BW Series

Area sensor

▣Features
lLong detecting distance up to 7M
l22 types of products
(Beam pitch : 20/40mm, Sensing height : 120~940mm)
lIncreased detection stability by minimizing the non sensing area
lEasy identification of the side, front and long distance by the
indicator of high illumination, TWIN motions
lSelf failure diagnosis function incorporated
lPolished design & minimum size(W28.6×T22.6×H□)
lIP65 protecting structure

Please read "Caution for your safety" in operation


! manual before using.

▣Specifications
NPN open BW20-08 BW20-20 BW20-32 BW20-44 BW40-04 BW40-10 BW40-16 BW40-22
collector output BW20-12 BW20-24 BW20-36 BW20-48 BW40-06 BW40-12 BW40-18 BW40-24
(Standard type) BW20-16 BW20-28 BW20-40 BW40-08 BW40-14 BW40-20
Model
BW20-08P BW20-20P BW20-32P BW20-44P BW40-04P BW40-10P BW40-16P BW40-22P
PNP open
BW20-12P BW20-24P BW20-36P BW20-48P BW40-06P BW40-12P BW40-18P BW40-24P
collector output
BW20-16P BW20-28P BW20-40P BW40-08P BW40-14P BW40-20P
Detecting type Through-beam type
Detecting distance 0.1 ~ 7m
Detecting target Opaque materials of min.ø30mm Opaque materials of min.ø50mm
Optical axis pitch 20mm 40mm
Number of optical axes 8~48pcs 4~24pcs
Detecting width 140~940mm 120~920mm
Pointing angle Within ±5°(At over 3m detecting distance)
Power supply 12-24VDC ±10%(Ripple P-P:Max. 10%)
Reverse power protection Built in
Current consumption Emitter : Max. 80mA, Receiver : Max. 80mA

U NPN open collector output ☞ Load voltage : Max. 30VDC, Load current : Max. 100mA,
Control output Residual voltage : Max. 1V
U PNP open collector output ☞ Load current : Max. 100mA, Output voltage : Min.(Power supply-2.5)V
Operation mode Light ON only
Short-circuit protection Built-in
Response time Min. 12ms
Light source Infrared LED(850nm modulated)
Synchronization type Timing method by synchronous line
Self-diagnosis Ambient light monitoring, Emitter/Receiver light circuit monitoring, Output circuit monitoring
Interference protection Interference protection by master/slave function
Ambient temperature -10 ~ +55℃(at non-freezing status)
Storage temperature -20 ~ +60℃
Ambient humidity 35 ~ 85%RH
Storage humidity 35 ~ 85%RH
Ambient illumination Sunlight : Max. 11,000 , Incandescent lamp : Max. 3,000
Noise strength The square wave noise by the noise simulator(Voltage:±240V, Period:10ms, Pulse width:1㎲)
Dielectric strength 1,000VAC 50/60Hz for 1minute
Insulation resistance Min. 20MΩ(500VDC)
Vibration 1.5mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 2 hours
Shock 500m/s²(50G) in X, Y, Z directions for 3 times
Protection IP65(IEC standard)
Material U Body : Aluminum U Cover, Rens : Acril
Accessory Bracket A : 4EA, Bracket B : 4EA, Bolt : 8EA
Net weight Approx. 1.4kg(For 48 optical axis)

J-75
Area Sensor
▣Characteristic data
(A)
Parallel shifting characteristic Angle characteristic Counter

Measuring method Data Measuring method Data

10 8
(B)
Timer

8
6

6 Receiver (C)
Receiver Temp.
4
controlle
4

2
Emitter 2 Emitter (D)
Power
controlle

300 200 100 0 100 200 300 30° 20° 10° 0 10° 20° 30°

Left ← Center → Right Left ← Center → Right


(E)
Operation positionℓ (mm) Operation angleθ
Panel
meter

▣Dimensions (F)
Tacho/
<Emitter> <Receiver> Speed/
28.6 Pulse
28.6
meter

22.6 22.6
10 (G)
Display
Optical axis
unit

100 Model L (mm) Model L(mm)


(H)
BW20-08(P) BW20-32(P)
160mm 640mm Sensor
BW40-04(P) BW40-16(P) controlle
Optical axis BW20-12(P) BW20-36(P)
L 240mm 720mm
Operation BW40-06(P) BW40-18(P)
indicat or (I)
BW20-16(P) BW20-40(P) Proximit
BW40 Series 320mm 800mm sensor
Optical axis 40 BW20 S eries BW40-08(P) BW40-20(P)
pitch 20 Optical axis BW20-20(P) BW20-44(P)
pitch 400mm 880mm
60 BW40-10(P) BW40-22(P) (J)
Photo
10
BW20-24(P) BW20-48(P) electri c
480mm 960mm
BW40-12(P) sensor
ø 5 Cable BW40-24(P)
BW20-28(P)
300 560mm
M12 BW40-14(P)
(K)
Unit:mm Pressur
sensor

lBracket A lBracket B
(L)
Rotary
encoder
ø20 t=2
R1.7 R1.7
(M)
5-Phase
stepping
motor &
Driver &
Controlle
26.5 t=2
18 ø 20

M4 Bolt
16 M 4 Bolt 10

Unit:mm

J-76
BW Series
▣Input/Output circuit and connection diagram
lNPN open collector output type lPNP open collector output type

+V(Brown) +V(Brown)
1 1
+ +
S YNC(White) SYNC(White)
2 2
- -
TEST(Black) TES T(Black)
4 4

0V(Blue) 0V(Blue)
3 3

+V(Brown) +V(Brown)
1 1
S YNC(White) Over current
2 protection
Output element circuit
monitoring OUT(Black) SYNC(White)
4 Load 2
function

Over current Output element OUT(Black)


protection monitoring 4 Load
circuit function
0V(Blue) 0V(Blue)
3 3

▣Structure
Upper operation indicator is set additionally in case
the number of the optical axes is more than 24pcs in
BW20-Series and more than 12pcs in BW40-Series.

Emitter Receiver

<Operation indicator >


LED color Emitter Receiver
Green POWER ON
Green Yellow Red Yellow Green Yellow TEST(M/S) UNSTABLE
Red OFF

<Wiring Connection >


Pin No Cable color Emitter Receiver
1 Brown 12-24VDC 12-24VDC
1 1
2 2
2 White SYNC SYNC
3 4 3 4
3 Blue 0V 0V
4 Black TEST(M/S) OUT

Acces sory Accessory

▣Connecting cable(Option)

Cable length(L)
Model Cable length(L) Connector color
43.5 CID4-3 3m
ø5 Cable
CID4-5 5m Emitter : BLACK
CID4-7 7m Receiver : GRAY
1
2

3
4
CID4-10 10m
※Connecting cable is optional and sold in
a set(2pcs).

J-77
Area Sensor
▣Bracket mounting
(A)
Counter

(B)
Timer

(C)
Temp.
controlle

(D)
Power
controlle

▣Optical axis pitch/Number of optical axes/Detecting width


(E)
Panel
Number of optical axes Model Optical axis pitch meter

BW20-□□(P) 20mm
n
BW40-□□(P) 40mm (F)
Tacho/
Speed/
Number of Detecting Number of Detecting Pulse
Model optical axes width Model optical axes width meter

BW20-08(P) 8 140mm BW40-04(P) 4 120mm


Detecting width BW20-12(P) 12 220mm BW40-06(P) 6 200mm (G)
Display
BW20-16(P) 16 300mm BW40-08(P) 8 280mm unit

5 BW20-20(P) 20 380mm BW40-10(P) 10 360mm


4 BW20-24(P) 24 460mm BW40-12(P) 12 440mm
(※) (H)
3 BW20-28(P) 28 540mm BW40-14(P) 14 520mm Sensor
32 620mm BW40-16(P) 16 600mm controlle
2 BW20-32(P)
1 BW20-36(P) 36 700mm BW40-18(P) 18 680mm
(※)Optical axis pitch BW20-40(P) 40 780mm BW40-20(P) 20 760mm (I)
BW20-44(P) 44 860mm BW40-22(P) 22 840mm Proximit
sensor
BW20-48(P) 48 940mm BW40-24(P) 24 920mm

(J)
Photo
▣Operating mode electric
sensor

Stable light receiving area ON Level


(K)
Pressur
OFF Level sensor
Unstable light receiving area

Unstable light cut off area


(L)
Rotary
Stable light cut off area encoder

ON LED ON (M)
5-Phase
(Green LED) OFF stepping
mot or &
Dr iver &
UNSTABLE LED ON Controlle

(Yelloe LED) OFF

OFF LED ON
(Red LED) OFF

Control output ON
OFF

J-78
BW Series
▣Function
◎Light emitted stop function(External diagnosis lMASTER/SLAVE connections
function) <NP N open collect or output > <PNP open collect or output >

Light emitted will be stopped and yellow LED is MASTER MASTER


flickered if supplying 0V to test input on the emitter. +V
Brown
+V
Brown

It is for checking malfunction of the sensors during White White +


SYNC + SYNC
- -
TEST input on the emitter is 0V. (Control output of TEST Black TEST Black
the receiver is OFF as it becomes light cut off when (M/S)
Blue
(M/S)
Blue
0V 0V
the light emitted is stopped)
Brown Brown
lConnections for TEST input +V +V
White White
SYNC SYNC
Vcc (For contact (For solid state
relay) relay) TEST Black TEST Black
Input part Load Load
(M/S) (M/S)
int ernal circuit R TEST(Black) Blue Blue
4 0V 0V

or
GND 0V(Blue)
3 SLAVE SLAVE
Brown Brown
+V +V
lControl output pulse by TEST input White White
SYNC SYNC
Emitter TEST Open Black Black
TEST TEST
(Black) (M/S) (M/S)
ON(0V) Blue Blue
T1 T1 T 1>=50ms 0V 0V

Brown Brown
Receiver OUT ON T2 T2 +V +V
(Black) OFF White White
SYNC SYNC
T 2>=20ms
TEST Black TEST Black
(M/S) Load Load
(M/S)
No rmal Abno rmal Blue Blue
0V 0V
◎Self-diagnosis function
Control output will be OFF and operating indicator is
▣Installation
ON when malfunction is checked by self-diagnosis
regularly in normal operation. ◎For direction of installation
lDiagnosis items Emitter and receiver should be installed in same
up/down
U Emitter : ①Break of light emitting element
direction.
②Break of light emitting circuit
Emitter Receiver Emitter Receiver
③Malfunction of MASTER/SLAVE
line(Operation in MASTER)
U Receiver : ①Break of light receiving circuit
②Break of output circuit
③Over current at output part ◎For reflection from the surface of wall and flat
④Synchronous line malfunction
When installed as below the light reflected from
⑤Ambient light received
the surface of wall and flat will not cut off.
lSee J-80Page, "▣Operation indicator" for the Please, check whether it operates normally or not
display operation of diagnosis. with a detecting target before using.
(Interval distance : Min. 0.5m)
◎Interference protection function
Emitter Receiver Detecting target
In case of using 2pcs of sensor in parallel in order E mit ter Receiver
to extend detecting width the detection will be Detecting target Reflecting
Reflecting light
failure because as light interference. light
This function is to avoid the light interference as
operating a sensor in MASTER and another sensor Bottom Wall
in SLAVE to protect these kinds of failures.
lTime chart for MASTER/SLAVE light emitting pulse
◎For protection of interference
It may cause interference when installing more than
MAS TER
2sets of the sensor. In order to avoid the interference
of the sensor please install as following figures and
SLAVE
use the interference protection function.

J-79
Area Sensor
<Light emitting direction s hould be opposite bet ween 2 set s >
▣Inspection/Treatment for malfunction
Receiv er1 Emitter1 Emitter2 Receiver2 Emitter1 Receiver1
Malfunction Caution Treatment (A)
Counter
Power Supply rated power

Cut-off line, wiring failure Check the wiring


Non-operation
Emitter1 Receiver1 Emitter2 Receiver2 Use within rated
Rated connection failure
detecting distance (B)
Timer
Pollution by dirt of sensor Remove dirt by soft
Non-operation in cover brush or cloth
Receiver2 Emitter2 sometimes
Connector connection failure Check the assembled
Emitter1 Receiv er1 Emitter1 Receiver1 part of the connector (C)
Temp.
Out of rated detecting Use within rated
controlle
distance detecting distance

There is an obstacle to cut


Receiver2 Emitter2 Control output is OFF off the light emitted between Remove the obstacle
even though there is emitter and receiver (D)
Emitter1 Receiv er1
not a target object. Power
There is a strong electric controlle
Put away the strong
wave or noise generator such
as motor, electric generator, electric wave or noise
Emitter2 Receiver2 generator.
high voltage line etc.)

Emitter2 Receiver2 (E)


Break of light emitting Break of light emitting Panel
element LED displayed element
<Shield panel should be ins talled between 2 sets > meter
Break of light emitting Break of light emitting
Emitter1 Receiver1 Emitter2 Receiver2
circuit LED displayed circuit
Contact our company (F)
Break of light receiving Break of light receiving
element LED displayed element Tacho/
Speed/
Break of output Pulse
element LED displayed Break of output element meter
Shield panel
Synchronous l ine connection
<It should be installed out of the installation allowable distance > Synchronous line Check the wiring
failure or cut off
Emitter1 Receiver1 malfunction LED (G)
Detecting Installation allowable displ ayed Break of synchronous circuit Display
distance(L) distance(D) Contact our company
of emitter or receiv er unit
0.1~3m Min. 0.4m
Control output line shorted Check the wiring
Emitter2 Receiver2
Min. 3m L×tan8°
=L×0.14 min. Over current LED
displ ayed Check the rated load
Over load
※It may be a little different based on capacity (H)
L(m) installation environment. Sensor
Ambient light receiving Ambient light received to Remove the ambient controlle
LED displayed receiver light

▣Operation indicator Emitter malfunction


LED displayed Emitter malfunction
Treat after checking
the emitter display LED
Emitter Receiver (I)
Proximit
Item Indicator Indicator
Control sensor
Green Yellow Green Yellow Red output
Power supply
MASTER operation (J)
Photo
SLAVE operation electri c
sensor
Test input
Break of light emitting element OFF
Break of light emitting circuit OFF
(K)
ON Pressur
Stable light received
sensor
Unstable light received ON
Unstable light cut off OFF
Stable light cut off OFF (L)
Break of light receiving circuit OFF Rotary
encoder
Break of output element OFF
Synchronous line malfunction OFF
(M)
Over current OFF 5-Phase
stepping
Ambient light received OFF motor &
Emitter failure OFF Driver &
Controlle

Display classification list


Light ON
Light OFF
Flickering by 0.5 sec.
or Flickering simultaneously by 0.5 sec.
Cross-Flickering by 0.5 sec.
Sequence-Flickering by 0.5 sec.

J-80