Documente Academic
Documente Profesional
Documente Cultură
ARCHITECTURAL
ELECTRICAL
1 P E R S P E C T I V E
A 1 N T S
THE SITE
STRUCTURAL
MECHANICAL
SANITARY
NOTES:
ELECTRICAL
N
4 - BEDROOM RESIDENCE
PERSPECTIVE
SEPT. 22, 2018
AR - 00
LOT 55, BLK 15, FILHEIGHTS SUBD., QUEZON CITY VICINITY MAP
SITE DEV'T PLAN
- OVO
PETER C. BUGAY, uap
MR & MRS OSCAR V. OROSCO SEPT. 24, 2018
A B C D E F G H I A B C D E F G H I
12 12
932
1587
1507
500
11 11
2000
1425
10 10
9 9
3000
3075
4995
8 8
7 7
2550
2400
6 6
1489
16000
5 5
1725
1650
4 4
800
3 3
3800
3000
2 2
868 1200
2068
1 1
1 2
SCALE SCALE
4 - BEDROOM RESIDENCE
GROUND FLOOR PLAN
SEPT. 22, 2018
AR - 01
LOT 55, BLK 15, FILHEIGHTS SUBD., QUEZON CITY SECOND FLOOR PLAN
- OVO
PETER C. BUGAY, uap
MR & MRS OSCAR V. OROSCO SEPT. 24, 2018
1800
1800
1800
SEE TRUSS DETAILS
3300
3300
3300
8750
8750
8750
3500
3500
3500
150
2 4 6
SCALE SCALE SCALE
1800
1800
1800
SEE TRUSS DETAILS
3300
3300
3300
8750
8750
8750
3500
3500
3500
150
1 3 5
SCALE SCALE SCALE
4 - BEDROOM RESIDENCE
ELEVATIONS
SEPT. 22, 2018
AR - 02
LOT 55, BLK 15, FILHEIGHTS SUBD., QUEZON CITY SECTIONS
- OVO
PETER C. BUGAY, uap
MR & MRS OSCAR V. OROSCO SEPT. 24, 2018
1
2
8
4
N
3
1 2
SCALE SCALE
4 - BEDROOM RESIDENCE
LOT PLAN
SEPT. 22, 2018
AR - 03
LOT 55, BLK 15, FILHEIGHTS SUBD., QUEZON CITY ROOF LAYOUT
- OVO
PETER C. BUGAY, uap
MR & MRS OSCAR V. OROSCO SEPT. 24, 2018
1200 800 1200
2400
600 600 600 600 600
500
2
SCALE
500
900 800 1500 1250 2800
1
SCALE
4 - BEDROOM RESIDENCE
DOORS SCHEDULE
SEPT. 22, 2018
AR - 04
LOT 55, BLK 15, FILHEIGHTS SUBD., QUEZON CITY WINDOW SCHEDULE
- OVO
PETER C. BUGAY, uap
MR & MRS OSCAR V. OROSCO SEPT. 24, 2018
METAL
2ND FLOOR LINE HANDRAIL
17 16 15 14 13 12 11
CONCRETE WALL
LANDING LANDING
10
1 2 3 4 5 6 7 8 9 TOP RAIL
CONCRETE BEAM
BALUSTER
BOTTOM RAIL
CONCRETE STAIRS
16
15
2
14
LANDING N T S
13
12
11
10
2
CEILING
1 LIGHT FIXTURES
FIN. FLOOR LINE
BLOCKING
GYPSUM BOARD
1 PLYWOOD
N T S
3
N T S
4 - BEDROOM RESIDENCE
STAIRS DETAILS
SEPT. 22, 2018
AR - 05
LOT 55, BLK 15, FILHEIGHTS SUBD., QUEZON CITY CEILING COVE DETAILS
HANDRAIL DETAILS
- OVO
PETER C. BUGAY, uap
MR & MRS OSCAR V. OROSCO SEPT. 24, 2018
A B C D E F G H I A B C D E F G H I
12 12
932
1507
11 11
2000
1425
10 10
9 9
3000
3075
8 8
7 7
2550
2400
6 6
16000
5 5
1725
1650
4 4
800
3 3
3800
3000
1 2
SCALE
SCALE
2 2
868 1200
2068
1 1
- OVO
PETER C. BUGAY, uap
MR & MRS OSCAR V. OROSCO SEPT. 24, 2018
A B C D E F G H I
A B C D E F G H I
12 12
932
1507
11
2000
11
1425
10 10
9
9
3000
3075
8
8
7 7
2550
2400
6
16000
5
5
1650
1725
4
4
800
3 3
3800
3000
2 2
868 1200
2068
1 1
1
SCALE
9
SCALE
4 - BEDROOM RESIDENCE
ROOF FRAMING PLAN
SEPT. 22, 2018
S - 02
LOT 55, BLK 15, FILHEIGHTS SUBD., QUEZON CITY
- OVO
PETER C. BUGAY, uap
MR & MRS OSCAR V. OROSCO SEPT. 24, 2018
1200
1200
1200
400 300
400 400
1@0.05M, 2@0.10M, 3@0.15M 300
1@0.05M, 2@0.10M, 3@0.15M
NGL & REST @0.20M. O. C & REST @0.20M. O. C 1@0.05M, 2@0.10M, 3@0.15M
NGL
150
400
150
SECTION
400
600
200
GRAVEL BED
5 6
4 SCALE SCALE
N T S
4 - BEDROOM RESIDENCE
COLUMN,FOOTING DETAILS
FTB DETAIL SEPT. 22, 2018
S - 03
LOT 55, BLK 15, FILHEIGHTS SUBD., QUEZON CITY
FOOTING DETAIL
- OVO
PETER C. BUGAY, uap
MR & MRS OSCAR V. OROSCO SEPT. 24, 2018
1 - 2" x 2" x 1/4"
ANGLE BAR FOR TOP & BOT. CHORD 1 - 1 1/2" x 1 1/2" x 1/4"
ANGLE BAR FOR WEB MEMBER
1 - 2" x 2" x 1/4" 2"x4" C- PURLINS SPACED @ 0.70 M.O.C.
1 - 1 1/2" x 1 1/2" x 1/4" ANGLE BAR FOR TOP & BOT. CHORD WITH STEEL CLEAT
1 - 1 1/2" x 1 1/2" x 1/4" ANGLE BAR FOR WEB MEMBER 1 - 1 1/2" x 1 1/2" x 1/4"
1 - 2" x 2" x 1/4" ANGLE BAR FOR WEB MEMBER 1 - 2" x 2" x 1/4" ANGLE BAR FOR WEB MEMBER
ANGLE BAR FOR TOP & BOT. CHORD ANGLE BAR FOR TOP & BOT. CHORD 1 - 2" x 2" x 1/4" 1 - 1 1/2" x 1 1/2" x 1/4"
ANGLE BAR FOR TOP & BOT. CHORD ANGLE BAR FOR WEB MEMBER
2"x4" C- PURLINS SPACED @ 0.70 M.O.C. 2"x4" C- PURLINS SPACED @ 0.70 M.O.C. LONG SPAN RIB-TYPE RFG.
WITH STEEL CLEAT WITH STEEL CLEAT 2"x4" C- PURLINS SPACED @ 0.70 M.O.C.
2"x4" C- PURLINS SPACED @ 0.70 M.O.C. WITH STEEL CLEAT
WITH STEEL CLEAT
LONG SPAN RIB-TYPE RFG.
LONG SPAN RIB-TYPE RFG. LONG SPAN RIB-TYPE RFG.
LONG SPAN RIB-TYPE RFG.
ROOF BEAM
ROOF BEAM
ROOF BEAM ROOF BEAM
3500 3500 2100 1105
788 700 700 700 700 788 1138 700 700 1138 700 700 700 700 795
700 700 927
3675 2327 3595 10205
4375
3 6 9 12 15
SCALE SCALE SCALE SCALE SCALE
ROOF BEAM ROOF BEAM ROOF BEAM 700 700 700 700 1425 559
ROOF BEAM
14
2 5 8 11 SCALE
SCALE SCALE
SCALE SCALE
ROOF BEAM ROOF BEAM ROOF BEAM ROOF BEAM 2800 5651039
2800 3401 4404
1038 2800 2800 1037 2800 997 2100 632
1 4 7 10 13
SCALE SCALE SCALE SCALE SCALE
4 - BEDROOM RESIDENCE
SEPT. 22, 2018
S - 04
LOT 55, BLK 15, FILHEIGHTS SUBD., QUEZON CITY TRUSS DETAILS
- OVO
PETER C. BUGAY, uap
MR & MRS OSCAR V. OROSCO SEPT. 24, 2018
LEGEND AND SYMBOLS
M
1350 1150 2000 1926 2074 1575 2027 2898 1350 1150 2000 1926 2074 1575 2027 2898
932
932
Sy SI
u v y
Sv
o
1 S2
o
2000
2000
S2tu
x
15 10
S3
t
o
m
8
w S3W
S2ro
n n n S2mn
11
3000
3000
q r k k EF
p
S3pqs
3 l 7 GENERAL NOTES
r
S3wz
k
w 6
S2kl S2wx
1. ALL ELECTRICAL WORKS SHALL BE DONE IN ACCORDANCE WITH THE
2550
2550
UP UP
OPEN OPEN
ABOVE ABOVE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE,
x
j i i THE LAWS AND ORDINANCES OF THE LOCAL CODE ENFORCING AUTHORITIES
h
S3hij
AND THE REQUIREMENTS OF THE LOCAL POWER COMPANY.
2 2. THE CONTRACTOR SHALL SECURE ALL PERMITS AND PAY ALL FEES
1650
1650
f e e
REQUIRED FOR THE WORK AND SHALL FURNISH THE OWNER THROUGH
S2ef
d g THE ENGINEERS. FINAL CERTIFICATES OF ELECTRICAL INSPECTION AND
S2ad APPROVAL FROM PROPER GOVERNMENT AUTHORITIES FOR COMPLETE WORK.
800
800
S2bc
3wS3a'b'c'
b
b
g 3. ALL MATERIALS TO BE USED SHALL BE NEW AND INSTALLED IN APPLICATIONS
FOR WHICH THEY ARE INTENDED.
14
3000
3000
4. LIGHTING AND POWER BRANCH CIRCUIT WITHOUT DESIGNATION SHALL
c
GARDEN GARDEN
BE 3-WIRE 3.5 sq.mm TW + GROUND WIRE IN 15mmØ PVC.
2068
a a
6. BOXES SHALL BE MADE OF CODE GAGE #16 STEEL SHEET WITH ZINC CHROMATE
PROTECTION 0.30M RESPECTIVELY, UNLESS OTHERWISE INDICATED
IN ARCHITECTURAL PLANS.
1 LIGHTING LAYOUT 3 POWER LAYOUT 9. VERIFY ARCHITECTURAL DRAWINGS FOR LIGHTING FIXTRURES AND WIRING
E 1 SCALE 1:100 DEVICES' EXACT LOCATION AND MOUNTING HEIGHTS.
E 1 SCALE 1:100
q' NOTES
r' s' s'
S2r's' p'
1. SEE LOAD SCHEDULE AND COMPUTATIONS FOR DETAILS
o' ON EQUIPMENT RATINGS, LOADINGS, BREAKER AND FEEDER SIZES.
S3m'n'o' S2p'q' c' 3. THE ELECTRICAL CONTRACTOR SHALL BE HELD LIABLE IN OBTAINING
b'
THE ACTUAL SITE CONDITION, MEASUREMENTS, AND CLEARANCES.
COORDINATE WITH OTHER TRADES AT SITE TO AVERT CONFLICT
d'
3wz
DN
DURING ACTUAL IMPLEMENTATION.
S3wz
DN
a' b' c'
9
S2d'e'
k'
3wS3a'b'c' SCOPE OF DOCUMENT
l' m'
b'
l' S3k'l'm'
e'
4 THIS DRAWING INDICATES THE GENERAL SCOPE OF THE PROJECT IN
S3h'i'j'
b'
i' c' TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE
h' h'
BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS, AND THE TYPE OF
j'
STRUCTURAL, MECHANICAL, SANITARY, FIRE PROTECTION AND
13 ELECTRICAL SYSTEMS. AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT
GARDEN
GARDEN
NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL
h' h'
PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE
S2f'g' 5 SECOND FLOOR SECOND FLOOR
CONTRACT DOCUMENT. ON THE BASIS OF THE GENERAL SCOPE INDICATED
g' 2 LIGHTING LAYOUT 4 POWER LAYOUT
f'
E 1 SCALE 1:100
OR DESCRIBED, THE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED
E 1 SCALE 1:100
FOR THE PROPER EXECUTION OF AND COMPLETION OF THE WORK.
DECISIONS OF THE ARCHITECT AS TO THE ITEMS INCLUDED WITHIN THE
SCOPE OF THIS DOCUMENT SHALL BE FINAL AND BINDING ON THE
CONTRACTOR AND THE OWNER
DESIGNED BY ARCHITECT REG. NO. 24789 ENGINEER REG. NO. PEE 4292 PROJECT SHEET CONTENTS REVISION DATE SHEET NO.
PTR NO. 4136525 PTR NO. 4136686 4 - BEDROOM RESIDENCE AS SHOWN DRAWN BY
1 LIGHTING LOAD 5 230 500 2.17 15 AT 2 - 3.50 mm² THHN Cu. 20 mmØ TO SERVICE ENTRANCE
2 LIGHTING LOAD 17 230 1700 7.39 15 AT 2 - 3.50 mm² THHN Cu. 20 mmØ
3 LIGHTING LOAD 18 230 1800 7.83 15 AT 2 - 3.50 mm² THHN Cu. 20 mmØ
4 LIGHTING LOAD 17 230 1700 7.39 15 AT 2 - 3.50 mm² THHN Cu. 20 mmØ
5 LIGHTING LOAD 14 230 1400 6.09 15 AT 2 - 3.50 mm² THHN Cu. 20 mmØ
20mmØ X 3M
COMPUTATION: USED: 125AT, 2P, 230V, MCCB GROUND ROD
I MCB = 152.78 x 80% (D.F.)
WIRE: 2 - 38.00 MM ² THHN Cu &
= 122.22 A 1 - 14.00 MM ² THHN Cu (G) @ 50MMØ CONDUIT
ONE LINE DIAGRAM PANEL BOARD RISER DIAGRAM
METALLIC FLEXIBLE
OCTAGONAL BOX CONDUIT
CONDUIT LOCK-NUTS TELEPHONE & DATA
AND BUSHING SERVICE ENTRANCE
COLOR CODED WIRES CABLE TV
WIRE NUT AND CABLES SERVICE ENTRANCE
(TYPICAL)
CONDUIT ON BOX INSTALLATION DETAIL CONDUIT BOX CONNECTION DETAIL CABLE TV SINGLE LINE DIAGRAM TELEPHONE & DATA SINGLE LINE DIAGRAM
DESIGNED BY ARCHITECT REG. NO. 24789 ENGINEER REG. NO. PEE 4292 PROJECT SHEET CONTENTS REVISION DATE SHEET NO.
PTR NO. 4136525 PTR NO. 4136686 4 - BEDROOM RESIDENCE AS SHOWN DRAWN BY
CO CO
PLUMBING LEGEND & SYMBOLS
15mmØ
932
932
15mmØ
WC
20mmØ 20mmØ 20mmØ LAV 15mmØ 100mmØ 100mmØ 100mmØ TO CATCH BASIN 100mmØ 50mmØ 100mmØ
WC LAV WC
100mmØ 75mmØ TO CB 75mmØ 50mmØ
15mmØ
U
20mmØ
F 15mmØ 50mmØ FD U
15mmØ KSF
KS
100mmØ
F 15mmØ
2000
2000
100mmØ
SEWER LINE
20mmØ
GOING UP
KSF CO
HB
15mmØ
FAU
WC
20mmØ
3000
3000
SEPTIC
TANK
20mmØ
GV
M
100mmØ
HB
15mmØ CV
SD
20mmØ
CV
2550
2550
UP UP
HB
150mmØ
OPEN OPEN CO
WATER LINE ABOVE 100mmØ
ABOVE
LAV
M
WC
100mmØ
GOING UP
SHO WC LAV TO CB SD100mmØLAV
GV
15mmØ 15mmØ
20mmØ
50mmØ 50mmØ CB
100mmØ
20mmØ
15mmØ15mmØ
SD 50mmØ SH
1650
1650
SHO WC LAV
20mmØ
800
CO
LC
20mmØ
3000
3000
GARDEN GARDEN
HB
15mmØ
20mmØ
HB 20mmØ
15mmØ
2068
2068
4"Ø INLET PIPE
GROUND FLOOR GROUND FLOOR
1 WATER DISTRIBUTION LAYOUT 3 SANITARY LAYOUT 4"Ø OUTLET
P 1 SCALE 1:100
P 1 SCALE 1:100 PIPE
VSTR
CO
LAV CO
20mmØ
LAV
SHO 15mmØ SEWER LINE SD 50mmØ
15mmØ 50mmØ
GOING DOWN
WC
WC 100mmØ
15mmØ
CO
DESIGNED BY ARCHITECT REG. NO. 24789 ENGINEER REG. NO. 6315 PROJECT SHEET CONTENTS REVISION DATE SHEET NO.
PTR NO. 4136525 PTR NO. 2602743 4 - BEDROOM RESIDENCE AS SHOWN DRAWN BY
100mmØ 100mmØ CB
THE RULES AND REGULATIONS OF THE MUNICIPALITY.
100mmØ
CB CB CB
100mmØ
DS
OPEN 2. COORDINATE THE DRAWINGS WITH OTHER RELATED DRAWINGS WITH OTHER RELATED
AREA DS
2000
DS DS
100mmØ
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH AND
INVERT ELEVATION OF ALL EXISTING PIPES AND STRUCTURES.
DS
DS
ALL VENT STACKS PASSING THRU ROOF SHALL BE PROVIDED WITH METAL FLASHING
CB
DS AND ANCHORAGE.
100mmØ
2550
100mmØ
CB DS 6. ALL HORIZONTAL STORM DRAINAGE PIPES SHALL MAINTAIN MINIMUM SLOPE OF 1%, UNLESS
DS CB
CB 100mmØ OTHERWISE INDICATED ON PLANS.
CB
DS 7. ALL GALVANIZED IRON (GI) PIPES AND FITTINGS BURIED UNDERGROUND SHALL BE RED
DS
LEAD COATED, COALTAR OR ASPHALT COATED WRAPPED WITH BURLAP.
1650
DS M.O.C. BOTHWAYS
PLAN
150mmØ
100mmØ
CB SPACED @ 250 8. ALL GATE VALVES, CHECK VALVES AND DRAIN VALVES SHALL BE PROVIDED AS INDICATED.
12mm.Ø REBARS
800
9. REQUIRED FITTINGS NOT SHOWN ON PLAN SHALL BE PROVIDED. ALL DIMENSIONS ARE IN
T O S T R E E T C A N A L MILLIMETERS UNLESS OTHERWISE INDICATED.
100mmØ
CB CB AND/OR ENGINEER.
100mmØ
100 MMØ
12. ALL PIPE SIZES ( *mmØ ) INDICATED ON THE PLANS SHALL BE INSIDE DIAMETER.
OUTLET PIPE
AIR SPACE 13. THE DRAWINGS SHOW THE GENERAL ARRANGEMENTS OF ALL PIPINGS HOWEVER WHERE
LOCAL AND/OR ACTUAL CONDITIONS AT THE JOBSITE NECESSITATE A DEVIATION OF
INLET WATER LEVEL OUTLET ARRANGEMENT. THE CONTRACTOR SHALL PREPARE AND SUBMIT THE NEW ARRANGEMENTS
14. ALL SLEEVES PENETRATING HEATED TO NON-HEATED AREAS SHALL BE PROPERLY
INSULATED AND SEALED TO PREVENT HEAT LOSS AND SEEPAGE.
1 STORM DRAINAGE LAYOUT
P 2 SCALE 1:100 LEACHING LEACHING 15. SIZE OF SUPPLY TO FIXTURES SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTION.
DIGESTIVE CHAMBER CHAMBER
16. ALL WATER LINES SHALL BE HYDRO-STATIC TESTED AT 100 PSI PRIOR TO TAPPING.
CHAMBER
17. WATERPROOFED ALL WET AREAS WITH HYGARD THOROSEAL OR APPROVED EQUAL AND
SHALL BE FLOOD TESTED FOR 24 HOURS (VERIFY ARCHITECTURAL PLANS).
24. THE CONTRACTOR SHALL SUBMIT TO THE ARCHITECT TWO SETS OF ACTUAL AS BUILT
PLAN UPON EXECUTION OF SANITARY / PLUMBING WORKS.
25. SMALL SCALE DRAWINGS DO NOT POSSIBLY INDICATE ALL OFFSETS, FITTINGS AND OTHER
PARTS OF THE SYSTEM REQUIRED. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE
STRUCTURAL AND FINISHING REQUIREMENTS AFFECTING HIS WORK AND SHALL ARRANGE
SUCH WORK ACCORDINGLY, FURNISHING SUCH FITTINGS, TRAPS, VALVES AND
ACCESSORIES MAYBE REQUIRED TO MEET SUCH CONDITIONS.
DESIGNED BY ARCHITECT REG. NO. 24789 ENGINEER REG. NO. 6315 PROJECT SHEET CONTENTS REVISION DATE SHEET NO.
PTR NO. 4136525 PTR NO. 2602743 4 - BEDROOM RESIDENCE AS SHOWN DRAWN BY