Sunteți pe pagina 1din 7

Auto Door Sensor

Auto door sensor


(A)

▣Features Counter

lStop time selection function


(Selectable stop time 2 / 7 / 15sec.) (B)
Timer
l4 steps variable function for front detecting area
(7.5 ,14.5 ,21.5 ,28.5 4steps variable)
lRight/Left detecting area elimination function
(C)
lSimple design and various cover color Temp.
controlle
U Standard : Silver
U Option : Black, White, Bronze, Nickel)
lWide range of power suppply(24-240VAC, 24-240VDC) (D)
Power
lMicro processor built in controlle

Please read "Caution for your safety" in operation


! manual before using. (E)
Panel
meter

▣Specifications
(F)
Model ADS-A Tacho/
Speed/
Cover color Silver(Optional color : Black, White, Bronze, Glossy, Nickel) Pulse
meter
Power supply 24-240VAC ±10% 50/60Hz, 24-240VDC ±10%(Ripple P-P:Max. 10%)
Power consumption Max. 4VA at 240VAC
(G)
Control output Relay contact capacity : 50VDC 0.1A(Resistive load) Display
(*1) Relay contact output unit
Relay contact composition : 1a
Relay life cycle Mechanical : Min. 20,000,000, Electrical : Min. 50,000
Mounting height 2.0m ~ 2.7m(Max. detecting distance : 3m)
(H)
Sensor
Detection area Infrared reflection method(Diffuse reflective type)
controlle
Detection method Time delay approx. 0.5sec.
Output holding time Selectable 2 / 7 / 15sec. by slide switch
(I)
Holding time of Proximit
H, L(Interfearence prevention switch) sensor
stationary detection
Interference prevention 7.5°, 14.5°, 21.5°, 28.5°: Adjust angle adjustment lever
(J)
Adjustable detection (1, 2, 3 Area), (7, 8, 9 Area) Eliminate each by each : Photo
area Adjustment with switch for eliminate Right/Left detecting area electri c
sensor
Light source Infrared chip diode(modulated)
Indication Normal : Red LED turns on, Detection : Red LED turns off
(K)
Connection Connector wire connection Pressur
sensor
Insulation resistance Min. 20MΩ(at 500VDC)
Noise strength ±2,000V the square wave noise(pulse width:1㎲) by the noise simulator
Dielectric strength 1,000VAC 50/60Hz for 1 minute (L)
Rotary
Vibration 1.5mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 2 hours encoder

Shock 100m/s²(Approx. 10G) in X, Y, Z directions for 3 times


Ambient illumination Sunlight : Max. 11,000 , Incandescent lamp : Max. 3,000 (M)
5-Phase
Ambient temperature -20℃ ~ +50℃(at non-freezing status), Storage : -20 ~ +70℃ stepping
motor &
Ambient humidity 35 ~ 85%RH, Storage : 35 ~ 85%RH Driver &
Controlle
Accessories Cable : 2.5m, Mounting screw : 2EA, Mounting template
Protection IP50(IEC specification)
Material Case : ABS, Lens : Acryl, Lens cover : Acryl
Weight Approx. 320g
※(*1)Don't use Load which is beyond the correct switching capacity of contact point of Relay.
It can cause bad insulation, contact fusion, bad contact, relay breakdown, fire etc.

J-62
ADS-A
▣Parts description
1
5 2
1 Interference prevention
switch
Power sup ply : 24 - 220VAC50/60Hz

2 Holding time setting switch


L H 2 7 15
24 - 220VDC
DOOR SENSOR Ad ju st ab le an g le
D : 28. 5
Intercepting Interfer ence H olding time(sec) Adj us ta bl e a re a Power con sumpt ion : 4VAMax. 50mA Max.
Outpu t contact : Relay output (1a) 50VDC0.1A

ADS-A
(Resistive load)
C : 21. 5 ON ON

3 Eliminate detection area


B : 14. 5
A : 7.5
1m 1m Gray : Power line
OFF OF F
D Wh ite : Signal line
2m 2m

width lever
C
H
B 2. 7m 2 .7 m Sen sit ivit y
D C B A 1 2 3 4 5 6 7 8 9
A 1m 0. 5m 0 0 . 5m 1m

4 Angle adjustment lever


1 . 5m 1m 0 . 5m 0
L
3A 090D MA DE IN K OR EA

5 Body connect

3
4

▣Dimensions

224

Unit:mm

▣Installation

Installation ! Caution
1. Attach mounting template at mounting
position ! Warning It may give an electric shock.
(Mounting height : 2.0m ~ 2.7m) U When this unit is used with cable outlet removed from
U Drill ø3.4mm hole based on mounting cover, it must be installed indoors.
template. (Electric shock or damage can occur if water flows
U In case of wiring the cable on the wall to through cable outlet.)
hide the cable, drill ø9mm hole.
U Install the unit after removing the
mounting template.
! Caution People can be jammed in the door.
U If unit is installed higher than 2.7m in height, it may
Max. not detect children.
2.7m
U If unit is installed lower than 2.0m in height, it may
not work properly.

Mounting hole

Mounting template

Center

Hole for inside


cable connection

J-63
Auto Door Sensor
▣Installation
(A)
Installation ! Caution Counter

2. Please install this unit with mounting ! Caution Mounting the unit
screws after removing protection cover.
U Do not put excessive tightening torque on screw bolt (B)
when mounting this unit. Timer

① It may result in mounting hole damage.



<Protection cover detachment> (C)
Temp.
U Pulling left thumb toward ①, key lock will be released controlle
and pull right thumb toward ②, protection cover and
body will be detached.
(D)
Power
3. The code part of wiring code should be controlle

connected to main control part.


U Install the connector to be connect to the
(E)
body. Panel
meter

4. Connect the extension cable and the ! Caution Connection of the connector
main controller. (F)
U Plug in the connector of the extension cable and the Tacho/
Speed/
connector of the unit completely. Pulse
meter
The unit may not work normally with inferior contact.

It can be disconnected (G)


Body by pushing this position. Display
(Gray:Power line, unit
White:Signal line)

Connection wire(Length:2.5m) (H)


Sensor
controlle

(I)
▣Adjustment Proximit
sensor

Please turn on the power. (J)


Photo
electri c
1. Check of the detection area sensor

This characteristic of the detection area is


shown in below chart and drawing. (K)
(Unit:mm) Pressur
sensor
Mounting
height

(L)
Rotary
2m encoder
64

Mount ing 2.2m (M)


height 70
5-Phase
2.7m stepping
motor &
2.5m Driver &
80
Controlle

2.7m
86

J-64
ADS-A
▣Adjustment

2. Adjustable detection area


! Caution People can be jammed in the door.
Adjustable 7 in each step.
U Be sure to install a photo sensor as the safe equipment.
(Detection area angle step : 7.5 ~ 28.5 )
There is ADS-S sereis for a Door side sensor.
A djus t in g a ngl e
U Even if the unit is installed at narrow area from
28.5 the door, the rail of the door is dangerous.
D
C 21.5
B
A 14.5
7.5

21°

1m

1.5m

2m

2.7m

D C B A

1.5m 1m 0.5m 0

3. Adjustment of Left, Right detection ! Caution People may run against the door.
area width
U When eliminating the Right/Left detecting range, be
Detection area width 1 2 3 can be eliminated
sure to install the unit at place where a person
by left lever, 7 8 9 by right lever.
approaches at the front of the door.
U Use the unit as removing non-detection
If case of eliminating detection area width:
area by the lever adjusting width at
U If a person approaches at the side of the door, they
narrow detection area.
may not be detected and the door will not open.
※Turn the adjuster till it stops it toward
arrow direction by a (-)driver. Rig ht/Left full rang e d etectio n Eliminating left d etectio n area
ON ON ON ON

O FF O FF O FF O FF

ON ON

OFF OFF

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9

Eliminatin g right detection area Eliminating right/left detection area


ON ON ON ON

1m OFF OFF OFF OFF

15°
49°
2m

2.7m 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9

1m 0.5m 0 0.5m 1m ※You can not eliminate individual areas like 1 area eliminat ion,
7 area elimination.

J-65
Auto Door Sensor
▣Adjustment
(A)
4. How to set the switch for interference ! Caution Door can be opening and closing Counter
prevention
When several door sensors are installed simultaneously
In case of using several door sensors in close
without considering any interference detection, it may
proximity, please set the interference
cause malfunction by another door sensor even though (B)
prevention switches differently. Timer
no moving object exists.
< Interference prevention >
Interference prevention If detection area of the door sensors is overlapped,
switch of each sensor (C)
set each switch in difference or install the unit on Temp.
controlle
non-overlapped detection area.

(D)
L H 2 7 15 Power
Inte rcep ting In terfe ren ce Ho lding time(sec ) Adjustable are controlle
ON ON Overlapped
1m

OFF OFF
2m (E)
Panel
2 .7 m meter
D C B A 1 2 3 4 5 6 7 8 9
L H L H L H
1 .5 m 1m 0.5m 0 1m 0.5m 0 0. 5 m 1m

(F)
5. Holding time switch setting ! Caution People can be jammed in the door. Tacho/
You can set the holding time by the Holding Speed/
Pulse
U Be sure to install a assisting sensor as a safe equipment.
time switch. (Selectable 2 / 7 / 15sec.) meter
There is ADS-S sereis for a Door side sensor.
Select the switch U The door will close after the time set by the holding time
for Holding time (G)
switch has elapsed. Display
unit

<Holding time>
U When people or objects stay in detection area after (H)
L H 2 7 15 Sensor
Inte rcep ting In terfe ren ce Ho lding time(sec ) Adjustable are auto tuning(Set 7sec. for Holding time), it will detect controlle
ON ON the stationary people or objects for set time by the
1m
holding time switch, and then the sensor's output turns
OFF OFF
2m
off after set time.) (I)
Proximit
D C B A
2.7m
1 2 3 4 5 6 7 8 9
sensor
1 . 5m 1m 0 . 5m 1m 0 . 5m 0 . 5m 1m

6. Sensitivity Setting (J)


! Caution Door can be opening and closing Photo
Even though people in the detection electri c
H sensor
area, if the sensor don't operated, Please check the normal operation by turning the power
turning the volume toward to H. ON/OFF after finishing the sensitivity setting.
L
The sensitivity will be increased. It any not operate normally because the install setting is (K)
Pressur
changed before and after sensitivity setting sensor
Even though people in the detection
H
area, if the sensor operated,
(L)
turning the volume toward to L. Rotary
L
The sensitivity will be Decreased. encoder

7. Unit cover (M)


! Warning It may give an electric shock. 5-Phase
U Mount the cover on the unit. stepping
U Do not take off its cover on operating the unit. motor &
U In case of using outlet to wire exposed Driver &
U In case of using the cable outlet, the unit must be Controlle
cable, take off point.
Cable outlet installed in inner position of door.
U Be sure that this unit does not come in direct touch
with water. It may cause human injury or give an
electric shock.

J-66
ADS-A
7. Sensitivity
After turning the power, please stand by U If don't pass about 3 sec after turning the power,
in the condition in which there is no moving holding detection is impossible
object in the detection area.

8. Check of detecting operation


Check detecting operation as follow drawing.

Entry
activation

Tuening on Before entry Entre position of Out of detection


the power position detection area Holding detection area

LED LED LED LED LED


Orange ON OFF OFF OFF OFF

Operation LED LED LED LED LED


indicator Gr een
OFF ON OFF ON ON
LED LED LED LED LED
Red
OFF OFF ON OFF OFF

Output :
OFF Output : OFF
OFF ON ON for OFF
Output contact OFF after
holding
time 0.5sec.

9. Maintenance ! Caution It may give an electric shock.


U If the detection lens is unclean, the unit
U Do not wash the unit with water.
may cause malfunction, in this case,
U Do not repair or disassamble the unit.
please clean it with dry tissue and natural
detergent.
U Do not use an organic cleaner such as
benzene, etc.

▣Trouble shooting
Trouble Check Correction action

lCheck the power cable and adjust power


lPower voltage
It does not work. voltage.
lCable cut, disconnection
lCheck connector and wiring.

Sometimes it
lThe detection lens is unclean lClean it with dry tissue and natural detergent.
does not work.

lCheck status of installation.


lThere are moving objects.
lCheck surrounding environment for
lBy occurring sudden change of
installation.
It operates even bottom surface.
lInstall the unit to avoid overlap for detection
if people do not lDetection area is overlapped.
area.
enter in detection lThere is equipment causing strong
lSet the switch intercepting interference.
area. noise.
lDo not install the equipment producing
lA drop of water is placed at the
strong noise near the sensor.
lens.
lRemove a drop of water.

J-67
Auto Door Sensor
▣Installation
1. This product is not qualified for waterproof. 4. If you place a movable object in the detection area, (A)
Counter
Please install without being directly contacted it may cause malfunction by detecting the object
with rain or snow. because of natural phenomenon like wind etc.
It may cause breakdown and short circuit.
(B)
Timer

(C)
Temp.
controlle

(D)
2. Don't install wheremreflecting light like sunshine 5. Detection hole must face the bottom, if not, the Power
controlle
directly reaches. It may don't operate normally. sensor doesn't operate normally.

(E)
Panel
meter

(F)
Tacho/
3. Don't install where smoke and vapor occurs. Speed/
Pulse
It may don't operate normally. meter

(G)
Display
unit

(H)
Sensor
▣Caution for using controlle

! Warning It may give an electric shock. ! Caution Door may not open
Do not take off its cover when the unit is operating. U When eliminate the Right/Left detecting range, be (I)
sure to install the unit at place where a person Proximit
Be sure that this unit does not come in direct contact sensor
with water. approaches at the front of the door.
U When using this unit with cable outlet removed, this If a person approaches at the side direction of the
unit must be installed indoors. door, the door may not open because the person is (J)
not within detection area width. Photo
If installed outdoors, it may give an electric shock electri c
or damage by direct contact with water when the sensor
water inflows through cable outlet. ! Caution It may cause malfunction.
U Do not wash the unit with water. B e sure that this
U When wiring the photoelectric sensor with high voltage (K)
unit does not come in direct contact with water.
line, power line in the same conduit, it m ay cause Pressur
It may cause damage or give an electric shock. sensor
malfunction.
U Do not repair or disassemble the sensor.
Therefore please wire separately or use different
It may cause damage or give an electric shock.
conduit.
(L)
Be careful of human injury U Do not install this unit at place where there is dust Rotary
! Caution by the door. or corrosive gas. encoder

U Do not install this unit at place higher than 2.7m. U The wire connection shall be used as short as possible
It may not detect small children due to lack of sensitivity. in order to avoid malfunction by surge. (M)
5-Phase
U Do not install this unit under 2m. U When it is covered by dirt at lens, please clean the stepping
motor &
It may not operate normally. lens with dry cloth, but do not use any organic Driver &

U Please install photo sensor as the safety equipment, materials such as alkali, acid, chromic acid. Controlle

the door will close after passing Holding time.


It may not be able to detect children or old people
continuously and jammed in the door.
U Please install photo sensor as the safety equipment.
This unit holds the door for Holding time.
When the Holding time passed, the door will be closed.
People may be jammed in the door.

J-68

S-ar putea să vă placă și