Sunteți pe pagina 1din 86

General Catalogue - QATAR

High Ambient - 50 Hz
Contents
Introduction 03
Index
Residential Products 08

Light Commercial Products 26

VRF Business Products 38

Controls 78

02
Toshiba solutions
At Toshiba, we believe that “Evolution is leading the path to a
better future”. Through the decades, we have been constantly
creating innovative and high-quality electrical appliances to
increase our consumers’ satisfaction.

03
Toshiba Group
Toshiba’s origins go back to 1875 and two great inventors.
Hisashige Tanaka, the Thomas Edison of Asia, was renowned for his inventiveness. The sign that welcomed visitors to
Tanaka Engineering Works “Improving life with things people need,” expressed his deep commitment to prove people’s
quality of life.
Ichisuke Fujioka was Japan’s father of electronics. He manufactured the country’s first incandescent lamps and
pioneered the development of Japan’s electronics industry.
Today, more than 140 years after, Toshiba Group provides a wide range of products and services that feature the best in
innovative technologies and the finest quality.
By continually developing innovative technologies, we strive to create products and services that enhance human life,
and which lead to a thriving healthy society.

A wide innovative range


Digital products: high value-added mobile phones; advanced audio and visual products; Personal Computers and
business communication systems.
Electronic devices and components: advanced semiconductors and display technologies.
Social infrastructure systems: critical components that support power generating, broadcast, transportation, financial
and distribution equipment and systems.
Consumer appliances: from refrigerators, and residencial and commercial air conditioning systems, to automotive
electronics and network services.

Today Toshiba
Toshiba offers a solution for all applications: residential, light commercial and larger commercial buildings.
Residential indoor units are designed to blend perfectly with all interiors and most efficient high-wall units incorporate
advanced filtration systems to deliver optimum indoor air quality.
For small commercial premises, products are designed to deliver optimum performance combined with energy efficiency.
Light commercial systems offer a wide range of indoor units for maximum flexibility.
For larger applications, VRF systems combine flexibility, energy efficiency and respect for the environmental. These
reliable systems offer a wide choice of stylish indoor units.

Technology & Environment


Toshiba constantly works to ensure that our air conditioners help protect the environment while delivering reassurance
and reliability to users around the world.
Toshiba has earned international praise for building energy-saving products, and for its environmentaloriented production
facilities. The company’s environmental management system has earned ISO 14001 certification.
Toshiba is the first manufacturer in Japan to adopt R410A refrigerant for all its products.
The products resulting from Toshiba’s research and development dedicated to protecting our environment have earned
international recognition.

04
TOSHIBA History

Tanaka Seizo-sho
Hakunetsu-sha (1875)
(1890)
Tokyo Electric Company
(1899)
Shibaura Engineering
Works Co., Ltd. (1904)

Tokyo Shibaura
Electric Co., Ltd.
(Toshiba) (1939)
Toho Mining Co., Ltd.
(1933) Tokyo Fire Brick
1941
1943 Co., Ltd. (1918)
Toshiba Rolling Stock
Co., Ltd (1945) Dengyo-sha Prime
1950
Ichisuke Fujioka 1955 Mover Works Ltd. (1910)

Shikawajima-shibaura 1960 Toshiba EMI


Turbine Co., Ltd.
(1936) 1961
1971 Toshiba Silicone
Toshiba House and Co., Ltd.
Living Industry Co., 1972
Ltd.
Toshiba Electric
Toshiba Chemical 1974 1974 Equipment Corp.
Corporation
Toshiba Physical
TOSHIBA Distribution Co., Ltd.
CORPORATION
(1978)
1989 Toshiba Lighting &
Technology Corp.

1999
Toshiba Elevator and Toshiba Carrier Corp.
Building Systems 2001
Corporation

Hisashige Tanaka

Proven track record of more than 20 years of DC twin rotary compressor

05
Toshiba solutions
Toshiba offers a solution for all applications: residential, light commercial and larger commercial buildings.

Residential indoor units are designed to blend perfectly with all interiors and incorporate advanced filtration systems to
deliver optimum indoor air quality. For small commercial premises, products are designed to deliver top performance
combined with energy efficiency.

For larger applications, VRF systems combine flexibility, energy efficiency and respect for the environment, with a wide
choice of stylish indoor units.

Residential Light Commercial VRF

Absolute comfort
Toshiba commitment to people
drives a focused attention for the
details in every stage of the
development process, form
design to user field tests.
Therefore the products and
systems installed feature higher
standard of indoor air quality,
sound levels, energy savings and
environmental awareness.

06
Product Lineup

Cooling capacity
Residential
BTU K 18 24 30 36 48 60
Type kW 5.6 7.1 9.0 11.2 14.0 16.0
HP 2.0 2.5 3.2 4.0 5.0 6.2

RAS-BKS-Q

RAS-G2KS-Q

RAS-KSG

Light Commercial
BTU K 18 24 30 36 48 60
Type kW 5.6 7.1 9.0 11.2 14.0 16.0
HP 2.0 2.5 3.2 4.0 5.0 6.2
4-way Cassette
USP Series
Standard Duct
BSP Series
Ceiling
CSP Series
Floor Standing
RAV - FS8G

VRF
Outdoor Unit 4 HP 5 HP 6 HP 8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP

Mini SMMS-e

SMMS-e

22 - 56 HP available in combined module with an increment of 2HP.

07
Residential

08
At Toshiba air conditioning, we believe we can make a difference. As a global vision for our evolving world, we are
committed to advancing research and development of super energy-efficient, cleaner technologies and to innovate
products that not only use significantly less energy but help maintain air quality through state-of-the-art air purification
systems for the home. Intelligent ideas that use less of our Earth’s resources, without sacrificing your personal comfort.

Toshiba constantly works to ensure that our air conditioners help protect the environment while delivering reassurance
and reliability to users around the world.

Toshiba’s considerable efforts in terms of development in technology & commitment to keep earth green results in
reducing harmful gas effect on environment from start point.

Toshiba constantly works to ensure that our air conditioners help protect the environment while delivering reassurance
and reliability to users around the world. Toshiba has earned international praise for building energy-saving products, and
for its environmental oriented production facilities. Toshiba is the first manufacturer in Japan to adopt R410A refrigerant
for all its products.

True quality in the residential environment goes beyond control of the air filtration. With Toshiba residential air
conditioners, air quality is guaranteed by many stages of filtration and additional functions such as pre-treatment, removal
of fine particles, viruses, bacteria and allergens or total purification.

09
BKS Series

Stylish New Designs


Toshiba’s modern and stylish look complements any interior, while the
moon-white finish reflects sophistication and taste.

Toshiba Airconditioning, we care about Better Air...


Our products comply with With the fast increasing Our commitment is to save
RoHS regulations, ensuring waste stream, we aim to the earth and increase
prohibition of restricted minimize the impact of saving with improved
substances in every materi- electronic goods on the technology that provides
al of components. environment. Such inspira- superior control, cost
tion leads us to limit the efficiency and quieter
quantity of waste going to operation.
final disposal by applying
plastic that can be recycled.
Your health is our main concern
Today, we spend more time in the air conditioner room,
either in the office or at home, “Clean airflow” means
you can breathe with greater confidence. Self Cleaning Function
This function is designed to reduce
It simply refreshes you in a natural way the humidity that causes mould to
When you turn off your air conditioner, an internal fan form inside an air-conditioning unit.
automatically activates to dry out the coil. This removes
the moisture, which causes mould to form.

Toshiba Research Center understands your needs


Are you bored to adjust the temperature and airflow
every time you switch on the air conditioner to suit
with the condition you are in the room?
Normal Operation
How do i know that which temperature and airflow Moisture stays trapped inside during
setting is appropriate and provide comfort to me? operation.
I need my air conditioner to automatically switch on
before entering into the room and switch off before i
get out? Self-cleaning Function

20 minutes of fan operation after shut down


Hi-Power dries the moist air and helps reduce mould
formation.
Hi Power mode mades your room cool faster yet quiet when
operating.
Off timer
When you come home on the hot day, just press on the
“Hi-Power” button. Toshiba’s extra airflow rapidly deliver extra We design real time off feature, which can set off
cooling toroughout the room without making undesired noise. times or program a setting to repeat every 12
hours.
10
Powerful & Precise
Eco-Logic
Toshiba air conditioners have 5 fan-speed
Achieve energy-saving of up to 25% settings, including Auto Fan and Hi-power
compared with standard setting without modes. Choose from a gentle airflow right
sacrificing comfort. up to the full cooling or heating of Hi-Power
mode, which provides up to 1050 m3/h* of
air flow instantly.

The temperature is raised by 1°C after 1 Comfort-smart Airflow


hour and another degree after 2 hours,
which will be maintained until switching off. 790
830
900
With 11* louver setting, Toshiba Air
750
720
Conditioners allow you to adjust the airflow
precisely to the position that gives you the
greatest comfort. Alternatively, use the
swing feature to distribute air evenly
throughout the room.
Testing condition
Indoor temperature : Starting from 30°C
until it reaches a set-point temperature.
Comparison factor : Between to active and
inactive the “Eco-logic” function.
Testing period : Total 10 hours
Fan speed setting : Highest

Operating Mode
Select the operating Mode: Cooling, Dry
Mode (Dehumidification), Fan Only Heating
(only for heat-pump model) or Auto Change
over.

Temperature control

Swing & Fix Louver


Select your preferred airflow distribution: “Fix” to
ON / OFF
choose any on of the 12 louver positions or
“Swing” to automatically move between all
positions.
5-Selectable Fan Speeds plus Auto
Choose your desired airflow from the five fan
speeds or select the Auto Fan Speed mode and
let the air conditioner select for you.

ECO
Achieve energy-savings of up to 25% compared
with standard settings without sacrificing comfort.

Hi POWER
Select “Hi POWER” for extra airflow intensity that
will cool you down much faster than standard
operation.

OFF Timer
Toshiba remote control provides a very
convenient automatic stop operation,
programmable for 0.5, 1 . 0 , 1 . 5 , …, 9, 10, 11,
12 hours. 11
Cooling Only ( HIWALL SINGLE SPLIT TYPE) Technical specifications

Size 18K 24K


System

Indoor RAS-18BKS-Q RAS-24BKS-Q


Outdoor RAS-18BAS-Q RAS-24BAS-Q
Power supply (V/Ph/Hz) 240 / 1 / 50
Capacity (kW) 5.00 6.70
Cooling T1

Power Consumption (kW) 1.71 2.29


EER (Btu/W∙h) 9.98 9.98
Air flow volume (H/ M/ L) (m3/h) 1,050/ 790/ 720 1,260/ 1,050/ 820
Capacity (kW) 4.20 5.65
Cooling T3

Power Consumption (kW) 2.07 2.75


EER (Btu/W∙h) 6.92 7.01
Air flow volume (H/ M/ L) (m3/h) 1,050/ 790/ 720 1,260/ 1,050/ 820
HxWxD (mm) 320 x 1050 x 238 320 x 1050 x 238
Dimensions
FCU

Net Weight (kg) 14 13


Indoor Sound Pressure (dB) 47/45/42/40/36 51/49/46/43/40
HxWxD (mm) 550 x 780 x 290 550 x 780 x 290
Dimensions
CDU

Net Weight (kg) 37 46


Outdoor Sound Pressure (dB) 57 57
Chargeless (m) 15 15
Pipe

Maximum length (with charge) (m) 20 (20 g/m) 25 (30 g/m)


Maximum height (m) 8 10
Pipe dia. (Gas / Liquid) (mm) 12.7 / 6.35 15.88 / 6.35
Refrigerant R410a
Usable Range Temp Cooling (°C) Indoor: 21 ~ 32 °C , Outdoor: 21 ~ 52 °C

T1: Indoor 27° C dry-bulb / 19° C wet-bulb, outdoor 35° C


T3: Indoor 29° C dry-bulb / 19° C wet-bulb, outdoor 46° C

12
13
G2KS Series

Stylish New Designs


Toshiba’s modern and stylish look complements any interior, while the
moon-white finish reflects sophistication and taste.

Toshiba Airconditioning, we care about Better Air...


Our products comply with With the fast increasing Our commitment is to save
RoHS regulations, ensuring waste stream, we aim to the earth and increase
prohibition of restricted minimize the impact of saving with improved
substances in every materi- electronic goods on the technology that provides
al of components. environment. Such inspira- superior control, cost
tion leads us to limit the efficiency and quieter
quantity of waste going to operation.
final disposal by applying
plastic that can be recycled.

Technology for health through

Anti bacteria* : destroys up to 99.9% of bacteria

Deodorizing power: Absorbs and decomposes


Toshiba IAQ’s technology is able to seriously inhibit the smoke, ammonia, volatile organics, food smells
reproductive ability of harmful bacteria and viruses such and bad odors.
as H5N1 Avian Influenza. With Toshiba IAQ, your family
can breathe easy and your house will look like as if it has Prevent mould formation: Inhibits the formation
been spring cleaned. of mould and fungi.

Anti virus** : Avian Influenza virus

14
Your health is our main concern Self Cleaning Function
Today, we spend more time in the air conditioner room,
This function is designed to reduce
either in the office or at home, “Clean airflow” means you
the humidity that causes mould to
can breathe with greater confidence.
form inside an air-conditioning unit.
It simply refreshes you in a natural way
When you turn off your air conditioner, an internal fan
automatically activates to dry out the coil. This removes
the moisture, which causes mould to form.
Toshiba Research Center understands your needs Normal Operation
Moisture stays trapped inside during
Are you bored to adjust the temperature and airflow
operation.
every time you switch on the air conditioner to suit with
the condition you are in the room?
How do i know that which temperature and airflow
setting is appropriate and provide comfort to me? Self-cleaning Function

I need my air conditioner to automatically switch on 20 minutes of fan operation after shut
before entering into the room and switch off before i get down dries the moist air and helps
out? reduce mould formation.

Hi-Power

Hi Power mode mades your room cool faster yet Preset


quiet when operating.
Store your desired settings and activate them at the
When you come home on the hot day, just press touch of a button.
on the “Hi-Power” button. Toshiba’s extra airflow
Comfort Sleep
rapidly deliver extra cooling toroughout the room Hi Power mode mades your room cool
faster yet quiet when operating

without making undesired noise. Awake in the middle of the night because
you felt the room is too cold? Do you feel
One Touch My Comfort too cold during sleeping at night?
With Toshiba’s convenience feature,
Toshiba has assessed user preferences in your
when you activate the comfort sleep
region of the world to ensure that your needs can
button, your air conditioning system will
be fully catered for. The One Touch My Comfort
compensate for naturally lower night air
features customized temperature and airflow
temperatures so you can sleep in
settings, which will deliver you ultimate comfort
complete comfort.
with one simple push of the button.
Real time on-off
Eco-Logic We design real time on-off feature, which
Achieve energy-saving of up to 25% compared with standard can set on and off times or program a
setting without sacrificing comfort. setting to repeat every 24 hours.

Powerful & Precise


Cooling only
Toshiba air conditioners have
The temperature is raised by 1°C after 1 hour and another degree 5 fan-speed settings, including Auto Fan
after 2 hours, which will be maintained until switching off. and Hi-power modes. Choose from a
gentle airflow right up to the full cooling or
heating of Hi-Power mode, which
provides up to 1050 m3/h* of air flow
instantly.
Testing condition Comfort-smart Airflow
Indoor temperature : Starting from 30°C until it reaches a
set-point temperature. With 11* louver setting, Toshiba Air Conditioners
Comparison factor : Between to active and inactive the allow you to adjust the airflow precisely to the
“Eco-logic” function. position that gives you the greatest comfort.
Testing period : Total 10 hours Alternatively, use the swing feature to distribute air
evenly throughout the room.
900
830
Fan speed setting : Highest 720
750
790

15
Wired connectable remote controller

Consumer can decide either the remote controller


is wired or wireless at their own.
Basic functionality and features of wired controller
are the same as wireless controller.
No more unnecessary expense from lost of remote
controller once it is wired and fixed to wall.
Preset
Solution to operate air conditioner under one of
Store your desired setting and
safety requirement where wireless signal is
activate them at the touch of a
prohibited to avoid radio signal interference.
button.
Ideal for use in both residential and commercial
applications such as hospitals, hotels, school and Swing & Fix
office buildings. Select optimum air flow by selecting
ranged of fixed and Swing Louver
position.
Operating Mode Fan Speed
Select the operating Mode: Cooling, Dry Control your airflow with five fan
mode, Fan Only or Heating (only for speedor select auto fan speed to let
MODE
heat-pump model) your air conditioner do the thinking.

Timer Quiet
On and off timer or repeat By pressing the “Quiet” button on the
every 24 hours remote control, the indoor unit will be
operated at only 22dB*.

One Touch My Comfort


By pressing the “Quiet” button on the
remote control, the indoor unit will be
operated at only 22dB*.

Hi-Power
Extra airflow to rapidly reach your
desired temperature setting.
Eco-Lgic
Achieve energy-savings of up to
25% compared with standard
settings without sacrificing comfort.

Comfort sleep
For optimum comfort, set the
temperature to rise by 1°C after 1
hour, then another degree after 2
hours, which will be maintained until
morning.

16
Cooling Only ( HIWALL SINGLE SPLIT TYPE) Technical specifications

Size 30K
System

Indoor RAS-30G2KS-Q
Outdoor RAS-30G2AS-Q
Power supply (V/Ph/Hz) 240 / 1 / 50
Capacity (kW) 7.70
Cooling T1

Power Consumption (kW) 2.58


EER (Btu/W∙h) 10.18
Air flow volume (H x M x L) (m3/h) 1,100/910/720
Capacity (kW) 6.75
Cooling T3

Power Consumption (kW) 3.10


EER (Btu/W∙h) 7.43
Air flow volume (H/ M/ L) (m3/h) 1,100/910/720
Sound Pressure (dB) 50/48/46/44/42
Noise level

Indoor Noise
Sound Power (dB) 65
Sound Pressure (dB) 59
Outdoor Noise
Sound Power (dB) 74
HxWxD (mm) 320 x 1050 x 243
FCU

Dimensions
Net Weight (kg) 15
HxWxD (mm) 890 x 900 x 320
CDU

Dimensions
Net Weight (kg) 60
Chargeless (m) 15
Pipe

Maximum length (with charge) (m) 25 (30 g/m)


Maximum height (m) 10
Pipe dia. (Gas / Liquid) (mm) 15.88 / 6.35
Refrigerant R410a
Usable Range Temp Cooling (°C) Indoor: 21 ~ 32 °C , Outdoor: 21 ~ 52 °C

T1: Indoor 27° C dry-bulb / 19° C wet-bulb, outdoor 35° C


T3: Indoor 29° C dry-bulb / 19° C wet-bulb, outdoor 46° C

17
KSG Series

Stylish New Designs


Toshiba’s modern and stylish look complements any interior, while the
moon-white finish reflects sophistication and taste.

Toshiba Airconditioning, we care about Better Air...


Our products comply with With the fast increasing Our commitment is to save
RoHS regulations, ensuring waste stream, we aim to the earth and increase
prohibition of restricted minimize the impact of saving with improved
substances in every materi- electronic goods on the technology that provides
al of components. environment. Such inspira- superior control, cost
tion leads us to limit the efficiency and quieter
quantity of waste going to operation.
final disposal by applying
plastic that can be recycled.
Product Features
4-way auto swing Advanced Air Management System Easy Washable Grille
Hi power Mode Convenient PRESET function Auto Restart
Super Quiet Operation Sleep Timer High-efficiency compressor
(New R410A Tropical compressor)
Easy washable filter LCD Wireless Remote Control

Efficient Performance Quiet performance


It guarantees continuous exceptional performance The low noise compressor along with quiet
in extreme ambient conditions movement of air across the large condenser
fan has made this unit a quiet performer.
Hi Power
Whenever a rapid drop of temperature is needed, Corrosion-resistant casing
the hi power function can be easily activated. The The unit is built to last; its powder-coated
system will reach the desired temperature in the metal parts and UV-resistance, provide a
shortest possible time. strong protective armor from natural
Convenient PRESET elements.
You can set personalized function and let it
Sleep mode
memorize personalized operating mode and
The system will compensate for naturally
recallable at any time. All selected and
different night air temperature to maintain
memorized functions can be activated by pushing
complete comfort. The temperature will be
preset button.
increased or decreased by one degree
Four way air distribution after one hour, by another one degree after
Easy to personalize with the remote control two hours, and then keep it stable until
button, the flap swings can be manually or morning.
automatically directed in four sweep directions; Up and down control
up, down, left and right. The air discharge direction can be
Left and right control controlled to swing up and down and can
You can adjust the direction of the discharge air be fixed at a preferred position or at auto-
left or right. matic position by the remote control.

18
Wired connectable remote controller
Remote control display

Batteries exhausted indicator High Power

Preset

Transmission signal indicator Sleeping

Temperature selected

ON timer selected

OFF timer selected

Fan Speed Swing indicator

NO Key name Function


K1 ON/OFF On/Off Button
K2 Fan Fan Speen Button
K3 Temp up Temperature Setting Buttons
K4 Temp down Temperature Setting Buttons
K5 Mode Mode Buttons
K6 Hi Power Turbo Fan Speed
K7 ON Timer Reserve the unit ON time
K8 OFF Timer Reserve the unit OFF time
K9 Set Reservation Button
PRESET
K10 Clear CANCEL Button
K11
K12
K13 Sleep Sleep timer

K14 Preset Memorize a Personalized Operating


Mode
K15 Horizontal Swing Horizontal Louver Button

K16 Vertical Swing Vertical Louver Button

19
Cooling Only ( HIWALL SINGLE SPLIT TYPE) Technical specifications

Size 30K Btuh 36K Btuh


Indoor unit RAS-300KSG RAS-360KSG
Outdoor unit RAS-300ASG RAS-360ASG
Power Supply V/Ph/Hz 220 - 240 / 1 / 50
Cooling Capacity kW 8.50 9.82
Power Input T1 kW 2.50 2.98
EER Btu/W-h 11.60 11.26
Cooling Capacity kW 7.33 8.35
Power Input T3 kW 3.00 3.59
EER Btu/W-h 8.33 7.95
Indoor Unit
Air Flow (H / M / L) m3/hr 1445 / 1309 / 1190
Noise Level (Pressure, H / M / L) (dBA) 49 / 47 / 45 51 / 49 / 47
Fan Type Crossflow
Dimensions (W x H x D) mm 1460 x 340 x 282
Weight Kg 23
Outdoor Unit
Compressor type Type Scroll
Refrigerant Type R410A
Air Flow 3
m /hr 3400
Noise Level, Pressure dB(A) 51 52
Fan Type Propeller
Dimensions (W x H x D) mm 900 x 820 x 320
Weight Kg 58 70
Pipe Size (Gas / Liquid) mm 15.88 / 6.35
Pipe Length (Total / Height) Rmt 40 / 15
Operating temp. (Max) °C 52° 52°

T1: Indoor temperature @ 27° CDB / 19° CWB & outdoor temperature @ 35° CDB
T3: Indoor temperature @ 29° CDB / 19° CWB & outdoor temperature @ 46° CDB

20
21
Light Commercial

22
Toshiba Air Conditioning is committed to delivering the highest standard of quality and innovation across complete
product range.
Serving for more than 40 years Toshiba Air Conditioning has led the world in creating better air conditioning and setting
new standards in comfort, energy efficiency and climate control.

The Toshiba Air Conditioning product range encompasses comprehensive light commercial products. Toshiba’s excellent
technological innovation & design are reliable and run on R410A non-ozone depleting refrigerant.

Toshiba solutions for professionals, from professionals


Toshiba offers a solution for all applications: residential, light commercial and larger commercial buildings. Toshiba’s light
commercial units are designed to blend perfectly with all commercial requirements to deliver optimum indoor air quality.
For small commercial premises, products are designed to deliver top performance combined with energy efficiency.

A complete range of indoor units satisfies all commercial applications: ceiling, cassette, ducted & free stand units.
The enlargement of the range with maximum cooling capacities up to 17 kW allows addressing even more commercial
applications with larger volumes.

Absolute comfort
Toshiba’s commitment to excellence drives a companywide focus on attention to the details through every stage of the
development process, from design to user field tests. Installations using our products and systems therefore feature a
high standard of indoor air quality, sound levels, energy savings, and environmental awareness.

Toshiba light commercial systems deliver exceptional operating comfort with extremely high design units. With
state-of-the-art technologies, flexible controls and improved installation Toshiba brings comfort and convenience to any
business installation.

If you want high performance, compact units and optimum comfort, Toshiba has the ideal product for your requirements.
With the continuous improvement of the design, Toshiba offer enhances system efficiency and reduces noise levels.

The new technology applied to light commercial series is able to satisfy applications that require cooling at 54 °C.
Powerful cooling at high outdoor temperature in Middle East climate.

23
24
TOSHIBA LC key features
Piping flexibility
R410A refrigerant for all range. Toshiba leads the industry with
support for height differences of 25*/30** meters on
Better energy saving with DC motor for indoor unit.
a single system and 35*/50** meters max pipe length.
DC motor ducted for easy installation & flexibility.

Magic coil in FCU by Aqua resin coated to prevent dirt.


7F
6F

Single system
Height between 5F
4F
indoor & outdoor units 3F
25*m / 30m** 2F
1F

Calculated at 3.5 meters per floor


* 18 - 36
** 48-60

Product lineup 2.0HP 2.5HP 3.2HP 4.0HP 5.0HP 6.2HP

4-Way Cassette RAV-180USP-Q RAV-240USP-Q RAV-300USP-Q RAV-360USP-Q RAV-480USP-Q RAV-600USP-Q

RAV-180BSP-Q RAV-240BSP-Q RAV-300BSP-Q RAV-360BSP-Q RAV-480BSP-Q RAV-600BSP-Q


Standard Duct

RAV-180CSP-Q RAV-240CSP-Q RAV-300CSP-Q RAV-360CSP-Q RAV-480CSP-Q RAV-600CSP-Q


Ceiling

RAV-180ASP-Q RAV-240ASP-Q RAV-300ASP-Q RAV-360ASP-Q RAV-480AS8P-Q RAV-600AS8P-Q

Aqua Resin coated Indoor unit coil Environmentally friendly


So you can be sure of:

Water COMFORTABLE

Oil / Dirt With aqua Resin coated

Aqua Resin
coating

Without aqua Resin coated

Air conditioners can get very dirty inside, collecting Non CFC refrigerant helps reduce
bacteria and allergens. Aqua Resin coated coil reduces our environmental impact.
the formation of water or oil on the coil unit as well as
minimizes dust accumulation on the coil.

25
4-Way Cassette type

Compact sizing
Compact size especially in height (256mm), offers wide range
of installation opportunities to customer.

256 mm***
*2.0 - 3.3HP

RAV-xxxUSP Series A wireless remote control


is available for your
convenience.

Receiver
Receiver standard fitted in the panel
Controller
Option Option
Premium
Standard supply Easy installation: Low height
Built –in drain pump: 850 mm. from the bottom side
Including: Wireless remote controller

Accessory: Wired remote controller


Wireless remote RBC-AMT32E RBC-AMS54E-EN/ES 4Way cassette panel with receiver
Wired remote Wired remote

The wide air flow in all direction

850mm Drain Pump


Drain can be discharged upwards by 850mm from the
ceiling surface. It allows a piping layout with a high
degree of freedom depending on the installation
location.

300mm or less

850mm or less
Wide flow louver panels
Panel size is same for all
210mm models, RBC-U31PGXP(W)-IN1*.
It is easy to maintain a neat
appearance when multiple
units are installed.

*Available as an option.

26
4-Way Cassette Specifications
Equivalent HP 2.0 3.0 3.2
Indoor unit RAV-180USP-Q RAV-240USP-Q RAV-300USP-Q
Outdoor unit RAV-180ASP-Q RAV-240ASP-Q RAV-300ASP-Q

I Capacity T1 / T3 kW 5.30 / 4.51 7.10 / 6.04 8.80 / 7.48


n Cooling Power consumption T1 / T3 kW 1.64 / 1.90 2.20 / 2.54 2.52 / 2.90
d
o EER T1 / T3 (Btu /h / W) 11.0 / 8.1 11.0 / 8.1 11.90 / 8.80
o Standard air flow (H/M/L) m3/h 1050 / 870 / 780 1230 / 960 / 810 1820 / 1360 / 1080
r
Sound pressure level (H/M/L) dB(A) 34 / 32 / 31 38 / 36 / 35 43 / 39 / 37
u Indoor unit dimensions (H/W/D) mm 256 x 840 x 840 256 x 840 x 840 256 x 840 x 840
n
i Indoor unit weight kg 20 20 20
t Model name RBC-U31PGXP(W)-IN1
Panel Dimensions (H/W/D) mm 30 / 950 / 950
Weight kg 4
Power supply 1phase 220-240V 50Hz
O Compressor / Refrigerant type Rotary / R410 A
u
t Connecting pipe dia., Gas/Liquid side mm φ 12.7 / φ 6.4 φ 15.9 / φ 9.5 φ 15.9 / φ 9.5
d Min. pipe length m 3 3 3
o
o Max. pipe total length m 35 35 35
r Maximum height difference m 25 25 25

u Outdoor dimensions (H/W/D) mm 550 x 780 x 290 630 x 800 x 300 890 x 900 x 320
n Weight kg 44 49 65
i
t Sound pressure level dB(A) 50 53 56
Operating range °C 21 to 54°

Equivalent HP 4.0 5.0 6.2


Indoor unit RAV-360USP-Q RAV-480USP-Q RAV-600USP-Q
Outdoor unit RAV-360ASP-Q RAV-480AS8P-Q RAV-600AS8P-Q

I Capacity T1 / T3 kW 10.60 / 9.01 14.10 / 12.00 16.50 / 14.00


n Cooling Power consumption T1 / T3 kW 3.33 / 3.84 5.07 / 5.99 5.94 / 6.99
d
o EER T1 / T3 (Btu /h / W) 10.80 / 8.0 9.48 / 6.82 9.48 / 6.82
o Standard air flow (H/M/L) m /h
3
2010 / 1440 / 1170 2100 / 1440 / 1230 2200 / 1960 / 1780
r
Sound pressure level (H/M/L) dB(A) 46 / 40 / 37 48 / 42 / 39 48 / 45 / 43
u Indoor unit dimensions (H/W/D) mm 319 x 840 x 840 319 x 840 x 840 319 x 840 x 840
n
i Indoor unit weight kg 24 24 24
t Model name RBC-U31PGXP(W)-IN1
Panel Dimensions (H/W/D) mm 30 / 950 / 950
Weight kg 4
Power supply 1phase 220-240V 50Hz 3phase 380-415V 50Hz
O Compressor / Refrigerant type Rotary / R410 A Scroll / R410 A
u
t Connecting pipe dia., Gas/Liquid side mm φ 15.9 / φ 9.5 φ 19.5 / φ 9.52 φ 19.5 / φ 9.52
d Min. pipe length m 3 5 5
o
o Max. pipe total length m 35 50 50
r Maximum height difference m 25 30 30

u Outdoor dimensions (H/W/D) mm 890 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320
n Weight kg 70 109 -
i
t Sound pressure level dB(A) 56 63 63
Operating range °C 21 to 54°

T1 Rated conditions Cooling: Indoor air temperature 27°C DB / 19°C WB, Outdoor air temperature 35°C DB
T3: Indoor temperature @ 29° CDB / 19° CWB & outdoor temperature @ 46° CDB

27
Standard Duct type

Compact sizing
Compact size especially in height (275 mm.) offers wide range
of installation opportunities to customer.

275mm
275mm

RAV-xxxBSP Series
Flexible duct accessible: Design flexibility
Max. 120Pa with DC motor
Flexible Installation: Back or under air intake
High-lift drain pump
Controller 850 mm. from the bottom side
Option Option Option Filter an drain pump included as standard
Premium
Accessory: Wireless remote controller
Wired remote controller

Installation Flexibility
TCB-ACX32E2 RBC-AMT32E RBC-AMS54E-EN/ES Air filter and drain pump as High-lift drain pump:
Wireless remote kit Wired remote Wired remote standard Back or under air 850 mm, from bottom side
intake is selectable High-lift
Drain pump
drain pump

618 or less
Flexible duct is accessible, inside FCU

850 or less
300 or less

Allows complete design flexibility


Flexible duct accessible
Max external static pressure : Up to 120Pa
Long life filter included
Suction board cover

Polygonal rooms Narrow rooms Rooms with fixtures


Installation is flexible by changing from back air intake to
and obstacles under air intake. Suction board cover either fix at bottom
or back of unit.
Allows complete design flexibility and with high
static pressure all areas of the room can be reached
for even temperature distribution, no matter how Various installation way for air suction
complex the layout.

Built-in High-lift drain pump


The flexible piping layout is made possible by an
available drain-pump kit that raises the drain
piping up to 850mm. from the drain port.
Spigot shaped flange*
High static pressure
External static pressure can be raised as high as 120Pa,
so that all areas of the room can be reached for even
temperature distribution, no matter how complex the layout.

TCB-SF56C6BPE TCB-SF80C6BPE TCB-SF160C6BPE

*Available as an option.
28
Standard Duct Specifications
Equivalent HP 2.0 3.0 3.2
Indoor unit RAV-180BSP-Q RAV-240BSP-Q RAV-300BSP-Q

I Outdoor unit RAV-180ASP-Q RAV-240ASP-Q RAV-300ASP-Q


n Capacity T1 / T3 kW 5.30 / 4.51 7.03 / 5.98 8.80 / 7.48
d
o Cooling Power consumption T1 / T3 kW 1.72 / 1.90 2.28 / 2.52 2.75 / 3.15
o EER T1 / T3 (Btu/ h / W) 10.50 / 8.10 10.50 / 8.10 10.90 / 8.10
r
Standard air flow (H/M/L) m3/h 900 / 800 / 480 1350 / 1200 / 720 1350 / 1200 / 720
u External static pressure (factory setting) Pa 30-120Pa (30:Factory setting)
n
i Sound pressure level (H/M/L) dB(A) 38 / 34 / 31 41 / 38 / 36 41 / 38 / 36
t Indoor unit dimensions (H/W/D) mm 275 x 700 x 750 275 x 1000 x 750 275 x 1000 x 750
Weight kg 23 30 30
Power supply 1phase 220-240V 50Hz
O Compressor / Refrigerant type Rotary / R410A
u
t Connecting pipe dia., (Gas/Liquid side) mm φ 12.7 / φ 6.40 φ 15.9 / φ 9.5 φ 15.9 / φ 9.5
d Min. pipe length m 3 3 3
o
o Max. pipe total length m 35 35 35
r Maximum height difference m 25 25 25

u Outdoor unit dimensions (H/W/D) mm 550 x 780 x 290 630 x 800 x 300 890 x 900 x 320
n Weight kg 44 49 65
i
t Sound pressure level dB(A) 50 53 56
Operating range °C 21 to 54°

Equivalent HP 4.0 5.0 6.2


Indoor unit RAV-360BSP-Q RAV-480BSP-Q RAV-600BSP-Q

I Outdoor unit RAV-360ASP-Q RAV-480AS8P-Q RAV-600AS8P-Q


n Capacity T1 / T3 kW 10.60 / 9.01 14.10 / 12.00 17.50 / 14.90
d
o Cooling Power consumption T1 / T3 kW 3.51 / 3.79 4.71 / 5.45 6.29 / 7.41
o EER T1 / T3 (Btu/ h / W) 10.30 / 8.10 10.20 / 7.50 9.49 / 6.86
r
Standard air flow (H/M/L) m /h
3
2200 / 2100 / 1260 2400 / 2300 / 1760 2800 / 2700 / 1760
u External static pressure (factory setting) Pa 30-120Pa (30:Factory setting)
n
i Sound pressure level (H/M/L) dB(A) 44 / 42 / 39 48 / 43 / 40 51 / 43 / 40
t Indoor unit dimensions (H/W/D) mm 275 x 1400 x 750 275 x 1400 x 750 275 x 1400 x 750
Weight kg 40 40 40
Power supply 1phase 220-240V 50Hz 3phase 380-415V 50Hz
O Compressor / Refrigerant type Rotary / R410A Scroll / R410A
u
t Connecting pipe dia., (Gas/Liquid side) mm φ 15.9 / φ 9.5 φ 19.05 / φ 9.52 φ 19.05 / φ 9.52
d Min. pipe length m 3 5 5
o
o Max. pipe total length m 35 50 50
r Maximum height difference m 25 30 30
u Outdoor unit dimensions (H/W/D) mm 890 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320
n Weight kg 70 109 -
i
t Sound pressure level dB(A) 56 63 68
Operating range °C 21 to 54°

T1 Rated conditions Cooling: Indoor air temperature 27°C DB / 19°C WB, Outdoor air temperature 35°C DB
T3: Indoor temperature @ 29° CDB / 19° CWB & outdoor temperature @ 46° CDB

29
Ceiling type
Designed Wide Flap
The airflow angle is automatically set to the most suitable
setting according to your needs, an automatic swing mode
enables airflow to reach all areas of the room to create a
comfortable ambience.
New model
Previous model

RAV-xxxCSP Series 30% Extension

Smooth Curve Shape


Rounded design, this new models have been developed in
response to customers’ need for ceiling units that better match
Controller their room interiors.
Option Option Option
Premium
Smooth curve design

RBC-ACX33CE1 RBC-AMT32E RBC-AMS54E-EN/ES


Wireless remote kit Wired remote Wired remote

Wide flap designed: Large air volume with DC motor


Installable up to 4.3m* Easy installation: Free access hanger
Improve wire connection
The most suitable airflow Option part: Wireless remote controller kit
can be select maximum Drain Pump Kit with Anti-bacterial glass
installed ceiling up to
4.3 m.

4.3m. height with comfort


temperature.
*4.0HP
Easy installation : Free Access Hanger

Drain pump kit with glass built*


The Drain pump kit makes draining easier.
Glass built into Drain Pump kit helps reduce
mould formation.

Please fix the hanging plate on the ceiling firstly.


Next, hang the indoor unit on that plate.

TCB-DP31CE
*Available as an option. Drain pump kit Remove the hanging plate from indoor unit.

Saving the installation time and fee!

30
Ceiling Specifications
Equivalent HP 2.0 3.0 3.2
Indoor unit RAV-180CSP-Q RAV-240CSP-Q RAV-300CSP-Q
I
Outdoor unit RAV-180ASP-Q RAV-240ASP-Q RAV-300ASP-Q
n
d Capacity T1 / T3 kW 5.30 / 4.51 7.10 / 6.04 8.80 / 7.48
o
Cooling Power consumption T1 / T3 kW 1.64 / 1.90 2.20 / 2.51 2.52 / 2.90
o
r EER T1 / T3 (Btu/h / W) 11.0 / 8.1 11.0 / 8.20 11.90 / 8.80
Standard air flow (H/M/L) m3/h 900 / 720 / 540 1410 / 1000 / 750 1410 / 1000 / 750
u
n Sound pressure level (H/M/L) dB(A) 40 / 36 / 32 43 / 37 / 33 43 / 37 / 33
i
Indoor unit dimensions (H/W/D) mm 235 x 952 x 690 235 x 1269 x 690 235 x 1269 x 690
t
Weight kg 23 30 30
Power supply 1phase 220-240V 50Hz
O Compressor / Refrigerant type Rotary / R410A
u
t Connecting pipe dia.,Gas/Liquid side mm φ 12.7 / φ 6.40 φ 15.9 / φ 9.5 φ 15.9 / φ 9.5
d Min. pipe length m 3 3 3
o
o Max. pipe total length m 35 35 35
r Maximum height difference m 25 25 25

u Outdoor dimensions (H/W/D) mm 550 x 780 x 290 630 x 800 x 300 890 x 900 x 320
n Weight kg 44 49 65
i
t Sound pressure level dB(A) 50 53 56

Operating range °C 21 to 54°

Equivalent HP 4.0 5.0 6.2


Indoor unit RAV-360CSP-Q RAV-480CSP-Q RAV-600CSP-Q
I
Outdoor unit RAV-360ASP-Q RAV-480AS8P-Q RAV-600AS8P-Q
n
d Capacity T1 / T3 kW 10.60 / 9.01 14.10 / 12.00 16.50 / 14.00
o
Cooling Power consumption T1 / T3 kW 3.33 / 3.84 5.07 / 5.99 5.94 / 6.99
o
r EER T1 / T3 (Btu/h / W) 10.80 / 8.0 9.49 / 6.82 9.49 / 6.82
Standard air flow (H/M/L) m /h
3
1860 / 1350 / 1020 2040 / 1530 / 1200 2300 / 2040 / 1860
u
n Sound pressure level (H/M/L) dB(A) 43 / 38 / 33 48 / 42 / 35 48 / 44 / 41
i
Indoor unit dimensions (H/W/D) mm 235 x 1586 x 690 235 / 1586 / 690 235 / 1586 / 690
t
Weight kg 35 37 37
Power supply 1phase 220-240V 50Hz 3phase 380-415V 50Hz
O Compressor / Refrigerant type Rotary / R410A Scroll / R410A
u
t Connecting pipe dia.,Gas/Liquid side mm φ 15.9 / φ 9.5 φ 19.05 / φ 9.52 φ 19.05 / φ 9.52
d Min. pipe length m 3 5 5
o
o Max. pipe total length m 35 50 50
r Maximum height difference m 25 30 30

u Outdoor dimensions (H/W/D) mm 890 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320
n Weight kg 70 109 -
i
t Sound pressure level dB(A) 56 63 63
Operating range °C 21 to 54°

T1 Rated conditions Cooling: Indoor air temperature 27°C DB / 19°C WB, Outdoor air temperature 35°C DB
T3: Indoor temperature @ 29° CDB / 19° CWB & outdoor temperature @ 46° CDB

31
Floor Standing Type (FS Series)

Control Panel & Display


1. Power On/Off button
2. Temperature, Current time or
Reservation time setting button
3. Fan Speed
4. Display Change
5. Cooling
6. Fan
7. Auto Sweep
8. Timer
9. Filter Cleaning Alarm
10. Fan Speed Indication
11. Digital LED(Light Emitting Diode)
- Set by display change button
12. Panel Lock Indicating Lamp

Features:
1. Auto Sweep
The discharge air direction is controlled left
High energy efficiency
and right automatically.
Environmental friendly refrigerant (R410A)
Better Air distribution by..
Auto Swing Vertical Louver (Left and Right) 2. Panel Lock
Harder Horizontal Louvers It will be activated by pressing the filter &
Newly designed Operation Panel & Display display change button together, over 3
Shiny smoked panel & controllable buttons seconds. This will help to avoid miss
Safety Lock ON/OFF function handling or controlling by non-authorized
LCD wireless remote controller person.

3. Filter Cleaning Alarm


By showing the alarm, it helps to recognize of
filter cleaning timing.

4. Self Diagnosis
When abnormal operation is diagnosed,
shows the error code in display.

Control Panel & Display

Wind direction Temperature unit

Safety lock

6 5 4 3 2 1
Wind magnitude Operation mode

Filter cleaning request

Outdoor ON/OFF

Set or Room temperature


32
Technical specifications

Indoor unit RAV-480FS8G RAV-600FS8G


Outdoor unit RAV-480AS8G RAV-600AS8G
Type Cooling only
Power supply V-Ph-Hz 400~415-3-50 400~415-3-50
Capacity T1/T3 Cool(Btu/h) 47,000/41,000 60,000/52,500
Power input T1/T3 Cool(W) 4,450/5,500 5,750/7,000
Efficiency T1/T3 Cool(Btu/h W) 10.56/7.45 10.43/7.50
Remote Controller Wireless
Refrigerant (Net,5m) kg 2.15 (R-410A) 5.7 (R-410A)
Air flow (CMH) Indoor H/M/L 1680/1500/1260 2880/2820/2580
Indoor H/M/L(Pressure) dB(A) 54/51/48 59/57/55
Sound Standard
Outdoor H(Power) dB(A) 66 70
Indoor mm 580*1750*400 740*1800*440
Dimension (W*H*D)
Outdoor mm 1130*945*433 1130*945*433
Indoor kg 70 88
Weight
Outdoor kg 96 110
Gas/Liquid(mm) 22.2/9.52 22.2/9.52
Type Flare
Piping (OD,mm) Lenght(m) 5 5
Max lenght (m) 25 25
Max height difference(m) 15 15
Drain diameter mm OD18/ID16 OD18/ID16
Operating temp. range Outdoor deg°C 21~52 21~52

T1: Indoor temperature @ 27° CDB / 19° CWB & outdoor temperature @ 35° CDB
T3: Indoor temperature @ 29° CDB / 19° CWB & outdoor temperature @ 46° CDB

33
Business solution

34
TOSHIBA VRF History

Multi
System AC
1985
Multi System AC

Super Multi

1986
Multi controller

Wide Multi

1994
Optimal ref control
free branch piping

MMS

2000
Module CDU
Oil balance control

SMMS

2003
All inverter control
R410A DC twin rotary comp

Mini SMMS

2005
Small capacity VRF

SMMS-i

2010
3 inverter control,
High energy efficiency

SMMS-i
High Ambient
2012
3 inverter control,
Tropical VRF

SMMS-e Over 10 years experience


2015 with all inverter technology
Expanded product/
operation range, wave tool

Mini SMMS-e
32 Years experience
2016 in VRF technology
Small capacity hi-ambient VRF
35
36
MiNi-SMMS-e
The MiNi-SMMS-e system has been developed to achieve the best performance in a wide variety of commercial applica-
tions including shops, offices and large apartments, where unobtrusive appearance and quiet operation are important
advantages.

The extraordinary flexibility of this Toshiba system is guaranteed by the breadth of the range of SMMS-e indoor units – up
to 14 models MiNi-SMMS-e can be easily installed.

Key features
Best COP (4.06 for 4HP): represents state-of-art energy saving efficiency.
Wide range: up to 9 indoor units may be connected with a single outdoor unit.
DC Twin Rotary compressor delivers high efficiency and complete reliability.
Full SMMS-e control units available.
The compact design of the outdoor unit (smaller overall than standard VRF unit) means it can be easily installed virtually
anywhere; including on a balcony.

PMV Kit
The PMV kit is an option for supersilent operation, available for hotel rooms and residential applications where noise levels
are critical.
Ease of installation.
Integral condensate pump.
Low cost.

MiNi-SMMS-e is appropriate for Small and Medium-size building

RESTAURANT

OFFICE VILLA

37
MiNi-SMMS-e Technology

Fan against strong side wind

38
Toshiba’s unique energy efficient air conditioning innovations and
technologies deliver high energy savings.

Adopting the highly efficient new DC twin - rotary compressors and variable
refrigerant pressure controlled inverter realized greater energy efficient
performance.

EER COP
100% load 100% load
T1 T3 T1

4.5 5.0
4.06 4.03
4.0
3.65 4.55
3.5 4.5
3.05 3.04 3.03 4.30
3.0
4.22
2.5
4.0
2.0

1.5

1.0 3.5

0.5

0 3.0
4HP 5HP 6HP 4HP 5HP 6HP
Cooling Heating

Ultra-precise 0.1 Hz Infinity Variable Control


Adopting new compressor which adjusts infinity variable control reduce “Electricity consumption”

Compressor rotation speed Electricity consumption

0.1Hz Saving
Compressors(Hz)

consumption(W)
Electricity

Capacity(%) Capacity(%)
Near -seamless 0.1 Hz steps Compressor steps less,
Fine control minimizes energy loss when Electricity consumption
changing frequencies. decrease as well.

39
Operating Temperature

Utilizing the newly designed compressor, Mini SMMS-e can operate under the range of
outdoor ambience with the expansion of cooling and heating temperature from -20°C to 52°C.

Operation ambient temperature expansion

(Cooling : CDB,Heating : CWB)

Cooling
-5 - 52 ( °C )
Heating
-20 - 15.5 ( °C )

-20 0 25 52 ( C)

Quiet Operation

PMV kit for quieter operation


An optional PMV kit allows quieter placement by efficiently reducing the sound made by the refrigerant in the piping.

The PMV function is normally inside the indoor unit and


is the cause of most of the noise from the indoor unit.

PMV kit
(Optional part)

If the PMV function is removed from the indoor unit,


noise can be significantly reduced.

40
Comfort Operation with Low Sound
Night time operation mode
Sound level can be reduced by restricting the compressor and fan speeds.

Sound pressure Normal Night time


operation operation

Cooling 49 46
4HP
Heating 52 48

Cooling 50 46
5HP
Heating 53 48

Cooling 51 47
6HP
Heating 54 49

The optional PC bord: TCB-PCMO4E can be mounted in outdoor unit for sound reduction during night time.

Sound reduction and capacity limitation


The unit comes with a low sound mode*, which reduces operating sound at the programmed
activation time.
*with optional PC bord:TCB-PCMO4E and locally supplied timer/ switch

Outdoor unit During glow - noise dB(A) Capacity

Cooling Heating Cooling Heating

4HP 46 48 Approx.85% Approx.90%

5HP 46 48 Approx.80% Approx.80%

6HP 47 49 Approx.80% Approx.75%

Large-Diameter Propeller Fan


Rib adoption with rubber to reduce operating
sound of fan motor.

41
User Friendly

Wide Indoor unit lineup

With plenty types of indoor units to choose from, our line-up


includes combinations that are capable of air conditioning up
to 9 rooms.

You can always find a right type to suit with your property. A
neatness and well organized indoor space increase the
value of your property.

Outdoor Space Saving

Toshiba Mini-SMMS-e outdoors units are lightweight and


compact. With only one outdoor unit, the noise is significantly
reduced, it takes up much less space on your walls and
keeps your environment neat and peaceful.

42
Flexible Design and Easy Installation

MiNi-SMMS-e Piping Length

L1 Max length from CDU to FCU 100 m

Max. length 1st branch to the


L2 35 m
furthest FCU

L3 Max. main pipe length 65 m

L4 Max. total pipe length 180 m

Max. height CDU to FCU


H1 30/20 m
(Upper/Lower out door unit)

H2 Max. height FCU to FCU 15 m

15 m as height indoor unit to indoor unit is better for the


residential building

Easy installation
Possible to install the unit promptly and reduce both time and cost for installation.

MiNi-SMMS-e can be fit on your balcony, narrow street and any limited space.

250 mm

2230 mm

43
Technical specifications

Item

Model No. MCY-MHP0404HS8-ME MCY-MHP0504HS8-ME MCY-MHP0604HS8-ME

Outdoor Unit type Inverter Inverter Inverter

Power Supply V-Ph-Hz 380-415-3-50/380-415-3-60 380-415-3-50/380-415-3-60 380-415-3-50/380-415-3-60

Cooling Capacity* kW 12.6 14.0 15.5

Power Consumption kW 3.1 3.47 4.25

EER 4.06 4.03 3.65


T1
Heating Capacity* kW 14.2 16.0 18.0

Power Consumption kW 3.12 3.72 4.28

COP 4.55 4.3 4.22

Cooling Capacity* kW 11.4 12.6 14.0

T3 Power Consumption kW 3.74 4.15 4.62

EER 3.05 3.04 3.03

Starting Current Soft Start Soft Start Soft Start

Dimension (Height*Width*Depth) mm 1235*990*390 1235*990*390 1235*990*390

Unit Weight kg 124 124 124

Compressor Type Hermetric Twin rotary Hermetric Twin rotary Hermetric Twin rotary

Refrigerant Type(Quantity) kg R-410 A(6.4) R-410 A(6.4) R-410 A(6.4)

Max. No. of connected indoor units 6 8 9

Sound pressure Level(Cooling) dB(A) 49 50 51

Sound pressure Level(Heating) dB(A) 52 53 54

Refrigerant Piping (Gas side / Liquid Side) mm 15.9/9.5 15.9/9.5 19.1/9.5

Operation Temp range (Cooling) °C -5 to 52 °C -5 to 52 °C -5 to 52 °C

Operation Temp range (Heating) °C -20 to 15 °C -20 to 15 °C -20 to 15 °C

Note:
* Rated conditions
[T1]Cooling : Indoor 27 deg. C Dry Bulb /19 deg. C Wet Bulb, Outdoor 35 deg. C Dry Bulb.
Heating : Indoor 20 deg. C Dry Bulb, Outdoor 7 deg. C Dry Bulb / 6 deg. C Wet Bulb.
[T3]Cooling : Indoor 29 deg. C Dry Bulb /19 deg. C Wet Bulb, Outdoor 46 deg. C Dry Bulb.
Protection Devices: Discharge Temp. sensor,Suction Temp. sensor,High Pressure Sensor,
Low Pressure Sensor,Compressor case thermostat, PC Fuse Board.

44
MULTIPLE DESIGNS………COMPLETE SOLUTION
Room temperature goes state-of-the-art, when delivered by Mini SMMS-e. Be it a pleasing coolness in the height
of summer or the cosy warmth in the chill of winter. Mini SMMS-e creates a perfect environment that’s conducive
to people’s inherent wellbeing. Regardless if the installation is in a busy shop, office or a tranquil country spa hotel,
no other manufacturer offers such an extensive range of indoor units that can adjust and meet the most diverse of
requirements. Consistently and creatively putting you where you need to be – in your comfort zone!

HP 0,8 1,0 1,3 1,7 2,0 2,5 3,0 3,2 4,0 5,0 6,0
Model
kW 2,2 2,8 3,6 4,5 5,6 7,1 8,0 9,0 11,2 14,0 16,0

CASSETTE TYPES
Compact 4-way cassette type (620x620)
MMU-AP(...)MH-E
4-way cassette type
MMU-AP(...)HP1-E

2-way cassette type


MMU-AP(...)WH1

1-way cassette type


MMU-AP(...)YH1/SH1-E

DUCT TYPES
Slim duct type
MMD-AP(...)SPH1-E

Concealed duct type


MMD-AP(...)BHP1-E

Concealed duct high static pressure type


MMD-AP(...)6HP1-E

CEILING TYPES
MMC-AP(...)HP-E
HIGH WALL TYPES
Series 7
MMK-AP(...)7HP-E

Series 3
MMK-AP(...)3H1-E

FLOOR STANDING TYPES


Floor standing concealed type
MML-AP(...)BH1-E

Floor standing type


MMF-AP(...)H1-E

Console type
MML-AP(...)NH1-E

45
46
FFICIENCY

XPERIENCE

XCELLENCE

47
Energy saving

Greater efficiency performance


Adopting the highly efficient new DC twin-rotary compressors with
various technologies.

EER
Rated *
Cooling mode 50% load

w/w
7.0

6.5

6.0 5.83
5.69
5.5
5.19 5.11 5.05 5.01
5.0 4.96

4.5 4.42
4.21
4.0
3.81 3.81
3.5 3.85
3.52
3.0 3.43

2.5

2.0

8HP 10HP 12HP 14HP 16HP 18HP 20HP

Note:
The source voltage must not flucture more than ±10%.
* Indoor temperature: 26.7°C DB/19.4°CWB, outdoor temperature: 35°C DB (AHRI 1230 standard), power input of indoor units included.

48
Energy saving

The overall capacity range and the highest EER of 4.42 (15.08)
The SMMS-e has truly excellence as the industry’s top class in energy saving.

EER
Rated *
Cooling mode 50% load

BTU/W
22.0

20.0 19.89 19.41


18.0 17.71 17.44 17.23 16.92 17.09
16.0
15.08 14.36
14.0
13.0 13.0 13.14
12.0 12.01
11.74
10.0

8.0

6.0

4.0

2.0

8HP 10HP 12HP 14HP 16HP 18HP 20HP

Note:
The source voltage must not flucture more than ±10%.
* Indoor temperature: 26.7°C DB/19.4°CWB, outdoor temperature: 35°C DB (AHRI 1230 standard), power input of indoor units included.

49
Capacity range

Single unit capacity expanded


SMMS-e comes with 3 new larger capacity units, producing up to 20HP on a single module platform.

New

8 10 12 HP
14 16 HP
18 20 HP

SMMS-e
System capacity expanded
With the SMMS-e, it is now possible to connect up to 56HP in
one system. 56 HP

SMMS-e
Installation flexibility
While expanding the maximum combination from 48 to 56HP in
one system. This helps save more time and expense on
additional unit system required in the previous model. The new
compact unit design also increases more flexibility on
installation with less foot print.

56 HP
SMMS-e is capable of covering up to 20HP with a single
module. Reducing pipe work and overall installation time.

50
Operating temperature range

Outdoor temperature range


Utilizing the newly designed compressor, SMMS-e can operate under the wider range of
outdoor ambience with the expansion of cooling and heating temperature from -25°C to 54°C.
Operation ambient temperature expansion
(Cooling : CDB,Heating : CWB)

Cooling
-5 - 54 ( °C )
Heating
-25 - 15.5 ( °C )

-25 0 25 50 ( C)
Note : Based on equivalent piping length of 7.5 m and piping height difference of 0 m.

Heat pipe technology*


Thank to excellent heat sink with heat pipe technology, SMMS-e product can keep high
reliability at high ambient temperature.
Heat pipe

Vapor flow

Heat sink with heat pipe


Evaporation Adiabatic section Condensation - In order to cool for inverter
*18-20 HP - High ambient model

The external static pressure Air flow simulation diagram


The SMMS-e units are suitable for challenging installations
7F 50.0
where high external static pressure performance
48.4
6F 45.7

44.2
5F
42.6
up to 80* pa
40.9
4F
39.3

3F 36.8

35.1

2F 33.5

Note : This result is analytical simulation, that does not


guarantee actual temperatures.
Note: For ESP consult to local sales person.

51
Enhanced Comfort

New intelligent VRF control


Toshiba systems with intelligent VRF
control provide levels of comfort other
systems simply cannot match. That’s
because differing pipe lengths in commer- Oversupplied
cial buildings result in inconsistent levels
of performance, especially when several
indoor units are connected to a system.
This imbalance is caused by pressure loss
and thermal leaks that inhibit the optimum
refrigerant flow to each indoor unit.

For example, without intelligent control,


upper floor indoor units within VRF
systems place loads on the refrigerant
supply. This causes a delay before
enough refrigerant reaches the lower
floors to deliver efficient levels of
operation.

Without intelligent VRF control, refrigerant


flows unevenly throughout the structure,
typically oversupplying areas closer to the
outdoor unit and undersupplying areas
that are farther away.

Undersupplied

Without intelligent VRF control

52
Total system control

Total system control and


consistent room-to-room
temperature

The Toshiba intelligent VRF control


overcomes these issues by providing
precise control of indoor units with just
electrical wiring and copper refrigerant
tubing. It’s intelligent because it sends
more refrigerant to areas that need it, and
supplies less refrigerant to areas that
don’t. Comfort is distributed evenly
regardless of line length. As a result,
occupants enjoy greater overall comfort
whether they are closest to the outdoor
unit or farthest away.

Additionally, Toshiba SMMS-e systems


monitor the flow of refrigerant to each
indoor unit while tracking the model
number of each indoor unit, pipe length
between each indoor unit and the outdoor
unit, as well as data on operating
conditions. The system computes the
amount of refrigerant required by each
indoor unit and controls the unit’s pulse
motor valve to ensure optimal supply
across the system with height difference
between outdoor unit and indoor unit of up
to 90 meter.

Can be adjusted to maintain With intelligent VRF control, Toshiba


consistent temperature delivers consistent, room to room comfort
across several floors of a commercial
structure.

With intelligent VRF control

53
DC twin rotary compressor

Wide range compressor DLC coated vane


More powerful and efficient with the Increased hardness of the DLC coated vane
cutting-edge technology of compressor DC reduces friction and increase both reliability
Twin-Rotary operates in wider range of and performance.
rotation speed.

DLC Coat vane


DLC Coat vane
Rotary shaft roller

Crank

SMMS-e 64
cm3
Displacement volume Cylinder

* DLC: Diamond Like Carbon

12
2-stage vane
Contact portions
With 2-stage vane innovatively
designed to reduce friction while SMMS-e
2stage
increasing hardness and enhancing vane
performance at its best.

Shaft

Current-SMMS New-SMMSi
SMMS-e
Infinity variable control d ’s
W orl in*
Infinity variable control adjusts s t
be lass
compressor rotation speed in 0.1Hz its c
near-seamless 0.1 Hz steps.
Compressor Hz

Responding precisely to the capacity


needs of the moment, this fine
control minimizes energy loss when
changing frequencies, and also
creates a comfortable environment Capacit
y
subject to minimal temperature
variations.
Ultra-precise 0.1 Hz control over compressor rotation speed

54
Heat exchanger

New heat exchanger


New heat exchanger of SMMS-e increases from 2 to 3 rows, providing even more surface area of the total
pipe up to 13%.

SMMS-e Previous 8 mm dia


SMMS-e 7 mm dia

new heat exchanger

14HP 14HP
Previous model SMMS-e

*Increased
13%
the surface area
of the total pipe

Max. operation Min. operation


100% of 20% of
Variable heat exchanger the total capacity the total capacity

New system controls allows the outdoor unit to select


the most efficient heat exchanger size, which
matches the capacity load in order to provide higher
Use Nonuse
energy savings.

Use Use

Ex. Cooling operation in high Ex. Cooling operation in high


out door temp. out door temp.

4-way heat exchanger can realize balanced airflow heat exchanger


Heat exchangers are located on all four sides of the outdoor unit,
ensuring air flow is equal in all directions.
Machine room

SMMS-e
* For higher capacity model.

55
Precise refrigerant flow

One of the keys to delivering precision refrigerant flow and enhanced comfort is the Toshiba pulse motor valve (PMV)
control. The PMV control prevents refrigerant from flowing to indoor units that are not operating. The system reduces
bypass loss and achieves tighter control over the compressor capacity of the outdoor unit.

Outdoor unit

Pulse motor valve

Heat
exchanger

TC2 TCJ TC1


A B C

Indoor unit Refrigerant Refrigerant


sensor (In) sensor (Out)

The surplus represented by (A) is


diminished and the deficiency
The surplus represented by (B) is diminished represented by (D) is compensated
and the deficiency represented by (C) is for.
compensated for.

Target capacity
Capacity

(A) (B) (C) (D)

56
Reliability

Backup operation
In case of a compressor failure, SMMS-e can keep working with the backup operation under All Inverter Control to
compensate a failed compressor or header unit. This backup operation is available in both a single system or as
a module.

Single outdoor unit backup Module outdoor unit backup

Failed compressor Failed outdoor unit

Reliability rotational control


The rotational control in SMMS-e is designed to improve system reliability by controlling the operation of each
compressor to work equally under variable conditions.

80%

30%
Noon Comp1/Comp2
Ou
p rise tdo
or t
r tem em
doo pd
Out own
Morning Evening

Increase Air-conditionning load Decrease Air-conditionning load

Comp1/Comp2 Comp1/Comp2

57
Piping design flexibility

Total piping length Farthest pipe from 1st branch


Applied with Toshiba’s unique and greatly improved Even more convenient with the piping distance from
technology, SMMS-e can reach up to 1,000 meters the first branch to the furthest indoor unit at 90
maximum piping length. meters, increasing the flexibility of the installation
within the hotel or office building.

Total 1,000m
piping length SMMS-e Max. total length
Farthest pipe
from 1st branch 90m
Farthest equivalent length Height between indoor units
The maximum equivalent distance between outdoor Another industry’s top class is a maximum vertical
unit and farthest indoor unit tops at 235 meters, distance between indoor units which reaches up to
which tops the industry class. 40 meters, equal to an entire 11-storied building.
SMMS-e’s enhanced piping capabilities result in
more benefits for the system design, installation
flexibility, as well as the less installation cost.

40m Height between


indoor unit

Farthest
58
equivalent length 235m
Piping capabilities summary
Piping capability can provide more benefits for the system design, the installation flexibility, and the installation cost.

11F 11F
10F 10F
9F 9F
8F 8F
7F 7F
6F
5F
1 2 6F
5F
4 3
4F 4F
3F 3F
2F 2F
1F 1F

Total length 1,000m*


1. Farthest equivalent length 235m

2. Farthest pipe from 1st branch 90m**

3. Height between outdoor unit - indoor unit


90m***/40m
(outdoor unit above/below)

4. Height between indoor unit - indoor unit 40m

* : 34HP combination or more


** : 65m if the height piping length between outdoor unit and indoor unit is more than 3m
*** : Be sure to refer to local sales person for details of these conditions and requirements.

Slimmer pipe size

Piping saving costs


With the sub-cool heat exchanger less refrigerant is needed therefore now it is possible to use smaller pipes
and save in installation costs.

SMMS-e
ø 28.6 mm
NEW

One size down

20 HP

Sub-cool heat exchanger available in all models

59
Propeller fan

New advanced blade shapes for a better air flow management


Every single blade is designed with a unique profile, a solution that guarantees a
smoother air flow without turbulences. The new propeller deliver the same
amount of air with less sound pressure level.

Each blade has a unique profile Design improvements

New anti-eddy projections


A B on the back of the fan

C D New profiles of the reverse-arc


shaped wings

Sound pressure level

More quiet in comparison with the previous fan SMMS-e


In the same working condition the new design of
the propeller ensure a reduction of 1.5 dB
compared to the previous models.

1.5 dB
Reduce

Air volume

60
Heat
Connectable
exchanger
no. of indoor unit

Indoor lineup
Cooling capacity
Type kW 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0
HP 0.8 1.0 1.25 1.7 2.0 2.5 3.0 3.2 4.0 5.0 6.0 8.0 10.0

4-way air discharge


cassette type

Compact 4-way
cassette type (620 x 620)

2-way air discharge


cassette type

1-way air discharge


cassette type

Slim duct type

Concealed duct high


static pressure type

Concealed duct type

Ceiling type

High wall type


Series 3

High wall type


Series 7

Floor standing
concealed type

Floor standing
cabinet type

Console type

Fresh air intake


indoor unit type

Floor standing type

61
SMMSe wave tool

With SMMSe wave Tool, you can read and write data from outdoor unit directly on your smart phone without the needs
of connecting PC or opening cabinet.

By the new smart phone application, the testing and commissioning can be done without opening the cabinet.

SMMS-e

*For smartphone’s specification refer technical manual.

62
Available data
Whether the product data, system data, fault history or testing and commissioning, all can be obtained easily even in
case of under service maintenance or power failure. The data can be easily sent to the distant office via email. Possible
to receive system data by e-mail without moving from your office and the operation conditions can be checked in the
office.

In case of below situation


Installation
Service maintenance
Power failure Product
data

Fault
history
Available
System
data
data

Test operation
result

Smart phone

The Site The office

@lert

63
Outdoor units
Standard model

Capacity 8HP 10HP 12HP 14HP 16HP 18HP 20HP

Model Name
50 Hz MAP0806HT8P-ME MAP1006HT8P-ME MAP1206HT8P-ME MAP1406HT8P-ME MAP1606HT8P-ME MAP1806HT8P-ME MAP2006HT8P-ME
(MMY-)

Cooling capacity*¹ (kW) 22.4 28.0 33.5 40.0 45.0 50.4 56.0

Cooling capacity*² (kW) 20.3 25.2 26.8 32.5 36.0 42.8 44.8

Heating capacity (kW) 25.0 31.5 37.5 45.0 50.0 56.0 63.0
No’s of connectable
13 16 20 23 27 30 33
Indoor units

Capacity 22HP 24HP 26HP 28HP 30HP 32HP 34HP

Model Name
50 Hz AP2216HT8P-ME AP2416HT8P-ME AP2616HT8P-ME AP2816HT8P-ME AP3016HT8P-ME AP3216HT8P-ME AP3416HT8P-ME
(MMY-)

1206HT8P-ME 1206HT8P-ME 1406HT8P-ME 1406HT8P-ME 1606HT8P-ME 1606HT8P-ME 1806HT8P-ME


Units in combination
(MMY-MAP)
1006HT8P-ME 1206HT8P-ME 1206HT8P-ME 1406HT8P-ME 1406HT8P-ME 1606HT8P-ME 1606HT8P-ME

Cooling capacity*¹ (kW) 61.5 67.0 73.5 80.0 85.0 90.0 95.4

Cooling capacity*² (kW) 52.0 53.6 59.3 65.0 68.5 72.0 78.8

Heating capacity (kW) 69.0 75.0 82.5 90.0 95.0 100.0 106.0
No’s of connectable
37 40 43 47 50 54 57
Indoor units

Capacity 36HP 38HP 40HP 42HP 44HP 46HP 48HP

Model Name
50 Hz AP3616HT8P-ME AP3816HT8P-ME AP4016HT8P-ME AP4216HT8P-ME AP4416HT8P-ME AP4616HT8P-ME AP4816HT8P-ME
(MMY-)

1406HT8P-ME 1606HT8P-ME 1606HT8P-ME 1606HT8P-ME


Units in combination 1806HT8P-ME 2006HT8P-ME 2006HT8P-ME
1406HT8P-ME 1406HT8P-ME 1606HT8P-ME 1606HT8P-ME
(MMY-MAP) 1806HT8P-ME 1806HT8P-ME 2006HT8P-ME
1406HT8P-ME 1406HT8P-ME 1406HT8P-ME 1606HT8P-ME

Cooling capacity*¹ (kW) 100.8 106.4 112.0 120.0 125.0 130.0 135.0

Cooling capacity*² (kW) 85.6 87.6 89.6 97.5 101.0 104.5 108.0

Heating capacity (kW) 112.0 119.0 126.0 135.0 140.0 145.0 150.0
No’s of connectable
60 64 64 64 64 64 64
Indoor units

Capacity 50HP 52HP 54HP 56HP

Model Name
50 Hz AP5016HT8P-ME AP5216HT8P-ME AP5416HT8P-ME AP5616HT8P-ME
(MMY-)

1806HT8P-ME 1806HT8P-ME 2006HT8P-ME 2006HT8P-ME


Units in combination
1606HT8P-ME 1806HT8P-ME 2006HT8P-ME 2006HT8P-ME
(MMY-MAP)
1606HT8P-ME 1606HT8P-ME 1406HT8P-ME 1606HT8P-ME

Cooling capacity*¹ (kW) 140.4 145.8 152.0 157.0

Cooling capacity*² (kW) 114.8 121.6 122.1 125.6

Heating capacity (kW) 156.0 162.0 171.0 176.0


No’s of connectable
64 64 64 64
Indoor units

* Power: 3-phase 50 Hz 400V (380 - 415V)


* The source voltage must not fluctuate more than ±10%.
* Rated conditions
*¹ Cooling: Indoor air temperature 26.7°C DB/19.4°C WB, outdoor air temperature 35°C DB (AHRI 1230 standard)
*² Cooling: Indoor air temperature 29°C DB/19°C WB, outdoor air temperature 46°C DB (ISO 15042 standard)
Heating: Indoor air temperature 20°C DB, outdoor air temperature 7°C DB/6°C WB

64
High efficiency model

Capacity 16HP 18HP 20HP 30HP

Model Name
50 Hz AP1626HT8P-ME AP1826HT8P-ME AP2026HT8P-ME AP3026HT8P-ME
(MMY-)

MAP0806HT8P-ME MAP1006HT8P-ME MAP1006HT8P-ME MAP1006HT8P-ME


Units in combination
MAP1006HT8P-ME
(MMY-)
MAP0806HT8P-ME MAP0806HT8P-ME MAP1006HT8P-ME MAP1006HT8P-ME
Cooling capacity*¹ (kW) 44.8 50.4 56.0 84.0

Cooling capacity*² (kW) 40.6 45.5 50.4 75.6

Heating capacity (kW) 50.0 56.5 63.0 94.5


No’s of connectable
27 30 33 50
Indoor units

Capacity 32HP 34HP 38HP 40HP

Model Name
50 Hz AP3226HT8P-ME AP3426HT8P-ME AP3826HT8P-ME AP4026HT8P-ME
(MMY-)

MAP1206HT8P-ME MAP1206HT8P-ME MAP1406HT8P-ME MAP1406HT8P-ME


Units in combination
MAP1006HT8P-ME MAP1206HT8P-ME MAP1206HT8P-ME MAP1406HT8P-ME
(MMY-)
MAP1006HT8P-ME MAP1006HT8P-ME MAP1206HT8P-ME MAP1206HT8P-ME

Cooling capacity*¹ (kW) 89.5 95.0 107.0 113.5

Cooling capacity*² (kW) 77.2 78.8 86.1 91.8

Heating capacity (kW) 100.5 106.5 120.0 127.5


No’s of connectable
54 57 64 64
Indoor units

Y-shape branching joint Branch headers Outdoor unit connection piping kit

Appearance

(4-branch headers)

RBM - RBM - RBM - RBM - RBM - RBM - RBM - RBM -


Model name RBM-BT14E RBM-BT24E
BY55E BY105E BY205E BY305E HY1043E HY2043E HY1083E HY2083E

Max.4 branche s Max.8 branches


Total 6.4 Total
Usage or more 14.2 or
Total Total 25.2 Total
(Classification according to and more and Total 14.2 Total below 26.0 Total 26.0 or more
below 6.4 or more 14.2 or
indoor unit capacity code) below below Total or more Total
14.2 25.2 more and
below 14.2 and below below 14.2
below
25.2
25.2

* Power: 3-phase 50 Hz 400V (380 - 415V)


* The source voltage must not fluctuate more than ±10%.
* Rated conditions
*¹ Cooling: Indoor air temperature 26.7°C DB/19.4°C WB, outdoor air temperature 35°C DB (AHRI 1230 standard)
*² Cooling: Indoor air temperature 29°C DB/19°C WB, outdoor air temperature 46°C DB (ISO 15042 standard)
Heating: Indoor air temperature 20°C DB, outdoor air temperature 7°C DB/6°C WB

65
Outdoor unit specifications

Standard model (Single unit) Technical specifications


Equivalent HP 8HP 10HP 12HP

Model name Heat Pump 50Hz (MMY-) MAP0806HT8P-ME MAP1006HT8P-ME MAP1206HT8P-ME

Outdoor unit type Inverter


Power supply (*1) 3phase 4wires 50Hz 400V (380-415V)
Capacity 100% (kW) 22.4 28.0 33.5
Cooling (*) Power consumption (kW) 5.07 6.65 8.80
EER (Energy efficiency ratio) 4.42 4.21 3.81
Capacity 100% (kW) 20.3 25.2 26.8
Cooling (**) Power consumption (kW) 6.82 9.12 9.54
EER (Energy efficiency ratio) 2.98 2.76 2.81
Capacity 100% (kW) 25.0 31.5 37.5
Heating (*2) Power consumption (kW) 5.38 7.08 9.24
COP (Coefficiency of performance) 4.65 4.45 4.06
Starting Current (A) Soft Start
External dimensions (Height / Width / Depth) (mm) 1,800 / 990 / 780 1,800 / 990 / 780 1,800 / 990 / 780
Total weight Heat Pump (kg) 242 242 242
Compressor Quantity (nos) 2 2 2
Fan unit Air volume (m³/h) 9,700 9,700 12,200
Refrigerant R410A(Charged refrigerant amount) (kg) 11.5 11.5 11.5
Gas side (mm) Φ19.1 Φ22.2 Φ28.6
Refrigerant
Main pipe diameter Liquid side (mm) Φ12.7 Φ12.7 Φ12.7
piping
Balance pipe (mm) Φ9.5 Φ9.5 Φ9.5
Sound pressure level (Cooling/Heating) (dB(A)) 55 / 56 57 / 58 59 / 61
Sound power level (Cooling/Heating) (dB(A)) 74 / 74 74 / 74 80 / 82
Connectable indoor units (nos) 13 16 20

Standard model (Single unit) Technical specifications


Equivalent HP 14HP 16HP 18HP 20HP

Model name Heat Pump 50Hz (MMY-) MAP1406HT8P-ME MAP1606HT8P-ME MAP1806HT8P-ME MAP2006HT8P-ME

Outdoor unit type Inverter


Power supply (*1) 3phase 4wires 50Hz 400V (380-415V)
Capacity 100% (kW) 40.0 45.0 50.4 56.0
Cooling (*) Power consumption (kW) 10.5 12.8 13.1 16.3
EER (Energy efficiency ratio) 3.81 3.52 3.85 3.44
Capacity 100% (kW) 32.5 36.0 42.8 44.8
Cooling (**) Power consumption (kW) 12.2 13.2 15.0 15.7
EER (Energy efficiency ratio) 2.66 2.73 2.85 2.85
Capacity 100% (kW) 45.0 50.0 56.0 63.0
Heating (*2) Power consumption (kW) 10.6 12.50 13.6 16.5
COP (Coefficiency of performance) 4.25 4.00 4.12 3.82
Starting Current (A) Soft Start
External dimensions (Height / Width / Depth) (mm) 1,800 / 1,210 / 780 1,800 / 1,210 / 780 1,800/1,600/780 1,800/1,600/780
Total weight Heat Pump (kg) 299 299 370 370
Compressor Quantity (nos) 2 2 2 2
Fan unit Air volume (m³/h) 12,200 12,600 17,300 17,900
Refrigerant R410A (Charged refrigerant amount) (kg) 11.5 11.5 11.5 11.5
Gas side (mm) Φ28.6 Φ28.6 Φ28.6 Φ28.6
Refrigerant
Main pipe diameter Liquid side (mm) Φ15.9 Φ15.9 Φ15.9 Φ15.9
piping
Balance pipe (mm) Φ9.5 Φ9.5 Φ9.5 Φ9.5
Sound pressure level (Cooling/Heating) (dB(A)) 60 / 62 62 / 64 60 / 61 61 / 62
Sound power level (Cooling/Heating) (dB(A)) 80 / 82 81 / 83 81 / 83 80 / 82
Connectable indoor units (nos) 23 27 30 33

Protective devices: Discharge temp. sensor / Suction temp. sensor / High-pressure sensor Low-pressure sensor / High-pressure switch / PC board fuse
*1 The source voltage must not flucture more than ±10%.
* Indoor temperature: 26.7°C DB/19.4°CWB, outdoor temperature: 35°C DB (AHRI 1230 standard), power input of indoor units included.
** Indoor temperature: 29°C DB/19°CWB, outdoor temperature: 46°C DB (ISO 15042 standard), power input of indoor units included.
*2 Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB

66
Outdoor unit specifications

Standard model (Combination) Technical specifications


Equivalent HP 22HP 24HP 26HP

Model name Heat Pump 50Hz (MMY-) AP2216HT8P-ME MAP2416HT8P-ME MAP2616HT8P-ME

Outdoor unit type Inverter


Power supply (*1) 3phase 4wires 50Hz 400V (380-415V)
Outdoor unit
Heat Pump 50Hz (MMY-) MAP1206HT8P-ME MAP1006HT8P-ME MAP1206HT8P-ME MAP1206HT8P-ME MAP1406HT8P-ME MAP1206HT8P-ME
model
Capacity 100% (kW) 61.5 67.0 73.5
Cooling (*) Power consumption (kW) 15.5 17.6 19.3
EER (Energy efficiency ratio) 3.97 3.81 3.81
Capacity 100% (kW) 52.0 53.6 59.3
Cooling (**) Power consumption (kW) 18.66 19.1 21.7
EER (Energy efficiency ratio) 2.79 2.81 2.73
Capacity 100% (kW) 69.0 75.0 82.5
Heating (*2) Power consumption (kW) 16.3 18.5 19.8
COP (Coefficiency of performance) 4.23 4.06 4.16
Starting current (A) Soft start
Total weight Heat Pump (kg) 242 242 242 242 299 242
Compressor Quantity (nos) 2 2 2 2 2 2
Fan unit Air volume (m³/h) 12,200 9,700 12,200 12,200 12,200 12,200
Refrigerant R410A (Charged refrigerant amount) (kg) 11.5 11.5 11.5 11.5 11.5 11.5
Gas side (mm) Φ28.6 Φ34.9 Φ34.9
Refrigerant Liquid side (mm) Φ19.1 Φ19.1 Φ19.1
Main pipe diameter
piping
Balance pipe (mm) Φ9.5 Φ9.5 Φ9.5
Sound pressure level (Cooling/Heating) (dB(A)) 61.5/63 62/64 62.5/64.5
Sound power level (Cooling/Heating) (dB(A)) 81/83 83/85 83/85
Connectable indoor units (nos) 37 40 43

Standard model (Combination) Technical specifications


Equivalent HP 28HP 30HP 32HP

Model name Heat Pump 50Hz (MMY-) AP2816HT8P-ME AP3016HT8P-ME AP3216HT8P-ME

Outdoor unit type Inverter


Power supply (*1) 3phase 4wires 50Hz 400V (380-415V)
Outdoor unit
Heat Pump 50Hz (MMY-) MAP1406HT8P-ME MAP1406HT8P-ME MAP1606HT8P-ME MAP1406HT8P-ME MAP1606HT8P-ME MAP1606HT8P-ME
model
Capacity 100% (kW) 80.0 85.0 90.0
Cooling (*) Power consumption (kW) 21.0 23.3 25.6
EER (Energy efficiency ratio) 3.81 3.65 3.52
Capacity 100% (kW) 65.0 68.50 72.0
Cooling (**) Power consumption (kW) 24.4 25.4 26.4
EER (Energy efficiency ratio) 2.66 2.70 2.73
Capacity 100% (kW) 90.0 95.0 100.0
Heating (*2) Power consumption (kW) 21.2 23.1 25.0
COP (Coefficiency of performance) 4.25 4.11 4.00
Starting current (A) Soft start
Total weight Heat Pump (kg) 299 299 299 299 299 299
Compressor Quantity (nos) 2 2 2 2 2 2
Fan unit Air volume (m³/h) 12,200 12,200 12,600 12,200 12,600 12,600
Refrigerant R410A (Charged refrigerant amount) (kg) 11.5 11.5 11.5 11.5 11.5 11.5
Gas side (mm) Φ34.9 Φ34.9 Φ34.9
Refrigerant Liquid side (mm) Φ19.1 Φ19.1 Φ19.1
Main pipe diameter
piping
Balance pipe (mm) Φ9.5 Φ9.5 Φ9.5
Sound pressure level (Cooling/Heating) (dB(A)) 63/65 64.5/66.5 65/67
Sound power level (Cooling/Heating) (dB(A)) 83/85 83.5/85.5 84/86
Connectable indoor units (nos) 47 50 54

Protective devices: Discharge temp. sensor / Suction temp. sensor / High-pressure sensor Low-pressure sensor / High-pressure switch / PC board fuse
*1 The source voltage must not flucture more than ±10%.
* Indoor temperature: 26.7°C DB/19.4°CWB, outdoor temperature: 35°C DB (AHRI 1230 standard), power input of indoor units included.
** Indoor temperature: 29°C DB/19°CWB, outdoor temperature: 46°C DB (ISO 15042 standard), power input of indoor units included.
*2 Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB

67
Outdoor unit specifications

Standard model (Combination) Technical specifications


Equivalent HP 34HP 36HP 38HP

Model name Heat Pump 50Hz (MMY-) AP3416HT8P-ME AP3616HT8P-ME AP3816HT8P-ME

Outdoor unit type Inverter


Power supply (*1) 3phase 4wires 50Hz 400V (380-415V)
Outdoor unit
Heat Pump 50Hz (MMY-) MAP1806HT8P-ME MAP1606HT8P-ME MAP1806HT8P-ME MAP1806HT8P-ME MAP2006HT8P-ME MAP1806HT8P-ME
model
Capacity 100% (kW) 95.4 100.8 106.4
Cooling (*) Power consumption (kW) 25.9 26.2 29.4
EER (Energy efficiency ratio) 3.68 3.85 3.62
Capacity 100% (kW) 78.8 85.6 87.6
Cooling (**) Power consumption (kW) 28.2 30.0 30.7
EER (Energy efficiency ratio) 2.79 2.85 2.85
Capacity 100% (kW) 106.0 112.0 119.0
Heating (*2) Power consumption (kW) 26.1 27.2 30.1
COP (Coefficiency of performance) 4.06 4.12 3.95
Starting current (A) Soft start
Total weight Heat Pump (kg) 370 299 370 370 370 370
Compressor Quantity (nos) 2 2 2 2 2 2
Fan unit Air volume (m³/h) 17,300 12,600 17,300 17,300 17,900 17,300
Refrigerant R410A (Charged refrigerant amount) (kg) 11.5 11.5 11.5 11.5 11.5 11.5
Gas side (mm) Φ34.9 Φ41.3 Φ41.3
Refrigerant Liquid side (mm) Φ19.1 Φ22.2 Φ22.2
Main pipe diameter
piping
Balance pipe (mm) Φ9.5 Φ9.5 Φ9.5
Sound pressure level (Cooling/Heating) (dB(A)) 64.5/66 63/64 63.5/64.5
Sound power level (Cooling/Heating) (dB(A)) 84/86 84/86 84.5/86.5
Connectable indoor units (nos) 57 60 64

Standard model (Combination) Technical specifications


Equivalent HP 40HP 42HP 44HP

Model name Heat Pump 50Hz (MMY-) AP4016HT8P-ME AP4216HT8P-ME AP4416HT8P-ME

Outdoor unit type Inverter


Power supply (*1) 3phase 4wires 50Hz 400V (380-415V)
Outdoor unit
Heat Pump 50Hz (MMY-) MAP2006HT8P-ME MAP2006HT8P-ME MAP1406HT8P-ME MAP1406HT8P-ME MAP1406HT8P-ME MAP1606HT8P-ME MAP1406HT8P-ME MAP1406HT8P-ME
model
Capacity 100% (kW) 112.0 120.0 125.0
Cooling (*) Power consumption (kW) 32.6 31.5 33.8
EER (Energy efficiency ratio) 3.44 3.81 3.70
Capacity 100% (kW) 89.6 97.5 101.0
Cooling (**) Power consumption (kW) 31.4 36.6 37.6
EER (Energy efficiency ratio) 2.85 2.66 2.69
Capacity 100% (kW) 126.0 135.0 140.0
Heating (*2) Power consumption (kW) 33.0 31.8 33.7
COP (Coefficiency of performance) 3.82 4.25 4.15
Starting current (A) Soft start
Total weight Heat Pump (kg) 370 370 299 299 299 299 299 299
Compressor Quantity (nos) 2 2 2 2 2 2 2 2
Fan unit Air volume (m³/h) 17,900 17,900 12,200 12,200 12,200 12,600 12,200 12,200
Refrigerant R410A (Charged refrigerant amount) (kg) 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5
Gas side (mm) Φ41.3 Φ41.3 Φ41.3
Refrigerant Liquid side (mm) Φ22.2 Φ22.2 Φ22.2
Main pipe diameter
piping
Balance pipe (mm) Φ9.5 Φ9.5 Φ9.5
Sound pressure level (Cooling/Heating) (dB(A)) 64.0/65.0 65/67 66.5/67.5
Sound power level (Cooling/Heating) (dB(A)) 85/87 85/87 85.5/87.5
Connectable indoor units (nos) 64 64 64

Protective devices: Discharge temp. sensor / Suction temp. sensor / High-pressure sensor Low-pressure sensor / High-pressure switch / PC board fuse
*1 The source voltage must not flucture more than ±10%.
* Indoor temperature: 26.7°C DB/19.4°CWB, outdoor temperature: 35°C DB (AHRI 1230 standard), power input of indoor units included.
** Indoor temperature: 29°C DB/19°CWB, outdoor temperature: 46°C DB (ISO 15042 standard), power input of indoor units included.
*2 Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB

68
Outdoor unit specifications

Standard model (Combination) Technical specifications


Equivalent HP 46HP 48HP 50HP

Model name Heat Pump 50Hz (MMY-) AP4616HT8P-ME AP4816HT8P-ME AP5016HT8P-ME

Outdoor unit type Inverter


Power supply (*1) 3phase 4wires 50Hz 400V (380-415V)
Outdoor unit
Heat Pump 50Hz (MMY-) MAP1606HT8P-ME MAP1606HT8P-ME MAP1406HT8P-ME MAP1606HT8P-ME MAP1606HT8P-ME MAP1606HT8P-ME MAP1806HT8P-ME MAP1606HT8P-ME MAP1606HT8P-ME
model
Capacity 100% (kW) 130.0 135.0 140.4
Cooling (*) Power consumption (kW) 36.1 38.4 38.7
EER (Energy efficiency ratio) 3.6 3.52 3.63
Capacity 100% (kW) 104.5 108.0 114.8
Cooling (**) Power consumption (kW) 38.6 39.6 41.4
EER (Energy efficiency ratio) 2.71 2.73 2.77
Capacity 100% (kW) 145.0 150.0 156.0
Heating (*2) Power consumption (kW) 35.6 37.5 38.6
COP (Coefficiency of performance) 4.07 4.00 4.04
Starting current (A) Soft start
Total weight Heat Pump (kg) 299 299 299 299 299 299 370 299 299
Compressor Quantity (nos) 2 2 2 2 2 2 2 2 2
Fan unit Air volume (m³/h) 12,600 12,600 12,200 12,600 12,600 12,200 17,300 12,600 12,600
Refrigerant R410A (Charged refrigerant amount) (kg) 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5
Gas side (mm) Φ41.3 Φ41.3 Φ41.3
Refrigerant Liquid side (mm) Φ22.2 Φ22.2 Φ22.2
Main pipe diameter
piping
Balance pipe (mm) Φ9.5 Φ9.5 Φ9.5
Sound pressure level (Cooling/Heating) (dB(A)) 66.5/68.5 67/69 66.5/68
Sound power level (Cooling/Heating) (dB(A)) 85.5/87.5 86/88 86/88
Connectable indoor units (nos) 64 64 64

Standard model (Combination) Technical specifications


Equivalent HP 52HP 54HP 56HP

Model name Heat Pump 50Hz (MMY-) AP5216HT8P-ME AP5416HT8P-ME AP5616HT8P-ME

Outdoor unit type Inverter


Power supply (*1) 3phase 4wires 50Hz 400V (380-415V)
Outdoor unit
Heat Pump 50Hz (MMY-) MAP1806HT8P-ME MAP186HT8P-ME MAP1606HT8P-ME MAP2006HT8P-ME MAP2006HT8P-ME MAP1406HT8P-ME MAP2006HT8P-ME MAP2006HT8P-ME MAP1606HT8P-ME
model
Capacity 100% (kW) 145.8 152.0 157.0
Cooling (*) Power consumption (kW) 39.0 43.1 45.4
EER (Energy efficiency ratio) 3.74 3.53 3.46
Capacity 100% (kW) 121.6 122.1 125.6
Cooling (**) Power consumption (kW) 43.2 43.6 44.6
EER (Energy efficiency ratio) 2.81 2.80 2.82
Capacity 100% (kW) 162.0 171.0 176.0
Heating (*2) Power consumption (kW) 39.7 43.6 45.5
COP (Coefficiency of performance) 4.08 3.92 3.87
Starting current (A) Soft start
Total weight Heat Pump (kg) 370 370 299 370 370 299 370 370 299
Compressor Quantity (nos) 2 2 2 2 2 2 2 2 2
Fan unit Air volume (m³/h) 17,300 17,300 12,600 17,900 17,900 12,200 17,900 17,900 12,600
Refrigerant R410A (Charged refrigerant amount) (kg) 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5
Gas side (mm) Φ41.3 Φ41.3 Φ41.3
Refrigerant Liquid side (mm) Φ22.2 Φ22.2 Φ22.2
Main pipe diameter
piping
Balance pipe (mm) Φ9.5 Φ9.5 Φ9.5
Sound pressure level (Cooling/Heating) (dB(A)) 65.5/67 65.5/67 66.5/67.5
Sound power level (Cooling/Heating) (dB(A)) 86/88 86.5/88.5 86.5/88.5
Connectable indoor units (nos) 64 64 64

Protective devices: Discharge temp. sensor / Suction temp. sensor / High-pressure sensor Low-pressure sensor / High-pressure switch / PC board fuse
*1 The source voltage must not flucture more than ±10%.
* Indoor temperature: 26.7°C DB/19.4°CWB, outdoor temperature: 35°C DB (AHRI 1230 standard), power input of indoor units included.
** Indoor temperature: 29°C DB/19°CWB, outdoor temperature: 46°C DB (ISO 15042 standard), power input of indoor units included.
*2 Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB

69
Mounting surface
of bottom plate
Model: MMY-MAP0806HT8P-ME Foundation

60
MMY-MAP1006HT8P-ME

100
MMY-MAP1206HT8P-ME

(Anchor bolt hole pitch)

(Including steady leg)

(Anchor bolt hole pitch)


755

780

790

610

755
670
700
(Anchor bolt hole pitch 4-15x20

100
990 (Long hole)

60
700 Foundation
(Anchor bolt hole pitch)

50
1800
1595
(75) (*1)
Note:
1. If there is an obstacle at the upper side of the outdoor unit, set

687
the top end of the outdoor unit 2000mm apart from the obstacle.

(*1)
2. Limit the height of the obstacle surrounding the outdoor unit to

75

284
273
800mm or less from the bottom end of the outdoor unit.

(220)
160
3. Draw out the pipe procured locally to the front of the outdoor unit
horizontally and keep 500mm or more between the outdoor unit 500 L-shape pipe
and traversing pipe if placing pipe transversely. 85
(*1) Cutting position of L- shape pipe
4. Dimensional drawing of corrosion heavey protection model is
Square hole (for freight handling) 2-60X200
the same as that of standard model. Gas pipe connection port Ø A
Balance pipe connection port Ø 9.5
Liquid pipe connection port Ø 12.7
(Unit:mm)

Mounting surface
of bottom plate
Model: MMY-MAP1406HT8P-ME Foundation
60
100

MMY-MAP1606HT8P-ME
(Anchor bolt hole pitch)

(Anchor bolt hole pitch)


(Including steady leg)
755

780

790

610

670

755
920
100

(Anchor bolt hole pitch) 4-15x20


60

(Long hole) Foundation


920
1210 (Anchor bolt hole pitch)
50
1800
1595

(*1)
(75)

Note:
687

1. If there is an obstacle at the upper side of the outdoor unit, set


75

the top end of the outdoor unit 2000mm apart from the obstacle.
160
(220) (*1)

2. Limit the height of the obstacle surrounding the outdoor unit to


284
213

800mm or less from the bottom end of the outdoor unit.


3. Draw out the pipe procured locally to the front of the outdoor unit
horizontally and keep 500mm or more between the outdoor unit L-shape pipe
and traversing pipe if placing pipe transversely. 620
85

(*1) Cutting position of L-shape pipe


4. Dimensional drawing of corrosion heavey protection model is
Gas pipe connection port Ø 28.6
the same as that of standard model. Square hole (for freight handling) 2-60X200 Balance pipe connection port Ø 9.5
Liquid pipe connection port Ø 15.9

(Unit:mm)

70
Mounting surface

100
Model: MMY-MAP1806HT8P-ME Foundation

60
of bottom plate
MMY-MAP2006HT8P-ME

Anchor bolt hole pitch)


1500

755
610

670
(Including steady leg)
(Anchor bolt hole pitch)
755

780
790
Foundation

60
100
1310
1500
(Achor bolt hole pitch)

1310 4-15×20
4-15×20
(Anchor bolt hole pitch) (Long hole)
(For additional strength)
(Long hole) 1600

50
1800
1595
Note:
(75) (*1)
1. If there is an obstacle at the upper side of the outdoor unit, set

(*1)
the top end of the outdoor unit 2000mm apart from the obstacle.
687

75
2. Limit the height of the obstacle surrounding the outdoor unit to

(220)
160
800mm or less from the bottom end of the outdoor unit.

284
200
3. Draw out the pipe procured locally to the front of the outdoor unit
horizontally and keep 500mm or more between the outdoor unit
and traversing pipe if placing pipe transversely.
720 L -shape pipe
4. Dimensional drawing of corrosion heavey protection model is
85

(*1) Cutting position of L -shape pipe


the same as that of standard model.
Square hole (for freight handling) 2-60X200
Balance pipe connection port Ø 9.5 Gas pipe connection port Ø 28.6
Liquid pipe connection port Ø 15.9
(Unit:mm)

71
Indoor units line-up

4-way air discharge Compact 4-way cassette 2-way air discharge 1-way air discharge
Cooling capacity (HP equivalent) Concealed duct type
cassette type (620 × 620) type cassette type cassette type

007 type 2.2 kW (0.8HP) MMU-AP0077MH-E MMU-AP0072WH1 MMU-AP0074YH1-E MMD-AP0076BHP1-E

009 type 2.8 kW (1HP) MMU-AP0094HP1-E MMU-AP0097MH-E MMU-AP0092WH1 MMU-AP0094YH1-E MMD-AP0096BHP1-E

012 type 3.6 kW (1.25HP) MMU-AP0124HP1-E MMU-AP0127MH-E MMU-AP0122WH1 MMU-AP0124YH1-E MMD-AP0126BHP1-E

015 type 4.5 kW (1.7HP) MMU-AP0154HP1-E MMU-AP0157MH-E MMU-AP0152WH1 MMU-AP0154SH1-E MMD-AP0156BHP1-E

018 type 5.6 kW (2HP) MMU-AP0184HP1-E MMU-AP0187MH-E MMU-AP0182WH1 MMU-AP0184SH1-E MMD-AP0186BHP1-E

024 type 7.1 kW (2.5HP) MMU-AP0244HP1-E MMU-AP0242WH1 MMU-AP0244SH1-E MMD-AP0246BHP1-E

027 type 8.0 kW (3HP) MMU-AP0274HP1-E MMU-AP0272WH1 MMD-AP0276BHP1-E

030 type 9.0 kW (3.2HP) MMU-AP0304HP1-E MMU-AP0302WH1 MMD-AP0306BHP1-E

036 type 11.2 kW (4HP) MMU-AP0364HP1-E MMU-AP0362WH1 MMD-AP0366BHP1-E

048 type 14.0 kW (5HP) MMU-AP0484HP1-E MMU-AP0482WH1 MMD-AP0486BHP1-E

056 type 16.0 kW (6HP) MMU-AP0564HP1-E MMU-AP0562WH1 MMD-AP0566BHP1-E

072 type 22.4 kW (8HP)

096 type 28.0 kW (10HP)

Concealed duct High wall type High wall type


Cooling capacity (HP equivalent) Slim duct type Ceiling type
high static pressure type 3 series 7 series

007 type 2.2 kW (0.8HP) MMD-AP0074SPH1-E MMK-AP0073H1 MMK-AP0077HP-E

009 type 2.8 kW (1HP) MMD-AP0094SPH1-E MMK-AP0093H1 MMK-AP0097HP-E

012 type 3.6 kW (1.25HP) MMD-AP0124SPH1-E MMK-AP0123H1 MMK-AP0127HP-E

015 type 4.5 kW (1.7HP) MMD-AP0154SPH1-E MMC-AP0158HP-E MMK-AP0153H1

018 type 5.6 kW (2HP) MMD-AP0186HP1-E MMD-AP0184SPH1-E MMC-AP0188HP-E MMK-AP0183H1

024 type 7.1 kW (2.5HP) MMD-AP0246HP1-E MMD-AP0244SPH1-E MMC-AP0248HP-E MMK-AP0243H1

027 type 8.0 kW (3HP) MMD-AP0276HP1-E MMD-AP0274SPH1-E MMC-AP0278HP-E

030 type 9.0 kW (3.2HP)

036 type 11.2 kW (4HP) MMD-AP0366HP1-E MMC-AP0368HP-E

048 type 14.0 kW (5HP) MMD-AP0486HP1-E MMC-AP0488HP-E

056 type 16.0 kW (6HP) MMD-AP0566HP1-E MMC-AP0568HP-E

072 type 22.4 kW (8HP) MMD-AP0726HP-E

096 type 28.0 kW (10HP) MMD-AP0966HP-E

72
Floor standing Floor standing Floor standing Fresh air intake
Cooling capacity (HP equivalent) Console
cabinet type concealed type type indoor unit type

007 type 2.2 kW (0.8 HP) MML-AP0074NH1-E MML-AP0074H1-E MML-AP0074BH1-E

009 type 2.8 kW (1.0 HP) MML-AP0094NH1-E MML-AP0094H1-E MML-AP0094BH1-E

012 type 3.6 kW (1.25 HP) MML-AP0124NH1-E MML-AP0124H1-E MML-AP0124BH1-E

015 type 4.5 kW (1.7 HP) MML-AP0154NH1-E MML-AP0154H1-E MML-AP0154BH1-E MMF-AP0156H1-E

018 type 5.6 kW (2.0 HP) MML-AP0184NH1-E MML-AP0184H1-E MML-AP0184BH1-E MMF-AP0186H1-E

024 type 7.1 kW (2.5 HP) MML-AP0244H1-E MML-AP0244BH1-E MMF-AP0246H1-E

027 type 8.0 kW (3.0 HP) MMF-AP0276H1-E

030 type 9.0 kW (3.2 HP)

036 type 11.2 kW (4.0 HP) MMF-AP0366H1-E

048 type 14.0 kW (5.0 HP) MMF-AP0486H1-E MMD-AP0481HFE

056 type 16.0 kW (6.0 HP) MMF-AP0566H1-E

072 type 22.4 kW (8.0 HP) MMD-AP0721HFE

096 type 28.0 kW (10.0 HP) MMD-AP0961HFE

73
TO-RC-WiFi-1

Controls

74
75
Air-conditioning management system on site

TO-AC-KNX-64

KNX

TCB-IFCB640TLE

Analog I/F (DCvoltage)

TCB-IFLN642TLE
Open
Network LonWorks
System

TCB-IFMB641TLE

Modbus
RS485
TCC-LINK

BMS-IFBN640TLE

BACnet

BMS-IFLSV4E

RS485

Energy monitoring
Relay I/F Power Meter

Touch-screen Controller
BMS-CT5121E
Digital I/O Relay I/F
I/O
Device

Energy monitoring Relay I/F


Smart BMS Manager BMS-IFWH5E Power Meter
BMS-SM1281ETLE RS485
TCC-LINK

Digital I/O Relay I/F


BMS-IFDD03E
Intranet I/O
RS485 Device

Central Remote Controller

ON-OFF controller Schedule timer Central remote controller


TCB-CC163TLE2 TCB-EXS21TLE BMS-CM1280TLE

1. LonWorks : Registered trademark by Echelon corporation.


2. BACnet : ANSI/ASHRAE 135-1995, A data Communication Protocol for Building Automation and Control Network.
3. Modbus : Registered trademark by Schneider E.
4. KNX : Registered trademark by knx.org

76
Power peak-out control
board TCB-PCDM2E
Residential Product
External master ON/OFF
board TCB-PCMO2E
Error output control board
Error output control board
Compressor operation/ General Purpose I/F
TCB-IFCG1TLE
system operation ratio
TCB-PCIN4E

Super Digital Inverter


SMMS-e Digital Inverter

MiNi-SMMS

"1:1 model" connection


TCC-Link Interface
TCC-PCNT30TLE2

TCC-LINK

Remote ON/OFF
TCB IFCB-4E2

Cable for connector


CN32(TCB-KBCN32VEE)
CN60(TCB-KBCN60OPE)
CN61(TCB-KBCN61HAE)
CN70(TCB-KBCN70OAE)
CN73(TCB-KBCN73DEE)
CN80(TCB-KBCN80EXE)

Side remote Master remote GSM Modem Phone


GSM REMOTE CONTROL
I/F TCB-IFGSM1E

Wire remote controller/wireless remote controller

TO-RC-WiFi-1

Smart Phone Lite-Vision plus Wired remote controller Wired remote controller Simple remote controller Wireless remote Remote Sensor
Application Interface Remote Controller with Weekly timer RBC-AMT32(31)E RBC-AS41E2 controller TCB-TC41LE
TO-RC-WiFi-1 RBC-AMS54E-ES RBC-AMS41E
RBC-AMS54E-EN

77
Wired remote controller

Standard Remote controller


RBC-AMT32E

Standard wired remote controller can be


connected to a single indoor unit or a group
of up to 8 indoor units.
Power save operation limits the greatest
current value.The remote controller allows
error to be displayed while the protective
Lite-Vision plus Remote Controller device works or a error occurs.
RBC-AMS54E-ES
RBC-AMS54E-EN Remote controller with weekly timer
(7-day timer function)
Wired remote controller with a built in 7-day timer-featuring a new RBC-AMS41E
multi-language,
LCD display with backlight, energy saving options and a return back • Clock display
function. • Schedule timer:
• Possibility to set and display the room name to easily set-up and monitor Possible to program schedule timer (7-day
the working parameter. timer) function
• New modern and desirable controller design with menu driven display. Possible to program 8 functions for each day
• Save mode by schedule timer to optimise energy consumption. of the week
• Room temperature display always available. * The following items can be set in program:
• Two “Hot Keys” (F1, F2) for easy operation of air conditioner functions. operation time,
• Easy to read layout including display of indoor unit model name and serial operation start/stop, operation mode,
number. temperature setting, restriction on button
• Built-in backup power. Settings are kept in memory up to 72 hours in case operation.
of power failure.
• Remote TA sensor available in controller. Simple wired remote controller
• Can be connected to a single indoor unit or a group of up to 8 indoor RBC-AS41E
units.
• Start/Stop
• Temperature setting
• Air flow changing
• Check code display

Wireless remote controller

Wireless remote controller kit & sensor unit


(receiver unit)

• Start/Stop •Changing mode •Temperature RBC-AX33CE


setting • Airflow changing Integral receiver TCB-AX32E2
• Timer function (For ceiling) (MMC-AP***8HP-E) Stand alone receiver (For 4-way
Either “ON” time or “OFF” time or “CYCLIC” can (MMU-AP***4SH1-E) air discharge cassette, compact
be set how many 30 min. later ON or OFF is 4-way cassette (600 x 600),
operated. 2-way air discharge cassette,
• Control by 2 remote controllers is available. ceiling, concealed duct standard,
Two wireless remote controllers can operate slim duct, floor standing cabinet,
one indoor unit. The indoor unit can then be floor standing, 1-way discharge
operated separately from the two different cassette
locations. (MMU-AP ***4YH1-E/SH1-E)
• Check code display
* The wireless remote control cannot be
connected to concealed duct high static RBC-AX32U(W)-E
pressure type Integral receiver (For 4-way air
discharge cassette)
(MMU-AP***4HP1-E)

RBC-AX32UW(W)-E
Integral receiver (For 2-way air
discharge cassette)
( MMU-AP***2WH1)
78
Central remote controller

ON-OFF controller
TCB-CC163TLE2
• Individual control of up to
Central remote controller
16 indoor units.
BMS-CM1280TLE
• Setting of simultaneous ON/OFF
3times per day combined with the
• Operation
weekly timer.
Individual operation of 128 indoor units available
Return Back Operation
Weekly Schedule Operation*
(ON/OFF)
* Schedule timer necessary
• Monitoring
Zone setting (64 zones x 2)
Individual unit operation mode operation restriction
Alarm display
Control input
Status output Schedule timer
TCB-EXS21TLE
• Schedule timer mode
– 6 programmings per day
– Enabling 8 groups to be programmed
– A maximum of 64 indoor units can be
controlled
– A maximum of 100 hours back-up
power supply
• Weekly timer mode
– 7 types of weekly schedule and 3
programmings per day

Other

Remote sensor Wired remote controller for air to air heat exchanger
TCB-TC41LE NRC-01HE

Install this sensor when outside air • Up to 8 units of the Air to Air Heat Exchanger can be operated using this
has been introduced or when remote controller.
overcooling and overheating are to • Control by 2 remote controllers is available. Two remote controllers can
be minimised. operate a single Air to Air Heat Exchanger.
• Air conditioning units may be controlled in addition to controlling the Air to
Air Heat Exchanger.
• Central control allows linked ON/OFF operation of air conditioner and Air
to Air Heat Exchanger.
• Central control can be set to allow standalone operation of the Air to Air
Heat Exchanger.
• Switchable ventilation modes (Automatic/Air to Air/Normal)
• Switchable ventilation air volume (Extra-high/High-Low)

79
Central Control Device

Advance control systems

Smart Manager with Data Analyzer


The Smart Manager has the same hardware Control Function as the BMS-CM1280TLE Controller, but also
has the ability of control from a Local Area Network and , with the use of an additional Interface, is capable
of Energy Monitoring and Report Creation Functions. This controller is ideal where advanced control,
Energy Monitoring, advanced scheduling or access to individual Air Conditioners is required from
networked computer systems.

Web Browser Control Software Features


• List View available -Displays all Indoor Units from one screen
• Set View available – Shows Basic Indoor Unit settings on main screen g
• Advanced Operation and Master schedule functions available
BMS-SM1281ETLE • Up to 4 Concurrent users can be connected
• Up to 32 User accounts can be programmed with different levels of access
(at least 1 must be administrator level)

Power Meter Pulse signal


BMS-IFWH5E RS-485 Network

TCC-Link Line 1
Digital Input Output signal

TCC-Link Line 2
BMS-IFDD03E

Digital Inputs Digital Outputs

TCB-PCNT30TLE2*

NETWORK HUB

* TCC-Link Adaptor for Digital/Super Digital Indoor Units.

Up to 32 User accounts
Max. 4 Concurrent Users

Equipment List
Device Number of pieces Description

BMS-SM1281ETLE 1 Up to 128 indoor unit can be connected to Smart Manager


BMS-IFDD03E Up to 4 Boards Interface for Digital Input & Outputs. Can connect up to 8 Power Meters per Board (Optional)
BMS-IFWH5E Up to 4 Boards Interface for Power Meter (Energy Monitoring Option only)

Locally Procured Item


Energy consumption history (days) Energy consumption comparison Alarm list Energy consumption history (hours)

Device Number of pieces Description


TOSHIBA| 165
Power Meter Digital Energy Meter with Pulse Output ( Energy Monitoring Option only)
PC For Operation Monitoring
T_12_CT_GEN_EN__print.indd 165 02/03/12 14.31

Network Hub For LAN Connection.

Energy consumption history (days) Energy consumption comparison Alarm list Energy consumption history (Hours)

80
62

Advance control systems

Touch-screen controller

• Touch-screen controller
Using the touch-screen controller provides a clear display and enables easy operation.
A maximum of 512 units are controllable using the one-touch controller.

• Function
– Operation monitoring
– Operation control
– Operation Schedule
– Error Code
Touch-screen Controller – Alarm List
BMS-CT5121E – Energy monitoring/Billing
– Digital I/O Signal Control
– Web function
– Email alert
– Graphical report
– Building layout

Up to 8 Up to 8 Up to 8
Relay Interface BMS-IFLSV4E Relay Interface BMS-IFWH5E Relay Interface BMS-IFDD03E
For TCS-NET For Energy Monitoring For Digital I/O
(Optional) (Optional)

CONTROL WIRING
RS-485 Network

TCS-Net Relay I/F Energy Monitoring I/F Digital Input/Output I/F


BMS-IFLSV4E BMS-IFWH5E BMS-IFDD03E

TCC-Link Network Digital I/O


• Power Meter
(Local Supply)
1 kWh/pulse or 10 kWh/pulse Digital Input 1
(Pulse duration 50 to 1000 ms)
(Maximum 8 power meter per interface)
Digital Input 8

Digital Output 1
Power Meter 1

- Digital Output 4

Power Meter 8 Network Hub

PC for Energy Monitoring


+
Web function

81
Open network systems

BACnet ®
BACnet Interface Features
The Toshiba BMS-IFBN640TLE BACnet
Interface can be connect to the TCC-Link • Maximum 64 Indoor Units/Groups and 16
Central Control Network to enable Outdoor Systems can be connected to a
control of the attached Air Conditioner single Interface.
product from a BACnet Building • TCB-PCNT30TLE2 Network adaptor
Management System. required for connection of DI/SDI to
BACnet System.

TCC-Link Network

Sample BACnet System

BMS-IFBN640TLE

TCB-PCNT30TLE2*

* TCC-Link Adaptor for Digital/Super Digital Indoor Units.

KNX ®

KNX Interface
The KNX interface manages the Toshiba VRF System air conditioning system as a KNX®
device to communicate with the custormer s Home automation.
Accessible to 64 units per one ,
Signals and provides the following functions:
– ON/OFF
– Mode: cool/heat/fan
– Air flow and fan speed
TO-AC-KNX-64 – Temperature setting
– Filter reset

KNX Control Panel

Main bus
KNX Network

KNX Interface
TO-AC-KNX-64

Lighting Blind & Electrical Audio &


Shutter appliance Video

82
Open network systems

LonWorks ®

LonWorks Interface
The LonWorks interface manages the SMMS-i air conditioning system as
a Lon device to communicate with the custormer’s Building Management
System and to monitor operational status.
A maximum of 64 units are controllable per interface.

• SNVT signal • Monitoring


Signals and provides the following functions: – ON/OFF
Object signals command • Mode
LN Interface – ON/OFF – Cool/heat/fan/failure
TCB-IFLN642TLE – Mode: cool/heat/fan – Temperature setting
– Temperature setting – Room temperature
– Central/local – Central/local, etc.

Main Bus

Local supply
LN Interface
TCB-IFLN642TLE

Modbus ®
Modbus Interface
The Modbus® interface manages the Toshiba VRF System air conditioning system as a Modbus®
device to communicate with the custormer’s Building Management System.
Accessible to 64 units per one TCB-IFMB641TLE, 15 TCB-IFMB641TLEs on one
Modbus® Master (prepared by user).

Signals and provides the following functions:


– ON/OFF
– Mode: cool/heat/fan
– Air flow/Louver setting
Modbus Interface – Temperature setting
TCB-IFMB641TLE – Filter reset
– Accumulated operation time, etc.

Local supply
Main Bus

Modbus® Interface
RS-485 TCB-IFMB641TLE

1. LonWorks®: Registered trademark Echelon corporation


2. BACnet®: ANSI/ASHRAE 135-1995, A data Communication Protocol for Building Automation and Control Networks.
3. Modbus® is a registered trademark of Schneider E.

83
Smart phone apps

Smart Phone Application Interface


TO-RC-WiFi-1
User can remotely manage an Air Conditioning system using all sort of mobile devices such as
Smartphones, Tablets and PC. Internet connection is necessary for operation.
Wi-Fi adapter connect with indoor unit on wired remote controller’s connection terminal ( A/B).
Two type of connection possible with Toshiba LC & VRF’s Indoor unit.
1:1 Individual i.e each indoor unit requires one adapter.
Group Control ( Up to 8 Indoor Unit ).

Toshiba
2 5

Internet
A B

4
3

Function Setting Monitor


On/Off  
Mode Auto, Heat, Cool, Dry, Fan 
Set Point 18 - 29° C 
Fan speed Auto, Low, Medium, High 
Louver Swing, Fix 
Smart Phone Controls Apps
Fault Code Reset Hex

VRF AHU-Dx kit

VRF DX Kit
The VRF DX Coil Interface enables a third party air handling unit with a DX Coil to be connected to a Toshiba VRF system. The interface consists
of a VRF DX Coil Controller (MM-DXC010 / MM-DXC012) and a VRF DX Coil Valve Kit (MM-DXV080 / DXV140 / DXV280).

MM-DXC010 VRF DX COIL CONTROLLER (Individual / Header)

MM-DXC012 VRF DX COIL CONTROLLER (Follower)

MM-DXV080 VRF DX COIL VALVE KIT (5.6kW, 7.1kW, 8.0kW)

MM-DXV140 VRF DX COIL VALVE KIT (11.2kW, 14.0kW, 16.0kW)

MM-DXV280 VRF DX COIL VALVE KIT (22.4kW, 28.0kW)

Product Features
DX Interface SMMSe diversity ratio: 60% to 110%
• Compatible with Toshiba control accessories.
• External ON / OFF input.
• Safety cut out input (recommended for fan failure input).
• Air temperature control achieved using TA sensor positioned in return air stream (set with remote controller).

0~10V Demand Control Options.


VRF DX kit with 0~10V Demand Control Options.
0-10V AHU DX Coil Interface enables BMS capacity demand control of Toshiba Outdoor units connected to a DX Coil (with a field supplied AHU).
It is compatible with either a Toshiba LC system or a Toshiba VRF system. DX Interface SMMSe diversity ratio: 75% - 100%
RBC-DXC031 LC / VRF DX CONTROLLER (0-10V AHU)
MM-DXV141 VRF DX PMV (16.0kW) [6.0HP]
MM-DXV281 VRF DX PMV (22.4kW, 28.0kW) [8.0HP / 10.0HP]

84
NOTES

85
AHIC062017_G_T3_Qatar

Notice: Product listed in this leaflet use HFC refrigerant R410A with a GWP of 2,088*.
Toshiba is committed to continuously improving its products to ensure the highest quality and reliability standards and to meet local regulations and market
requirements. All features and specifications are subject to change without prior notice.

* The GWP value is calculated based on information provided in the EU F-gas Regulation and IPCC Fourth Assessment Report.

S-ar putea să vă placă și