RC3000-16/C6 PCM Multi-Service


Multiplexer
User Manual

Raisecom Technology Co., Ltd


(05/2007)
Raisecom Technology Co., Ltd

General Safety Instructions

The following instructions serve as a general guide for the safe installation and operation of
telecommunications products. Additional instructions, if applicable, are included inside the
manual.

Safety Symbols

This symbol may appear on the equipment or in the text. It indicates potential
safety hazards regarding product operation or maintenance to operator or service
personnel.

Danger of electric shock! Avoid any contact with the marked surface while the
product is energized or connected to outdoor telecommunication lines.

Protective earth: the marked lug or terminal should be connected to the building
protective earth bus.

Some products may be equipped with a laser diode. In such cases, a label with the laser class
and other warnings as applicable will be attached near the optical transmitter.
The laser warning symbol may be also attached.
Please observe the following precautions:
• Before turning on the chassis with optic module, make sure that the fiber optic
cable is intact and is connected to the transmitter.
• Do not attempt to adjust the laser drive current.
• Do not use broken or unterminated fiber-optic cables/connectors or look
straight at the laser beam.
• The use of optical devices with the equipment will increase eye hazard.
• Use of controls, adjustments or performing procedures other than those specified herein, may
result in hazardous radiation exposure.
ATTENTION: The laser beam may be invisible!

Always observe standard safety precautions during installation, operation and maintenance of this
product. Only qualified and authorized service personnel should carry out adjustment,
maintenance or repairs to this product. No installation, adjustment, maintenance or repairs should
be performed by either the operator or the user.

1
Raisecom Technology Co., Ltd

All extension slots are not hot-swappable

Before operating modules in the electricity conditions, please be noticed that optical modules shall
be connected with optical fiber wires or shield with optical module cover for fear that laser light
harms to operator’s eyes.

Handling Energized Products

General Safety Practices

Do not touch or tamper with the power supply when the power cord is connected. Line voltages
may be present inside certain products even when the power switch (if installed) is in the OFF
position or a fuse is blown. For DC-powered products, although the voltages levels are usually not
hazardous, energy hazards may still exist.
Before working on equipment connected to power lines or telecommunication lines, remove
jewelry or any other metallic object that may come into contact with energized parts.
Unless otherwise specified, all products are intended to be grounded during normal use.
Grounding is provided by connecting the mains plug to a wall socket with a protective earth
terminal. If an earth lug is provided on the product, it should be connected to the protective earth
at all times, by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be
mounted only in earthed racks and cabinets.
Always make the ground connection first and disconnect it last. Do not connect
telecommunication cables to ungrounded equipment. Make sure that all other cables are
disconnected before disconnecting the ground.

Connection of AC Mains

Make sure that the electrical installation complies with local codes.
Always connect the AC plug to a wall socket with a protective ground.
Always connect the power cord first to the equipment and then to the wall socket. If a power
switch is provided in the equipment, set it to the OFF position. If the power cord cannot be readily
disconnected in case of emergency, make sure that a readily accessible circuit breaker or
emergency switch is installed in the building installation.

Connection of DC Mains

Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to
the ground. Any single pole can be externally grounded.
Due to the high current capability of DC mains systems, care should be taken when connecting the
DC supply to avoid short-circuits and fire hazards.
DC units should be installed in a restricted access area, i.e. an area where access is authorized only

2
Raisecom Technology Co., Ltd

to qualified service and maintenance personnel.


Make sure that the DC supply is electrically isolated from any AC source and that the installation
complies with the local codes.
Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate
the circuit breaker of the panel board that services the equipment and switch it to the OFF position.
When connecting the DC supply wires, first connect the ground wire to the corresponding terminal,
then the positive pole and last the negative pole. Switch the circuit breaker back to the ON
position.
A readily accessible disconnect device that is suitably rated and approved should be incorporated
in the building installation.

Preventing Electrostatic Discharge Damage

Modules which can be plugged into chassis are sensitive to damage from static electricity.
Conversely, static voltages as high as 35,000V can be generated just by handling plastic or foam
packing material, or by sliding assemblies across plastic and carpets. Not exercising the proper
electrostatic discharge (ESD) precautions can result in intermittent or complete component failures.
To minimize the potential for ESD damage, observe the following guidelines:
• Always use an ESD-preventive antistatic wrist strap or ankle strap and ensure that it makes good
skin contact.
• When removing or installing a component, make sure the equipment end of your antistatic strap
leash is connected to the ESD connection sockets on the front of the chassis or to a bare metal
surface on the chassis. Avoid contact between the component and your clothing. The wrist strap
only protects the component from ESD voltages on the body; ESD voltages on your clothing can
still cause component damage.
• Always place a card component-side-up on an antistatic surface, in an antistatic card rack, or in a
static shielding bag. If you are returning the item to the factory, immediately place it in a static
shielding bag.
• Handle Modules by the metal card carrier edges only; Avoid touching the board or any connector
pins.

3
Raisecom Technology Co., Ltd

Contents

1. Overview............................................................................................................. 1
1.1. Introduction .............................................................................................. 1
1.2. Main features: .......................................................................................... 1
1.3. Function ................................................................................................... 2
1.4. Module Configure..................................................................................... 2
1.5. Typical Application.................................................................................... 2
1.6. NETWORK CONSTRUCTION ................................................................. 3
1.6.1. Traditional Point to Point application ............................................... 3
1.6.2. The point-to-multipoint application .................................................. 4
1.7. Main Technical Performance .................................................................... 5
2. Equipment Introduce........................................................................................... 8
2.1. Equipment model ..................................................................................... 8
2.2. Power Supply Board ................................................................................ 8
2.3. Master Control Board (RC3000-SUB-MCU)........................................... 10
2.3.1. E1 interface: ................................................................................11
2.3.2. Ethernet monitor: .........................................................................11
2.3.3. Pilot Lamp: .................................................................................... 12
2.3.4. Switch setting: ............................................................................... 12
2.4. Network Monitor Card (RC3000-MB-NMC) ............................................ 15
2.5. E1 Port Spool (RC3000-SUB-E1)........................................................... 15
2.5.1. E1 interface: .................................................................................. 16
2.5.2. E1 port setting: ........................................................................... 16
2.5.3. Pilot Lamp:.................................................................................. 18
2.6. Voice Channel Spool (RC3000-SUB-CHU) ............................................ 18
2.6.1. Type:........................................................................................... 19
2.6.2. Application: ................................................................................. 20
2.6.3. Function:..................................................................................... 20
2.6.4. Direction for Use:........................................................................ 22
2.7. Data Spool(RC3000-SUB-DATA)....................................................... 25
2.7.1. Data Panel .................................................................................... 25
2.7.2. RS232/485 Data Interface Card (RC3000-MB-232/485) ............... 30
2.7.3. V.35 Synchronous Data Interface Card (RC3000-MB-V35) .......... 31
2.7.4. 10BASE-T Ethernet Interface Card(RC3000-MB-ETH)................. 31
3. CABLE.............................................................................................................. 33
3.1. RC3000-SUB-MCU 2M cable(120Ω)................................................ 33
3.2. RC3000-SUB-E1 spool 2M outline cable ............................................... 34
3.3. VF Cable ................................................................................................ 35
3.4. E/M Cable .............................................................................................. 36
3.5. 10BASE-T Cable.................................................................................... 37
3.6. RS232/485 data cable............................................................................ 38
3.7. V35 data cable ....................................................................................... 39

4
Raisecom Technology Co., Ltd

3.8. V35 and 10BASET data cable................................................................ 41


3.9. RS232/485 monitor cable....................................................................... 42
3.10. -48v Power cable................................................................................ 42

5
Raisecom Technology Co., Ltd

1. Overview

1.1. Introduction

Raisecom’s RC3000-16/C6 PCM multi-service multiplexer, whose kernel is powerful


cross matrix, is integrated with the functions of digit/analogue access、diplex、cross、
transmission and protocol conversion. Building on normalized structure and combining
with the style of access network service, it composes a unified platform of BX series
equipments. It is plug and play, and can optionally group each functional module. Based
on the platform of public power supply, network management, cross and motherboard, it
constructs the mixed function Equipment of DXC/PCM/10&100 optical fiber transceiver
and modular, and frames the network which is integrated active and passive, broadband
and narrowband, and transmission and access.
RC3000-16/C6 PCM multi-service multiplexer’s SNMP centralized monitoring network
management function can actualize the real-time monitoring to the whole network’s
correspondence states.

1.2. Main features:

¾ Integrated with digit/analogue access, diplex, cross, transmission and protocol


conversion functions.
¾ RC3000-16 : universal 16 slot and 4U high system chassis; RC3000-C6 : universal 6
slot and 2U high system chassis.
¾ Plenty of interfaces:POTS、10Base T V.35、RS232、RS485 and so on.
¾ Can be configured flexibly. The slot can be mixed plugged,and the interface card can
be matched arbitrarily.
¾ Support hot plug and pull.
¾ Power supply warm standby.
¾ Optimistic bus,user interface is abundant,and is too apt to append new style service.
¾ Network grouping flexible:point-to-point, linear drop/insert, arborescence, star and
ring admixture modes of network grouping.
¾ Intelligent network administration system : humanization supervise, exact fault
location ,distributivity supervise, and so on.

1
Raisecom Technology Co., Ltd

¾ 64×E1full cross,support CAS signaling cross.

1.3. Function

¾ Voice access,manifold signaling interfaces:


Automatic telephone, E/M interface, and 2/4 strung audio frequency etc.
¾ Data access,multiple data interfaces:
10Base-T,v.35,RS232 / 485 etc.
¾ 4×E1 interfaces,
¾ Cross joint functions,E1 interface flashboard structure:
64×E1 full cross,support CAS signaling cross.
¾ Ethernet over E1 and V35 to E1 converter
¾ Centralized network management:
¾ Full net monitor,support SNMP protocol.

1.4. Module Configure

¾ Master control spool supplies four E1 interfaces,which can select Ethernet monitor
card to realize full net monitor.
¾ 2 telephone channels is one configuration unit, and there are most 8 channels on one
panel. The full configuration of RC300-16 is 104 channels, and RC3000-C6 is 40
channels.
¾ One data channel(10/100 Base-T,V.35)is one configuration unit,and there are most
4 channels on one spool. The full configuration of RC300-16 is 52 channels, and
RC3000-C6 is 20 channels.
¾ 2 RS232(485)data channels is one configuration unit,and there are most 104
channels in one spool.
¾ E1 interface,8 channels one spool. For 4U aircraft type, there are most 40 channels,
which can realize 64xE1 time slot full cross function and support signaling cross.

1.5. Typical Application

¾ Metropolitan area network (MAN) construction


¾ Integrated services access for big user

2
Raisecom Technology Co., Ltd

¾ The network construction of uniting three network


¾ Intellectualized sub zone construction
¾ DDN network extending
¾ Mobile base station construction
¾ Expanding telecommunication service in existed CATV network for Broadcast and
Televise Department
¾ Wiring network layer construction for the access net
¾ Telecommunication agriculture net rebuilding
¾ Replacing macro PDH and middle or low capacity SDH optical transmission
equipments
¾ Emergency communication
¾ Military normalization network construction.

1.6. NETWORK CONSTRUCTION

1.6.1. Traditional Point to Point application

Fig 2-1 the point-to-point method to construct the RC3000-C6 network

3
Raisecom Technology Co., Ltd

1.6.2. The point-to-multipoint application

Fig 2-2 the point-to-multipoint method to construct the RC3000-16&C6 network

4
Raisecom Technology Co., Ltd

1.7. Main Technical Performance

Encode A-law
Bit rate 64Kbit/s
maximum impedance
2000Ω
of DC circuit
Effective transmission
300-3400Hz/600Ω
bandwidth
Frequency character:
POTS remote 300Hz—400Hz -0.3~-0.1 dB
user lines 400Hz—2400Hz -0.2~0.1 dB
2400Hz—3400Hz 0~0.7 dB
Imbalance degree to
the ground:
300Hz—600Hz 40 dB
600Hz—3400Hz 46 dB
Idle channel noise <-67dB
Ring current voltage 25±3Hz,AC75±15V
Encode A-law
Bit rate 64Kbit/s
Maximum impedance
2000Ω
of DC circuit
Effective transmission
300-3400Hz/600Ω
bandwidth
Frequency character:
POTS local
300Hz——400Hz -0.3~-0.1 dB
User lines
400Hz——2400Hz -0.2~0.1 dB
2400Hz——3400Hz 0~0.7 dB
Imbalance degree to
the ground:
300Hz——600Hz 40 dB
600Hz——3400Hz 46 dB
Idle channel noise <-67dB
Interface code HDB3
Standard bit rate and
2048Kb/s±50ppm
tolerance
E1 interface Standard waveform
2.37V±0.237V/75Ω(imbalanced)
range
attenuation range is 0-6dB at
Intervene loss:
1024KHz

5
Raisecom Technology Co., Ltd

Total distortion Conform to ITU-T G.713


Frequency feature Conform to ITU-T G.713
Level feature Conform to ITU-T G.713
Available band width
300~3400 Hz/600Ω
for transmission
Voice transmission
2 wire or 4 wire
mode
Two- wire 0dBr/600 Ω ( -14dBm ~
Voice interface transmission +17.5dBm,adjustable)
-3.5dBr/600Ω(-31.5dBm~0dBm,
Two- wire reception
adjustable)
Four- wire -14dBr/600Ω(-14dBm~
transmission +17.5dBm, adjustable)
+4dBr/600Ω(-27.5dBm~+4dBm,
Four- wire reception
adjustable)
Step to adjust power 0.5dBm
Overloaded power +3.14dBm
Connected to ground 20Ω±10%
Inner impedance:
Open circuit 100KΩ
Sampling frequency 500Hz
Pulse distortion ≤2.5ms
E&M interface
Clock frequency 500Hz 8KHz
electronic
Sampling rate 500Hz
parameter
Pulse distortion ≤2.5ms
Clock frequency 500Hz 8KHz
Open circuit: “1”
Encode principle
Connected to the ground: “0”
Asynchronous low 600,1200,2400,4800,9600,19200bi
speed data interface t/s
Identical-direction 64Kb/s (coincide with suggestion
interface ITU-T G.703)
Data interface
N×64k Two channel N×64K data channel
provided by each board
interface type V.35/10Base-T
maximum rate N=30
System capacity 4E1
Optical Transmitted
-5~-12dBm
4E1 optical Power
module Fiber optic connector
FC
type
Input impedance 75/120Ω

6
Raisecom Technology Co., Ltd

Signaling The 16th slot CAS with suggestion


Signaling pattern
interface ITU-T G.732
Power
Power supply 48V(±10%)/220VAC
supply
Standard 19 inch,
Box
RC3000-16:height 4U, 16 slots
structure
RC3000-C6:height 2U, 6 slots
temperature: 5~50℃
Working
humidity: ≤90%(35℃)
surroundings
Air pressure: 86-106KPa

7
Raisecom Technology Co., Ltd

2. Equipment Introduce

2.1. Equipment model

Multi types of flashboard structure and model of airplane can be selected. It is


compatible with 4U, 2Uboard level board system , and can be capacity-expansion
conveniently.
(1)、4U model (RC3000-16):
PWR MCUS CHUPS DATA CHUPS DATA E10PS E10PS E10PS E10PS CHUPS DATA CHUPS DATA E1PS PWR

NET RUN
48V RUN
1 TD1 1 TD1 PWR PWR PWR PWR 1 TD1 1 TD1 PWR
48V
LINK FLA1
MRUN 2 RD1 2 RD1 TXD TXD TXD TXD 2 RD1 2 RD1 RLS1
TEST FLA2
+5V MA
3 TD2 3 TD2 RXD RXD RXD RXD 3 TD2 3 TD2 RLS2 +5V
FLA1 FLA3
RLS1 4 RD2 4 RD2 LINK LINK LINK LINK 4 RD2 4 RD2 RLS3
FLA2 FLA4
-5V RLS2
5 TD3 5 TD3 ERR ERR ERR ERR 5 TD3 5 TD3 RLS4 -5V
FLA3 FLA5
RLS3 6 RD3 6 RD3 RLS RLS RLS RLS 6 RD3 6 RD3 RLS5
FLA4 FLA6
RING RLS4
7 TD4 7 TD4 FLA FLA FLA FLA 7 TD4 7 TD4 RLS6
RING
FLA7
8 RD4 8 RD4 AIS AIS AIS AIS 8 RD4 8 RD4 RLS7
FLA8
RA RA RA RA RLS8

MONITOR

The height of 4U is 19 inch, and the width is 300mm.


It is suitable for office end,sixteen slots,fourteen of that are function spools and can
be mixed planting at will. Power supply spool owns two slots. They are warm standby
for each other.
(2)、2U model ( RC3000-C6):

The height of 2U is 19 inch, and the width is 300mm.


It is suitable for remote end,which owns six slots. The power supply spool does not
occupy slot,and there is no hot backup function.

2.2. Power Supply Board

(1)、RC3000-16 4U Power Supply Board

8
Raisecom Technology Co., Ltd

Apply for 4U engine case, in which most 2 power supply Board can be planted, and
they are warm standby for each other.。
On the front panel there is power light,which indicates different kinds of power supply
working status.

PWR

48V

+5V

-5V

RING

a.4U No ringing current power supply Board(RC3000-SUB-4UPWR)


Input:DC –36 ~ – 72V。
Function:DC/DC power supply changeover,supplying system Operational Power
Supply.
Output:+5v, -5v,-48v power feed.
b. b.4URemote end power supply Board(RC3000-SUB-4ULPWR)
input:DC –36 ~ – 72V。
Function:DC/DC power supply changeover,DC–48V switch to AC 75Vringing
current,supplying system Operational Power Supply with from.
Output:+5v,-5v, ringing current,-48v power feed.
(2)、RC3000-C6 2U Power Supply Board:
Apply for 2U engine case, in which most 1 power supply Board can be planted, and

9
Raisecom Technology Co., Ltd

they are warm standby for each other.。

48V
+5V
-5V
RING

ON

OFF

2U No ringing current power supply Board(RC3000-SUB-2UPWR)


input:DC –36 ~ – 72V;AC 220V。
Function:DC/DC power supply changeover,supplying system Operational Power
Supply.
Output:+5v, -5v, -48v power feed.
2U remote end power supply Board(RC3000-SUB-2ULPWR)
input:DC –36 ~ – 72V。、AC 220V。
Function:DC/DC power supply changeover,DC–48V switch to AC 75Vringing
current,supplying system operational power supply.
Output:+5v,-5v, ringing current,-48v power feed.

2.3. Master Control Board (RC3000-SUB-MCU)

Functional Description:
System control centre, preside monitor and resource allocation..
Comprise GSI,inter-construct 2048 X 2048 cross matrix,which can realize 64 E1
time slot cross at will.
System automatically performs real time self-checking and reports the malfunction to
the leadership,which makes it convenient for fault location.
Configuring with network monitor card,it can offer full net monitor,monitoring

10
Raisecom Technology Co., Ltd

gateway time slot and optional alternate bit.


Built-in four E1 interfaces.

Functional interface:

Indication E1 Interface
Lamp
NMC SLOT

Address E1 SET
Switch

Side Swich Rs485 Monitor

Resistance InterfaceⅡ
Monitor
InterfaceⅠ
Reset

Master control panel layout diagram

2.3.1. E1 interface:

¾ Position:(J1)DB37 cellular type socket.


¾ Interface posture: equilibrium-> DB37cellular type socket,
non-equilibrium-> CC4A coaxial socket
¾ Endue 4×E1 interface, coil out table see "appendices:4×E1 coil out table".
¾ Support equilibrium and non-equilibrium modes.
¾ Support manifold signaling modes:
CAS:by CAS mode, subscriber signaling executive cross automatically.
CCS:in CCS mode, TS16 time slot can be used for transmitting subscriber
service.
¾ Support CRC-4 checkout.
¾ Provide monitor pathway:time slot and alternate bit is optional.
¾ Monitor Interface:
¾ Position:(J4)DB9 cellular type socket,,RS232/485 monitor. (J5)RJ45
socket,

2.3.2. Ethernet monitor:

¾ Position:(J4)DB9 cellular type socket,,RS232/485 monitor. (J5)RJ45


socket,

11
Raisecom Technology Co., Ltd

¾ Different kinds of monitor port coil out table see "appendices:monitor port coil
out table"
¾ RS232 monitoring transmission velocity is 9600bps. Transmission range is 15m.
¾ RS485 monitoring transmission velocity is 9600bps. Transmission range is
800m.
¾ Ethernet monitoring transmission velocity is 10/100Mbps, transmission range is
100m.

2.3.3. Pilot Lamp:

MCUS
NET
RUN
LINK
MRUN
TEST
MA
FLA1
RLS1
FLA2
RLS2
FLA3
RLS3
FLA4
RLS4

MONITOR

2.3.4. Switch setting:

(1)Reset button:
Position:S21.
Function:when depressed reset CPU.

12
Raisecom Technology Co., Ltd

(2)Program Switch:

Position: S20.
Function: Program selector switch.
Fixed setting short circuit pip approach S20 aside
(3)side unplug switch:
Position:JP5。
SW1 OFF ON ON OFF
OFF OFF ON ON
LED alarm indicator
SW2
RLS AIS MFLA CMFLA
FLA RA MRA CMA
RS232 monitor RS485 monitor
SW3
ON OFF
SW4 reserved
Indicator signification table:
Indicator Signification
On: network monitor card configured; Off: network monitor card
NET
not configured
RUN Flash: MCUS functions; Not flash: MCUS malfunctions
On: network monitor card line connected; Off: network monitor
LINK
card line not connected (configuration not working)
Flash: network monitor card functions; Not flash: network
MRUN
monitor card malfunctions (configuration not working)
TEST reserved
MA reserved
RLS1-4 On: 2M signal receive loss; Off: 2M signal received
On: 2M signal frame receive loss; Off: 2M signal frame
FLA1-4
received
AIS1-4 On: 2M signal receive all “1”; Off: 2M signal received
On: remote 2M signal receive alarm; Off: remote 2M signal
RA1-4
received
On: 2M signal multi-frame receive loss; Off: 2M signal
MFLA1-4
multi-frame received

13
Raisecom Technology Co., Ltd

On: remote 2M signal multi-frame receive loss; Off: remote 2M


MRA1-4
signal multi-frame received
On: 2M signal CRC4 multi-frame receive loss; Off: 2M signal
CMFLA1-4
CRC4 multi-frame received
On: remote 2M signal CRC4 multi-frame receive loss; Off:
CMRA1-4
remote 2M signal CRC4 multi-frame received
Notes: 1-4 stand for 4 2M number on rear panel; in standard configuration, only
RLS1,FLA1 of No. 1 E1 configured, while the rest reserved. Other alarms can be
observed by code switch (SW)

(4)Address switch:

(* Notice: MCUN spool JP1,JP2 switches diagram)


Position: JP1, JP2 tip pull switch
Function:JP1 is the network address setting,and JP2 is the unit address setting.
ON is '1',OFF is '0'.
(5)RS485 resistance::

position:S16、S17、S18、S19 .
Function:Y side cutover with RS485 matched resistance,N side does not cutover
matched load resistance..
(6)E1 interface setting:
A、balance mode setting:

14
Raisecom Technology Co., Ltd

S5-S12,Inlaying grafting short circuit pip is non-equilibrium mode, others is interface


mode.
B、interface impedance setting:

S1-S4,Silk-screen 75 aside is 75 OHM,silk-screen 120 aside is 120 OHM.

2.4. Network Monitor Card (RC3000-MB-NMC)

Functional description:
¾ Execute the monitor intercommunication between BX10 equipments ,realize full
net monitor(be compatible with equipments such as BX06).
¾ If MCUS master control panel does not be configured this card,it wouldn't be
managed by other network equipment through network, and can only be
monitored locally.
¾ Support Ethernet, RS232, RS485monitor.。
¾ Support SNMP protocol.

2.5. E1 Port Spool (RC3000-SUB-E1)

Functional description:
¾ Per spool endues eight channels. Configure most eight spools sixty-four
channels for 4u model of airplane,and realize 64xE1 time slot full cross function.
Configure most five spools forty-four channels for 2U model of airplane,
(master
control panel can provide four channels).
¾ E1 interface support CAS and CCS signaling mode.

15
Raisecom Technology Co., Ltd

¾ E1 interface support balance and non-balance modes。


Functional interface:

Indication E1
lamp Interface

Side
Swtich

Reset

2.5.1. E1 interface:

¾ Position:(J5)DB62 cellular type socket.

¾ Interface type: balance -> DB62 cellular type socket,non-balance-> CC4A coaxial

socket

¾ Endue 8xE1 ports, coil out table see "appendices:8xE1 coil out table".

¾ Support equilibrium and non-equilibrium modes.

¾ Support manifold signaling modes:

CAS:by CAS mode, subscriber signaling executive cross automatically.

CCS:in CCS mode, TS16 time slot can be used for transmitting subscriber

service.

¾ Support CRC-4 checkout.

¾ Provide monitor pathway,time slot, alternate bit is optional.

2.5.2. E1 port setting:

A、balance mode setting:

16
Raisecom Technology Co., Ltd

S4-S19 ,N side inlaying grafting short circuit pip is non-equilibrium mode,Y side

inlaying grafting short circuit pip is equilibrium mode.

B、interface impedance setting:

S20-23,S24-s27,silk-screen 75 aside is 75OHM,and silk-screen 120 aside

is 120 OHM.。

17
Raisecom Technology Co., Ltd

2.5.3. Pilot Lamp:

E1PS
RUN
PWR
FLA1
RLS1
FLA2
RLS2
FLA3
RLS3
FLA4
RLS4
FLA5
RLS5
FLA6
RLS6
FLA7
RLS7
FLA8
RLS8

2.6. Voice Channel Spool (RC3000-SUB-CHU)

All kinds of voice service submitted by BX10 combined service platform are

accomplished by voice channel spool and the service mouthpiece card corresponding to

the submitted service altogether. Voice channel spool is primarily responsible for the

data receive and dispatch, dispose and the configuration of network management

information. The miscellaneous service mouthpiece card provides the port with voice

service equipment (such as substation, magnet telephone and exchanger). Service

mouthpiece card changes real line signaling and speech signal transmitted from different

18
Raisecom Technology Co., Ltd

equipments into digital signal and transmits them to voice channel spool. Voice channel

spool tackles this signal and then transmits them to the opposite terminal, and complete

the handshaking procedure of call and sound transmission. According to different

services provided, service mouthpiece card can be divided into two/four wire speech path

interface, automatic telephone mouthpiece and E&M mouthpiece there types.

The panel Pilot Lamp shown in the following chart:

CHUPS

1
2
3
4
5
6
7
8

Every spool provides 8 channels integrated access of voice service..

2.6.1. Type:

— Voice channel spool (RC3000-SUB-CHU)

— Two/four wire adjustable attenuation voice channel card (RC3000-MB-2W4W)

— Automatism station set office end signaling card (RC3000-MB-FXO).

— Automatism station set remote end signaling card (RC3000-MB-FXS).

19
Raisecom Technology Co., Ltd

— E&M signaling card (RC3000-MB-EM).

2.6.2. Application:

Voice channel spool:Voice channel service function spool, provides miscellaneous

service when plugged in card. Most eight channels voice channel can be supported.

Two/four wire adjustable attenuation voice channel card:Every card provides two

channels two/four wire adjustable attenuation voice channel and provides independent

voice frequency channel.

Automatism station set signaling card : designed to provide normal telephone

mouthpiece. The side jointed with exchanger adopts office end card, and the side jointed

with customer set adopts remote end card. Every card provides two channels two wire

fixed extinctive voice channels which transmit automatic office end (remote end) signaling.

E & M signaling card: designed to provide the first to fifth type E/M signaling

mouthpiece of 1E1M to 2E2M, and provide one channel two/ four wire adjustable

attenuation voice channel at the same time.

2.6.3. Function:

Voice Channel Spool(RC3000-SUB-CHU)

¾ Communicate with network management, configure service function.

¾ Communicate with bus, proceed data transmission.

¾ Dispose the voice information and signaling information.

¾ Supply power for each service card, proceed data exchange, and provide

miscellaneous service mouthpiece coil out.

Two/Four Wire Adjustable Attenuation Voice Channel Card(RC3000-MB-2W4W)

¾ Realize the transition between the digital signal( A-law.PCM) and the analog speech

signal.

¾ Provide two voice frequency channels or two no signaling two/four wire analogy

private line mouthpiece gateway.

¾ The two/four wire switch of every voice frequency channel can be set independently.

20
Raisecom Technology Co., Ltd

¾ By the control of loop back signal, realize all voice frequency channel loop back.

¾ Be possessed of wire protect function, which can prevent the interface from the

damage causing by thunderbolt or the clash between service line with other electric

line of force.

¾ By slip stitch switch, one can adjust the receive side and transmit side transmission

level of two/four wire respectively

Automatism Station Set Office End Signaling Card(RC3000-MB-FXO)

¾ Provide two channels two wire telephone with automatic station set office end

signaling.

¾ Equivalent to common analog station set, recover the remote end rolling off signal.

¾ Recover remote end dial impulse.

¾ Detection the ringing signal coming from the exchange service line, and change it into

digital signaling and supply it for master control panel(MCUS)

¾ Provide the display of the information of passage occupancy.

¾ Provide "Incoming Telegram Display " function.

Automatism Station Set Remote End Signaling Card(RC3000-MB-FXS)

¾ Provide two channels two-wire telephone with automatic station set remote end

signaling.

¾ Be equivalent to the exchange subscriber module, provide station set feeding and

ringing current.

¾ Detection the signal such as rolling off and impulse dialing coming from service line,

and change it into digital signaling and supply it for master control panel

(RC3000-SUB-MCU).

¾ Indicate the working status of user port.

¾ Biggest permitted loop resistance is 2000Ω.

E&M Line Signaling Card(RC3000-MB-EM)

¾ Complete the transition from E-line and M-line signaling to digital signaling, and

transmit the digital signaling to master control panel (RC3000-SUB-MCU).

¾ Provide 1 E&M signaling port from 1E1M to 2E2M.

21
Raisecom Technology Co., Ltd

¾ Provide 1 two/four wire adjustable attenuation voice channel.

¾ Each port can be configured to type Ⅰ、Ⅱ、Ⅲ、Ⅳ and V E&M port.

¾ Provide the indication of port status.

2.6.4. Direction for Use:

In order to supply voice service, the voice channel spool should be combined with

corresponding service mouthpiece card, the direction for use describes them separately

according to service mouthpiece card.

Voice Channel Spool(RC3000-SUB-CHU)

On voice channel spool front panel there are nine pilot lamp,defined as follows:

Two/four wire adjustable attenuation voice channel card(RC3000-MB-2W4W)

¾ Two/four wire voice frequency channel setting switch

‹ Set passage work in two wire or four wire mode.

¾ Voice frequency channel transmit/receive relative level setting switch

Used for two/four wire adjustable attenuation voice channel panel. One can set the

transmit receive relative level of voice frequency channel respectively, whose regulating

range is 0.5- 31.5dB and regulating step is 0.5dB.

The function set switch position above shown on the figures as follows:

Two/four wire mode selector switch

Changing the position of corresponding mode conversion switch, one can set the

operate mode be two or four wire operate mode as shown in the following figure.

Relative level setting switch

There are total two groups and twenty-four pin jumpers used for regulate outgoing

level and incoming level which can be divided into transmission level setting switch and

receiving level setting switch. The adjusting step is 0.5dB.

Attenuator is made up of six segment resistance network, and the attenuation

quantity of each segment is 0.5db, 1db, 2db, 4db, 8db and 16db. Every segment

corresponds to two column thrusting needles. For example, needles are inserted in the left

column; it means that the attenuator in this segment is switched on. The sum of

22
Raisecom Technology Co., Ltd

attenuation quantity of each segment's attenuator is the attenuation quantity of the wholly

attenuator.

The setting of two/four wire adjustable voice channel panel is two wire modes in

general, whose transmission level is 0dbr and receiving level is -3.5dbr. If it is needed to

turn to four wire mode or regulate the relative level of mouthpiece point, one can modify

the corresponding voice channel setting according to the explanation as follows.

Automatism Station Set Office End Signaling Card(RC3000-MB-FXO)

For the received and transmitting direction of the fixed attenuation voice channel

spool provided by automatism station set office end signaling card, there are also set with

level setting switches. Switches arrange vertically. There are four slip stitch, which is

divided into four groups. The upper group is transmitting direction regulating switch and

the nether group is receiving direction regulating switch. By the regulating switch one

can increase 4dB attenuation in corresponding direction.

Panel pilot lamp provide the indication of passage occupancy information.

Automatism Station Set Remote End Signaling Card(RC3000-MB-FXS)

Both the receive and transmit direction of the fixed attenuation voice channel spool

provided by automatism station set remote end signaling card are also configured with

level setting switch. arrange vertically. There are four slip stitch, which is divided into four

groups. The upper group is transmitting direction regulating switch and the nether group is

receiving direction regulating switch. By the regulating switch, one can increase 4dB

attenuation in corresponding direction.

Panel pilot lamp provide the indication of passage occupancy information.

E&M Line Signaling Card(RC3000-MB-EM)

The panel pilot lamp is the same as the signaling card of automatism station set office

end (remote end).

E/M line signaling card uses slip stitch to determine which type of five types E/M is

adopted.

E&M line signaling panel global layout sketch map

The setting means of E&M interface board

Let 1E1M be an example, there is the way of simplex setting of the E/M signaling card in

23
Raisecom Technology Co., Ltd

the following text. It is absolutely same with office end and remote end. The setting of

2E2M is the like.

A. Setting as the first kind EM:Planting short circuit pip in S3. S4, S6, S7 and S8 do

not be planted. The two slip stitch below SW1 are planted short circuit pip. The E-line

and M-line of this spool are connected with E-line and M-line of the exchanger. When

connecting with subscriber equipments, E is connected with M and M is connected with E.

SB and SG wires are connected with each other directly.

B. Setting as the second kind EM:planting short circuit pip in S7. S3,S4, S6, and S8 do

not be planted. The two slip stitch below SW1 are planted short circuit pip. The E-line

and M-line of this spool are connected with E-line and M-line of the exchanger, and SG

and SB wires are connected with the SG and SB wires of exchanger directly . When

connecting with subscriber equipments, E is connected with M and M is connected with E.

SB and SG wires are connected with each other directly. See the right figure:

C. Setting as the third kind EM:Planting short circuit pip in S7 and S3. S4, S6, and S8

do not be planted. The two slip stitch below SW1 are planted short circuit pip. The E-line

and M-line of this spool are connected with E-line and M-line of the exchanger, and SG

and SB wires are connected with the SG and SB wires of exchanger directly. When

connecting with subscriber equipments, E is connected with M and M is connected with E.

SB and SG wires are connected with each other directly. See the right figure:

D. Setting as the fourth kind EM:planting short circuit pip in S6. S3, S4, S7, and S8

do not be planted. The two slip stitch on the top of SW1 are planted short circuit pip. The

E-line and M-line of this spool are connected with E-line and M-line of the exchanger, and

SG and SB wires are connected with the SG and SB wires of exchanger directly . When

connecting with subscriber equipments, E is connected with M and M is connected with E.

SB and SG wires are connected with each other directly. See the right figure:

E. Setting as the fifth kind EM:Planting short circuit pip in S6. S3, S4, S7, and S8 do

not be planted. The two slip stitch on the top of SW1 are planted short circuit pip. The

E-line and M-line of this spool are connected with E-line and M-line of the exchanger, and

SG and SB wires are connected with the SG and SB wires of exchanger directly. When

connecting with subscriber equipments, E is connected with M and M is connected with E.

24
Raisecom Technology Co., Ltd

SB and SG wires are connected with each other directly. See the right figure:

Notice:

When setting E/M be one type,one must be set according to the forementioned means

strictly and double check please. If the short circuit pip is connected in wrong way, the

spool may be burnt! Strictly prohibit hot plugging E/M signaling spool.

2.7. Data Spool(RC3000-SUB-DATA)

Sort:data Panel, 10BASE-T Ethernet interface card,

RS232/485 data interface card, V.35 synchrodata interface card.

2.7.1. Data Panel

2.7.1.1. Functional Description:

1. There are four plug in card slots on each spool, where V.35 data interface card、

10BASE-T Ethernet interface card and RS232/485 data interface card can be

implanted.

2. Data spool provides no interface by itself. At implanting interface card, the

available interface provided by data spool is decided by the type of card. For

example, if V.35 data interface card is implanted, the data spool can provide V.35

interface. If RS232/485 data interface card is implanted, the data spool can

provide RS232/485 interface. If 10BASE-T interface card is implanted, the data

spool can provide 10BASE-T Ethernet interface. The above three types card can

also be implanted on one data interface spools. Data spool can provide most

four V.35 interfaces, four 10BASE-T interfaces and eight RS232/485 interfaces.

3. Both V.35 data interface and 10BASE-T Ethernet interface can be set as N×64k

( n = 1~31) dynamic situation data gateway. RS232/485 data interface can be

set as 64k data channel.

25
Raisecom Technology Co., Ltd

2.7.1.2. Functional interface:

Indication
Lamp CARD 1 CARD 2 Data
Interfaces

CARD 3 CARD 4

Note: If place a DB26 to RJ45 transfer head in V.35 or RS232 or RS485 interface,

then the data spool can offer 10Base-T interface.

26
Raisecom Technology Co., Ltd

Pilot Lamp Illustration


1. Implant V.35 synchronous data interface card in the data interface spool
Flickering Program runs normally
RUN Program Run Pilot Lamp
Went out Program runs abnormally
The first channel is
The first channel data Flickering
RXD1 receiving data
receiving indication
Going out Free
The first channel is
The first channel data Flickeringr
L/D1 transmitting data .
transmitting indication
Going out Free
The second channel is
Second channel data Flickering
RXD2 receiving data
receiving indication
Going out Free
The second channel is
The second channel data Flickering
L/D2 transmitting data
transmitting indication
Going out Free
The third channel is
The third channel data Flickering
RXD3 receiving data
receiving indication
Going out free

27
Raisecom Technology Co., Ltd

The third channel is


The third channel data Flickering
L/D3 transmitting data
transmitting indication
Going out Free
The fourth channel is
The fourth channel data Flickering
RXD4 receiving data
receiving indication
Went out Free
The fourth channel is
The fourth channel data Flickering
L/D4 transmitting data
transmitting indication
Going out Free

2. Spool insert RS232/485 data interface card in the data interface spool
Flickering Program runs normally
RUN Program Run Pilot Lamp
Going out Program runs abnormally
The first channel is
The first channel data Flickering
RXD1 receiving data
receiving indication
Going out Free
The second channel is
The second channel data Flickering
L/D1 receiving data
receiving indication
L / d1 Going out Free
The third channel is
The third channel data Flickering
RXD2 receiving data
receiving indication
Going out Free
The fourthly channel is
The fourth channel data Flickering
L/D2 receiving data
receiving indication
Going out Free
The fifth channel is
The fifth channel data Flickering
RXD3 receiving data
receiving indication
Going out Free
The sixth channel is
The sixth channel data Flickering
L/D3 receiving data
receiving indication
Going out Free
The seventh channel is
The seventh channel data Flickering
RXD4 receiving data
receiving indication
Going out Free
The eighth channel is
The eighth channel data Flickering
L/D4 receiving data
receiving indication
Going out Free

28
Raisecom Technology Co., Ltd

3. Insert 10BASE-T Ethernet interface card in the data interface spool


Flickering Program runs normally
RUN Program Run Pilot Lamp
Going out Program runs abnormally
The first channel is
The first channel data Flickering
RXD1 receiving data
receive indication
Going out Free
The Ethernet port of the
Light first channel is connected
The Ethernet port of the
normally
L/D1 first channel connected
The first channel of the
indication
Going out Ethernet port does not be
connected.
The second channel is
The second channel data Flickering
RXD2 receiving data
receiving indication
Going out Free
The second channel
Light Ethernet port is connected
The Ethernet port of the
normally.
L/D2 second channel connected
The second channel
indication
Going out Ethernet port does not be
connected.
The third channel is
The third channel data Flickering
RXD3 receiving data
receiving indication
Going out Free
The Ethernet port of the
Light third channel is connected
The Ethernet port of the
normally.
L/D3 third channel connecting
The Ethernet port of the
indication
Going out fourthly channel does not
be connected.
The fourth channel is
The fourth channel data Flickering
RXD4 receiving data
receiving indication
Going out Free
The Ethernet port of the
Light fourth channel is
The Ethernet port of the
connected normally.
L/D4 fourth channel connected
The Ethernet port of the
indication
Going out fourth channel does not be
connected.

29
Raisecom Technology Co., Ltd

2.7.2. RS232/485 Data Interface Card (RC3000-MB-232/485)

2.7.2.1. Functional Description:

1. Every card offer two low speed asynchronous interfaces whose rate is below 19.2kb/s,

or two RS485 data interfaces.

2.Every channel occupies one time slot,which can be set by network management

software at will.

3. Each pathway can provide transmit and receive circuit.

4. The number of RS232/485 data interface card can be configured according to need.

2U engine case can configure most twenty data interface cards,and 4U engine case

can configure most 104 data interface cards.

The switch setting of RS232/485 data interface card:

(1) RS232/485 Interface Mode Setting:

position:S3, S4, S5, S6, S7, S8


Function:By placing short circuit pip on different place, one can
determine it is RS232 mode or RS485 mode. Place short circuit
pip on the silk-screen RS232 aside, the mode is RS232. Place
short circuit pip on the silk-screen RS485 aside, the mode is
RS485.
Note: Set the switch for S3, S5 and S7 through the first channel.
Set the switch of S4, S6 and S8 through the second channel.

(2) RS485 Matched Load Resistance Setting:

Position:S9,S10,S11,S12
Function:By placing short circuit pip on different place, one can
determine the enable of RS485 is adaptive or not adaptive.
Place short circuit pip on the Y aside, it is adaptive enable mode.
Place short circuit pip on the N aside, it is not adaptive enable
mode.
Note:Set the switch for S9 and S10 through the first channel.
Set the switch of S11 and S12 through the second channel.

30
Raisecom Technology Co., Ltd

(3)RS485 Adaptation Enable Mode Setting:

Position:S1, S2
Function:By placing short circuit pip on different place, one can
determine whether there is matched resistance when the mode
is RS485. Place short circuit pip on the Y aside, it is having
matched resistance mode. Place short circuit pip on the N
aside, it is without matched resistance mode.
Note:Set the switch for S1 through the first channel. Set the
switch of S2 through the second channel.

2.7.3. V.35 Synchronous Data Interface Card (RC3000-MB-V35)

1. Every card provides one N×64kb/s V.35 synchronous interface.

2. Every channel can occupy N time slots(1≤N≤31). Time slot be set by network

management software discretionarily.

3. Each pathway can provide transmit and receive circuit.

4. The number of V.35 synchronous data interface card can be configured according

to need. 2U engine case can configure most twenty data interface cards,and 4U engine

case can configure most 52 data interface cards.

2.7.4. 10BASE-T Ethernet Interface Card(RC3000-MB-ETH)

1. Every card provides one 10BASE-T Ethernet interface.

2. Every channel can occupy N time slots(1 <= N <= 31). Time slot be set by network

management software discretionarily.

3. Each pathway can provide transmit and receive circuit.

4. The number of 10BASE-T Ethernet interface card can be configured according to

need. 2U engine case can configure most twenty data interface cards,and 4U engine

case can configure most 52 data interface cards.

31
Raisecom Technology Co., Ltd

The Switch Setting Of 10BASE-T Ethernet Interface Card:


S

Position:S tip pull switch.

Function:By S one can set the operate mode of Ethernet. There are total eight

switches, the s seventh switch and eighth switch of which are left unused.

Note:

(1) Switch 1:Setting DHCP filter. OFF is enable,and ON is not enable.

(2) Switch 2:Setting NetBios filter. OFF is enable,and ON is not enable.

(3) Switch 3:Setting repeater mode. OFF is ingress repeater mode,and ON is

not ingress repeater mode.

(4) Switch 4:Setting rate of speed. OFF is 100MHz,and ON is 10MHz.

(5) Switch 5:Setting transmittal mode. OFF is full duplex mode,and ON is

half-duplex mode switch

(6) Setting self-adaptive mode. OFF is self-adaption mode,and ON is not

self-adaption mode. (If it is self-adaption mode, both the switch four and switch five are
tune in on OFF end.)

32
Raisecom Technology Co., Ltd

3. CABLE

3.1. RC3000-SUB-MCU 2M cable(120Ω)

Plug Type: one DB37-pin plug


Pin number of Pin number of
2M Signal Name 2M Signal Name
DB37-pin plug DB37-pin plug
4 R1+ 23 R1-
24 T1+ 6 T1-
8 R2+ 27 R2-
28 T2+ 10 T2-
12 R3+ 31 R3-
32 T3+ 14 T3-
16 R4+ 35 R4-
36 T4+ 18 T4-

33
Raisecom Technology Co., Ltd

3.2. RC3000-SUB-E1 spool 2M outline cable

DB62 socket
Pin number of Pin number of
2M Signal Name 2M Signal Name
DB62-pin plug DB62-pin plug
43 R1+ 44 R1-
22 T1+ 23 T1-
1 R2+ 2 R2-
45 T2+ 46 T2-
24 R3+ 25 R3-
3 T3+ 4 T3-
47 R4+ 48 R4-
26 T4+ 27 T4-
5 R5+ 6 R5-
49 T5+ 50 T5-
28 R6+ 29 R6-
7 T6+ 8 T6-
51 R7+ 52 R7-
30 T7+ 31 T7-
9 R8+ 10 R8-
53 T8+ 54 T8-
Balance mode 120 ohm(RJ45)2M outline table
2 R+ 1 R-
5 T+ 4 T-

34
Raisecom Technology Co., Ltd

3.3. VF Cable

Plug structure: DB26 plug

Cable form: Two-end cable

Cable: 16 core voice frequency cable 8X2X0.4

Outline table:
Pin 2/4wire voice cable Automatism station set cable
number of
The output definition of
DB62-pin The color of line The output definition of the cable
the cable
plug
14 Blue 1-2W/4WT
Blue background
5 1-2W/4WT
black zone
15 Red 1-4WR 1A
Red background
6 1-4WR 1B
black zone
17 Green 2-2W/4WT
Green
8 background black 2-2W/4WT
zone
18 Brown 2-4WR 2A
Brown
9 background black 2-4WR 2B
zone
22 Grey 3-2W/4WT
Grey background
21 3-2W/4WT
black zone
20 Yellow 3-4WR 3A
Yellow
19 background black 3-4WR 3B
zone
11 White 4-2W/4WT
White background
2 4-2W/4WT
black zone
12 Pink 4-4WR 4A
Pink background
3 4-4WR 4B
black zone

35
Raisecom Technology Co., Ltd

3.4. E/M Cable

Plug structure: DB26 plug

Cable form:Two-end cable

Cable: 32 core voice frequency cable 16X2X0.4

Outline table:

E/M Card outline


Pin
The plug The color of line The output definition of the
number
cable
14 Black background blue zone 1-E1
5 Blue background black zone 1-M1
15 Brown background red zone 1-E2
6 Red background brown zone 1-M2
17 Black background green zone 1-2W
8 Green background black zone 1-2W
18 White background brown zone 1-4W
9 Brown background white zone 1-4W
22 White background grey zone 2-E1

The DB26 21 Grey background white zone 2-M1


pin plug 20 Blue background yellow zone 2-E2
19 Yellow background blue zone 2-M2
11 Orange background white zone 2-2W
2 White background orange zone 2-2W
12 White background green zone 2-4W
3 Green background white zone 2-4W
16 Black background brown zone 1-SG
7 Brown background black zone 1-SB
10 Blue background white zone 2-SG

1 White background blue zone 2-SB

36
Raisecom Technology Co., Ltd

3.5. 10BASE-T Cable

Plug structure: one DB26 plug, two RJ45 socket

Cable form:Double-end cable, one with two

Cable conductor:Four core Shielded Twisted Pair(STP)(exceeding five types wire)


Outline out:
10BASE data cable outline 10BASE data cable outline
(port 1) (port 2)
Pin
The plug The output The output
number
definition of RJ45 pin number definition of RJ45 pin number
the cable the cable
White background
1 TD-2
blue zone(2)[cable2]
White background
2 RX-2 orange zone(6)
[cable2]
3
4
5
White background
6 TD-1
blue zone(2)[cable1]
White background
DB26 plug 7 RX-1 orange zone 6)
[cable1]
8
9
10 TX+2 blue(1)[cable2]
11 RX+2 orange(3)[cable2]
12
13
14
15 TX+1 blue(1)[cable 1]
16 RX+1 orange (3)[cable 1]

37
Raisecom Technology Co., Ltd

3.6. RS232/485 data cable

Plug structure:one DB26 plug , four DB9 socket

Cable form:Double-end cable , one with four

Cable: 4 core voice frequency cable

outline:

RS232 RS485
DB26 output output
plug definition definition Cable 1 Cable 2 Cable 3 Cable 4
number of the of the
cable cable
8 RX1 RX1+ white
17 RX1- red
14 TX1 TX1+ green
5 TX1- brown
15 RX2 RX2+ white
6 RX2- red
16 TX2 TX2+ green
7 TX2- brown
3 RX3 RX3+ white
12 RX3- red
20 TX3 TX3+ green
19 TX3- brown
10 RX4 RX4+ white
1 RX4- red
11 TX4 TX4+ green
2 TX4- brown
25 GND GND Black Black
26 GND GND Black Black

38
Raisecom Technology Co., Ltd

3.7. V35 data cable

Plug structure:One DB26 plug , two M34socket


Cable form:Double-end cable, one with two

Cable: 16 core voice frequency cable 8X2X0.4

Outline table:
V.35 data cable outline(port 1) V.35 data cable outline (port2)
Pin
The plug Definition of Definition of
number (M34 socket)pin number (M34 socket)pin number
output wire output wire
1 RC-2 brown background black zone(X)
2 RD+2 Green(R)
3 TD+2 Blue(P)
4 TXC-2 grey background black zone(W)
red background black zone
5 TC-1
(AA)
brown background black zone
6 RC-1
(X)
7 RD+1 green(R)
8 TD+1 blue(P)
grey background black zone
9 XTC-1
(W)
10 RC+2 brown(V)
11 RD-2 green background black zone(T)

DB26 12 TD-2 blue background black zone(S)


plug 13 XTC+2 grey(U)
14 TC+1 red(Y)
15 RC+1 brown(V)
green background black zone
16 RD-1
(T)
blue background black zone
17 TD-1
(S)
18 XTC+1 grey(U)
19 TC-2 red background black zone(AA)
20 TC+2 red(Y)
21 PGND yellow background black zone (A)
yellow background black zone
24 PGND
(A)
25 GND yellow(B)
26 GND yellow(B)

39
Raisecom Technology Co., Ltd

Notice:In M34 plug, C (RTS)--D (CTS) are short-circuited, E (DSR)--F (DCD)--H (DTR)

and are short-circuit.

B Signal Ground
P Transmit Data (Signal P)
R Receive Data (Signal P)
S Transmit Data (Signal N)
T Receive Data (Signal N)
U External Transmit Clock (Signal P)
V Receive Clock (Signal P)
W External Transmit Clock (Signal N)
X Receive Clock (Signal N)
Y Transmit Clock (Signal P)
AA Transmit Clock (Signal N)

40
Raisecom Technology Co., Ltd

3.8. V35 and 10BASET data cable

Plug structure:one DB26 plug , one M34socket, one RJ45 socket


Cable form:double-end cable , one with two

Cable: 16 core voice frequency cable[V35] 8X2X0.4 and Four core Shielded Twisted

Pair(STP)(exceeding five types wire)[10BASET]

Outline table:
V.35 data cable outline(port1) 10BASE data cable outline(port 2)
The output
The Pin The output
definition
plug number definition of (M34 socket)pin number RJ45 socket pin number
of the
the cable
cable
white background blue
1 TD-2
zone(2)[cable2]
white background
2 RX-2
orange zone(6)[cable2]
red background black
5 TC-1
zone(AA)[cable 1]
brown background black
6 RC-1
zone(X)[cable1]
7 RD+1 green(R)[cable1]
8 TD+1 blue(P)[cable1]
grey background black
9 XTC-1
DB26 zone(W)[cable1]
plug 10 TX+2 blue(1)[cable2]
11 RX+2 orange(3)[cable2]
14 TC+1 red(Y)[cable1]
15 RC+1 brown(V)[cable1]
green background black
16 RD-1
zone(T)[cable1]
blue background black
17 TD-1
zone(S)[cable1]
18 XTC+1 grey(U)[cable1]
yellow background black
24 PGND
zone (A) [cable1]
25 GND yellow(B)[cable 1]
Notice: In M34 plug, C(RTS)--D(CTS) are short-circuit , E(DSR)--F(DCD)--H(DTR) and
are short-circuit.

41
Raisecom Technology Co., Ltd

3.9. RS232/485 monitor cable

RS232 monitor cable


The output
DB9 plug/socket)
RJ45 plug definition of the The color of line
pin number
cable
1
2 TX 2 blue
3 RX 3 orange
4
5 GND 5 green
6
7
8
RS485 monitor cable
The output
DB9 plug pin
RJ45 plug definition of the The color of line
number
cable
1
2
3
4 TX+ 2 blue
5 GND
white background
6 TX- 1
blue zone
white background
7 RX- 3
orange zone
8 RX+ 4 orange

3.10. -48v Power cable

DB3 plug Signal definition Backboard mark Line color


A1 minus - Red
A2 Protect ground P.G. Yellow
A3 positive + Black

42
Raisecom Technology Co., Ltd

Address: 2nd Floor, South Building of Rainbow


Plaza, No.11 Shangdi Information Road, Haidian
District, Beijing
Postcode: 100085
Tel: +86-10-82883305
Fax: +86-10-82883056
Email: export@raisecom.com
http://www.raisecom.com