Type 27
2/2-way solenoid valve
NC - Valve normally closed (as standard)
Type 27
NO - Valve normally open (as option)
1/4
TECHNICAL FEATURES
Type 27
DN Kv-value Standard type .032 .012 .702 .322 .242 .272 .352
m³/h
15 3,9 .2701/..01/ 0-10 0-16 0-16 - - - -
20 10,8 .2702/..01/ 0-6 0-10 0-16 - - - -
25 13,0 .2703/..01/ 0-6 0-10 0-16 - - - -
32 30,0 .2704/..01/ - - - 0-10 0-16 0-16 -
40 32,0 .2705/..01/ - - - 0-10 0-16 0-16 -
50 45,0 .2706/..01/ - - - 0-6 0-16 0-16 -
80 97,0 .2708/..01/ - - - - 0-2 0-3 -
100 143,0 .2709/..01/ - - - - - 0-2 -
150 370,0 .2711/..01/ - - - - - 0-2 0-2
The flow rate mentioned in the table applies to the strongest coil.
2/4
DIMENSIONS
Type 27
Coil .032 /.012 / .148* .702 /.808* .322 /.328*
Type .2701 .2702 .2703 .2701 .2702 .2703 .2704 .2705 .2706
DN 15 20 25 15 20 25 32 40 50
C 61 61 61 67 67 67 77 77 77
D 95 105 115 95 105 115 140 150 165
K 94 (86) 100 (96) 100 (96) 114 (106) 127 (122) 127 (122) 184 (172) 184 (172) 192 (179)
L 130 150 160 130 150 160 180 200 230
t 16 18 18 16 18 18 18 18 20
kg 2,8 3,9 4,5 3,1 4,2 4,8 8,8 9,3 12,1
*Differing dimension “C“ for ATEX-coils
3/4
INFORMATION
It is imperative to observe the installation and safety instructions in our operating and service manuals.
For information on our GSR ordering code, please refer to our catalogs. If you have any questions, we will be
glad to assist you.
Type 27
Required ordering information: valve type, function NC/NO, pressure range, connection, nominal width,
medium, flow rate, medium and ambient temperatures, connection voltage.
Detailed production-specific drawings and other technical information will be made available when an
order is placed
PLEASE NOTE
Each individual application decides which valve type is required, the main factor being the resistance of the materials to the
operating medium. The correct selection of materials requires knowledge of the concentration, temperature and degree of
contamination of the medium. Other criteria include the operating pressure and max. volumetric flow, since , in addition to high
temperatures , high pressures and high flow rates must also be taken into account when selecting the materials.
All materials used for our valves, be it housing, seals or magnets, will be carefully selected in view of the different
application areas. Any information given is non-binding and serves for orientation only. No claims under warranty can be
derived therefrom.
GSR solenoid coils are by default designed for a maximum ambient temperature of +35 °C. This specification applies for the
maximum allowable operating pressure specified in the data sheet of the corresponding valve, 100% duty cycle and a medium
temperature of +80 °C.
A higher ambient temperature is possible, when lower values are applied for the other influencing parameters. When the max.
operation pressure and max. ambient temperature of +50 °C is given the medium temperature is not allowed to be higher than max.
+50 °C. In addition to that, deviations from the default design temperature range are possible, e.g. when temperature coils or other
constructive measures are used. Please contact the GSR headquarters to discuss the specific application.
More precise specifications and technical data with regard to the operating conditions can be found in the data sheets of the
solenoid coils and the solenoid valve regarded. Please observe that the surface temperature of a permanently loaded coil can
amount up to +120 °C, solely by the self-heating of the coil. The power consumption of our default solenoid valves was calculated
to DIN VDE 05820 for a coil temperature of +20 °C.
The GSR logo is a registered trademark of GSR Ventiltechnik GmbH & Co. KG.
Note: All texts and images are the property of GSR Ventiltechnik GmbH & Co. KG and must not be replicated
or modified, not even in part, without written approval.
Original products may differ from the product images shown, due to different materials and the like.
Subject to error and changes.
4/4