MARELLI ECP DECODE

Hardware Ver. 2
This new interface allows you to decode with IMMO-OFF or Virgin most
Marelli ECU (59F; 5AF; 4AF; 4EF; 5NF - Hardware > 100 and < 100). No
Boot, No Open ECU, No computer use, all in one minute. It is able to recognize
automatically the type of ECU, and to verify the current status through LED.

Support Ecu List:

Magneti Marelli 59F.xx Hw 002


Magneti Marelli 59F.xx Hw 003, 004, 005
Magneti Marelli 59F.xx Hw 023, 024, 025
Magneti Marelli 59F.xx Hw da 100 a 607
Magneti Marelli 5AM e 5AF
Magneti Marelli 4AF.xx Hw 204
Magneti Marelli 4AF.xx Hw 407
Magneti Marelli 4EF.xx Hw 203
Magneti Marelli 5NF.xx Hw 102
Magneti Marelli 5NF.xx Hw 104
Magneti Marelli 6JF.xx Hw 01B, 01C, 1BM only virgin
Magneti Marelli 8/16/18F (bootmode) only hardware Version 2

EcuVonix Solutions - www.ecuvonix.com - support@ecuvonix.com


INSTRUCTIONS
First you need to connect the interface to the ECU via Pin-Out. After connecting, supply power to a battery or
use a stabilized power supply 12 volt (min 1A). Note that the Green Led START flashes indicating the status
of StandBy. The instrument is ready for switching to operating mode.

DECODING
To begin the process of decoding press the ON/OFF button
once (Green LED START);
now the interface queries the ECU and displays by the RED
LED and the LED ORANGE the current code this:

Red and Orange LED ON  The ecu is CODE ON.


Led Orange ON  The ecu is Virgin.
Led Rosso ON -> The ecu is IMMO-OFF.

1) At this point it is selected with the ON/OFF decoding to


be performed, Virgin or IMMO-OFF. Note the Led turns on
Virgin or IMMO-OFF depending on the selection.

2) Immediately after the press DECODE button to start


decoding. During this phase, lasts about one minute, we see
the flashing LED Virgin or IMMO-OFF indicating the start of
decoding.

Just finished the cycle of 1 minute, the interface again


examining the ECU to make sure that the selected decoding
is successful.

Clear DTC error Pin 1 : - 12 Volt (Massa)


Pin 4 : K Line
To begin the process of decoding press the ON/OFF button Pin 3 : L Line
once (Green LED START); Pin 6 : +12 Volt (Key On)
now the interface queries the ECU and displays by the RED Pin 9 : +12 Volt
LED and the LED ORANGE the current code

1) Hold for 2 seconds, the ON / OFF button; interface Clear


the error is present in the back position StandBy.

2) Remove power from the Interface.

WARNING:
In the event that the ECU does not communicate, the interface indicates the error with
the flashing of all LEDs for 3 seconds, returning to the position of StandBy.

EcuVonix Solutions - www.ecuvonix.com - support@ecuvonix.com


Pin Out Iaw 59F.xx / 5AF.xx

Notes for 5AF: Only in case of failure to start, cut the two lines CAN pin n. 20
and n. 29

EcuVonix Solutions - www.ecuvonix.com - support@ecuvonix.com


Pin Out Iaw 4AF.xx / 4EF.xx

EcuVonix Solutions - www.ecuvonix.com - support@ecuvonix.com


Pin Out Iaw 5NF.xx

Connettore M
Pin 5 :-> Massa (Ground)

Connettore V
Pin 16 :-> +12Volt
Pin 12 :-> +12Volt (Key On)
Pin 10 :-> K Line

EcuVonix Solutions - www.ecuvonix.com - support@ecuvonix.com


Pin Out Iaw 6JF.xx (only virgin)

Pin 1 :-> Massa (Ground)


Pin 50 :-> +12Volt
Pin 23 :-> +12Volt (Key On)
Pin 88 :-> K Line

EcuVonix Solutions - www.ecuvonix.com - support@ecuvonix.com


Magneti Marelli 8/16/18F
(bootmode) only Hardware Version 2

To begin the process of decoding connect the ECU to the diagram, and power interface, then press and hold
the "DECODE" button for 3 seconds until Green LED START will flash quickly. Now the interface is in IAW
8/16/18F.

At this point, insert the wire BOOT between pins 2 and 3 of the processor (68HC11F1), then press once the
ON / OFF button immediately after removing the tip of the BOOT;

If everything goes well the RED Led and Orange Led flash rapidly, indicating that the procedure of
decoding. After about 10 seconds interface will return to the initial position (green LED Flashing START).

Led Green with RED and Orange Fixed, Flashing Fast  decoding in progress
Led Green with RED and Orange Fixed, Flashing slowly  BOOT wrong or ECU Not Found
Led Green quickly  Standby mode ECU Iaw 8/16/18F

CAUTION: If for some reason the unit does not communicate, the interface indicates that
error or fault by the simultaneous flashing of all LEDs for 3 seconds and then returns to the
position of StandBy.

Pin 1 : - 12 Volt (Massa)


Pinout 8/16/18F Pin 4 : K Line
Pin 3 : L Line
Pin 34 :-> Ground + Wire BOOT Pin 6 : +12 Volt (Key On)
Pin 35/26 :-> +12Volt (Key On) Pin 9 : +12 Volt
Pin 10 :-> L Line
Pin 15 :-> K Line

EcuVonix Solutions - www.ecuvonix.com - support@ecuvonix.com


EcuVonix Solutions - www.ecuvonix.com - support@ecuvonix.com
EcuVonix Solutions - www.ecuvonix.com - support@ecuvonix.com
EcuVonix Solutions - www.ecuvonix.com - support@ecuvonix.com

S-ar putea să vă placă și