Ampere Meter

▣Features
(A)
Counter
lMax. display: 19999(M5W), 1999(Others)
lAUTO ZERO function or HOLD function(Except M5W)
lRMS/AVG value selection function(AC Voltage)
(B)
l7Segment LED Display Timer

lCase size by DIN specification


lIndication type only, Single preset output type,
(C)
Double preset output type Temp.
controlle

Please read "Caution for your safety" in operation


! manual before using. (D)
Power
controlle

▣Ordering information
(E)

M 4 W A A 1 Panel
meter

(F)
Tacho/
M4Y / M4W / M4M M5W
Speed/
NO DC INPUT AC INPUT DC INP UT AC INPUT Pulse
(F・S) (F・S) (F・S) (F・ S) meter

1 199.9μA 19.99mA 1 99.99 μA 1 9.999 mA


2 1.999mA 199.9mA 1 .9999 mA 199.99mA (G)
19.99mA 19.999mA 1.9999A Display
3 1.999A unit
Note1) Measuring input 4 199.9mA 19.99A 199.99mA 19.999A
5 1.999A 199.9A 1.9999A 199.99A
6 19.99A 1999A 19.999A 1999.9A (H)
7 199.9A 199.99A Sensor
controlle
8 1999A 1999.9A
XX Option Option
(I)
AVG value
Proximit
R RMS value sensor

V Volt Meter
A Ampere Meter (J)
Photo
electri c
Note2) D DC type sensor
A AC type
Indication type
(K)
1P Single setting Pressur
sensor
2P Double setting

Note3) Y DIN Size W72×H36mm


W DIN Size W96×H48mm (L)
Rotary
M DIN Size W72×H72mm encoder

4 3½digit
(M)
5 4½digit 5-Phase
stepping
motor &
M Meter Driver &
Controlle

Note1)Measuring input and display is 1:1 for DC INPUT No.1to 5 and AC INPUT No.1 to 3, DC INPUT No.6 to 8 is
used with DC50mV Shunt, AC INPUT No.4 to 6 are used with C.T(Current tranducer)
Note2)RMS only applies to AC measuring type. Do not enter "R" with DC model.
Note3)M4Y, M5W are an indication type.

E-30
M4Y/M4W/M5W/M4M Series
▣Specifications
M4Y-DV- M4W-DA- M4W1P-DA- M4W2P-DA-
M4Y-AA - M4W-AA - M4W1P-AA - M4W2P-AA -
Model
M5W-DA- M4M-DA- M4M1P-DA- M4M2P-DA-
M5W-AA- M4M-AA - M4M1P-AA - M4M2P-AA -
Measurement function DC, AC voltage
Max. allowable input 150% for each input specification

★5VDC(Except M5W) ★24-70VDC


Power supply ★24-70VDC ★100-240VAC 50/60Hz
10 0-2 40V AC 5 0/60 Hz 110/220VAC 50/60Hz

Allowable voltage range 90 ~ 110% of rated voltage


Power consumption DC : 2W, AC : 4VA DC : 2W, AC : 5VA
Display method 7Segment LED Display
Character height 14.1mm M4W:10.16mm, M4M:10mm
DC : F・S ±0.2% rdg ±1digit
Display accuracy
AC : F・S ±0.5% rdg ±1digit
Sampling cycle 300ms
A/D conversion method Dual slope integral method
Response time 2sec.(0 ~ Max.)
Setting time 2.5 times/sec

Relay output : Relay output :


Contact capacity
250VAC 3A 1c 250VAC 3A 1c×2

Insulation resistance Min. 100MΩ(at 500VDC)


Dielectric strength 2000VAC 50/60Hz for 1 minute
Noise strength ±1kV the square wave noise(pulse width:1㎲) by the noise simulator
Mechanical 0.75mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 1 hour
Vibration
Malfunction 0.5mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 10 minutes
Mechanical 300m/s²(30G) in X, Y, Z directions for 3 times
Shock
Malfunction 100m/s²(10G) in X, Y, Z directions for 3 times

Relay Mechanical Min. 1,000,000


life cycle Malfunction Min. 1,000,000(250VAC 3A resistive load)
Ambient temperature -10 ~ +50℃(at non-freezing status)
Storage temperature -25 ~ +65℃(at non-freezing status)
Ambient humidity 35~85%RH

M4Y:Approx. 170g M4W:Approx. 317g M4W-1P:Approx. 408g M4W-2P:Approx. 424g


Weight
M5W:Approx. 317g M4M:Approx. 401g M4M-1P:Approx. 467g M4M-2P:Approx. 496g

※ "★" (Power supply)is optional.

E-31
Ampere Meter
▣Connections
(A)
Counter
lM4Y lM4M
INPUT HOLD
HI LOW

1 2 3 4 5 6 + -
(B)
8 9 10 11 12 13 14 Timer
+ -
HIGH LOW 15 INPUT HOLD 17
! SOURCE
16 18 (C)
100-240VAC 0V 110VAC 220VAC
Temp.
5VDC(Option)
1 2 3 4 5 6 7 controlle
24-70VDC(Option)

~
lM4W ~
(D)
INPUT HOLD 220VAC 110VAC 0V ! SOURCE Power option
Power
DC SMPS AC SMPS controlle
1 2 3 4 5 6 7 8 Power Power

1 2 3 1 2 3
+ - ~
HI LOW ~ Power option ~ (E)
+ - Panel
! SOURCE DC SMPS AC SMPS
24 -70 V DC 2W !
10 0-2 40 VAC
5 0/ 60 Hz 4V A meter
Power Power

6 7 8 6 7 8

~ (F)
- +
2 4-7 0V D C !
10 0-2 40 VAC lM4M1P Tacho/
5 0/6 0H z 4V A Speed/
Pulse
HI LOW meter
lM5W + -
INPUT 8 9 10 11 12 13 14
(G)
15 INPUT HOLD 17 Display
1 2 3 4 5 6 7 8 unit
NO NC
+ 16 18
-
0V 110VAC 220VAC COM
HI LOW
1 2 3 4 5 6 7
(H)
HI SET OUT Sensor
! SOURCE ~ :250VAC 3A 1c controlle
100-240VAC 50/60Hz RESISTIVE LOAD
~
24-70VDC(OP TION)
! SOURCE Power option
lM4W1P DC SMPS AC SMPS (I)
NC NO Power Power
RELAY CONTACT OUT Proximit
:250VAC 3A 1c sensor
COM
RESISTIVE LOAD 1 2 3 1 2 3
9 10 11 12 13 14 15 16 ~
+ -
HI OUT 24 -70 V DC 2W 1 00 -24 0V AC (J)
! 50 /60 Hz 5 V A
HOLD Photo
INPUT 220VAC 110VAC 0V electri c
sensor
1 2 3 4 5 6 7 8
Power option
+ - ~ DC SMPS AC SMPS lM4M2P
HI LOW
~ Power Power (K)
HI LOW
! SOURCE Pressur
6 7 8 6 7 8 + - sensor
~ 8 9 10 11 12 13 14
- +
10 0-2 40 VAC
2 4-7 0V D C !
5 0/ 60 Hz 5V A INPUT HOLD
15 17 (L)
COM Rotary
lM4W2P 16 NO NC LOW SET OUT
18 :250VAC 3A 1c encoder
RELAY CONTACT OUT RELAY CONTACT OUT 0V 110VAC 220VAC NO NC RESISTIVE LOAD
COM
:250VAC 3A 1c RESISTIVE LOAD :250VAC 3A 1c RESISTIVE LOAD
1 2 3 4 5 6 7
NC NO NC NO (M)
HI SET OUT 5-Phase
COM COM stepping
~ :250VAC 3A 1c
9 10 11 12 13 14 15 16 ~ RESISTIVE LOAD
motor &
Driver &
Controlle
LOW OUT HI OUT ! SOURCE Power option
Power option
INP UT DC SMPS AC SMPS
HOLD 220VAC 110VAC 0V Power
DC SMPS AC SMPS Power
Power Power
1 2 3 4 5 6 7 8 1 2 3 1 2 3
+ - ~
6 7 8 6 7 8
~
HI LOW + -
~ ~ 10 0-2 40 VAC
- + 24 -70 V DC 2W !
5 0/ 60 Hz 5 VA
10 0-2 40 V AC
! SOURCE 24 -70 VD C
! 5 0/ 60 Hz 5 VA

E-32
M4Y/M4W/M5W/M4M Series
▣Dimensions
lM4Y
lPanel cut-out
Min. 91
85 100
72 7 80 13
32 +- 0.6
0

Min. 40
68 +- 0.7
A 0

M4Y

Unit:mm

lM4W lM4W1P lM4W2P lM5W


AC AM PERE METER DIGITAL METER RELAY DIGITAL METER RELAY _ _ _ _ DC AMPERE MET ER
HI LO HI 1 9 9 9 HI
_ _ _ _ SET
r r r r

A A 1 0 0 0
A
_ _ _ _
LO A
r r r r 1 0 0 0 SET

r r r r

M4W-A M4W1P-X M4W2P -X M5W-A

lPanel cut-out
98 111.6
Min. 116
96 12 90 9.6

+0.6
DC AMPERE ME TER 45 -0

A Min. 52 + 0.8
92 - 0
M5W-A

Unit:mm

lM4M lM4M1P lM4M2P

HI GH HIGH
LOW

_ _ _ _

A A H I SE T A
~ S ET 1 2 3 4
~ 1 9 9 9
r r r r
~
_ _ _ _
r r r r LO SE T

1 0 0 0
r r r r

M 4M M 4 M1 P M4 M 2 P

lPanel cut-out
Min. 91
86 126

72 13 102 11

+0.7
68 -0
HI GH

+0.7
68
A -0
Min. 91
~
S ET 1 2 3 4

r r r r

M 4M 1P

Unit:mm

E-33
Ampere Meter
▣Connections ▣Proper usage
(A)
◎Measuring DC voltage lBefore you buy or use the Panel Meter, please Counter
read this catalog. The product, which is produced
I
Hi by customer's requirement, cannot be exchanged
+ or refunded. (B)
Power voltage Timer
V D.P.M lIf it displays arbitrary number even though the
- power is ON, please remove the input signal and
Load Low
check whether it displays "0000" after short the
(C)
measurement terminal. Temp.
controlle
(Fig. 1) Measuring lower than 2ADC of current
(Checking Auto Zero function)
I If it does not display "0000", please connect to our
Hi A/S center. (D)
Shunt
+ Power
Note)M5W Series does not have Auto Zero function. controlle
V 500mVDC D.P.M Power voltage
lIf it indicates 1999 or -1999 during input signal
- is ON, please turn OFF the power and check the
Low (E)
Load connection condition. Panel
meter
(Fig. 2) Measuring higher than 2ADC of current It is because the input signal is too low or high.
Note)M5W Series indicates "19999" or "-19999".
※Higher than 2ADC is using shunt for measuring current. (F)
※Basically the 2nd part of shunt value is 50mVDC. lThe specification of measurement input, which is Tacho/
Speed/
indicated in model ordering, is a standard specifi Pulse
Ex)Ordering D.P.M in case of 10ADC of measuring meter
-cation, 1:1 of measurement input and processing
ampere : Select 10ADC/50mVDC of shunt and
value.
50VDC/1000ADC of D.P.M. (G)
※Our company does not sell a shunt or C.T, so Display
unit
◎Measuring AC voltage please buy it individually.
I
lThe D.P.M for measuring AC voltage has both
Hi AVG type and RMS type separately. (H)
Sensor
Because it is produced with AVG type, please controlle
~ D.P.M Power voltage mark the model name accurately.
Ex)In case of M4Y, M4W, M4M Series(Include
Low (I)
Load setting type) Proximit
sensor
(Fig. 3) Measuring lower than 5AAC of current The model of RMS type: M4W-AAR-6
The model of AVG type: M4W-AA-6
Ex)Ordering D.P.M in case of lower than 5AAC of ※The specification will be set by sign "R". (J)
Photo
measuring ampere : ※M5W Series has RMS type only, and it is not electri c
sensor
Select M4W-AA-XX AC5A/5.00A indicated "R" on the model name.
I lIn case of D.P.M for measuring AC voltage,
Hi
please check if it is AVG type or RMS type when (K)
Pressur
comparison measuring with other company's sensor
~ C.T D.P.M Power voltage
products.
Low
Load (L)
Rotary
encoder
(Fig. 4) Measuring lower than 5AAC of current

※ If the current is higher than 5AAC, please use C.T. (M)


5-Phase
stepping
Ex)How to order D.P.M in case of 300AAC of motor &
Driver &
measuring ampere : Select 300AAC/5A of C.T Controlle

and 5AAC/300A of D.P.M.

E-34