
6 x LC Duplex, 2 m LU LC Duplex UHD Uni 4F MPO-12 (F) Base 8
See FX Hydra Patch cords - Standard Performance table for standard defaults (Page 27)
FP 3 LD MF 003M P 7 A A
Fiber Type Connector 1 Connector 2 Length Fire Rating Cable Construction Polarity Jacket Color
1 OM1 LD LC Duplex MM MPO-12 (m) P Plenum 7 Round 3.0 mm Type-A O Orange
2 OM2 001M to 300M L LSZH A (Straight Y Yellow
LC LC Simplex
3 OM3 MF MPO-12
Female
(f) *use M as decimal Polarity)
A Aqua
LM Mini-LC Duplex Type-B
4 OS4 LA LC/APC Duplex 4M Base 8 (M)
MPO-12 B (Reversed E Erika V.
S OS2 Polarity)
LB LC/APC Simplex
4F MPO-12
Base 8
(F) 4 SR4
LI LC-Simplex UHD
LU LC-Duplex UHD Uni
LF LC/APC Simplex UHD Examples:
FP3LDMF020MP7AA - FX Patch Cord, 0M3, 6 x LC Duplex -MPO-12 (F), 20 m, OFNP, Round 3.0 mm, Type-A, Aqua Jacket
SD SC Duplex
FP4LUMM010MP7AA - FX Patch Cord, 0M4, 6 x LC Duplex UHD Uniboot - MPO-12 (M), 10 m, OFNP, Round 3.0 mm, Type-A, Aqua Jacket
SC SC Simplex FP3LDMM005MP7BA - FX Patch Cord, 0M3, 6 x LC Duplex - MPO-12 (M), 5 m, OFNP, Round 3.0 mm, Type-B, Aqua Jacket
SA SC/APC Duplex FP4LDMF025MP7AE - FX Patch Cord, 0M4, 6 x LC Duplex - MPO-12 (F), 25 m, OFNP, Round 3.0 mm, Type-A, Erika Violet Jacket
SB SC/APC Simplex
ST ST
Tailored FX Hydra Patch Cords SPN table should ONLY be used for any product combination
that is not covered by the Standard FX Hydra Patch Cords configurator above.
Please contact Belden for any help configuring/validating SmartPart Numbers or for any other custom Engineered solutions
A A
B B 1
1 2
2 3
A 3 A 4
B 4 B 5
PULL
5 6
PULL
6 7
7 8
A 8 A
B 9 9
10 B 10
11 11
A 12
A 12
B B
A
B
Industry-leading low-loss MPO trunks are the foundation of Faster, Easier and Better
pre-terminated fiber connectivity solutions revolutionizing the data center. Quality is
enhanced through exhaustive design validation against TIA standards.
FASTER
• Faster fiber-type identification with Erika Violet for OM4 Cable, Connectors
and Adapters
• Faster installation with pre-terminated solutions and 40% lighter LPM transition LPM transition on Hydra patch cord
• Faster pulling eye removal in less than 20 seconds with LPM transition and pulling tension
of up to 100 lbs
EASIER
• Easier installation with 3-flange reel and default pulling eye
• Easier ordering with simple, intelligent SmartPart Numbers
• Easier upgradeability to 40G and 100G with MPO pre-term solutions
• Easier patch panel attachment with LPM transition
BETTER
• Better architectural flexibility with high-performance 0.2 dB OM4 MPO connectors
• Better cable stress with LPM integrated transition boot for best bend radius control
FM4MMB1010M, FX MPO Trunk, OM4, MPO-12 (Male to Male),
• Better contamination control with Data Center Ready packaging Type-B, 1 x MPO-12 (12 fibers), 10 m, OFNP, Mini- Distribution
4.8 mm (Double-Jacket), Erika Violet Jacket
FM 3 M M B 3 010M
Fiber Type Connectors Connector Gender Polarity Connector Count Length
(outside)
3 OM3 M MPO-12(12F) M Male to Male 1 12 Fibers 005M to 500M
4 OM4 F Female to Female A Type-A 2 24 Fibers M Meters
S OS2 E Extension (M to F) B Type-B 3 36 Fibers *use M as decimal
P Male to Open C Type-C 4 48 fibers
FM3MMB1010M, FX MPO Trunk, OM3, MPO-12 (Male to Male), R Female to Open 6 72 Fibers
TYPE-B, 1 x MPO-12 (12 fibers), 10 m, OFNP, Mini-Distribution 8 96 Fibers
4.8 mm (Double-Jacket), Aqua Jacket See FX MPO Trunks - Standard Performance table
D 144 Fibers
for standard defaults (Page 29)
Examples:
FM3MMB1010M - FX MP0 Trunk 0M3, MP0-12 (Male to Male), Type-B, 1 MP0 (12 Fibers),
10 m, 0FNP, Mini-Distribution 4.8 mm (Double-Jacket), Aqua Jacket.
FM4MMB4030M - FX MP0 Trunk 0M4, MP0-12 (Male to Male), Type-B, 4 MP0 (48 Fibers), 30 m, 0FNP,
Mini-Distribution (2.0 mm Sub-Units) Fan-Out: 0.5 m In-Line, Erika Violet Jacket.
FMSMFAD025M - FX MP0 Trunk 0S2, MP0-12 (Female to Female), Type-A, 12 MP0 (144 Fibers), 25 m,
0FNP, Mini-Distribution (2.0 mm Sub-Units) Fan-Out: 0.5 m In-Line, Yellow Jacket.
FM 3 M M B 4 010M P M E A
Fiber Type Connectors Connector Polarity Connector Length Fire Rating Cable Construction Jacket
Fan-Out Geometry Color
Gender (outside) Count
1 OM1 MPO-12 005M to 500M P Plenum U uMini-D D None (1 Conn.) O Orange
M
2 OM2 (12F) M Male
Male
to A Type-A 1 12 Fibers
M Meters 0.5 m x In-Line N Black
B Type-B 2 24 Fibers I I/O Plenum M Mini-D D
3 OM3 (>2 Conn.) Y Yellow
F Female to
Female *use M as decimal
C Type-C 3 36 Fibers Plenum E 1.0 m x In-Line
4 OM4 A Armored A Aqua
S OS2 E Extension
(M to F)
4 48 Fibers (AIA) F 1.5 m x In-Line Erika
6 72 Fibers Plenum I/O E Violet
P Male
Open
to
8 96 Fibers B Armored G 2.0 m x In-Line
(AIA) 0.5 m x Stag
R Open to
Female D 144 Fibers 1 80 mm/1 conn.
L LSZH
2 0.5 m x Stag
80 mm/2 conn.
Tailored FX MPO Trunks SPN table should ONLY be used for any product combination that
3 0.5 m x Stag
is not covered by the Standard FX MPO Trunks configurator above. 80 mm/3 conn.
4 0.5 m x Stag
Use of Tailored part numbers: 80 mm/4 conn.
N No Pulling Eye
• Fiber Type: For any OM1 and OM2 trunk.
B Pulling Eye at
• Fire Rating: For any Plenum Armored, I/0 Plenum, I/0 Plenum Armored, LSZH trunks. both ends
• Cable Construction:
”M” Mini-Distribution cable used for indoor Plenum 12F (1 conn.), for I/0 Plenum, for Plenum Armored, for I/0 Plenum Armored and LSZH.
”U” uMini-Distribution cable used for indoor Plenum >=24F (>=2 conn.).
• Fan-Out Length & Geometry: Different fan-out lengths and stagger options, No Pulling Eye, Pulling eye at both ends.
Examples:
FM3MMB1010MPMNA - FX MP0 Trunk 0M3, MP0-12 (Male to Male), Type-B, 1 MP0 (12 Fibers),
10 m, 0FNP, Mini-Distribution 4.8 mm (Double-Jacket), No Pulling Eye, Aqua Jacket.
FM4MMB4020MAMDE - FX MP0 Trunk 0M4, MP0-12 (Male to Male), Type-B, 4 MP0 (48 Fibers), 20 m, 0FCP,
(Plenum Armored), Mini-Distribution (3.0 mm Sub-Units) Fan-Out: 0.5 m In-Line, Erika Violet Jacket.
FMSMFA2030MPM1Y - FX MP0 Trunk 0S2, MP0-12 (Female to Female), Type-A, 2 MP0 (24 Fibers), 30 m, 0FNP,
Mini-Distribution (3.0 mm Sub-Units) Fan-Out: 0.5 m Staggered 80 mm/ 1 CONN, Yellow Jacket.
Please contact Belden for any help configuring/validating SmartPart Numbers or for any other custom Engineered solutions
FM 3 4 M B 3 010M
Fiber Type Connectors Connector Gender Polarity Connector Count Length
(outside)
3 OM3 4 MPO-12 (8F) M Male to Male 1 8 Fibers 005M to 500M
4 OM4 F Female to Female A Type-A 2 16 Fibers M Meters
S OS2 E Extension (M to F) B Type-B 3 24 Fibers *use M as decimal
P Male to Open C Type-C 4 32 fibers
R Female to Open 6 48 Fibers
8 64 Fibers
See FX MPO Trunks - Standard Performance table for D 96 Fibers
standard defaults (Page 29)
Examples:
FM34MB1010M - FX MP0 Trunk 0M3, MP0-12 Base 8 (Male to Male), Type-B, 1 MP0 (8 Fibers),
10 m, 0FNP, Mini-Distribution 4.8 mm (Double-Jacket), Aqua Jacket.
FMS4FAD025M - FX MP0 Trunk 0S2, MP0-12 Base 8 (Female to Female), Type-A, 12 MP0 (96 Fibers),
25 m, 0FNP, Mini-Distribution (2.0 mm Sub-Units) Fan-Out: 0.5 m In-Line, Yellow Jacket.
FM 3 4 M B 3 010M P U E A
Fiber Type Connectors Connector Polarity Connector Length Fire Rating Cable Construction Fan-Out Geometry Jacket
Gender (outside) Count Color
3 OM3 MPO-12 005M to 500M P Plenum U uMini-D D None (1 Conn.)
4 O Orange
4 OM4 (8F) M Male
Male
to A Type-A 1 8 Fibers
M Meters I I/O Plenum 0.5 m x In-Line
B Type-B 2 16 Fibers M Mini-D D (>2 Conn.) N Black
S OS2 Plenum
F Female to *use M as decimal
Female C Type-C 3 24 Fibers A Armored Y Yellow
E 1.0 m x In-Line
Extension 4 32 Fibers (AIA) A Aqua
E (M to F) F 1.5 m x In-Line
6 48 Fibers Plenum I/O G 2.0 m x In-Line E Erika
P Male
Open
to B Armored
0.5 m x Stag
Violet
8 64 Fibers (AIA) 1 80 mm/1 conn.
R Female
Open
to D 96 Fibers
L LSZH 2 0.5 m x Stag
80 mm/2 conn.
Tailored FX MPO Trunks SPN table should ONLY be used for any product combination 3 0.5 m x Stag
80mm/3 conn.
that is not covered by the Standard FX MPO Trunks configurator above.
4 0.5 m x Stag
80 mm/4 conn.
Use of Tailored part numbers:
N No Pulling Eye
• Fiber Type: For any OM1 and OM2 trunk.
• Fire Rating: For any Plenum Armored, I/0 Plenum, I/0 Plenum Armored, LSZH trunks. B Pulling Eye at
both ends
• Cable Construction:
”M” Mini-Distribution cable used for indoor Plenum 12F (1 conn.), for I/0 Plenum, for Plenum Armored, for I/0 Plenum Armored and LSZH.
”U” uMini-Distribution cable used for indoor Plenum >=24F (>=2 conn.).
• Fan-Out Length & Geometry: Different fan-out lengths and stagger options, No Pulling Eye, Pulling eye at both ends.
Examples:
FM34MB1010MPMNA - FX MP0 Trunk 0M3, MP0-12 Base 8 (Male to Male), Type-B, 1 MP0 (8 Fibers),
10 m, 0FNP, Mini-Distribution 4.8 mm (Double-Jacket), No Pulling Eye, Aqua Jacket.
FM44MB4020MAMDE - FX MP0 Trunk 0M4, MP0-12 Base 8 (Male to Male), Type-B, 4 MP0 (32 Fibers), 20 m, 0FCP,
(Plenum Armored), Mini-Distribution (3.0 mm Sub-Units) Fan-Out: 0.5 m In-Line, Erika Violet Jacket.
Please contact Belden for any help configuring/validating SmartPart Numbers or for any other custom Engineered solutions
FASTER
FX Multi-fiber Trunk, OS2, 24F, Yellow jacket
• Faster fiber-type identification with Erika Violet for OM4 Cable, Connectors
and Adapters
• Faster installation with pre-terminated solutions and 40% lighter LPM transition
• Faster pulling eye removal in less than 20 seconds with LPM transition and pulling tension
of up to 100 lbs
EASIER
• Easier installation with 3-flange reel and default pulling eye
• Easier ordering with simple, intelligent SmartPart Numbers
• Easier upgradeability to 40G and 100G with MPO pre-term solutions
• Easier patch panel attachment with LPM transition
A 3 12 LD A LD A P 030M
Fiber Type Fiber Count Connector 1 Cable Construction Connector 2 Cable Construction Fire Rating Length
1 OM1 06 6 Fibers LD LC Duplex A 900 μm x 0.5 m x LD LC Duplex A 900 μm x 0.5 m x In-Line P Plenum
In-Line 005M to 500M
2 OM2 08 8 Fibers LC LC Simplex LC LC Simplex B 900 μm x 1.0 m x In-Line I I/O Plenum
B 900 μm x 1.0 m x M = Meters
3 OM3 12 12 Fibers LM Mini-LC Duplex In-Line LM Mini-LC Duplex C 900 μm x 1.5 m x In-Line Plenum
A Armored *use M as decimal
4 OS4 16 16 Fibers LA LC/APC Duplex C 900 μm x 1.5 m x LA LC/APC Duplex D 900 μm x 2.0 m x In-Line
In-Line (AIA)
S OS2 24 24 Fibers LB LC/APC Simplex LB LC/APC Simplex E Jacketed x 0.5 m x In-Line
D 900 μm x 2.0 m x Plenum I/O
32 32 Fibers LI LC-Simplex UHD In-Line LI LC-Simplex UHD F Jacketed x 1.0 m x In-Line B Armored
36 36 Fibers LU LC-Duplex UHD Uni Jacketed x 0.5 m x LU LC-Duplex UHD Uni G Jacketed x 1.5 m x In-Line (AIA)
E In-Line
48 48 Fibers LE LC/APC Duplex UHD LE LC/APC Duplex UHD H Jacketed x 2.0 m x In-Line L LSZH
F Jacketed x 1.0 m x
64 64 Fibers SD SC Duplex In-Line SD SC Duplex Z 250 μm x OPEN
72 72 Fibers SC SC Simplex Jacketed x 1.5 m x SC SC Simplex 1 Jacketed x 0.5 m x Stag
G In-Line 80 mm/1 con
96 96 Fibers SA SC/APC Duplex SA SC/APC Duplex Jacketed x 0.5 m x Stag
H Jacketed x 2.0 m x 2
A8 144 Fibers SB SC/APC Simplex In-Line SB SC/APC Simplex 80 mm/2 con
ST ST ST ST 3 Jacketed x 0.5 m x Stag
Examples: 80 mm/3 con
4M MPO-12 (M) SR4 Jacketed x 0.5 m x Stag
A412LDELDEP020M - FX Multi-Fiber Trunk, OM4, 12 Fibers, LC Duplex (Jacketed x 0.5m x In-Line) - LC Duplex 4F MPO-12 (F) SR4 4 80 mm/4 con
(Jacketed x 0.5m x In-Line), OFNP, 20 m, Erika Violet Jacket
MM MPO-12 (M) 6 Jacketed x 0.5 m x Stag
A324LCALCAP050M - FX Multi-Fiber Trunk, OM3, 24 Fibers, LC Simplex (900UM x 0.5m x In-Line) - LC Simplex 80 mm/6 con
(900UM x 0.5m x In-Line), OFNP, 50 m, Aqua Jacket MF MPO-12 (F) 900 μm x 0.5 m x Stag
ZZ OPEN R 80 mm/1 con
AS48LDFSCBP030M - FX Multi-Fiber Trunk, OS2, 48 Fibers, LC Duplex (Jacketed x 1.0m x In-Line) - SC Simplex
(900UM x 1.0m x In-Line), OFNP, 30 m, Yellow Jacket
S 900 μm x 0.5 m x Stag
80 mm/2 con
T 900 μm x 0.5 m x Stag
80 mm/3 con
U 900 μm x 0.5 m x Stag
80 mm/4 con
V 900 μm x 0.5 m x Stag
80 mm/6 con
Strategically placed connectivity through overt design. Compact low-port count field-term
or pre-term distributed consolidation points minimizing installation time by maximizing
trunk capacity.
FASTER
• Faster installation with a variety of surface mount options
EASIER
• Easier distribution of low port count connectivity and breakouts with self-contained designs
• Easier field-termination with easily accessible consolidation points
BETTER
FWSWBF04SB, FX W-Box, 4 x SC/APC Simplex
• Better options for pre-term and field-term including splicing
The FX Secure/Keyed LC System allows for The Secure/Keyed LC FX Ultra Frames and
physical segregation of network segments Cassettes can be used with the FX UHD
in secure fiber cabling infrastructures. All Rack and FX Ultra Wall-mount Patch Panels
Secure/Keyed LC products are available to provide an Ultra high-density patching
with 12 different keying options each system that is easy to deploy, operate and
FX Secure/Keyed LC System carrying a different color to facilitate maintain, while ensuring maximum uptime,
network administration. The keying detail uninterrupted availability and superior
inside the connector is highly tamper- performance.
resistant and cannot be reproduced
The Secure/Keyed LC Patch Cords and
inside a standard LC connector to
Pigtails are offered in Multimode 62.5 μm
violate the network security. All products
(OM1), laser-optimized 50 μm (OM3 and
comply with the FOCIS 10 standard and
OM4) and Singlemode (OS2) for the most
optical performance exceeds all industry
demanding network performance.
standards for SFF connectors.
The Secure/Keyed LC Brilliance Universal
The Secure/Keyed LC Adapter Modules,
Field Installable Connectors are available
Frames, Cassettes and Adapter Strips
in Multimode 50 μm laser-optimized (OM4,
can be used in all mounting hardware for
OM3 compatable) and Singlemode (OS2)
workstation area, Consolidation Point or
fiber versions.
Telecom Room applications. The Secure/
Keyed LC FX Manager Modules can be
used in 19- and 23-inch FX Manager
FX Brilliance Connectors Shelves to provide a high-density
management system.
FX Secure/Keyed LC System
Description Splices
LC Key1 Red
LC Key2 Green
LC Key3 Yellow
FX Secured/Keyed LC Ultra Cassette LC Key4 Black
LC Key5 Orange
LC Key6 Blue
LC Key7 Violet
LC Key8 Rose
LC Key9 Aqua
LC KeyA Brown
LC KeyB Slate
LC KeyC White
FX Secure/Keyed LC Manager Module For additional details, please refer to the Secure/Keyed LC System Product Bulletin PB275.
The optical fiber cables featured in this Belden fiber products are third party tested
section have been expanded to meet by either ETL or UL and approved for use
advances in technology and the demands according to the National Electric Code.
of both commercial and industrial
applications. Refer to page 3 for selecting Customer Service
a fiber type, color coding information, and Many fiber designs are available from stock
optical specifications. Belden’s extensive through our Distributors. For your new or
line of indoor and outdoor cable products custom application that you do not locate
is offered in tight buffer and loose tube in this section, contact Customer Service at
designs. Armored, burial, and ruggedized 1-800-Belden-1 (800.235.3361) for additional
designs are suited to a host of industrial information or to request a quote. Further
environments. For each product design, product and technical information is also
items for OM1, OM2, OM3, OM4, and OS2 available on our web site at
(Singlemode) items have been developed. www.belden.com.
Specifications
Zip Cord (900µm Fiber)
Tensile Strength
Fiber Cable OD Weight
Bend Radius (vs. Cable OD) Description Construction Fiber Operation Installation
Count
mm in. Kg/km lb/1000 ft. N lbs-f N lbs-f
Installation 15 x OD
1 2.0 0.08 4 3
Operation 10 x OD Simplex
Simplex 900 µm
66 15 220 50
TB
Temperature Range 1 3.0 0.11 7 5
12-Fiber Standard
24-Fiber Configurations
Round Round
Belden Part Number
Fiber Count
OM3 Aqua OM4 Erika Violet OS2 Yellow
Mini-Round 2.0 mm - Plenum
2 FI3I002P0 FI4I002P0 FISI002P0
8 FI3I008P0 FI4I008P0 FISI008P0
12 FI3I012P0 FI4I012P0 FISI012P0
Color-coded
4 900 µm
TB 2.0 8.2 0.32 52 35 755 170 1535 345 4-fibto 140°F
32°F
2-fiber
Sub-Units 4-fiber Installation (Riser) -10°C to 60°C
2-fiber 4-fiber (14°F to 140°F)
6 9.1 0.36 80 54 1025 230 2070 465
er (Plenum/LSZH)
2-fib
Operation -20°C to 70°C
8 10.3 0.41 103 69
900 µm 2.0 (32°F to 158°F)
10 TB 11.6 0.46 128 86 1335 300 2670 600 Operation (Riser) -20°C to 70°C
12 13.1 0.51 164 110 (-4°F to 158°F)
Above specifications provide 6-fiber
6-fiber
a12-fiber 12-fiber
general representation for the product family. Improved specifications may exist for Riser, Plenum or
LSZH constructions. Consult individual technical data sheets for exact specifications. Legend
6-fiber 12-fiber Rip Cord
Belden Part Number Color-coded Sub-Unit
Fiber Count
OM1 Orange OM3 Aqua OM4 Erika Violet OS2 Yellow Aramid Yarn
36-fiber
36-fiber
Indoor Specifications
Sub-Unit Cable OD Tensile Strength
Bend Radius (vs. Cable OD) Fiber Weight
Description Construction Fiber OD
Count Operation Installation
Installation 15 x OD
mm mm in. Kg/km lb/1000 ft. N lbs-f N lbs-f
Operation 10 x OD
900 µm
2 N/A 4.8 0.19 22 15 222 50 556 125
Temperature Range TB
Storage -40°C to 70°C 4 25 17
2-Fiber 4.8 0.19 222 50 556 125
(-40°C to 158°F) (Non-Unized) 6 24-Fiber 31 21
Non-Unitized
Installation (Plenum/LSZH) 0°C to 60°C 8 (Non-Unized) 36 24
2-Fiber 10 900 µm 5.8 0.23 39 26 334 75 667 150
(32°F to 140°F) N/A
(Non-Unized) TB 24-Fiber
12 (Non-Unized) 43 29
Installation (Riser) -10°C to 60°C2-Fiber 2-Fiber 16 64 43
(14°F to 140°F) (Non-Unized) 24-Fiber 8.8 0.35 556 125 1112 250
2-Fiber (Non-Unized) 24-Fiber
(Non-Unized)
24 (Non-Unized) 80 54
Operation (Plenum/LSZH) -20°C to 70°C
(Non-Unized)(32°F to 158°F) 2-Fiber
24-Fiber
6-Fiber
Operation (Riser) 4.5mm-20°C
(Non-Unized)
to 70°C 6-Fiber
Subunit 4.5mm Subunit
(Non-Unized)
24-Fiber
(Non-Unized)
24 13.1 0.52 145 97 1001 225 2002 450
(-4°F to 158°F) 6-Fiber
Unitized
4.5mm Subunit 900 µm
6-Fiber 24-Fiber 4.5
Sub-Units24-Fiber 4 x 6-fiber
6-Fiber TB
Legend
4.5mm Subunit 4 x 6-fiber24-Fiber 36-Fiber 6-Fiber
6-Fiber 4 x 6-fiber 36-Fiber
6 x 6-fiber 2-Fiber 4.5mm Subunit
36 36-Fiber
x 6-fiber 16.0 0.63 221 148 1668 375 3336 750
2-Fiber (Non-Uni
zed)
66x 6-fiber
4.5mm Rip
Subunit
Cord (Non-Unized) 24-Fiber 24-Fiber
(Non-Unized) (Non-Uni
zed)
2-Fiber
24-Fiber 2-Fiber
(Non-Unized) 24-Fiber
(Non-Uni
zed) 24-Fiber
Numbered Sub-Unit 24-Fiber (Non-Unized) (Non-Uni
zed)
4 x 6-fiber
4 x 6-fiber 36-Fiber
36-Fiber
Aramid Yarn
Central6-Fiber
Strength
6 x66-fiber
x 6-fiber
6-Fiber
4.5mm Subunit 6-Fiber
4.5mm Subunit 6-Fiber 4.5mm Subunit
Member 4.5mm Subunit
36 14.1 0.56 162 109 1001 225 2002 450
24-Fiber 24-Fiber
24-Fiber 24-Fiber
900 µm Tight Buffered 4 x 6-fiber
36-Fiber 4 x 6-fiber
4 x 6-fiber
4 x 6-fiber 36-Fiber
36-Fiber 36-Fiber
Fiber 12-Fiber
12-Fiber 6 x 6-fiber 6 x 6-fiber
6 x 6-fiber 6 x 6-fiber
5.5mm
5.5mmSubunit
Subunit 36-Fiber
36-Fiber
Outer Jacket 33x x12-fiber
12-fiber 48 15.5 0.61 207 139 1423 320 2847 640
12-Fiber
12-Fiber
24-Fiber 12-Fiber
5.5mm
SubunitSubunit
Unitized
12-Fiber 36-Fiber
36-Fiber 12-Fiber
72 900 µm 5.5
96-Fiber
19.0
96-Fiber
8 x 12-fiber 0.75
8 x 12-fiber 321 216 2002 450 5.5mm
4226
12-Fiber 950
5.5mm Subunit
Compliance 5.5mm
TB
12-Fiber Subunit
4 x 6-fiber Sub-Units
12-Fiber 5.5mm Subunit
12-Fiber 3 x 12-fiber 5.5mm Subunit 3 x 12-fiber36-Fiber 36-Fiber
36-Fiber
5.5mm Subunit 36-Fiber 3 x 12-fiber 36-Fiber 3 x 12-fiber
• TIA/EIA-568-C.3 3 x 12-fiber 96 22.8 0.90 536 360 2780 625 55603 x 12-fiber
1250
5.5mm Subunit 36-Fiber 96-Fiber 96-Fiber
8 x 12-fiber
9
96-Fiber 8x
• ISO/IEC 11801, 2nd Edition
6 x 6-fiber 8 x 12-fiber 96-Fiber 96-Fiber
3 x 12-fiber 8 x 12-fiber 8 x 12-fiber
• REACH EC1907-2006
• NEC/CEC OFxR/OFx FT.4 (RISER - PVC) 144-Fiber
Above specifications provide12ax general
12-fiber representation for the product family. Improved specifications may exist for Riser, Plenum or 144-Fiber
• NEC/CEC OFxR/OFx FT.4 (LSZH - FRPE) LSZH constructions. Consult144-Fiber
144-Fiber
individual technical data sheets for exact specifications. 12 x 12-fiber
12 x 12-fiber
• NEC/CEC OFxR/OFx FT.6 (PLENUM - PVC or PVDF) 12 x 12-fiber
144-Fiber 144-Fiber
12 x 12-fiber
12 x 12-fiber
• ICEA S-83-596 144-Fiber
12 x 12-fiber
144-Fiber 144-Fiber
12 x 12-fiber 12 x 12-fiber
42
36-Fiber 1.800.BELDEN.1 (800.235.3361) www.belden.com
3 x 12-fiber
Faster.
Easier.
Better.
96-Fiber
8 x 12-fiber
144-Fiber
12 x 12-fiber
2-Fiber
2-Fiber (Non-Uni
zed)
24-Fiber 24-Fiber
(Non-Unized)
(Non-Unized) (Non-Uni
zed)
6-Fiber
6-Fiber 144-Fiber 4.5mm Subunit
4.5mm Subunit 12 x 12-fiber
24-Fiber
144-Fiber
4 x 6-fiber FiberExpress Distribution Cables (continued)
36-Fiber
2-Fiber
(Non-Unized) 24-Fiber
24-Fiber
4 x 6-fiber
2-Fiber
(Non-Uni
zed)
36-Fiber 24-Fiber
12 x 12-fiber
Tight Buffer — Indoor/Outdoor Riser, Plenum and LSZH Rated
6 x 6-fiber (Non-Unized) 6 x 6-fiber (Non-Uni
zed)
144-Fib
12 x 12-fi
6-Fiber
Indoor/Outdoor Specifications
6-Fiber
4.5mm Subunit
4.5mm Subunit
• Environmental
24-FiberProtection
12-Fiber
5.5mm Subunit
24-Fiber
12-Fiber 4 x 6-fiber 4 x 6-fiber
36-Fiber 36-Fiber
5.5mm Subunit 36-Fiber
3 x 12-fiber
– UV Resistant Jacket 6 x 6-fiber 36-Fiber
3 x 12-fiber
6 x 6-fiber
– Moisture 96-Fiber
Resistant Jacket 96-Fiber
8 x 12-fiber
FDSD096PK, Optical Fiber Indoor/Outdoor Distribution Cable – Fungus Resistant Jacket 8 x 12-fiber
– Subunit
Water Blocking Tape
12-Fiber 5.5mm Subunit
5.5mm 36-Fiber 36-Fiber
3 x 12-fiber 3 x 12-fiber
Compliance
24-Fiber 24-Fiber
12-Fiber
4 x 6-fiber
5.5mm12-Fiber
Subunit 36-Fiber 24-Fiber
4.5mm Subunit
6-Fiber
4.5mm Subunit
6 x 6-fiber 436-Fiber
x 6-fiber
4 x 6-fiber
36-Fiber
24-Fiber
5.5mm Subunit 336-Fiber
x 12-fiber 6 x 6-fiber
36-Fiber
4 x 6-fiber 24-Fiber
• TIA/EIA-568-C.3 3 x 12-fiber
4 x 6-fiber
36-Fiber
6 x 6-fiber 36-Fiber
48 15.5 0.61 207 139 1423 320 2847 640 6 x 6-fiber
• Telcordia GR-20-CORE
12-Fiber
5.5mm
5.5mm Subunit
Subunit 6 x 6-fiber
Unitized
36-Fiber12-Fiber 72 900 µm
96-Fiber
96-Fiber
8 19.0 0.75
x 12-fiber 321 216 2002 450 4226 950
12-Fiber 3 x 12-fiber
36-Fiber
12-Fiber TB 5.58 x 12-fiber
Sub-Units 12-Fiber
• RoHS II 2011/65/EU 5.5mm Subunit 36-Fiber
5.5mm Subunit
3 x 12-fiber3 36-Fiber 5.5mm Subunit
12-Fiber
3 x 12-fiber x 12-fiber
96 22.8 0.90 536 36012-Fiber2780 62512-Fiber
5560 1250
5.5mm Subunit
• REACH EC1907-2006
5.5mm Subunit
96-Fiber 96-Fiber
5.5mm Subunit
36-Fiber
36-Fiber
3 x 12-fiber
36-Fiber 96-Fiber 8 x 12-fiber 8 x 12-fiber 3 x 12-fiber
• NEC/CEC OFxR/OFx FT.4 (RISER - PVC) 3 x 12-fiber
8 x 12-fiber
96-Fiber 96-Fiber
96-Fiber
8 x 12-fiber
8 x 12-fiber
• NEC/CEC OFxR/OFx FT.4 (LSZH - FRPE) 144 8 x 12-fiber
25.4 1.00 602 404 4226 950 8452 1900
• NEC/CEC OFxR/OFx FT.6 (PLENUM - PVC or PVDF)
96-Fiber
• ICEA S-104-696 8 x 12-fiber
144-Fiber
144-Fiber
Above specifications provide ax general
12-fiber representation for the product family. Improved specifications may exist for Riser, Plenum or
12 x 12-fiber
12144-Fiber
144-Fiber
LSZH constructions.
12 x 12-fiber
Consult
12individual
x 12-fibertechnical data sheets for exact specifications. 144-Fiber
12 x 12-fiber
144-Fiber
144-Fiber 12 x 12-fiber
12 x 12-fiber
36-Fiber
3 x 12-fiber 144-Fiber
12 x 12-fiber
144-Fiber
44 12 x 12-fiber 1.800.BELDEN.1 (800.235.3361) www.belden.com
96-Fiber
Faster.
Easier.
Better.
(32°F to 140°F)
6-Fiber 2-Fiber 24 21.5 0.85 391 263
Installation (Riser) -10°C to 60°C 4.5mm Subunit
(Non-Uni
zed)
2-Fiber
24-Fiber
(Non-Uni
zed)
(14°F
6-Fiber
to 140°F)
4.5mm Subunit
Unitized
24-Fiber
(Non-Uni
zed)
(Non-Uni
zed) 2-Fiber 900 µm
2-Fiber
6-Fiber (Non-Uni
zed) 4.5 890 200 2700 600
Operation
(Non-Unized)
(Plenum/LSZH)
24-Fiber
-20°C to 70°C 24-Fiber
24-Fiber
TB
Sub-Units (Non-Uni
zed)
2-Fiber
(Non-Unized)
4 x 6-fiber
(32°F 6-Fiber
to 158°F) 24-Fiber
36-Fiber
Compliance
4 x 6-fiber
• TIA/EIA-568-C.3
36-Fiber
144-Fiber 144-Fiber
144-Fiber
• Telcordia GR-409-CORE 12 x 12-fiber
• RoHS II 2011/65/EU
• REACH EC1907-2006
• NEC/CEC OFxR/OFx FT.4 (RISER - PVC)
• NEC/CEC OFxR/OFx FT.4 (LSZH - FRPE)
• NEC/CEC OFxR/OFx FT.6 (PLENUM - PVC or PVDF)
• ICEA S-83-596
2-Fiber
(Non-Uni
zed) 24-Fiber
(Non-Uni
zed)
2-Fiber
(Non-Uni
zed) 24-Fiber
(Non-Uni
zed)
-Fiber
6-Fiber
36-Fiber
Uni
zed)
mm Subunit
2-Fiber 6-Fiber
4.5mm Subunit
(Non-Uni
zed) 24-Fiber
24-Fiber
3 x 12-fiber
(Non-Uni
zed)
4 x 6-fiber
36-Fiber
46 6 x 6-fiber
1.800.BELDEN.1 (800.235.3361)
24-Fiber www.belden.com
4 x 6-fiber 36-Fiber
6 x 6-fiber
6-Fiber
4.5mm Subunit
Faster.
Easier.
Better.
6-Fiber
4.5mm Subunit
24-Fiber 24-Fiber
4 x 6-fiber 12-Fiber 4 x 6-fiber
36-Fiber 36-Fiber
6 x 6-fiber 5.5mm Subunit 6 x 6-fiber
36-Fiber
3 x 12-fiber
144-Fiber
er 12 x 12-fiber 96-Fiber
fiber 144-Fiber 8 x 12-fiber
96-Fiber 96-Fiber
8 x 12-fiber 8 x 12-fiber
Indoor/Outdoor Specifications
• Environmental Protection
144-Fiber
12 x 12-fiber – UV Resistant Jacket
FD4D096AK, Optical Fiber Armored Distribution Cable, – Moisture Resistant Jacket
144-Fiber
12 x 12-fiber
Indoor/Outdoor – Fungus Resistant Jacket
144-Fiber
– Water Blocking Aramid 12 x 12-fiber
2-Fiber
ni
zed) 24-Fiber
(Non-Uni
zed)
2-Fiber
24-Fiber (-40°F to 158°F) Unitized
2-Fiber
24-Fiber(Non-Uni
zed)
36-Fiber
3 x 12-fiber
Interlocking Armor
96-Fiber144 35.6 1.40 1005 675
Outer Jacket 8 x 12-fiber
24-Fiber
144-Fiber
144-Fiber
12 x 12-fiber
Compliance
12 x 12-fiber
4 x 6-fiber
• TIA/EIA-568-C.3
Above
36-Fiber
specifications provide 12a144-Fiber
144-Fiber
LSZH
xgeneral
12-fiber representation for the product family. Improved specifications may exist for Riser, Plenum or
constructions. Consult individual technical data sheets for exact specifications.
12 x 12-fiber
36-Fiber
3 x 12-fiber
48
96-Fiber
1.800.BELDEN.1 (800.235.3361) www.belden.com
8 x 12-fiber
Faster.
Easier.
Better.
Hybrid cables combine multiple grades of fiber in a single unitized cable easily supporting
various applications in a single cable which minimize installation labor.
Standard Hybrid
Image for Page 44
Cable
INDOOR Color
STANDARD COLORS INDOOR/OUTDOOR STANDARD COLORS
OS2/OM4 OS2/OM4
Rip Cord
For an exhaustive selection contact Belden customer service or your local Belden Representative for more details.
Examples:
FIHDH22PJ - Unitized − 6 fiber subunits and for FDEDH31AK's description to say Unitized 12 fiber subunits.
FDEDH31AK - FX Indoor/Outdoor Cable, Hybrid Distribution Tight Buffered Cable, Unitized, 48 fiber (36 fiber OS2, 12 fiber OM4),
Plenum Armored, Black Jacket
Lightweight and easy to handle Belden Reel-In-A-Box simplifies fiber cable payout.
Rugged box construction and locking reel hub ensures both the box and fiber arrive on
the job site intact and the adjustable hub tension always results in the optimal pulling
condition.
Standard Configurations
Belden Part Number
Fiber Count
OM1 Orange OM3 Aqua OM4 Erika Violet OS2 Yellow
1000 ft. Box – Interconnect (3 mm Zip Cord), Plenum
1 FI1I001PCOBK FI3I001PCABK FI4I001PCEBK FISI001PCYBK
2 FI1I002PCOBK FI3I002PCABK FI4I002PCEBK FISI002PCYBK
1000 ft. Box – Breakout, Plenum
2 FI1B002PBOBK FI3B002PBABK FI4B002PBEBK FISB002PBYBK
4 FI1B004PBOBK FI3B004PBABK FI4B004PBEBK FISB004PBYBK
1000 ft. Box – Distribution, Plenum
2 FI1D002P9OBK FI3D002P9ABK FI4D002P9EBK FISD002P9YBK
4 FI1D004P9OBK FI3D004P9ABK FI4D004P9EBK FISD004P9YBK
6 FI1D006P9OBK FI3D006P9ABK FI4D006P9EBK FISD006P9YBK
12 FI1D012P9OBK FI3D012P9ABK FI4D012P9EBK FISD012P9YBK
1000 ft. Box – uMini-Distribution, Plenum
12 FI1M012P2OBK FI3M012P2ABK FI4M012P2EBK FISM012P2YBK
For an exhaustive selection contact Belden customer service or your local Belden Representative for more details.
36 fiber
(-40°C to 158°F) 2424 fiber
fiber 16 fiber
24 16 fiber
(32°F to 140°F)
36 fiber
Installation (Riser) -10°C to 60°C 3636
fiber
fiber
36 24 fiber 24 fiber
24 fiber
36 fiber 24 fiber 6.5 0.26 38 26
(14°F to 140°F)
PagePage
44Page
Legend
4444Legend
Legend
3636 fiber
fiber 2424 fiber
fiber
Page 44 Legend
Page 44 Legend
Operation (Plenum/LSZH) -20°C to 70°C Page
Page 4444 Legend
Legend
MINI-DISTRIBUTION
Rip Cord
MINI-DISTRIBUTION
MINI-DISTRIBUTION
Base 12 INDOOR
36 fiber
Base 12 INDOOR
Base 12 INDOOR
24 fiber
Central Strength
UnitSub UnitMember
MINI-DISTRIBUTION
Numbered
Numbered Sub
4848fiber
36 fiber
Rip
Rip Cord 250um Fiber
Cord
Numbered Sub Unit
48 32 fiber
24 fiber
Aramid Yarn
Aramid Yarn
fiber 32 fiber
12 INDOOR
Base 12 INDOOR
Filler
Central
Numbered
Numbered Unit
Strength
SubFiberSub UnitMember
Unit
250um
250um Fiber
48 fiber
OuterYarn
Jacket
32 fiber
Aramid
Central Strength Member
Central Strength Member
Filler Unit
Aramid
Outer Jacket
Unitized
Outer Jacket
250um Fiber
Base
250um Filler
Fiber Unit
Outer
Filler
Filler Unit UnitJacket
Page 46 Legend
Outer Jacket
Outer Jacket
Page 44 Legend
(-4°F to 158°F)
Page 46 Legend 12-Fiber 250 µm 200.3 45 668 150
Page Page
46 Legend
46 Legend 72 fiber 48 fiber
MINI-DISTRIBUTION
Page
Page 4646 Legend
Legend
Sub-Units
Rip Cord
MINI-DISTRIBUTION
72 fiber 48 fiber
Base 8 INDOOR
2.0
Rip Cord
MINI-DISTRIBUTION
Rip Central
Cord Strength Member
72 fiber
72 fiber 48 fiber48 fiber
Legend 7272 fiber
fiber
72 4848 fiber
fiber
7.5 0.30 54 36
Base 12 INDOOR
MINI-DISTRIBUTION
Aramid Yarn
MINI-DISTRIBUTION
Base 8 INDOOR
RipRip
Cord
CordRip 250um Fiber
Cord
Central Strength Member
INDOOR
Filler Unit
Base8 8INDOOR
Base 8 INDOOR
Numbered
Numbered Sub
AramidSub Unit
Numbered Sub Unit
Unit
Yarn
Central
OuterStrength
Jacket Member
Base 12 INDOOR
48 fiber
Central
Central Central
Strength
Strength
250um Strength
Member
Member
Fiber Member
32 fiber
Aramid
Numbered SubYarn
Unit
Aramid Yarn
AramidAramid
Yarn Yarn
Aramid YarnFiller
250um UnitFiber
Base
250um250um
Fiber Fiber
250um Fiber 250um Fiber Outer Jacket
Filler Unit
Central Strength Member Filler Unit
Filler Unit
Rip Cord
Outer Jacket
Rip Cord
Filler UnitOuter
Filler Unit Outer Jacket Jacket
Aramid Yarn
250um Fiber
Outer Jacket
Outer Jacket
96 fiber
48 fiber 32 fiber
64 fiber
Filler Unit
Numbered
Numbered Sub-Unit Sub Unit
Outer Jacket 96 fiber
96
9696 fiber
fiber
fiber
96 6464
64 fiber
64 fiber
fiber
fiber 8.7 0.34 72 49
Page 46 Legend 96 fiber 64 fiber
Central Strength
Central Strength Member
Member
Page 46 Legend 72 fiber 48 fiber
48 fiber
MINI-DISTRIBUTION
AramidAramid
Yarn Yarn Rip Cord
96 fiber
144 fiber
Base 8 INDOOR
250um
Buffered Fiber
Fiber Numbered
Aramid Yarn
250um Fiber
144144
144 fiber
fiber
fiber
144 fiber 144 9696 9696
fiber
fiber fiber
fiber 9.9 0.39 80.5 54.1
Base 8 INDOOR
Sub Unit
Filler Unit
Central Strength Member
Filler Unit
Outer Jacket
Filler Unit Aramid Yarn 144 fiber 96 fiber
250um Fiber
Outer Jacket
Filler Unit
Outer Jacket Outer Jacket
Above specifications provide a general representation for the product family. Improved specifications may exist for Riser, Plenum or
Compliance LSZH constructions. Consult individual technical data sheets for exact specifications.
Page 46 Legend
Non-unitized - Plenum
• REACH EC1907-2006
12 FI3M012P2 FI4M012P2 FISM012P2
• NEC/CEC OFxR/OFx FT.4 (RISER - PVC) Double-Jacket Unitized - Plenum
• NEC/CEC OFxR/OFx FT.4 (LSZH - FRPE) 12 FI3M012P0 FI4M012P0 FISM012P0
144 fiber 96 fiber
• NEC/CEC OFxR/OFx FT.6 (PLENUM - PVC or PVDF) Unitized - Plenum
• ICEA S-83-596 24
36
144 fiber
FI3M024P1
FI3M036P1
FI4M024P1
FI4M036P1
96 fiber
FISM024P1
FISM036P1 72 fiber
48 FI3M048P1 FI4M048P1 FISM048P1
Rip Cord
72 FI3M072P1 FI4M072P1 FISM072P1
Numbered Sub Unit 144 FI3M144P1 FI4M144P1 FISM144P1
For an exhaustive selection contact Belden customer service or your local Belden Representative for more details.
Central Strength Member Outer Jacket
Strength Elements
Buffer Tube
Aramid Yarn
Water Swellable Aramid Yarn Aramid Yarn
Outer Jacket
52
Outer Jacket
Outer Jacket
Buffer Buffer
Tube Tube
250um Fiber
Water Water
OuterSwellable
Swellable AramidAramid
Jacket Yarn Yarn AramidAramid
Yarn Yarn
Corrugated
Corrugated Steel Armor
Steel Elements
Strength Armor 900um900um Tight Buffered
Tight Buffered Fiber Fiber
BufferJacket
Outer Tube Outer Jacket
Outer Jacket
Water Swellable
Strength ElementsAramid Yarn Aramid Yarn
Corrugated
Buffer Tube Steel Armor 900um Tight Buffered Fiber
Outer JacketYarn
Filler Unit
Water Swellable Aramid Yarn Aramid
Outer Jacket
Faster.
Easier.
Better.
Page 44 Legend
MINI-DISTRIBUTION
Indoor Riser and Plenum Rated Rip Cord
Base 12 INDOOR
Numbered Sub Unit
Base8 Indoor Specifications
Central Strength Member
Sub-Unit Tensile Strength lsb-f
Cable OD Weight Bend Radius (vs. Cable OD)
Fiber OD Operation Installation Aramid Yarn
Name Construction Fiber
Count Installation 15 x OD
lb/1000
mm mm in. Kg/km N lbs-f N lbs-f 250um Fiber
Page 4444
Page Missing Pictures
Missing Pictures Page
Page46
46Missing
Missing Pictures
Pictures ft. Operation 10 x OD
Page 44 Missing Pictures
Indoor fiber µMini-Distribution
1212fiber
Page 44 Missing Pictures
Page 46 Missing Pictures Cable
Page 46 Missing Pictures8 fiber Temperature Range Filler Unit
Page
Page 4444 MissingPictures
Missing Pictures 12 fiberPage Page 4646 Missing
Missing Pictures
8 fiber
Pictures
12 fiber
Non- 8 fiber Storage Outer Jacket
-40°C to 70°C
1212fiber
Page 44 Missing
fiber1212fiber
Unitized
Pictures
fiber 8888fiber
fiber 8 250 µm
fiber
fiber
12 fiberPage 46 Missing Pictures 8 fiber
N/A 3.0 0.12 9 6 200.3 50 445 100
(-40°C to 158°F)
1212 fiber
fiber 8 fiber
8 fiber Installation (Plenum/LSZH) 0°C to 60°C
Unitized
12 fiber2424fiber
fiber
24 fiber 168fiber
fiber
16 fiber
16 fiber (32°F to 140°F)
12 fiber
8-Fiber
12 fiber 8 fiber 8 fiber
8 250 µm 3.0 4.8 0.18 11 7 200.3 45 668 150
24 fiber
Sub-Units 16 fiber Installation (Riser) -10°C to 60°C
(14°F to 140°F)
Page 46 Legend
24 fiber 16 fiber
24 fiber 16 fiber Operation (Plenum/LSZH) -20°C to 70°C
24 fiber
3636 fiber
fiber 24 16
24fiber
fiber24fiber
36 fiber 24 fiber (32°F to 158°F)
egend 36 fiber 24 fiber
Operation (Riser) -20°C to 70°C
Rip Cord
36 fiber
6.5 0.26 38 26 (-4°F to 158°F)
ip Cord Numbered Sub Unit 24 fiber
umbered Sub Unit
Central Strength Member
32 fiber32
ramid
rd Yarn
48 fiber
MINI-DISTRIBUTION
24 fiber
32 fiber
d Yarn
Rip Cord
m Fiber
tNumbered Sub Unit
nit
egend
Central Strength Member
Rip Cord
Jacket
Aramid Yarn
250um Fiber
48 fiber 32 fiber Rip Cord
Filler Unit
Outer Jacket
72 fiber 48 fiber
Base 8 INDOOR
Rip Cord
72 fiber 48 fiber
Numbered
Sub-Unit Sub Unit
Numbered Sub Unit
72 fiber
Numbered
umbered Sub Unit
Aramid Yarn
48 fiber
250um Fiber
entral Strength Member 72 fiber 48
48 fiber 7.5 0.30 54 36
CentralCentral
StrengthStrength Member
Filler Unit
48 fiber 32 fiber
ramid Yarn
rd Unit
Sub Outer Jacket
Unitized
72 fiber
50um Fiber
48 fiber
ered Sub
ength Unit
Member
ler Unit
al
n Strength Member
Rip Cord
uter Jacket
Member
8-Fiber 32 fiber 250 µm 2.0 200.3 45 668 150
d Yarn
er
48 fiber
Numbered Sub Unit
AramidAramid
Yarn Yarn
m Fiber
Central Strength Member
tnit
Sub-Units
Aramid Yarn
Jacket
250um Fiber
Strength Elements
Buffer Tube
Outer Jacket
All Dielectric Loose
Single Jacket, All Dielectric Loose
Loose
Rip Cord
Tube
Dielectric
Central Strength Member
Rip Cord
Rip Cord
Jacket,
250um Fiber
Numbered
Numbered Sub UnitSub Unit
SingleAll
CentralCentral
StrengthStrength
MemberMember
Single Jacket,
Moisture
250um Fiber Blocking Gel
250um Fiber
Outer Jacket
Outer Jacket
Moisture Blocking Gel
Moisture Blocking Gel
Rip Cord
tube
Central Strength Member
Rip Cord
Jacket,
250um Fiber
loose
Outer Jacket
Singletube
Numbered
Outer Sub Unit
Jacket
Outer Jacket
tube
FiberExpress All Dielectric Loose Tube Cables
RipRip
Cord
Cord Strength Member
Central
Armored
loose
Moisture Blocking Gel
Rip Cord
Numbered
NumberedSubSubUnit
Armored loose
Unit
Tube
250um Fiber
Numbered Sub Unit
Central Strength
Central StrengthMember
Member
Armored
Inner Jacket
Central Strength Member
DutyDuty
Numbered Sub Unit
Steel Corrugated Armor
Outer Jacket
Heavy
Rip
Outer Cord
Jacket
Outer Jacket
250um Fiber
Jacket
Central
Numbered
Numbered Strength
Moisture
Sub
Rip Cord
Sub Unit Member
Blocking
Unit Gel
Jacket
Central
Steel
250um Strength Member
Corrugated Armor
FiberMember
Central Strength
Double
• Inter-building duct installations
250um Fiber
Inner
250um Jacket
Fiber
Central Strength Member
Double
Inner Jacket
FSSL096NG, Optical Fiber All Dielectric Loose Tube Cable, Outdoor Moisture
AramidBlocking Gel Member
Strength
• Lashed aerial
Inner
Steel
Rip Jacket Armor
Corrugated
Cord
Aramid Strength Member
Aramid
250um Strength Member
Fiber
Inner Jacket
6 Fiber
12
4848Pictures
6 Fiber
12 to 48 Fiber
12 to 48 Fiber 10.5 0.4112 to 48 Fiber
87
12 to 48 Fiber
59 12 to 48 Fiber
and 50 Pictures
36 12 to 48 Fiber
50 Pictures
48 Pictures
48 12 to 48 Fiber 12 to 48 Fiber
Page 51 Pictures
Page 49 and 50 Pictures
and
51 Pictures
12 to 48 Fiber
4747
12 to 48 Fiber
andand
Specifications
12 to 48 Fiber
50Pictures
Page
51 Pictures
Page
and
Page 51 Pictures
50 49
Page 51 Pictures
Temperature Range (Outdoor Series) 72 Fiber
Page
and49
72 Fiber
Page
72 Fiber
PagePage
72 Fiber
Storage -40°C to 75°C
Page
Page 49 and
72 Fiber
Page
72 Fiber
72 Fiber
Operating -40°C to 70°C Unitized
49
72 Fiber 72 Fiber
72
72Fiber
Fiber
72 Fiber
72 Fiber
Page
12-Fiber 2700
72 Fiber72 Fiber
600 890 200
Min. Bend Radius
Sub-Units 96 13.2 0.52 136 91
Installation 20 x OD
Long Term 15 x OD 96-Fiber
96-Fiber 96-Fiber
8 x 12-fiber 8 x 12-fiber
8 x 12-fiber
96-Fiber 96-Fiber
96-Fiber
8 x 12-fiber
Legend 8 x 12-fiber
96-Fiber
96-Fiber
96-Fiber96-Fiber
96-Fiber
8 x 12-fiber
96-Fiber
8 x 12-fiber
96-Fiber
896-Fiber
x 12-fiber 8 x 12-fiber 96-Fiber
8 x 12-fiber
88 xx 12-fiber
12-fiber 8 x 12-fiber 8 x 12-fiber
8 x 12-fiber
6 Fi
Outer
Buffer Jacket
Corrugated Steel Armor
Tube
900um Tight Buffered Fiber
Moisture Blocking
Moisture6Blocking Agent
Buffer Tube
Strength
Corrugated
Outer Elements
Steel Armor
Jacket 900um Tight Buffered Fiber
Aramid Yarn
Aramid Yarn
FS4L006NF FSSL006NF
Buffer Steel Aramid
Tube
Corrugated Armor Yarn 900um Tight Buffered Fiber
Outer Jacket
Aramid
Outer Yarn
Jacket FS4L012NG FSSL012NG
FS1L024NG FS2L024NG FS3L024NG FS4L024NG FSSL024NG
900um Tight Buffered Fiber
24
Corrugated Steel Armor
Outer Jacket
Tube
Dielectric
Central Strength Member
Rip Cord
Rip Cord
Jacket,
250um Fiber
Numbered
Numbered Sub UnitSub Unit
SingleAll
CentralCentral
StrengthStrength
MemberMember
Outer Jacket
Outer Jacket
Moisture Blocking Gel
Moisture Blocking Gel
Rip Cord
Outer Jacket
tube
250um Fiber
loose
Outer Jacket
Singletube
Numbered
Outer Sub Unit
Jacket
Outer Jacket
tube
Unit
Tube
250um Fiber
Numbered Sub Unit
Central Strength
Central StrengthMember
Member
Armored
Inner Jacket
Steel
OuterCorrugated
Jacket Armor
MoistureInner
Moisture JacketGel
Blocking
Blocking Gel
Rip Cord
Moisture Blocking
Steel Corrugated Armor Gel
DutyDuty
Rip
Outer Cord
Jacket
Outer Jacket
250um Fiber
Armored loose tube
Double Jacket Heavy Duty
Heavy
Numbered
Rip RipOuter
Cord Sub Unit
Jacket
CordJacket
Central
Numbered
Numbered Strength
Moisture
Sub
Rip Cord
Sub Unit Member
Blocking
Unit Gel
Jacket
Central
Steel
250um Strength Member
Corrugated Armor
FiberMember
Central Strength
Inner Jacket
Double Jacket Heavy Duty
InnerMoisture
Jacket Blocking Gel
Aramid
250um Strength Member
Fiber
Inner Jacket
6 Fiber
4848Pictures
12 6 Fiber
12 to 48 Fiber
12 to 48 Fiber 12.9 0.51
12 to 48 Fiber
164 110 12 to 48 Fiber
and 50 Pictures
12 to 48 Fiber
36 12 to 48 Fiber
50 Pictures
48 Pictures
48 12 to 48 Fiber 12 to 48 Fiber
Page 51 Pictures
Page 49 and 50 Pictures
and
51 Pictures
12 to 48 Fiber
4747
12 to 48 Fiber
andand
Ratings
12 to 48 Fiber
50Pictures
Page
51 Pictures
Page
and
Page 51 Pictures
50 49
Page 51 Pictures
72 Fiber Riser
Page
and49
72 Fiber
Page
72 Fiber
PagePage
72 Fiber
UL Type OFNR
Page
Page 49 and
72 Fiber
Page
72 Fiber
72 Fiber
Unitized cUL Type OFN FT4
49
72 Fiber 72 Fiber
72
72Fiber
Fiber
72 Fiber
72 Fiber
Flame Resistance UL 1666
Page
Bundle
Water Swellable Aramid Yarn
Strength Elements
Outer
Buffer Jacket
Corrugated Steel Armor 900um Tight Buffered Fiber
Strength Elements
OuterSwellable
Water Jacket Aramid Yarn Outer Jacket
Aramid Yarn Unit
Riser (NEC/CEC OFNR/OFN FT.4) Indoor/Outdoor — Gel Filled Buffer Tubes Buffer Tube
Strength
Corrugated
Outer
Buffer
Elements
Steel Armor
Jacket
TubeElements
900um Tight Buffered Fiber
Outer Jacket
www.belden.com 1.800.BELDEN.1 (800.235.3361) 55
Strength Elem
Drawings for Single Jacket, Sin
Armor Page
Jacket Specifications
Moisture Blocking Agent
Drawings for Single Jacket, Single
Armor Page
Drawings for Single Jacket, Single
Tensile Strength lsb-f
6 Fiber
Drawings for Single
Armor Jacket, Single
Page
Armor Page
Fiber Cable OD Weight
Name Construction
Drawings for Single Jacket, Single Installation Operation
Jacket Material Armor Page
Count
Single Jacket, All Dielectric Loose
Outdoor PE
Armor Page
Loose
47 47
Rip Cord
All Dielectric
46 and
Single Jacket, All Dielectric Loose
All Dielectric
Rip Cord
46 and
Riser PVC
Numbered Sub Unit
Tube For Pages 46 and 47
250um Fiber
6 Fiber
Tube
Outer Jacket
Central Strength Member
Numbered Sub Unit
Moisture Blocking Agent
6 Fiber
Single
Tube
Outer Jacket
Sub-Units
Moisture Blocking
250um Central Strength Member
FiberAgent
6 Fiber
Single
6 Fiber
Strength Member Aramid Yarn
Outer Jacket
Moisture Blocking Agent
Moisture Blocking Agent 6 Fiber
12
New Legend Picture For Page 52
52 52
Page
Outer Jacket
ForFor
Outer Jacket
StrengthStrength
Elements
Outer Jacket
13.2 0.52 140 94
Picture
Elements
36
Outer Jacket
Outer Jacket
Picture
Strength
Buffer Tube
Buffer Elements
Tube
Outer Jacket
Buffer Tube
Legend
Strength Elements
New Page...Single Jacket, Single
Single
Rip Cord
Corrugated SteelNumbered
Armor Sub Unit
Buffer Tube
48 48
Rip Cord
Armor, Page 48
Jacket,
Rip Cord
Numbered Sub Unit
Rip Cord
Page
Numbered
Central Strength Sub Unit
Member
72 Fiber
Armor,
Specifications
Central Strength Member
Page...Single
Outer Jacket
CentralCentral
250um Strength
Fiber Member
Strength Member
Armor,
250um 250um
Fiber 250um Moisture Blocking Agent
Fiber Fiber
Outer Jacket 72 Fiber
72 Fiber
Water Blocking Gel 72 Fiber
Fiber
Outer Jacket
12 to 48 Fib
Outer Jacket
Outer Jacket
Moisture Blocking Agent
Unitized
New
Moisture Blocking
Moisture Agent
Moisture Blocking
Blocking AgentAgent
Long Term 15 x OD
144 19.6 0.77 285 192
Legend
Corrugated Steel
Armor Corrugated Steel Armor
Above specifications provide a general representation for the product family. Improved specifications may exist for Riser, Plenum or
Rip Cord Rip CordLSZH constructions. Consult individual technical data sheets for exact specifications.
Numbered SubNumbered
Unit Sub Unit
No. of No. of Fibers Belden Part Number
Central Strength Fibers Per Bundle OM1 OM2 OM3 OM4 OS2
Member Central Strength Member
Outside Plant — Gel Filled Buffer Tubes
250 µm Fiber 250um Fiber 6 6 FS1L0066F FS2L0066F FS3L0066F FS4L0066F FSSL0066F
12 12 FS1L0126G FS2L0126G FS3L0126G FS4L0126G FSSL0126G
Outer Jacket Outer Jacket
24 12 FS1L0246G FS2L0246G FS3L0246G FS4L0246G FSSL0246G 72 Fiber
Moisture Blocking 48 12 FS1L0486G FS2L0486G FS3L0486G FS4L0486G FSSL0486G
Agent
Moisture Blocking Agent
Compliance 72 12 FS1L0726G FS2L0726G FS3L0726G FS4L0726G FSSL0726G
96 12 FS1L0966G FS2L0966G FS3L0966G FS4L0966G FSSL0966G
• TIA/EIA-568-C.3
144 12 FS1L1446G FS2L1446G FS3L1446G FS4L1446G FSSL1446G
• ICEA S-87-640
Outside Plant — Dry Buffer Tubes
• GR-20-CORE 6 6 FS1L0066C FS2L0066C FS3L0066C FS4L0066C FSSL0066C
12 12 FS1L0126D FS2L0126D FS3L0126D FS4L0126D FSSL0126D
24 12 FS1L0246D FS2L0246D FS3L0246D FS4L0246D FSSL0246D
48 12 FS1L0486D FS2L0486D FS3L0486D FS4L0486D FSSL0486D
72 12 FS1L0726D FS2L0726D FS3L0726D FS4L0726D FSSL0726D
96 12 FS1L0966D FS2L0966D FS3L0966D FS4L0966D FSSL0966D
144 12 FS1L1446D FS2L1446D FS3L1446D FS4L1446D FSSL1446D
96-Fiber
Faster.
Easier.
Better.
Single Jacket, All Dielectric Loose
Rip Cord
250um Fiber
Outer Jacket
Rip Cord
Single Jacket, All Dielectric
250um Fiber
Central Strength Member
Single Jacket, All Dielectric Loose
Outer Jacket
250um Fiber
Outer JacketJacket
Outer
Moisture Blocking Gel
Armored loose tube
250um Fiber
Outer
Outer Jacket
Jacket
Armored loose tube
Rip Cord
Inner JacketMoisture Blocking Gel
Rip Cord
Numbered
Moisture Sub Gel
Blocking Unit
Numbered Sub Unit
Single Jacket, All Dielectric Loose
OuterMoisture
Jacket Rip
Blocking
Cord GelCentral Strength Member
Moisture Blocking Gel
250um Fiber
Central Strength Member
Double Jacket Heavy Duty
250um Fiber
Aramid Strength
Central
Aramid StrengthMember
Strength Member
Member
Steel Corrugated Armor
Moisture Blocking
RipGel
Cord
Aramid StrengthNumbered
MemberSub Unit
Central Strength Member
250um Fiber
Cable OD Weight
Moisture Blocking Gel
Fiber
Aramid Strength Member
24
Page 47 and 48 Pictures
12 to 48 Fiber 36
Page 47 and 48 Pictures
12 to 48 Fiber
12 to 48 Fiber 12 to 48 Fiber
Armor Corrugated Steel Tape
Pictures
12 to 48 Fiber 12 to 48 Fiber
Pictures
12 to 48 Fiber 12 to 48 Fiber
1212to
to 48 Fiber
48 Fiber 48 12 to 48 Fiber 12 to 48 Fiber
Page 49 and 50 Pictures
Pictures
12 to 48 Fiber
12 to 48 Fiber 12 to 48 Fiber
Color Code (Buffer) Per TIA/EIA 598-B
Page 49 and 50 Pictures
Pictures
Pictures
Page 51 Pictures
Pictures
50
Rip Cord
5050
51 Pictures
51
5151
and
72 Fiber
49
4949
72 Fiber 72 Fiber
Page
Page
72 Fiber
72 Fiber 72
72 Fiber Specifications
Page
Fiber 72 Fiber
Page
72 Fiber
Page
72 Fiber
72 Fiber
72 Fiber
72 Fiber
Page
Unitized 72 Fiber
72 Fiber
Outer Jacket
Outer Jacket
Armored loose tube
Outer Jacket
Strength Elements
Buffer Tube
144-Fiber product family. Improved specifications may exist for Riser, Plenum or
Aramid Yarn
12 x12
12-fiber
x 12-fiber x 12-fiber
x 12-fiber
144-Fiber
144-Fiber 144-Fiber
144-Fiber 144-Fiber Numbered Sub-UnitSub Unit
144-Fiber 12 xx 12-fiber
12 12-fiber 1212
x 12-fiber Numbered
12 x1212-fiber
x 12-fiber x 12-fiber
Outer Jacket
No. of Belden Part Number Central Strength
Central Strength Member
Outer Jacket
Strength Elements
Fibers Per
Water Swellable Aramid Yarn Aramid Yarn
Water Swellable Aramid Yarn Aramid Yarn
Outer Jacket
Bundle
Strength Elements Outer Jacket
Strength Elements Outer Jacket
Buffer Tube
Buffer Tube
Water Swellable Aramid Yarn Aramid Yarn
Outdoor Armored
Water Swellable Aramid Yarn
Corrugated Steel Armor
Corrugated Steel Armor
Aramid Yarn
900um Tight Buffered Fiber
900um Tight Buffered Fiber
Inner Jacket
Inner Jacket
Outer Jacket
250um Fiber
Inner Jacket
Tube
Single Jacket, All Dielectric Loose
Central Strength Member
Tube Loose
250um Fiber
OuterRip
Jacket
Cord
Tube
250um Fiber
Central Strength Member
Moisture
OuterOuter Blocking Gel
JacketJacket
Tube
Numbered Sub Unit
Central Strength Member
Central Strength Member
250um Fiber
Armored loose tube Outer Jacket
250um Fiber
Tube
Gel-filled buffer tubes prevent water Applications:
Inner Jacket
OuterMoisture Blocking
Jacket Rip Cord GelCentral Strength Member
Moisture Blocking Gel
250um Fiber
Steel Corrugated Armor
Rip Cord Numbered Sub Unit
Steel Corrugated Armor
Outer Jacket
250um Fiber
Double Jacket Heavy Duty
Central
OuterStrength
Jacket Member
OuterInner
JacketJacket
SubCorrugated
Unit Armor
Numbered Sub Unit
FDSH0965G, Optical Fiber Loose Tube Cable, Indoor/Outdoor entrance splicing to in-building cable.
Rip Cord
Moisture Blocking
Central StrengthGel
Member
Central Strength Member
Numbered Sub Unit
Aramid Strength
250um Fiber MemberCentral Strength Member
250umOuter Jacket
Fiber
• Indoor/outdoor
Moisture Blocking
Numbered Sub Unit
Moisture Blocking Gel
Outer Jacket
250um Fiber
Inner Jacket
Jacket Specifications
Moisture Blocking Gel
24
Page 47 and 48 Pictures
Corrugated12Steel Tape
to 48 Fiber 36
Page 47 and 48 Pictures
12 to 48 Fiber 12 to 48 Fiber
Pictures
12 to 48 Fiber 12 to 48 Fiber
1212to
to 48
48 Fiber
Fiber 48 12 to 48 Fiber
Page 49 and 50 Pictures
12 to 48 Fiber
Color Code (Buffer) Per TIA/EIA 598-B
Pictures
12 to 48 Fiber
12 to 48 Fiber 12 to 48 Fiber
Page 49 and 50 Pictures
Pictures
Pictures
Page 51 Pictures
Jacket Color
Pictures
Black
50
5050
51 Pictures
51
and
5151
72 Fiber
Ratings
49
72 Fiber
4949
72 Fiber
Page
72 Fiber
Page
72 Fiber 72 Fiber
Page
72 Fiber 72 Fiber
Page
Page
72 Fiber
Page
72 Fiber
72 Fiber
72 Fiber
72 Fiber
Page
Riser OFCR
Rip Cord
Unitized 72 Fiber
72 Fiber
Strength Elements
Buffer Tube
Legend
900um Tight Buffered Fiber
144-Fiber
Corrugated Steel Armor
144-Fiber
144-Fiber
LSZH constructions. Consult1212individual
xx 12-fiber technical data sheets1212
for exact specifications.
Outer Jacket
12-fiber x 12-fiber
x 12-fiber
12 x12
12-fiber
x 12-fiber
144-Fiber
144-Fiber 144-Fiber
144-Fiber
144-Fiber 144-Fiber
12 xx 12-fiber
12 12-fiber 1212
x 12-fiber
Outer Outer Jacket 12 x1212-fiber
Jacket
x 12-fiber x 12-fiber
Rip Cord
Rip Cord OM1 OM2 OM3 OM4 OS2
Buffer Tube
Water Swellable Aramid Yarn Aramid Yarn
Water Swellable Aramid Yarn Aramid Yarn
Outer Jacket 900um Tight Buffered Fiber
Corrugated Steel Armor
Outer Jacket
Corrugated Steel Armor 900um Tight Buffered Fiber
Strength Elements
6 6 Water SwellableSteel
Corrugated Aramid Yarn
Armor
FD1H0065F FD2H0065F FD3H0065F Aramid
900um Yarn
Tight Buffered Fiber
FD4H0065F FDSH0065F
Central Strength Corrugated Steel Armor 900um
Outer Tight Buffered Fiber
Jacket
250um Fiber
Inner Jacket
58 1.800.BELDEN.1 (800.235.3361) www.belden.com
Moisture Blocking Gel
el
Rip Cord
250um Fiber
Outer Jacket
ember
250um Fiber
Inner Jacket
r
Moisture Blocking Gel
Outer Jacket
water migration. Available • Direct burial
Rip Cord
12
12 to 48Fiber
Fiber
Page 49 and 50 Pictures
Specifications
Page51
72 Fiber 72 Fiber
Page
Page
72 Fiber
Page
727272 Fiber
Fiber 72 Fiber
72 Fiber
Fiber 72 Fiber
72 Fiber
Unitized Temperature Range
12-Fiber 2700 600 890 200 Storage -40°C to 75°C
Sub-Units Operating -40°C to 70°C
96 15.2 0.6 180 121
96-Fiber
8 x 12-fiber
96-Fiber
8 x 12-fiber
Min. Bend Radius
96-Fiber
96-Fiber 96-Fiber Installation 20 x OD
8 x 12-fiber 8 96-Fiber
x 12-fiber
8 x 12-fiber
96-Fiber
96-Fiber 896-Fiber
x 12-fiber
96-Fiber Long Term 15 x OD
8 x812-fiber
x 12-fiber
88 xx 12-fiber
12-fiber
Legend
144 19 0.75 274 184
Outer Jacket
144-Fiber 144-Fiber
12 x 12-fiber 12 x 12-fiber Rip Cord
Outer Jacket
No. of 12 x 12-fiber Belden Part Number 250 µm Fiber
No. of Fibers
Fibers
Aramid Yarn Per Bundle OM1 OM2 OM3 OM4 OS2 Inner Jacket
900um Tight Buffered Fiber
2 Outer Jacket
Aramid Yarn
2 FS1H002NF FS2H002NF FS3H002NF FS4H002NF FSSH002NF
900um Tight Buffered Fiber Aramid Strength
4 4 FS1H004NF FS2H004NF FS3H004NF FS4H004NF FSSH004NF
Aramid Yarn
Outer Jacket
900um Tight Buffered Fiber Members
6 Outer Jacket
6 FS1H006NF FS2H006NF FS3H006NF FS4H006NF FSSH006NF Compliance
8 8 FS1H008NG FS2H008NG FS3H008NG FS4H008NG FSSH008NG
• TIA/EIA-568-C.3
12 12 FS1H012NG FS2H012NG FS3H012NG FS4H012NG FSSH012NG
18 12 FS1H018NG FS2H018NG FS3H018NG FS4H018NG FSSH018NG • ICEA S-87-640
24 12 FS1H024NG FS2H024NG FS3H024NG FS4H024NG FSSH024NG • GR-20-CORE
36 12 FS1H036NG FS2H036NG FS3H036NG FS4H036NG FSSH036NG
48 12 FS1H048NG FS2H048NG FS3H048NG FS4H048NG FSSH048NG
72 12 FS1H072NG FS2H072NG FS3H072NG FS4H072NG FSSH072NG
96 12 FS1H096NG FS2H096NG FS3H096NG FS4H096NG FSSH096NG
144 12 FS1H144NG FS2H144NG FS3H144NG FS4H144NG FSSH144NG
216 12 FS1H216NG FS2H216NG FS3H216NG FS4H216NG FSSH216NG
96-Fiber 96-Fiber
96-Fiber
8 x 12-fiber 8 x 12-fiber
8 x 12-fiber
6 Fiber
6 Fiber 6 Fiber
Page 53 Pictures
waterblocked with gel-filled buffer • Drop cable
FSSC012N0, Optical Fiber Central Loose Tube Cable, Outdoor tube. No rods – easy handling. Crush, • Telecommunications and data trunk
Outer Jacket
impact and abrasion resistant. Strength Elements
• Direct burial (armored only)
Buffer Tube
72 Fiber Corrugated Steel Armor Drawings for Single Jacket, Single 900um Tight Buffered Fiber
72 Fiber
Tensile Strength lsb-f
Outer Jacket
72 Fiber
Jacket Specifications Fiber Cable OD Armor Page
Weight
Installation Operation
Name Construction
Count
Jacket Material PE mm in. Kg/km lb/1000 ft. N lbs-f N lbs-f
Outer
Outer Jacket
Jacket
Strength
Strength Elements
Elements Tensile Strength lsb-f
Fiber
Outer Jacket
Cable OD Weight
Name Construction Installation Operation
Buffer
Buffer TubeTube Count
Strength Elements
Corrugated SteelSteel
Corrugated Armor
Armor Outer Jacket
2
4
Single 6
12.2 0.48 140 95 2700 600 890 200
Compliance Subunit 8
12
• TIA/EIA-568-C.3 24
• GR-20-CORE Above specifications provide a general representation for the product family. Improved specifications may exist for Riser, Plenum or
LSZH constructions. Consult individual technical data sheets for exact specifications.
• ICEA S-87-640 Corrugated Steel Armor
Belden Part Number
Rip Cord No. of
Fibers
Numbered Sub Unit OM1 OM2 OM3 OM4 OS2
Central Strength Member Outdoor Armored
144-Fiber 144-Fiber
12 x 12-fiber 12 x 12-fiber
FiberExpress Drop Cables
Tight Buffer — Indoor/Outdoor Riser Rated
Temperature Range
Belden Part Number
Fiber Count
Black White Temperature Range
Outercable
Jacketwith ITU G.657.B3 Glass — Riser Storage -40°C to 75°C
Drop
Operating -40°C to 70°C
1 FDCP001R9 FDCP001R9W
Strength Elements
Drop cable with ITU G.657.B3 Glass — Riser — 450m Reel-In-A-Box Put-Up
Legend
Buffer Tube 1 FDCP001R9NBY FDCP001R9WBY
Outer
Outer Jacket
Jacket
Compliance
• TIA/EIA-568-C.3
• ICEA-S-104-696
• C(ETL)US TYPE OFNR
• CSA OFN FT4
• TPR.9424
Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page
FCSX06LAFS 23 FD1L006RC 55 FD3D012A9 49 FD3L144RG 55 FD4L036RD 55 FDSH0125G 58
FCSX06LDFS 23 FD1L006RF 55 FD3D012F9 49 FD4D002L9 45 FD4L036RG 55 FDSH0245G 58
FCSX06SAFS 23 FD1L012RD 55 FD3D012L9 45 FD4D002P9 45 FD4L048RD 55 FDSH0365G 58
FCSX06SDFS 23 FD1L012RG 55 FD3D012P9 45 FD4D002R9 45 FD4L048RG 55 FDSH0485G 58
FCSX12LAFS 23 FD1L024RD 55 FD3D012R9 45 FD4D006A9 49 FD4L072RD 55 FDSH0725G 58
FCSX12LDFS 23 FD1L024RG 55 FD3D024A9 49 FD4D006F9 49 FD4L072RG 55 FDSH0965G 58
FCZ00BBFS 12 FD1L036RD 55 FD3D024AJ 49 FD4D006L9 45 FD4L096RD 55 FDSH1445G 58
FD1D002L9 45 FD1L036RG 55 FD3D024F9 49 FD4D006P9 45 FD4L096RG 55 FDSL006RC 55
FD1D002P9 45 FD1L048RD 55 FD3D024L9 45 FD4D006R9 45 FD4L144RD 55 FDSL006RF 55
FD1D002R9 45 FD1L048RG 55 FD3D024P9 45 FD4D012A9 49 FD4L144RG 55 FDSL012RD 55
FD1D006A9 49 FD1L072RD 55 FD3D024PJ 45 FD4D012F9 49 FDCP001R9 61 FDSL012RG 55
FD1D006F9 49 FD1L072RG 55 FD3D024R9 45 FD4D012L9 45 FDCP001R9NBY 61 FDSL024RD 55
FD1D006L9 45 FD1L096RD 55 FD3D024RJ 45 FD4D012P9 45 FDCP001R9W 61 FDSL024RG 55
FD1D006P9 45 FD1L096RG 55 FD3D048AK 49 FD4D012R9 45 FDCP001R9WBY 61 FDSL036RD 55
FD1D006R9 45 FD1L144RD 55 FD3D048LK 45 FD4D024A9 49 FDSD002L9 45 FDSL036RG 55
FD1D012A9 49 FD1L144RG 55 FD3D048PK 45 FD4D024AJ 49 FDSD002P9 45 FDSL048RD 55
FD1D012F9 49 FD2H0065F 58 FD3D072AK 49 FD4D024F9 49 FDSD002R9 45 FDSL048RG 55
FD1D012L9 45 FD2H0125G 58 FD3D072LK 45 FD4D024L9 45 FDSD006A9 49 FDSL072RD 55
FD1D012P9 45 FD2H0245G 58 FD3D072PK 45 FD4D024P9 45 FDSD006F9 49 FDSL072RG 55
FD1D012R9 45 FD2H0365G 58 FD3D096AK 49 FD4D024PJ 45 FDSD006L9 45 FDSL096RD 55
FD1D024A9 49 FD2H0485G 58 FD3D096LK 45 FD4D024R9 45 FDSD006P9 45 FDSL096RG 55
FD1D024AJ 49 FD2H0725G 58 FD3D096PK 45 FD4D024RJ 45 FDSD006R9 45 FDSL144RD 55
FD1D024F9 49 FD2H0965G 58 FD3D144AK 49 FD4D048AK 49 FDSD012A9 49 FDSL144RG 55
FD1D024L9 45 FD2H1445G 58 FD3D144LK 45 FD4D048LK 45 FDSD012F9 49 FF1U06SD 15
FD1D024P9 45 FD2L006RC 55 FD3D144PK 45 FD4D048PK 45 FDSD012L9 45 FF1U12LD 15
FD1D024PJ 45 FD2L006RF 55 FD3H0065F 58 FD4D072AK 49 FDSD012P9 45 FF1X03SD 22
FD1D024R9 45 FD2L012RD 55 FD3H0125G 58 FD4D072LK 45 FDSD012R9 45 FF1X06LD 22
FD1D024RJ 45 FD2L012RG 55 FD3H0245G 58 FD4D072PK 45 FDSD024A9 49 FF1X06SD 22
FD1D048AK 49 FD2L024RD 55 FD3H0365G 58 FD4D096AK 49 FDSD024AJ 49 FF1X12LD 22
FD1D048LK 45 FD2L024RG 55 FD3H0485G 58 FD4D096LK 45 FDSD024F9 49 FF1X16LD 22
FD1D048PK 45 FD2L036RD 55 FD3H0725G 58 FD4D096PK 45 FDSD024L9 45 FF3H18LD 15
FD1D072AK 49 FD2L036RG 55 FD3H0965G 58 FD4D144AK 49 FDSD024P9 45 FF3H18MP 15
FD1D072LK 45 FD2L048RD 55 FD3H1445G 58 FD4D144LK 45 FDSD024PJ 45 FF3U06SD 15
FD1D072PK 45 FD2L048RG 55 FD3L006RC 55 FD4D144PK 45 FDSD024R9 45 FF3U12LD 15
FD1D096AK 49 FD2L072RD 55 FD3L006RF 55 FD4H0065F 58 FDSD024RJ 45 FF3U12MP 15
FD1D096LK 45 FD2L072RG 55 FD3L012RD 55 FD4H0125G 58 FDSD048AK 49 FF3X03SD 22
FD1D096PK 45 FD2L096RD 55 FD3L012RG 55 FD4H0245G 58 FDSD048LK 45 FF3X06LD 22
FD1D144AK 49 FD2L096RG 55 FD3L024RD 55 FD4H0365G 58 FDSD048PK 45 FF3X06SD 22
FD1D144LK 45 FD2L144RD 55 FD3L024RG 55 FD4H0485G 58 FDSD072AK 49 FF3X12LD 22
FD1D144PK 45 FD2L144RG 55 FD3L036RD 55 FD4H0725G 58 FDSD072LK 45 FF3X16LD 22
FD1H0065F 58 FD3D002L9 45 FD3L036RG 55 FD4H0965G 58 FDSD072PK 45 FF4H18LD 15
FD1H0125G 58 FD3D002P9 45 FD3L048RD 55 FD4H1445G 58 FDSD096AK 49 FF4H18MP 15
FD1H0245G 58 FD3D002R9 45 FD3L048RG 55 FD4L006RC 55 FDSD096LK 45 FF4U06SD 15
FD1H0365G 58 FD3D006A9 49 FD3L072RD 55 FD4L006RF 55 FDSD096PK 45 FF4U12LD 15
FD1H0485G 58 FD3D006F9 49 FD3L072RG 55 FD4L012RD 55 FDSD144AK 49 FF4U12MP 15
FD1H0725G 58 FD3D006L9 45 FD3L096RD 55 FD4L012RG 55 FDSD144LK 45 FF4X03SD 22
FD1H0965G 58 FD3D006P9 45 FD3L096RG 55 FD4L024RD 55 FDSD144PK 45 FF4X06LD 22
FD1H1445G 58 FD3D006R9 45 FD3L144RD 55 FD4L024RG 55 FDSH0065F 58 FF4X06SD 22
Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page
401 Pennsylvania Parkway, #200 Belden Canada Inc. Insurgentes Sur #1602
Indianapolis, IN 2310 Alfred-Nobel Piso 1 Oficina 102
USA St-Laurent Quebec H4S 2B4 Código Constructor Del.
Phone: (1)-317-818-6300 Canada Benito Juárez , C.P. 03940
Inside Sales: 800-235-3361 Phone: 514-822-2345 Mexico
Fax: (1)-317-818-6382 Fax: 514-822-7979 Phone: +52 55-5523-7733
info@belden.com info@belden.com Fax: +52 55-5528-8077
ventas.mexico@belden.com