Sunteți pe pagina 1din 1

PROJECT CONSTRUCTION OF BLANG BINTANG REGIONAL LANDFILL

GAMPONG JAWA TRANSFER STATION

FIELD DENSITY TEST


Sand Cone Method
AASHTO T 191/D - 1566

Consultant : RPH
Contractor : PT. WASKITA KARYA Material : Soil Fill
Location : Gampong Jawa
Date Test : September 20, 2011

Notasi STATION : Satuan Rumus 8 Pass 10 Pass 12 Pass

A Wt. of sand + bottle before Gr 7200 7200 7200


B Wt. of sand + bottle after Gr 2845 2998 3021
C Wt. of sand used Gr (A-B) 4355 4202 4179
D Wt. of sand in cone and plate Gr 1470 1470 1470
E Wt. of sand in hole Gr (C-D) 2885 2732 2709
F γ max of sand Gr/cm3 1.496 1.496 1.496
G Volume in hole Cm3 (E/F) 1928.48 1826.20 1810.83
H Wt. wet of aggregate and plastic Gr 2815 2820 2715
I Wt. of plastic Gr 5 5 5
J Wt. wet of aggregate Gr (H-I) 2810 2815 2710
K Wet density of aggregate Gr/cm3 (J/G) 1.457 1.541 1.497
L Dry density of aggregate Gr/cm3 ( K/100 + g )100 1.299 1.393 1.321
M Moisture content optimum % 26.590 26.59 26.59
N Dry density max ( Lab ) Gr/cm3 1.452 1.452 1.452
O Degree of density % (L / N)*100 89.45 95.95 91.00

WATER CONTENT
a Number container
b Wt. wet of aggregate + container Gr 538.1 588.2 522.6
c Wt. dry of aggregate + container Gr 486 537.3 467.9
d Wt. of water Gr (b-c) 52.1 50.9 54.7
e Wt. of container Gr 58.6 59.2 55.6
f Wt. dry of aggregate Gr (c-e) 427.4 478.1 412.3
g Water content % (d/f) 12.19 10.65 13.27

Prepared by Contactor : Approved by Consultant :

( ……………………………. ) ( ……………………………. )