SAUDIARAMCO.

NOTES:

1. CONSTRUCTION CONTRACTOR SHALL PROVIDE


GENERAL: SUFFICIENT CONCRETE CURB/BARRIER ON THE
PARKING SHADE LAYOUT TO PROTECT THE
1. ALL DIMENSIONS AND OTHER PURELY STRUCTURAL DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS MUST BE CHECKED AGAINST 3. DESIGN LOAD CRITERIA: STRUCTURE FROM VEHICULAR IMPACT.
ARCHITECTURAL DRAWINGS. SAUDI ARAMCO TO PROVIDE CERTIFIED CORRECT SITE PLAN BEFORE DESIGN OF SHADE STRUCTURE.
a. WIND UPLIFT AND STEEL DEAD LOADS ARE APPLICABLE.
2. REPORT ANY DISCREPANCIES TO SAUDI ARAMCO OR ENGINEER OF RECORD, PRIOR TO PROCEEDING TO THE WORK. b. ALL STRUCTURES ARE NOT DESIGNED FOR SNOW LOADS UNLESS SPECIFIED.

OF
3. DO NOT SCALE THE DRAWINGS UNLESS ORIGINAL SEALED SET. c. THE STRUCTURE DESCRIBED ON THE FOLLOWING DRAWINGS HAS BEEN DESIGNED

CONSENT
4. ALL SHOP DRAWINGS SHALL BE SUBMITTED TO SAUDI ARAMCO FOR APPROVAL PRIOR TO FABRICATION OF ALL ITEMS. DRAWING AND CALCULATED SOLELY FOR THE PURPOSE OF SUN PROTECTION BY USE
SHALL INCLUDE ALL SHOPS AND ERECTION DETAILS. OF FABRIC MEMBRANE ROOF COVER ONLY.

5. STEEL SHAPES AND PLATES SHALL CONFORM TO ASTM STD A-36. ALL SURFACES MUST BE GALVANIZED PRIMED. (ZRC COATING) e. THE SHADE STRUCTURES ARE DESIGNED ONLY FOR THE USE OF POLYETHYLENE
OR POWDER COATED TO COLOR OF CHOICE REQUIRED BY SAUDI ARAMCO. FABRIC THAT MEET MINIMUM REQUIREMENTS.

6. ALL ITEMS SHALL BE INSTALLED AND SET IN THE CORRECT LOCATION AS SHOWN ON THE DRAWINGS (THEY SHALL BE SET LEVEL, f. ALL SHADE STRUCTURE FABRIC ARE DESIGNED FOR QUICK AND SIMPLE REMOVAL

TTEN
PLUMB SQUARE AT THEIR PROPER ELEVATIONS.) TYPE SYSTEM AND IS RECOMMENDED TO BE REMOVED WHEN EXPECTANT OF ANY
WIND FORCE OF OVER THE DESIGNED WIND SPEED IN ORDER TO NOT DAMAGE FABRIC IN EVENT.
7. CONTRACTOR SHALL COORDINATE THE FOUNDATIONS PLAN WITH ARCHITECTURE DRAWINGS FOR OPENING, DROPS, INSERT AND RELATED ITEM.

WRI
g. SHADE STRUCTURES ARE DESIGNED USING THE SAME CONCEPT OF FABRIC ASSEMBLY TO THE STEEL
8. CONTRACTOR SHALL ALSO VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD BEFORE CONCRETE IS PLACED.
FRAME WORK AS DESCRIBED IN THE FOLLOWING:
9. THE CONTRACTOR SHALL VERIFY PRIOR TO CONSTRUCTION THAT THE NEW CONSTRUCTION WILL NOT CONFLICT WITH ANY EXISTING UTILITIES.

THE
i. AT NO TIME DURING OR AFTER ERECTION MAY THE FABRIC BE FASTENED TO ANY OTHER MEMBER
IF CONFLICTS ARISE, THE CONTRACTOR SHALL NOTIFY SAUDI ARAMCO AND SHALL STOP THE WORK.
OF THE EXISTING FRAMEWORK.
10. TYPICAL DETAILS AND NOTES SHALL APPLY UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE. CONSTRUCTION DETAILS NOT FULLY ii. FABRIC ROOF COVER MUST BE INSTALLED AS DESCRIBED IN THE MANUFACTURERS STANDARD

THOUT
SHOWN OR NOTED SHALL BE SIMILAR TO DETAILS SHOWN FOR THE SIMILLAR CONDITIONS. INSTALLATION MANUAL OR AS DRAWING DESCRIBES.

4. APPLICABLE CODE AND STANDARDS:

WI
CONSTRUCTION CODE TYPE:
STANDARD NUMBER TITLE

NG
ASCE 7-05 CONSTRUCTION TYPE: 1 (LOW HAZARD SHELTER)

DRAWI
SAES-H-001 SELECTION REQUIREMENTS FOR INDUSTRIAL COATINGS
SAES-H-003 COATING REQUIREMENTS FOR CONCRETE SURFACES
SAES-H-101 APPROVED PROTECTIVE COATING SYSTEMS
SAES-M-001 STRUCTURAL DESIGN CRITERIA FOR NON-BUILDING STRUCTURES

S
CONCRETE:

THI
SAES-M-100 SAUDI ARAMCO BUILDING CODE
SAES-O-100 GENERAL REQUIREMENTS SAFETY AND SECURITY
STEEL..................... FY=60000 PSI (ACI 318 12.21)
SAES-P-100 BASIC POWER SYSTEM AND DESIGN CRITERIA

FROM
CONCRETE..................... F’C=4000 PSI (@ STD AGE 28 DAYS SAES-P-104 WIRING METHOD AND MATERIALS
ALL CONCRETE FOOTING FOR SHADE STRUCTURE TO BE DESIGNED PER SAES-P-111 GROUNDING SYSTEM
SAES-P-123 LIGHTING

NED
SAES Q-005
ACI 318-05 SAES-Q-001 CRITERIA FOR DESIGN AND CONSTRUCTION OF CONCRETE STRUCTURES

OBTAI
NET ALLOWABLE SOIL PRESSURE 100 KPa SAES-Q-005 CONCRETE FOUNDATION
3 SAES-Q-006 ASPHALT CONCRETE PAVING
DENSITY 24 KN/m
SAES-Q-010 CEMENT BASE, NON-SHRINK GROUT FOR STRUCTURAL & EQUIPMENT GROUTING
USE ASTM OR ACI STANDARD REINFORCING BARS

BE
ANCHOR BOLTS ARE A36 OR A307 AS OTHERWISE SPECIFIED ON DETAIL PER SAES Q-005 & ACI 318-05 APPENDIX B SAES-Q-010 CEMENT BASE, NON-SHRINK GROUT FOR STRUCTURAL & EQUIPMENT GROUTING

WEDGE ANCHOR BOLTS ARE TO A304 OR 318 STAINLESS STEEL OR OTHERWISE SPECIFIED ON DETAIL ACI 318 AMERICAN CONCRETE INSTITUTE; BUILDING CODE PART 1, 2 & 3 REQUIREMENTS FOR REINFORCED CONCRETE

PART,SHALL
ACI 315 DETAILS AND DETAILING OF CONCRETE REINFORCEMENT
ACI 347 RECOMMENDED PRACTICE FOR CONCRETE FORMWORKS
AISC 360-05 SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS
AWS D1.1 AMERICAN WELDING SOCIETY, STRUCTURAL WELDING CODE

FABRICATION IBC 2006 INTERNATIONAL BUILDING CODE


SASO SAUDI ARABIAN STANDARD ORGANIZATION
ANSI AMERICAN NATIONAL STANDARD

N
I
FULL,OR
STRUCTURAL STEEL:
SAUDI ARAMCO MATERIAL SPECIFICATIONS SYSTEM REFERENCE DRAWINGS
1 . ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, AND ERECTED IN ACCORDANCE WITH THE AISC "MANUAL
PARKING STALL LAYOUT AND
OF STEEL CONSTRUCTION" AND THE AISC "SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS. 09-SAMSS-097 READY MIXED PORTLAND CEMENT DD-950107 SHT. 001 REV. 00
WHEEL STOP DETAIL
09-SAMSS-106 EPOXY COATING OF STEEL REINFORCING BARS
CONCRETE SIDEWALK, CURB,

N
STEEL USED FOR FABRICATION IS MANUFACTURED PER:

I
12-SAMSS-007 FABRICATION OF STRUCTURAL AND MISCELLANEOUS STEEL AB-036260 SHT. 001 REV. 05
AND GUTTER DETAILS
12-SAMSS-008 ERECTION OF STRUCTURAL AND MISCELLANEOUS STEEL

ON
ASTM A-500 GRADE A-1008 AND 1010 CARON STEEL PARKING SUNSHADE DA-950182

REPRODUCTI
SECTIONS AND DETAILS DA-950183
GRADE B-1010 THROUGH 1022 CARBON STEEL/ 15 GAUGE & HEAVIER
FOUNDATION PLAN,
DA-950184
GRADE C-1015 THROGH 1022 CARBON STEEL/ 15 GAUGE & HEAVIER
SECTION AND DETAIL

ALL STRUCTURAL STEEL IS COLD ROLLED GALVANIZED PER ASTM A-513 TABLE 9
TECHNICAL SPECIFICATIONS SHADE FABRIC:
2 . STEEL SHALL CONFORM TO THE FOLLOWING GRADES:

SAUDIARAMCO.NO
WF, CHANNELS, ANGLES, PLATES, ETC. ....A36 ALL SHADE FABRIC NETTING CONSTRUCTED FROM HIGH DENSITY POLYETHYLENE RAW MATERIAL WITH ULTRA
VIOLET ADDITIVES, A MONOFILAMENT AND TAPE CONSTRUCTION GIVING FABRIC STABILITY AND IN RACHEL
STRUCTURAL TUBE.............FY=55
KNITTED TO ENSURE MATERIAL WILL NOT UNRAVEL WHEN CUT.
STEEL PIPE.........................FY=50 LIFE EXPECTANCY DUE TO FADING MIN. 5 YEARS CONTINOUS EXPOSURE TO SUN.
THE FABRIC MEMBRANE SHOULD OFFER DURABILITY OF 10 TO 20 YEARS MINIMUM.
CONNECTION BOLTS...........A325
SHADE PERCENTAGE RANGE FROM 45% THROUGH 95 % SHADE FACTOR. SHADE FACTORS VARY WITH COLOR AND FABRIC STYLE
WELDING ELECTRODES........E70XX FABRIC TESTED USING PROCEDURE OUTLINED IN ASTM E-84-91A "STANDARD TEST METHOD FOR SURFACE BURNING CHARACTERS
OF BUILDING MATERIALS",
3 . ALL SHOP AND FIELD WELDING SHALL BE DONE BY CURRENTLY CERTIFIED WELDERS IN ACCORDANCE WITH AWS STRUCTURAL WELDING. SPECIFIED IN NFPA 255, UL No. 723, ANSI 2.5 & UBC 42-1.
FLAME SPREAD INDEX-15 (CLASS-1), SMOKE INDEX 15

OF
4 . UNLESS NOTED OTHERWISE, WELDS SHALL BE BASED ON MINIMUM THICKNESS AS PER AISC SECTION 1.17 ON ALL CONTACT SURFACES.

5 . STRUCTURAL STEEL SHOP DRAWINGS MAY BE REVIEWED PRIOR TO FABRICATION.

PROPERTY
6 . ALL STRUCTURAL STEEL , PLATES, AND BOLTS EXPOSED TO THE ENVIRONMENT ARE TO BE GALVANIZED (ZRC COATED) UNLESS OTHERWISE
SPECIFIED BASED UPON ACCEPTANCE BY SAUDI ARAMCO.

7 . FABRIC COLOR & SHADE STRUCTURE PAINT SCHEME OR POWDER COATED STEEL FRAME IS TO BE DETERMINED BY SAUDI ARAMCO.
WARP WEFT

BREAKING FORCE N/50mm 799 2147


BUILDING ERECTION:

SOLE
BREAKING EXTENSION % 83.5 63.0
THIS SHALL BE ACCOMPLISHED ACCORDING TO THE INSTALLATION INSTRUCTIONS PROVIDED BY MANUFACTURER AND SHALL BE CONSISTENT
WITH GOOD CONSTRUCTION PRACTICES.

THE
TEAR RESISTANCE (WING TEAR) N 172 282
FASTENERS COMPLY WITH AISC STANDARDS, BOLTS & NUTS ARE STAINLESS STEEL.
BURSTING FORCE (STEEL BALL) MEAN N 1861

ARE
PAINT & FINISH:
BURSTING PRESSURE MEAN KPA 3000

N
STEEL..... ALL TO BE POWDER COATED. ALL WELDS TO BE ZRC ZINC COATED

HEREI
PLATES..... ALL TO BE ZRC ZINC COATED RUST CORROSION TREATED COLOURS UVA % UVB % MEAN UPF
POWDER COATED STEEL TO HAVE MIN. 2.5 MIL TO 3MIL UV-INHIVITED WEATHER RESISTANT POWDER COAT
PORCELAIN 95.0 23 78

NED
SCALE:
SANDSTONE 92.8 14 79

CONTAI
DESIGN BASIS: RUST 86.3 7 74
REVISION VALIDATION

THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION


BRONZE 95.8 21 89 00
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

1. THE STRUCTURE DESCRIBED ON THE STRUCTURAL DRAWING HAS BEEN DESIGNED TO COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING:

ON
CLARET 94.0 19 88 714330-1110-001

NFORMATI
a. AMERICAN SOCIETY OF CIVIL ENGINEER ASCE-7-05 OR LATEST EDITION.
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
YELLOW 95.3 21 73 (DESIGN AGENCY) x REQUIRED (SAUDI ARAMCO)
b. SAES -M-001- STRUCTURAL DESIGN CRITERIA FOR NON BUILDING STRUCTURE.
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE

GSE ASE
AQUAMARINE 90.5 12 73
2. TO THE BEST OF ENGINEERS KNOWLEDGE AND BELIEF THE STRUCTURE DEFICTED ON THE STRUCTURAL DRAWINGS 03/24/09 06/07/09

REV.NO. DATE REVISION DESCRIPTION


AND SPECIFICATIONS HAS BEEN DESIGNED IN ACCORDANCE WITH THE FOLLOWING:

I
NAVY BLUE 96.3 27 89
00 11-01-11 ISSUED FOR CONSTRUCTION
a. DESIGN WIND LOADS FOR THE MAIN WIND FORCE RESISTING SYSTEMS, AND FOR THE SELECTION OF

THE
JOB ORDER/EWO NO.
COMPONENTS WERE CALCULATED IN AACORDANCE WIH THE ANSI / ASCE 7-05 AND AISC ASD 9TH EDITION BLACK 95.9 24 97 THIS REVISION IS NOT TO BE USED FOR

FOR ALLOWABLE STRESS DESIGN. 714330 CONSTRUCTION UNTIL CERTIFIED AND DATED

SLATE 96.2 27 94
SAUDI ARABIAN OIL COMPANY

AND
b. MINIMUM BASIC WIND SPEED-155 KPH, 170KPH & 190KPH MINIMUM WHERE SPECIFIED
DRAWING TYPE
BLUE GUM 94.3 18 88
GENERAL NOTES LIB

NG
SILVER 90.9 11 95 PARKING SUNSHADE

DRAWI
LIGHT GREEN 91.8 13 79

LIB. DWG. SAUDI ARABIA


MIDNIGHT GREEN 95.7 23 91

S
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

THI
M88 Q/M DA-950185 001 00
Saudi Aramco 2615 ENG. (05/05)

VECTOR CADD-01