Technical Data Sheet

Type 27
2/2-way solenoid valve
NC - Valve normally closed (as standard)

Type 27
NO - Valve normally open (as option)

Force-pilot operated diaphragm design valve. No differential pressure is necessary for


operation.
In standard (NC) the valve closes with spring power.

 Solenoid valve for gaseous and liquid media

TECHNICAL SPECIFICATIONS VALVE FEATURES


Type of control Force-pilot operated, no pressure  No pressure difference required
difference necessary
 High life time
Design Diaphragm design  Simple compact valve design
Connection Flanged  Low weight
acc. to EN 1092-1 Form B1/B2  High-quality materials
Installation With actuator upright  Reliable and sturdy sealing elements
 Long-term availability of spare parts
Pressure 0 - 16 bar (see table on page 2)
Medium Clean, neutral, gaseous and liquid
media
Viscosity 22 mm²/s
FUNCTION
Temperature range Medium: -10 °C up to +80 °C NC – non energized closed NO – non-energized open
Ambient: -10 °C up to +50 °C
In consideration of the restrictions described on page 4

Body material Cast iron EN-GJL-250 (DN20-150)


Cast steel GP240 GH (DN15-100)
Speroidal EN-GJS-400-18-LT (DN150)
Stainless steel 1.4581 (DN15-50)
Metallic inner parts Brass and Staineless steel
CERTIFICATES
Sealing NBR, FKM, EPDM
Supply voltage AC~ 24V, 110V, 230V
DC= 12V, 24V
Other supply voltages on request

Voltage tolerance -10% / +10%


Power .032 =11 Watt .148 =10 Watt
consumption .012 = 18,5 Watt ORDERING SYSTEM
.702 = 25 Watt .808 = 24 Watt
.322 = 30 Watt .328 = 24 Watt
.242 = 46 Watt .248 = 30 Watt
.272 = 100 Watt .278 = 47 Watt
Protection class IP65 acc. to DIN 60529
Duty factor 100% ED-VDE 0580
Connection type Plug, Terminal box
Ex-proof acc. to 2014/34/EG(ATEX)
Further Ex-proof on request

1/4
TECHNICAL FEATURES

max. pressure for coils

Type 27
DN Kv-value Standard type .032 .012 .702 .322 .242 .272 .352
m³/h
15 3,9 .2701/..01/ 0-10 0-16 0-16 - - - -
20 10,8 .2702/..01/ 0-6 0-10 0-16 - - - -
25 13,0 .2703/..01/ 0-6 0-10 0-16 - - - -
32 30,0 .2704/..01/ - - - 0-10 0-16 0-16 -
40 32,0 .2705/..01/ - - - 0-10 0-16 0-16 -
50 45,0 .2706/..01/ - - - 0-6 0-16 0-16 -
80 97,0 .2708/..01/ - - - - 0-2 0-3 -
100 143,0 .2709/..01/ - - - - - 0-2 -
150 370,0 .2711/..01/ - - - - - 0-2 0-2
The flow rate mentioned in the table applies to the strongest coil.

max. pressure for coils ATEX


DN Kv-value Standard type .148 .808 .328 .248 .278 .358
m³/h
15 3,9 .2701/..01/ 0-8 0-16 - - - -
20 10,8 .2702/..01/ 0-5 0-16 - - - -
25 13,0 .2703/..01/ 0-5 0-16 - - - -
32 30,0 .2704/..01/ - - 0-3 0-10 0-16 -
40 32,0 .2705/..01/ - - 0-3 0-10 0-16 -
50 45,0 .2706/..01/ - - 0-3 0-6 0-16 -
80 97,0 .2708/..01/ - - - - 0-2 -
100 143,0 .2709/..01/ - - - - - 0-2
150 370,0 .2711/..01/ - - - - - 0-2
The flow rate mentioned in the table applies to the strongest coil.

2/4
DIMENSIONS

Type 27
Coil .032 /.012 / .148* .702 /.808* .322 /.328*
Type .2701 .2702 .2703 .2701 .2702 .2703 .2704 .2705 .2706
DN 15 20 25 15 20 25 32 40 50
C 61 61 61 67 67 67 77 77 77
D 95 105 115 95 105 115 140 150 165
K 94 (86) 100 (96) 100 (96) 114 (106) 127 (122) 127 (122) 184 (172) 184 (172) 192 (179)
L 130 150 160 130 150 160 180 200 230
t 16 18 18 16 18 18 18 18 20
kg 2,8 3,9 4,5 3,1 4,2 4,8 8,8 9,3 12,1
*Differing dimension “C“ for ATEX-coils

Coil .242 / .248 .272 / .278 .352(8)


Type .2704 .2705 .2706 .2708 .2704 .2705 .2706 .2709 .2711 .2711
DN 32 40 50 80 32 40 50 100 150 150
C 93 93 93 93 107 107 107 107 107 127
D 140 150 165 200 140 150 165 220 285 285
K 209 209 218 255 254 254 264 305 410 450
(198) (198) (205) (242) (242) (251)
L 180 200 230 310 180 200 230 350 480 480
t 18 18 20 21 18 18 20 24 28 28
kg 9,7 10,2 13,0 29,0 13,7 14,3 17,3 45,5 86,0 97,0
The values in brackets refer to the stainless steel version.

3/4
INFORMATION
 It is imperative to observe the installation and safety instructions in our operating and service manuals.
 For information on our GSR ordering code, please refer to our catalogs. If you have any questions, we will be
glad to assist you.

Type 27
 Required ordering information: valve type, function NC/NO, pressure range, connection, nominal width,
medium, flow rate, medium and ambient temperatures, connection voltage.
 Detailed production-specific drawings and other technical information will be made available when an
order is placed

PLEASE NOTE
Each individual application decides which valve type is required, the main factor being the resistance of the materials to the
operating medium. The correct selection of materials requires knowledge of the concentration, temperature and degree of
contamination of the medium. Other criteria include the operating pressure and max. volumetric flow, since , in addition to high
temperatures , high pressures and high flow rates must also be taken into account when selecting the materials.
All materials used for our valves, be it housing, seals or magnets, will be carefully selected in view of the different
application areas. Any information given is non-binding and serves for orientation only. No claims under warranty can be
derived therefrom.

Heating and power of solenoid coils


The GSR default solenoid valves are designed for continuous operation (100% ED = power-on time) under normal operating
conditions. The pulling force of a solenoid coil is basically influenced by three elements:

 The self-heating of the magnetic coil


 The medium temperature
 The ambient temperature

GSR solenoid coils are by default designed for a maximum ambient temperature of +35 °C. This specification applies for the
maximum allowable operating pressure specified in the data sheet of the corresponding valve, 100% duty cycle and a medium
temperature of +80 °C.
A higher ambient temperature is possible, when lower values are applied for the other influencing parameters. When the max.
operation pressure and max. ambient temperature of +50 °C is given the medium temperature is not allowed to be higher than max.
+50 °C. In addition to that, deviations from the default design temperature range are possible, e.g. when temperature coils or other
constructive measures are used. Please contact the GSR headquarters to discuss the specific application.
More precise specifications and technical data with regard to the operating conditions can be found in the data sheets of the
solenoid coils and the solenoid valve regarded. Please observe that the surface temperature of a permanently loaded coil can
amount up to +120 °C, solely by the self-heating of the coil. The power consumption of our default solenoid valves was calculated
to DIN VDE 05820 for a coil temperature of +20 °C.

 The GSR logo is a registered trademark of GSR Ventiltechnik GmbH & Co. KG.
 Note: All texts and images are the property of GSR Ventiltechnik GmbH & Co. KG and must not be replicated
or modified, not even in part, without written approval.
 Original products may differ from the product images shown, due to different materials and the like.
 Subject to error and changes.

Stand: 07.17, MK-MG, Version 1.

4/4