Sunteți pe pagina 1din 1

WATER TANK WATER TANK WATER TANK

WATER TANK

PARAPET WALL PARAPET WALL


PARAPET WALL PARAPET WALL

DOOR

FGL
FGL FGL FGL
FRONT SIDE ELEVATION-A BACK SIDE ELEVATION -B ELEVATION -C ELEVATION -D

1 2 3 4

B Y
V V V V WATER TANK WATER TANK GL GL
PARAPET WALL PARAPET WALL
A

Z Z
DRINKING
WATER
WC WC WC R.C.C SLAB
URINALS

D2 D2 D2
X X
15mm DROP(TYP)

PUSH BUTTON TAP


MIRROR
W1
+0.600m Lvl.
D C

W2
D2 D2 SLOPE M-15 PCC
1:100

TYP. STONE WALL FOOTING


100mm
TELE PHONE +0.600m Lvl. SLOPE CERAMIC
BOOTH 1:100 GUTTER
BATH BATH D2
FGL FGL FINISHED
FLOOR
100mm Thk. P.C.C LEVEL
100mm Thk. P.C.C M-10 COMPACTED EARTH
D1 D1 COMPACTED 150mm SAND FILLING
B EARTH FILLING 150mm SAND FILLING FILLING

V V W3 SECTION-XX SECTION-YY
A SECTION-ZZ
TREAD 250 Y
RISER 150
General Specification
230 MM THK. (OUTER WALL) BRICK WALL USING CM 1:6 115 MM THK. (INNER WALL ) BRICK PAINTING FOR ONE COAT OF PRIMAR AND TWO COATS OF WATERPROOF
B1b WALL USING CM 1:4 WITH HOOP REINFORCEMENT AT EVERY FOURTH COURSE ALL BRICKS INTERNAL WALL CEMENT BASED PAINT OF APPORVED QUALITY AND SHADE
B1a B1c WALLS
MASONRY WALLS SHALL BE CONSTRUCTED FROM BRICKS WITH MINIMUM CRUSHING
ALL EXTERNAL SUFRACE ABOVE GROUND LEVEL SHALL HAVE ONE COAT O AND TWO
STRENGTH OF 5 N/MM² ON GROSS AREA UNLESS SPECIFIED OTHERWISE PAINTING FOR
GROUND FLOOR PLAN EXTERNAL WALL
COATS OF WATERPROOF CEMENT BASED PAINT OF APPROVED QUALITY AND SHADE. A
COAT OF SILICONE WATER REPELLENT PAINT SHALL ALSO BE APPLIED THEREON.
S2 S3 ALL INTERNAL MASONARY SURFACES SHALL HAVE 20 MM THICK SAND FACED CEMENT
S1
120mm th. 120mm th. PLASTER IN CEMENT MORTAR (1:4) WITH NEAT LIME OR NEERU FINISH ON TOP. PAINTING FOR
120mm th. 2 COATS OF SYNTHETIC ENAMAL PAINT OVER ONE COAT OF RUST PROOF PRIMAR
STEEL WORK
ALL EXTERNAL MASONARY SURFACES SHALL HAVE 20 MM THICK SAND FACED CEMENT
ROOF DRAINAGE FOR ROOFING DRAINAGE P.V.C. RAINWATER DOWNTAKES WITH BELL MOUTH
PLASTER IN CEMENT MORTAR (1:3) IN TWO COATS. WATERPROFFING COMPOUND OF APPROVED
PLASTERING MAKE AND QUALITY SHALL BE ADDED TO THE CEMENT MORTAR IN PROPORTIONS AS SPECIFIED THE DAMP PROOF COUARSE SHALL RUN WITHOUT BREAK THROUGHT THE LENGTH OF THE
BY THE MANUFACTURER. DAMP PROOF WALL EVEN UNDER THE DOOR OR OTHER OPENINGS. DAMP PROOF COURSE SHALL BE
1 100∅ P.V.C RAIN WATER 2 3 1Nos.-SINTEX OR EQUIVALENT 4 COARSE CONSIST OF 40 THICK CEMENT ADMIXTURE CONFORMING TO IS 2645 IN PROPORTION AS
DOWNTAKE PIPE WITHOUT TANK 5000 LITERS CAPACITY 6 MM THICK NEERU FINISH PLASTER TO CEILING DIRECTED BY MANUFACTURER.
GRATING(TYP) (TYP) CONCRETE MIX
FLOORING CONCRETE MIX M 25 FOR RCC BEAM & SLAB
WATER 600 X 450 X 20 mm THK POLISHED KOTA STONE FLOORING PLACED IN C.M. 1:3 TO SPECIFICATION
A GIVE AN OVERALL THICKNESS OF 50 mm MARBAL FOORING IN C.M. 1:4
FOUNTAIN ALL REINFORCEMENT BARS SHALL BE TMT BARS OF
TOILET BLOCK REINFORCEMENT
115 Thk. BRICK WALL GRADE Fe-500 (YEILD STRENGTH 500 N/MM²)
300mm HIGH(TYP) SKIRTING AND
DADO TOILET
WATER CERAMIC TILE DADOING UPTO 2100 mm HIGH AND MARBLE DADOING IN C M 1:3
FOUNTAIN
B2

B3

B3

B2
SCHEDULE OF OPENINGS Notes
SLOPE

1. All dimensions are in milimeter unless otherwise specified.


SLOPE
SLOPE
1:100

OPENING SIZE
1:100

1:100

TYPE (IN MM) DESCRIPTION Nos. 2. Dimensions shall not be scaled, only written dimensions should be followed.
WIDTH HEIGHT 3. Clear cover to all reinforcement bars including stirrups shall be as follows:
D1 900 2100 PVC DOOR (SINTEX OR EQUIVALENT) WITH PVC FRAME 2 Slab - 20mm
VALLEY

VALLEY

VALLEY

Beam - 25mm
D2 750 2100 PVC DOOR (SINTEX OR EQUIVALENT) WITH PVC FRAME 6
4. If any ambiguity found in drawings or at site bring it to designer's notice before
V 600 600 ANODIZED ALUMINUM LOUVERED VENTILATOR TO DETAIL 8 execution.
B1a B1b B1c W1 2000 1200 WOODEN WINDOW WITH FRAME 1 5. All construction activities shall be carriedout under the supervision of site
W2 1200 1200 WOODEN WINDOW WITH FRAME 1 engineer.
STRUCTURAL LAYOUT AT ROOF LEVEL W3 1000 1200 WOODEN WINDOW WITH FRAME 1

OPEN TERRACE
REINFORCEMENT DETAILS
+3.600m Lvl.
3-10T 3-10T THRU. 4-25T 2-16T + 1-12T
3-12 T THRU 3-12T THRU.

BRICK PILLARS BEAM B1 (230X450) B2(230X450) B3(230X450)


TERRACE FLOOR PLAN STIRRUPS - T 8T 8T 10T
SPACE mm c/c 150 150 150
ALL ALL ALL

CLIENT:- EPC CONTRACTOR:- AUTHORITY ENGINEER:- PROOF CONSULTANT: SAFETY CONSULTANT: DESIGN CONSULTANT: PROJECT:- PREPARED S.RAWAT TITLE: DATE:
LEA ASSOCIATES SOUTH ASIA PVT. LTD SABZ INFRA SOLUTION PVT. LTD.
ACCRETE CONSULTING Four Laning Balance work for Mubarikpur TOILET BATHROOM & REST AREA PLAN JUNE,2019
NATIONAL HIGHWAYS ENGINEERS PVT. LTD. DESIGNED D. VINOD
AUTHORITY OF INDIA B-1, E-27, Mohan Cooperative L-15 PRATAP NAGAR NEW Khanna Goyal (Bhopal) to Biaora section of NH-12 from
Industrial Estate DELHI-110007 Designers LLP. NM-8, SONA TOWER, OLD CHECKED UDAY. MAITY SCALE: SHEET: REV:
(MINISTRY OF ROAD TRANSPORT & HIGHWAYS, Mathura Road Mobile:-9212222997 DLF COMM. COMPLEX, Km 324.000 to Km 423.000 in the state of NTS DRG. NO: 1071/BHO-BIA/NH-12/HW/TRUCK/B-03
REV. DATE DESCRIPTION Engr. D/M New Delhi-110044, India e-mail: info@sispl.com GURGAON-122001 Madhya Pradesh on EPC mode under NHAI APPROVED R. SINGHAL 1 OF 1 RO I0
GOVERNMENT OF INDIA) Centrodorstroy (India) Pvt. Ltd. SIZE: A3

S-ar putea să vă placă și