Sunteți pe pagina 1din 33

Validate Print Help Item Rate BoQ

Tender Inviting Authority: Group General Manager /Procurement/National Capital Region Transport Corporation Ltd.

Name of Work: LOT-P3L2:-Construction of elevated viaduct from start of Modi Nagar North Station to Shatabdi Nagar Station and 5 elevated stations viz. M
roof structure of Stations] of Delhi – Ghaziabad – Meerut RRTS Corridor.

Contract No: DM/CN/COR-OF/59

Name of the
Bidder/
Bidding Firm /
Company :

PRICE SCHEDULE
(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else t

Sl. Item Description Discount Discount Amount


No.
Percentage(%)

1 0.00
Discount on Gross Amount of
Schedule A, B-1,B-2 & C
Total in Figures
Quoted Rate in Words
d.

ar Station and 5 elevated stations viz. Modi Nagar North, Meerut South, Partapur, Rithani& Shatabdi Nagar [Excluding Architectural Finishing & Pre-engineered ste

PRICE SCHEDULE
after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )

Total Amount of Schedule A, B-1,B-2 & C TOTAL AMOUNT AFTER


DISCOUNT IN INR

0.00 0.00

0.00
#VALUE!
r [Excluding Architectural Finishing & Pre-engineered steel

d to enter the Bidder Name and Values only )

TOTAL AMOUNT AFTER DISCOUNT


IN INR In Words

#VALUE!

#VALUE!
Validate Print Help Item Rate BoQ
Tender Inviting Authority: Group General Manager /Procurement/National Capital Region Transport Corporation Ltd.

Name of Work: LOT-P3L2:-Construction of elevated viaduct from start of Modi Nagar North Station to Shatabdi Nagar Station and 5 elevated stations viz. M
roof structure of Stations] of Delhi – Ghaziabad – Meerut RRTS Corridor.

Contract No: DM/CN/COR-OF/59

Name of the
Bidder/
Bidding Firm /
Company :

PRICE SCHEDULE
(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else t

Sl. Item Description Estimated Rate Excess(+)/Less(-)/At Par


No.

1 10474475686

Schedule-A: Structural Works (Viaduct & Stations)

2 407606529

Schedule-B1: NDSR
3 60000000
Schedule-B2: DSR 2018 Items

4 35000000
Schedule-C: Shifting / Rearranging of electrical,
Telecom and civil Utilities - Rate Only (Please
Refer BOQ Preamble Para. No. 1.4)

Total in Figures

Quoted Rate in Words


evated stations viz. Modi Nagar North, Meerut South, Partapur, Rithani& Shatabdi Nagar [Excluding Architectural Finishing & Pre-engineered steel

ICE SCHEDULE
vent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )

Percentage Quoted by TOTAL AMOUNT TOTAL AMOUNT


Bidder In Words

0.00 #VALUE!

0.00 #VALUE!
0.00 #VALUE!

0.00 #VALUE!

0.00 #VALUE!

#VALUE!
Preamble to Bill of Quantities
S.No
1 GENERAL

In the Bill of Quantities (BOQ) brief description of various items has been given. The same shall be read in conjunction with Good for Construction
Drawings, Technical Specifications, Employer’s Requirements, Instructions to Bidders (ITB), Conditions of Contract (GCC/PCC), Notice Inviting Tender,
1.1 Annexures and Addendums, if any. In case of ambiguity of requirement, most stringent requirement shall be complied with in general, however, Engineer’s
decision shall be final and binding on the Contractor. The execution of various items of works contained in the BOQ shall be done in accordance with the
relevant technical specifications and Employers Requirements.

1.2 Schedule “A“ of the BOQ comprises of various items of work for structural works of elevated viaduct and stations. The bidder is required to quote a flat
percentage above/below/at par with respect to the total amount for this Schedule “A “.

1.3 Schedule “B1” (NDSR Items) and Schedule “B2” (DSR Items) of the BOQ comprises of various general items for elevated viaduct and stations. The Schedule
“B2” also includes a lumpsum provision of Rs 4,89,04,961/- (Four Crore Eighty Nine Lakh Four Thousand Sixty one) for execution of various items as
per DSR-2018. The bidder is required to quote a flat percentage above/below/at par with respect to the total amount for these Schedules “B1“ & “B2" .

Schedule “C“ of the BOQ comprises of various items related to shifting/relocation /modification of various electrical, telecom and civil utilities, which are
infringing with the permanent works. In this schedule only, schedule rates for various items have been specified without any quantities for any of the items.
1.4 However total amount for this schedule has been specified. The bidder is required to quote a flat percentage above/below/at par with respect to the total
amount for this Schedule “ C “.During execution of works, these unit rates for individual items, after applying the accepted percentage rate shall be adopted
for working out the payable amounts for the quantities of various items of work executed by the Contractor.

The quantities for various items provided in the BOQ are estimated quantities and are given to provide a common basis for Bidding. During the execution of
1.5 works, the same may vary based upon “Good for Construction” (GFC) drawings issued by the Engineer and as per the site conditions. The basis of
payment will be the actual quantities of work executed and accepted by the Engineer or quantities as per the GFC drawings whichever is less and shall be
paid/valued as per the accepted rates.

The quoted rates for various items are for completed and finished items of work complete in all respects. It will be deemed to include all the cost involved in
the execution of the items and shall include all the applicable taxes and duties, royalties, cess, overheads, profit etc except Goods and Services Tax (GST)
(Except Schedule B-2 (DSR Items as per DSR-2018 ) which are already inclusive of GST and Bidders shall required to consider this aspect while quoting %
1.6 above /below/at par for Schedule B2). It shall include all general risks, liabilities and obligations set out or implied in the contract and including remedy of
any defects during the Defect Liability Period, unless otherwise provided in the Contract. The whole cost of complying with the provisions of the Contract
shall be deemed to have been included in the quoted rates. Over and above the cost as per the quoted rates, GST shall be paid as per the prevailing tariff
on submission of invoices/bills as per the prevailing rules and the provisions in the bid document.

Bidder may please note that to perform this contract, nothing extra shall be payable on account of field constraints, non-availability of uninterrupted front,
1.7 cost of project management, monitoring, coordination and supervision, cost of adhering to quality requirements (QA/QC), cost of adhering to SHE
requirements, cost of preparing drawings and documents, as-built records and documentation, preparation of detailed scheme for taking necessary
clearance and approval from the concerned authority and other local bodies etc.

1.8 Income Tax and any other statutory taxes to be deducted at source will be deducted by the Employer from the due payments of the contractor in
accordance with the prevailing rules in force.
1.9 The BOQ item details, method of measurement and payment terms for various items of BOQ are stipulated in Section-12, Narrative of BOQ as a part of
Technical Specifications.
Name of Work: LOT-P3L2:-Construction of elevated viaduct from start of Modi Nagar North Station to Shatabdi Nagar Station and 5 elevated stations viz. Modi Nagar North, Meerut South, Partapur, Rithani& Shatabdi Nagar
[Excluding Architectural Finishing & Pre-engineered steel roof structure of Stations] of Delhi – Ghaziabad – Meerut RRTS Corridor.

SCHEDULE-A

Item no. Brief Description of item of work Unit Est. Qty Unit Rate BoQ Amount

1 2 3 4 5 6
P01 FOUNDATIONS
1.1 Providing and installing RCC M40/20, Cast-in-situ vertical bored piles
i For 600mm dia RM 800 6223.6350 4978908.00
i(a) Extra over rate of Item (i) above for drilling and Socketing in rock (UCS from 12.5MPa to 50MPa) RM 30 5187.3998 155621.99
i(b) Extra over rate of Item (i) above for drilling and Socketing in rock (UCS less than 12.5MPa) RM 20 4322.9369 86458.74
ii For 800mm dia RM 800 9479.7450 7583796.00
ii(a) Extra over rate of Item (ii) above for drilling and Socketing in rock (UCS from 12.5MPa to 50MPa) RM 30 7901.3675 237041.03
ii(b) Extra over rate of Item (ii) above for drilling and Socketing in rock (UCS less than 12.5MPa) RM 20 6584.6309 131692.62
iii For 1000mm dia RM 4800 12588.8400 60426432.00
iii(a) Extra over rate of Item (iii) above for drilling and Socketing in rock (UCS from 12.5MPa to 50MPa) RM 30 10492.5150 314775.45
iii(b) Extra over rate of Item (iii) above for drilling and Socketing in rock (UCS less than 12.5MPa) RM 20 8744.6700 174893.40
iv For 1200mm dia RM 65050 17309.6550 1125993057.75
iv(a) Extra over rate of Item (iv) above for drilling and Socketing in rock (UCS from 12.5MPa to 50MPa) RM 30 10492.5150 314775.45
iv(b) Extra over rate of Item (iv) above for drilling and Socketing in rock (UCS less than 12.5MPa) RM 30 8744.6700 262340.10
v For 1500mm dia RM 500 27045.3150 13522657.50
v(a) Extra over rate of Item (v) above for drilling and Socketing in rock (UCS from 12.5MPa to 50MPa) RM 10 13666.9500 136669.50
v(b) Extra over rate of Item (v) above for drilling and Socketing in rock (UCS less than 12.5MPa) RM 10 16400.3400 164003.40
vi) Extra over rates for all sub-items of item no.1.1 for using M50/20 concrete Cum 1000 605.4840 605484.00
1.2 Providing and fixing permanent Mild Steel Liner for Piles of various diameters as per item no.1.1 above MT 450 92989.7100 41845369.50
1.3 Carrying out initial vertical load tests on Piles of various diameters 0.00
i 1500 mm dia pile (3 times the theoretical design vertical load capacity upto 800t ) Number 1 3192414.3900 3192414.39
ii 1200 mm dia pile (3 times the theoretical design vertical load capacity upto 700t ) Number 2 2046416.1300 4092832.26
iii 1000 mm dia pile (3 times the theoretical design vertical load capacity upto 600t ) Number 2 1574171.2800 3148342.56
iv 800 mm dia pile (3 times the theoretical design vertical load capacity upto 400t) Number 1 1256112.4950 1256112.50
v 600 mm dia pile (3 times the theoretical design vertical load capacity upto 300t ) Number 1 1256112.4950 1256112.50
1.4 Carrying out initial lateral load tests on Piles 0.00
i 1500 mm dia pile (3 times the theoretical design vertical load capacity upto 30t ) Number 1 245569.5000 245569.50
ii 1200 mm dia pile (3 times the theoretical design lateral load capacity upto 30t ) Number 2 157414.9500 314829.90
iii 1000 mm dia pile (3 times the theoretical design lateral load capacity upto 25t ) Number 2 87452.1450 174904.29
iv 800 mm dia pile (3 times the theoretical design lateral load capacity upto 20t ) Number 1 51177.5550 51177.56
v 600 mm dia pile (3 times the theoretical design lateral load capacity upto 15t ) Number 1 51177.5550 51177.56
1.5 Carrying out static routine vertical load tests on Piles 0.00
i 1500 mm dia pile (1.5 times the theoretical design vertical load capacity upto 700t.) Number 2 1418852.6550 2837705.31
ii 1200 mm dia pile (1.5 times the theoretical design vertical load capacity upto 700t.) Number 22 909521.9100 20009482.02
iii 1000 mm dia pile (1.5 times the theoretical design vertical load capacity upto 500t.) Number 5 699628.0500 3498140.25
iv 800 mm dia pile (1.5 times the theoretical design vertical load capacity upto 400t.) Number 2 558270.4050 1116540.81
v 600 mm dia pile (1.5 times the theoretical design vertical load capacity upto 300t.) Number 2 558270.4050 1116540.81
1.6 Carrying out dynamic routine vertical load tests 0.00
i 1500 mm dia pile (1.5 times the theoretical design vertical load capacity upto 700t.) Number 2 545714.2350 1091428.47
ii 1200 mm dia pile (1.5 times the theoretical design vertical load capacity upto 700t.) Number 22 349814.0250 7695908.55
iii 1000 mm dia pile (1.5 times the theoretical design vertical load capacity upto 500t.) Number 5 349814.0250 1749070.13
iv 800 mm dia pile (1.5 times the theoretical design vertical load capacity upto 400t.) Number 2 279154.2600 558308.52
v 600 mm dia pile (1.5 times the theoretical design vertical load capacity upto 300t.) Number 2 279154.2600 558308.52
1.7 Carrying out static routine lateral load tests 0.00
i 1500 mm dia pile (1.5 times the theoretical design lateral load capacity upto 30t ) Number 2 245569.5000 491139.00
ii 1200 mm dia pile (1.5 times the theoretical design lateral load capacity upto 30t ) Number 22 157414.9500 3463128.90
iii 1000 mm dia pile (1.5 times the theoretical design lateral load capacity upto 25t ) Number 5 87452.1450 437260.73
Item no. Brief Description of item of work Unit Est. Qty Unit Rate BoQ Amount

iv 800 mm dia pile (1.5 times the theoretical design lateral load capacity upto20t ) Number 2 51172.1100 102344.22
v 600 mm dia pile (1.5 times the theoretical design lateral load capacity upto15t ) Number 2 51172.1100 102344.22
1.8 Non destructive integrity testing of cast in situ piles of 1500/1200/1000/800/600 mm Dia Number 1900 3495.6900 6641811.00
1.9 Integrity pile test of cast in situ piles of 1500/1200/1000/800/600 mm Dia using cross hole sonic logging Number 700 5276.2050 3693343.50
1.10 Providing and laying M15/20 grade plain cement concrete for levelling coarse at various locations Cum 1900.00 5368.7700 10200663.00
Providing and laying M40/20 grade reinforced cement concrete for pile caps including earthwork and backfilling with
1.11(a)
excavated materials
Cum 39650.00 7421.5350 294263862.75
1.11(b) Extra over rate of item no.1.11(a) above for back filling with fine sand Cum 2000.00 724.1900 1448380.00
Providing and laying M 40/20 concrete for open foundations,base slabs,retaining wall,bottom slabs etc including earth work
1.12(a)
in excavation and backfilling with excavated material
Cum 1800 7933.3650 14280057.00

1..12(b) Extra over rate of item no.1.12 (a)above for back filling with fine sand Cum 450 724.1900 325885.50
Excavating trial pits of size 5 m x 1 m upto bottom of pile cap at pile cap locations in all types of strata to ascertain underground
1.13
utilities
Numbers 650 1165.2300 757399.50
1.14 Carrying out Ground Penetrating Radar (GPR) survey to locate underground utilties in grid of 5 m x 5 m upto 6 m depth Sqm 1000 141.5700 141570.00
1.15 Boring 100mm Dia borehole, 5m deep at pile locations to find out underground utilities RM 12150 921.78405 11199676.21
Sub Total - Foundations: 1658497748.37
P02 IN-SITU CONCRETE WORKS
2.1 M40/20 grade cement concrete for RCC crash barriers Cum 2470.00 8581.3200 21195860.40
2.2 M55/20 concrete for Viaduct & Station piers Cum 31050.00 10078.6950 312943479.75
2.3 M 55/20 concrete for Portal girder Cum 1500 10078.6950 15118042.50
2.4 M 55/20 concrete for Deck Slab over RCC I-Girders, Composite Steel Girders and Cross Girders Cum 11500 10078.6950 115904992.50
2.5 M 55/20 concrete for cantilever pier cap/Normal pier cap for viaduct Cum 10550 10078.6950 106330232.25
2.6 M 55/20 concrete for Pedestals and Shear Key/Seismic Stopper Cum 1450.00 10078.6950 14614107.75
2.7 Extra over rates of item nos. 2.2 to 2.6 above for using M60/20 concrete instead of M55/20 concrete Cum 11200.00 1437.4800 16099776.00
2.8 Extra over the rates of item nos.2.2 to 2.6 above for using Micro-silica in M55/20 or M60/20 grades of concrete Kg 251000.00 27.2250 6833475.00
M 40/20 concrete for structural elements at all levels like floor slabs, track slabs, chajja slabs, floor beams, cross beams, cantiliver
2.9(a)
beams, inverted beams, gutter beams, shafts, walls, stair case slab including steps, sills, lintels, copings, pits etc.
Cum 13500 8581.3200 115847820.00

2.9(b) deduction from the rate of item no.2.9 (a)above for using M35/20 concrete instead of M40/20 concrete Cum 1000 -125.2350 -125235.00
2.9(c ) deduction from the rate of item no.2.9 (a)above for using M30/20 concrete instead of M40/20 concrete Cum 1000 -255.9150 -255915.00
Sub Total - In situ Concrete Works: 724506636.15
P03 PRECAST CONCRETE
3.1 M55/20 concrete for various types of pre-cast components
i Precast Segmental Box Girders Cum 108550 11521.6200 1250671851.00
ii #REF! Cum 31900 11096.9100 353991429.00
iii #REF! Cum 11500 11521.6200 132498630.00
3.1(a) Extra over the rates of item nos.3.1(i) ,(ii) & (iii) above for providing M60/20 grade of concrete instead of M55/20 grade of concrete Cum 30400 560.8350 17049384.00
3.2 Transporting and launching /erecting various precast components at the site 0.0000 0.00
i Precast Segmental Box Girders including installation of spherical / POT PTFE bearings MT 271300 2014.6500 546574545.00
ii Precast I Girders MT 79750 1807.7400 144167265.00
iii Precast Pier Caps MT 28750 1807.7400 51972525.00
3.3 Static Load Test 0.00
ii Segmental Box Girder span up to max. load 600 MT Number 5 392246.9100 1961234.55
iv I-Girder span up to max. load 600 MT Number 7 392246.9100 2745728.37
vi Steel composite girder span up to max. load 1800 MT Number 2 1176751.6200 2353503.24
3.4 Precast concrete Parapet of M40/20 grade for cross-over structures Cum 3480 11292.9300 39299396.40
“Extra over item 3.4 for providing and mixing multi dimensional graded fibrillated (interconnected bundles of fibres that open up
during the mixing process) 100% virgin polypropylene fibres in the concrete @ the rate of 0.9 kg of fibres per cum of concrete.
3.5
Fibrillated polypropylene fibres shall have a specific gravity of 0.91 and shall be manufactured to comply with EN 14889–2:2006 class
Cum 3480 451.9350 1572733.80
Ib and ASTM C 1116-97 Type III
Item no. Brief Description of item of work Unit Est. Qty Unit Rate BoQ Amount

3.6 Transportation, erection & installation of precast parapets for cross-over structures MT 8700 1583.4060 13775632.20

3.7 Manufacture and installation of pre-cast cable trough cover slabs with M25/10 RCC Cum 750.00 11548.8450 8661633.75
Sub Total - Precast Concrete Works: 2567295491.31
P04 REINFORCING & PRESTRESSING STEEL
4.1 Providing and installing TMT reinforcement steel MT 51800 67833.8100 3513791358.00
4.2 Providing and installing Pre/Post stressed Steel and other components 0.00
i (i) HT Strands MT 7500 146573.9550 1099304662.50
ii (ii) Corrugated HDPE duct - 107mm ID RM 348250 250.4700 87226177.50
iii (iii) Corrugated HDPE duct - 86mm ID RM 37100.00 185.1300 6868323.00
iv (iv) Anchorages for 19K15 cable. Number 23600.00 10579.6350 249679386.00
v (v) Anchorages for 12K15 cable. Number 3300 7677.4500 25335585.00
4.3 Providing and installing welded wire mesh MT 20 89842.5000 1796850.00
Sub Total - Reinforcing & Structural Steel: 4984002342.00
P05 STRUCTURAL STEEL
5.1 Supply, fabrication and erection of fabricated steel girder MT 1550 140644.3500 217998742.50
5.2 Supply, fabrication and erection of launching nose,addiitonal temporary strengthening of superstrucutre MT 775 47916.0000 37134900.00
5.3 Supplying, fabricating and erection of miscellaneous structural steel components at various locations 0.00
i Steel platform for emergency evacuation for cross-over structures MT 25 102382.3350 2559558.38
ii Steel inserts for cable trays , cable tray brackets, connection of OHE mast, other steel brackets etc. MT 150 119446.9650 17917044.75
iii Steel hand rails, inserts, plates with welded hold fasts for walk-way, insert plates with welded hold-fasts, internal threaded sleeves etc MT 10 110920.0950 1109200.95
iv Straight /tapered steel plate MT 100 102382.3350 10238233.50
Sub Total - Structural Steel: 286957680.08
P06 BEARINGS
Supplying , transporation, lifting and fixing in position true in line and level elastomeric bearings corfirming to IRC:83 (Part II), Section
6.1
IX complete
Cubic-cm 2003400 1.5246 3054383.64
Sub Total - Bearings: 3054383.64
P07 BRICKWORK
7.1 Providing and fixing precast cement concrete solid block 1:1.5:3(1 cement,1.5 coarse aggregate :3 graded stone aggregate) Cum 3000 11053.3500 33160050.00

7.2 Brickwork with common burnt clay FPS (non-modular) bricks of class designation 7.5 in foundation & plinth in cement mortar 1:6 Cum 800 5172.7500 4138200.00

Brickwork with common burnt clay FPS (non-modular) bricks of class designation 7.5 in super structure above plinth level in cement
7.3 Cum 800 6082.0650 4865652.00
mortar 1:6
Half brickwork with common burnt clay FPS (non-modular) bricks of class designation 7.5 in super structure above plinth level in
7.4 Sqm 600 745.9650 447579.00
cement mortar 1:4
7.5 Extra for providing and placing 2 nos 6 mm dia MS bars at every third course of half brick masonry Sqm 600 59.8950 35937.00
Brickwork with common burnt clay machine moulded perforated bricks of class designation12.5 in superstructure aboe plinth level
7.6 Cum 20 5978.6100 119572.20
upto all floor levels in cement mortar 1:6
Sub Total - Brickwork: 42766990.20
P08 CORROSION PREVENTION
Supplying ,mixing and addting Bipolar Concrete Penetrating Corrosion Inhibiting Admixture(CPCIA) in concretes of all grades (except
8.1 Kg 685600 157.9050 108259668.00
plain cement concrete)
Sub Total - Corrosion Prevention: 108259668.00
P09 MISCELLENEOUS ITEMS
DRAINAGE WORK
Providing & fixing of HDPE corrugated double wall rain water pipes of the following sizes in pier cap and down take pipes, bends,
9.1
couplers, upper receiving caps (hot dipped galvanised @650 g/m2 steel) etc. up to bottom of pier
i 100 mm Dia RM 250 413.8200 103455.00
ii 150 mm Dia RM 350 664.2900 232501.50
iii 200 mm Dia RM 7550 1023.6600 7728633.00
Item no. Brief Description of item of work Unit Est. Qty Unit Rate BoQ Amount

iv Upper receiving caps for 100 mm Dia Number 10 1023.6600 10236.60


v Upper receiving caps for 150 mm Dia Number 10 1023.6600 10236.60
vi Upper receiving caps for 200 mm Dia Number 425 1023.6600 435055.50
Sub Total - Drainage Work: 8520118.20
P-10 EXPANSION JOINTS
Providing and installing single strip seal joint conforming to latest revisions of MORTH circulars including provision of edge beams at
10.1 RM 2900 8445.1950 24491065.50
end edges of precast diaphragm segments and cast-in- situ unit.
Providing and installing Omega (W) joint conforming to IRC 83 - part II including casting of cast-in-situ plinth at the edge of deck for
10.2 RM 4200 5276.2050 22160061.00
fixing joint
10.3 Providing and fixing sheet covering over expansion joint with stainless steel sunken head screws as per GFC drawing
i Aluminum fluted strips 3.15mm thick and 150mm wide RM 600 326.7000 196020.00
ii Aluminum fluted strips 3.15mm thick and 200mm wide RM 600 457.3800 274428.00
Providing and installing in position building expansion joint at floor level between platform level slab,concourse level slab or at
10.4 RM 450 9496.0800 4273236.00
locations shown in the GFC drawings
10.5 Polysulphide Sealant
Providing and applying Polysulphide sealant for 25mm gap including back up material in the form of round shape polyethylene form
i RM 300 566.2800 169884.00
at both faces of expansion joint in ramp portion
Providing and applying Polysulphide sealant for 50 mm gap in expansion joint including back up material in the form of round shape
ii RM 1000 1377.5850 1377585.00
polyethylene form at both faces of expansion joint in parapet
Sub Total - Expansion Joints: 52942279.50
P11 NOISE BARRIERS
11.1 Providing and installing polycarbonate noise barrier with all fixtures Sqm 1500 13612.5000 20418750.00
11.2 Providing and installing metallic noise barrier with all fixtures Sqm 100 11668.6350 1166863.50
Sub Total - Noise Barriers: 21585613.50
P12 MISCELLANEOUS WORKS
Supplying & Fixing GI Expansion Fasteners, of the following sizes and approximate exposed length 300mm, of approved make
12.1
including testing for fixing into already constructed RCC structure
i 12 mm Dia Number 800 217.8000 174240.00
ii 16 mm Dia Number 800 577.1700 461736.00
iii 20 mm Dia Number 100 1154.3400 115434.00
Supplying & Fixing Rebar Fasteners, of the following sizes and approximate exposed length 300mm, of approved make including
12.2
testing for fixing into already constructed RCC structure
i 8 mm Dia Number 400 163.3500 65340.00
ii 12 mm Dia Number 1500 381.1500 571725.00
iii 16 mm Dia Number 700 1192.4550 834718.50
Supplying and fixing in position, holding down bolts of various sizes and lengths including making of pockets in foundations, column
12.3 MT 25 142620.8850 3565522.13
heads, beams etc.
12.4 Supplying, pouring and packing non-shrink grout for grouting of holding down bolts of columns and under base plates etc. Cum 150 61827.9750 9274196.25
Providing, fabricating to required profile and shape, transporting, erecting and fixing in position MS members made of built-up
12.5 sections/rolled or hollow structural steel sections to be used as fixtures / supports / hangers / any additional structural connections for MT 10 102382.3350 1023823.35
signage etc. for system/roofing contractors at any location
Sub Total - Miscellaneous Works: 16086735.23
TOTAL FOR SCHEDULE-A 10474475686.18
Name of Work: LOT-P3L2:-Construction of elevated viaduct from start of Modi Nagar North Station to Shatabdi Nagar Station and 5 elevated stations viz. Modi Nagar North,
Meerut South, Partapur, Rithani& Shatabdi Nagar [Excluding Architectural Finishing & Pre-engineered steel roof structure of Stations] of Delhi – Ghaziabad – Meerut RRTS
Corridor.

SCHEDULE-B1 NSDR Items


Sl.
Item Description Unit Est. Qty Unit Rate BoQ Amount
No.
1 2 3 4 5 6
G01 TEMPORARY BARRICADING WORK
1.1 Providing temporary barricade of the following heights and arrangement for traffic diversions
i 2.0 m high RM 30000 2080.7100 62421300
ii 1.0 m high RM 2000 1037.6100 2075220
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of
1.2 corrugation for 3m high barricading for casting yard (The frame work for sheet fixing will be paid
extra as per DSR2018/10.1 item).

i Baricading for the Contractors casting yard with pre-coated galvanised iron profile sheets Sqm 2100 603.9000 1268190
Sub-total-G01-Temporary barricading 65764710
G02 REMOVAL OF TREES
Cutting, Removal, transporting, disposal of trees by handing over to the concerned department
as per the instruction of Engineer of the following girth (measured at height of 1.0M above
2.1
ground level) including excavation, backfilling and levelling off the ground as directed by the
Engineer
i Up to and including 30 cm Girth Number 50 148.2300 7411.5
ii Beyond 30 cm Girth up to and including 50 cm Girth Number 50 170.1900 8509.5
iii Beyond 50 cm Girth up to and including 75 cm Girth Number 50 642.3300 32116.5
Removal and transplanting trees at approved site (within 10 km lead) of the following girth
2.2 (measured at height of 1.0M above ground level) including excavation, backfilling and levelling
off the ground as directed by the Engineer
i Up to and including 30 cm Girth Number 50 9799.6500 489982.5
ii Beyond 30 cm Girth up to and including 50 cm Girth Number 50 15196.3200 759816
iii Beyond 50 cm Girth up to and including 75 cm Girth Number 50 24529.3200 1226466
2.3 Plantation of new saplings Number 10000 93.3300 933300
Sub-total-G02-Removal of Trees 3457602
G03 TRAFFIC MANAGEMENT
Providing & fixing of retro-reflective traffic sign boards (as per IRC recommendations and ISI
3.1
approved) as per directions of the Engineer.
Sqm 1200 10529.8200 12635784
Providing and fixing and maintaining the following traffic aids during the execution of works,
3.2
refixing of the same as required as per directions of the Engineer.
i Road delineator Each 600 3233.6100 1940166
Sl.
Item Description Unit Est. Qty Unit Rate BoQ Amount
No.
ii Portable Signages Each 400 6577.0200 2630808
iii Reflective lights Each 500 2750.4900 1375245
iv Traffic cones Each 1000 2316.7800 2316780
Deployment of adequate manpower round the clock in shifts of 8 hrs for the management of
3.3 traffic in intersection, roadway influenced by the exectuin of works by the contractor and traffic
diversions at various locations as per the deployment schedule approved by the Engineer.

i Incharge Shifts 2200 549.0000 1207800


ii Supervisor Shifts 15000 450.1800 6752700
iii Traffic Marshals / Guards Shifts 64000 411.7500 26352000
Sub-total-G03-Traffic Management 55211283
G04 SITE ACCOMMODATION FOR THE ENGINEER
Providing and maintaining fully furnished site offices for Engineer at four locations (100 sq.m.
Per sqm of
4.1 carpet area each location) throughout the contract period and till the 30 days beyond the issue
carpet area
400 9722.7900 3889116
of Taking Over Certificate for the entire work.
Sub-total-G04-Site Accommodation for the Engineer 3889116
G05 PHOTOGRAPHIC AND VIDEOGRAPHIC PROGRESS REPORTS
5.1 Submission of Set of colour photographs depicting the progress of works Per set 30 2750.4900 82514.7
Submisson of sets of Video DVDs to depict progress of works at monthly intervals or as
5.2
instructed by the Engineer.
Per set 30 10321.2000 309636
Submission of sets of Video DVDs with commentary of entire project comprising of every
5.3
activities starting from commencement of work to the end of the work
Per set 1 23771.7000 23771.7
Sub-total-G05-Photography 415922.4
G06 ROAD WORKS
6.1 Construction of flexible pavement as per the GFC drawings Sqm 10000 4194.3600 41943600
6.2 M30/20 grade cement concrete for median cum 12000 8325.4050 99904860
6.3 Providing and installing TMT reinforcement steel of FE-500D grade MT 1080 67833.8100 73260514.8
Construction of median and Island above road level with approved material brought from
6.4
borrow areas to be arranged by the contractor
Cum 45000 334.8900 15070050
6.5 Fabricatinon and installaiton of Tubular Steel Railing RM 1600 1762.2900 2819664
Sub-total-G06-Road Works 232998688.8
G07 SURVEYING

7.1 Detailed survey work along the corridor Running Km 15 43371.0000 650565
Sub Total - Surveying: 650565
G08 GEOTECHNICAL WORKS
Drilling of 150 mm dia bore holes in all types of soils and soft rocks conducting stipulated tests
8.1
and submission of reports
RM 500 1202.3100 601155
Sl.
Item Description Unit Est. Qty Unit Rate BoQ Amount
No.
Drilling of Nx size bore holes in all kinds of hard rocks ,conducting stipulated tests and
8.2
submission of reports
RM 300 3491.6400 1047492
Sub Total - Geo Technical Investigation: 1648647
G09 RAIN WATER HARVESTING
9.1 Construction of rainwater harvesting wells in stations Each 10 169157.8800 1691578.8
9.2 Construction of rain water harvesting well in viaduct with connections Each 212 116374.4500 24671383.4
Sub Total - Rain Water Harvesting: 26362962.2
G10 WATER SUPPLY/DRAINAGE SYSTEM
WATER PUMP SETS
10.1 Providing,fixing,testing and commissioning of vertical in line type pump sets of various capcity
i Filter Feed Water Pump sets, 150 Litre per minute and 30 m water head Each 20 65320.0200 1306400.4
ii Treated Water Pump sets, 150 Litre per minute and 50 m water head Each 20 79769.7000 1595394
iii Water Transfer Pump sets, 200 Litre per minute and 50 m water head Each 20 74060.1000 1481202
DRAINAGE PUMP SETS
Providing fixing and commissioning non clog type mono block sumersible Drainage pump set of
10.2
capacity 300 Litre per minute and 10 m water head
Each 20 38935.0800 778701.6
BORING OF TUBEWELLS
10.3 Construction of borewells
i Supplying and filling pea gravel filter fill between bore and pipe assembliey Cum 100 2091.6900 209169
Cleaning & Developing of borewell by air compressor for atleast 60 hrs. And conduting yield
ii
tests as per IS-2800 Part-III
Hrs. 600 301.9500 181170
iii Testing water samples from the well for biological and chemical contents Each 40 13066.2000 522648
BORE WELL PUMP SETS
Providing and fixing single/multistage submursible tubewell pump sets of capacity 200 Litre per
10.4
minute, 100m water head, 5.0 HP
Number 10 25956.7200 259567.2
LEVEL CONTROLLERS IN UNDERGROUND WATER TANKS
Providing and fixing Transistorised liquid level controllers to auto start pumps based on water
10.5
levels in tanks
i For Filter Feed Pumps Set 5 18166.4100 90832.05
ii For Treated Water Pumps Set 10 18166.4100 181664.1
iii For Water Transfer pumps Set 5 18166.4100 90832.05
CAST IRON BUTTERFLY VALVES
10.6 Providing and fixing C.I. Wafer Type Butterfly Valves conforming to PN 10/13095
i 50 mm dia Each 20 2552.8500 51057
ii 65 mm dia Each 10 3288.5100 32885.1
iii 80 mm dia Each 10 3892.4100 38924.1
iv 100 mm dia Each 5 4457.8800 22289.4
CAST IRON Y TYPE STRAINER
Sl.
Item Description Unit Est. Qty Unit Rate BoQ Amount
No.
10.7 Providing and fixing CI double flanged "Y" type strainer of the following sizes
i 100 mm dia Each 10 8394.2100 83942.1
MILD STEEL PIPE “U” VENTS
10.8 Providing and fixing MS vent "U" type pipe complete
i 100 mm dia Each 20 2766.9600 55339.2
INTEGRATED WATER SYSTEM CONTROL PANEL
Design, Manufacture, Supply, Installation, Testing & Commissioning of integrated cubicle type,
10.9
extensible type control panel as per specifications
Set 5 272529.0900 1362645.45
Sub Total -G-10-Water supply/drainage system 8344662.75
G11 POWER CABLES & FIXTURES
11.1 Supplying and laying the PVC insulated and sheathed XLPE armoured cables
i 3 core 4sqmm RM 300 120.7800 36234
ii 3 core 6sqmm RM 300 148.2300 44469
CABLE TRAYS
11.2 Fabricating and installing following size of perforated MS cable trays
i 150mm widthx50mm depthx1.6mm thickness RM 150 301.9500 45292.5
Sub Total -G-11-Power Cables & Fixtures 125995.5
G12 PACKAGED SEWAGE TREATMENT PLANT
Packaged Sewage treatment plant as per Employer's requirement of capacity 20 Kilolitre per
12.1
Day
Each 5 1747274.8500 8736374.25
Sub Total -G12- Sewage Treatment Plant: 8736374.25
TOTAL FOR SCHEDULE-B 407606528.9
Name of Work: LOT-P3L2:-Construction of elevated viaduct from start of Modi Nagar North Station to Shatabdi Nagar Station and 5 elevated stations viz. Modi Nagar North, Meerut South,
Partapur, Rithani& Shatabdi Nagar [Excluding Architectural Finishing & Pre-engineered steel roof structure of Stations] of Delhi – Ghaziabad – Meerut RRTS Corridor.

SCHEDULE-B2 : DSR 2018 Items

DSR
Sl.
2018 Item Description Unit Est. Qty Unit Rate BOQ Amount
No.
item No.

1 2 3 4 5 6 7
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and
1 10.1 Kg 83250 86.05 7,163,662.50
applying a priming coat of approved steel primer all complete.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including
collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all
23.1 -
equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90
2 metre depth below ground level.
23.1.1 All types of soil -
23.1.1.2 350 mm dia RM 900 560.3 504,270.00
23.1.2 Rocky strata including Boulders -
3
23.1.2.2 350 mm dia RM 20 1293.8 25,876.00
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including
collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all
23.2 -
equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90
4 metre & upto 150 metre depth below ground level.
23.2.1 All types of soil -
23.2.1.2 350 mm dia RM 100 664.05 66,405.00
23.2.2 Rocky strata including Boulders -
5
23.2.2.2 350 mm dia RM 20 1411.75 28,235.00
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild
steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make,
23.10 -
6 including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including
required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
23.10.3 200 mm nominal size dia having minimum wall thickness 5.40 mm RM 600 2062.05 1,237,230.00
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain
slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain
bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not
23.11 less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand -
7
and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of
Engineer -in-charge.
23.11.3 200 mm nominal size dia RM 400 2171.05 868,420.00
23.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
-
8
23.15.3 200 mm dia each 10 307.75 3,077.50
18.12 Providing and fixing G.I. pipes complete with G.I. fittings including
trenching and refilling etc.
9
18.12.6 50 mm dia nominal bore Meter 200 565.25 113,050.00
18.12.7 65mm dia nominal bore Meter 200 716.00 143,200.00
10
18.12.8 80mm dia nominal bore Meter 200 866.4 173,280.00
Misc DSR Items required for the execution of works covered in DSR 2018 but not included in Schedule A, B, & C Lump
48,904,960.67
11 sum
TOTAL FOR SCHEDULE-B2 59,231,666.67
Say 60,000,000.00
Name of Work: LOT-P3L2:-Construction of elevated viaduct from start of Modi Nagar North Station to Shatabdi Nagar Station and 5
elevated stations viz. Modi Nagar North, Meerut South, Partapur, Rithani& Shatabdi Nagar [Excluding Architectural Finishing & Pre-
engineered steel roof structure of Stations] of Delhi – Ghaziabad – Meerut RRTS Corridor.

SCHEDULE-C
Shifting/Rearranging of Utilities
Item Description Amount
Provisional sum for the cost of shifting/rearranging of utilities to be paid as per the rates detailed below

1 Annexure A: Electrical Utilities 3,000,000


2 Annexure B: Telecom.Utilities 2,000,000
3 Annexure C: Civil Utilities 30,000,000
GRAND TOTAL OF SCHEDULE-C 35,000,000

Sl. Item Description Units Unit Rate


No.

1 2 3 4
A Annexure A
1 LAYING OF PIPES BY TRENCHLESS BORING
Supply of HDPE pipe confirming to PN4 as specified the sizes given below, boring of road areas
by using trench –less method and laying of HDPE pipe properly continuously joined
63mm Mtr 545.61
75mm Mtr 630.48
110mm Mtr 727.48
160mm Mtr 1697.45
200 mm Mtr 1818.7
250mm Mtr 2182.44
2 LAYING OF PIPES BY OPEN TRENCHING METHOD
Supply of HDPE pipe confirming to PN4 as specified the sizes given below, laying of HDPE pipe
properly continuously joined, by Open Trench method of laying
63mm Mtr 363.74
75mm Mtr 484.99
110mm Mtr 645.03
160mm Mtr 727.48
200mm Mtr 848.73
250mm Mtr 982.1
Supply at the site of work of LT, PVC insulated, armoured, Aluminium conductor cables as per
IS1554/Part-I /1988 with up to date amendment & specified in the specifications of the sizes
3 given below, laying of cables in existing pipes in all types of areas normal (soil, footpath, road
etc). As directed by engineer in charge, including testing and commissioning of cables etc as
required
1.1KV PVC 4x95sqmm Mtr 691.10
1.1KV PVC 4x70sqmm Mtr 521.40
1.1KV PVC 4x25sqmm Mtr 247.30
1.1KV PVC 4x16 sqmm Mtr 186.70
1.1KV PVC 4x10 sqmm Mtr 150.60
1.1KV PVC 2x25 sqmm Mtr 151.60
1.1KV PVC 2x10sqmm Mtr 124.90
Supply at the site of work of HT, XLPE insulated, armoured, Aluminium conductor cables as per
IS-7098/Part-II /1985 with up to date amendment & specified in the specifications of the sizes
4 given below, laying of cables in existing pipes in all types of areas (normal soil, footpath, road
etc). As directed by engineer in charge, including testing and commissioning of cables etc as
required
11KV XLPE3X300 sqmm Mtr 2399.47

Supply at the site of work of HT, XLPE insulated, armoured, Aluminium conductor cables as per
IS-7098/Part-II/1985 with up to date amendment & specified in the specifications of the sizes
given below, laying of cables in trenches in all types of areas (normal soil, footpath, road etc) by
5
excavation with laying arrangement with stand cushion and brick/brick tiles or shaped RCC
cover protection as required/approved by utility owing agency at the required depth including
refilling of trenches, testing & commissioning of cables etc as required

11KV XLPE3X300 sqmm Mtr 2698.95

Supply at the site of work of LT, PVC insulated, armoured, Aluminium conductor cables as per
IS-1554/Part-I/1988 with up to date amendment & specified in the specifications of the sizes
given below, laying of cables in trenches in all types of areas (normal soil, footpath, road etc) by
6
excavation with laying arrangement with stand cushion and brick/brick tiles or shaped RCC
cover protection as required/approved by utility owing agency at the required depth including
refilling of trenches, testing &commissioning of cables etc as required

1.1KV PVC 4x95 sqmm Mtr 809.93


1.1KV PVC 4x70 sqmm Mtr 624.42
1.1KV PVC 3.5x70 sqmm Mtr 569.86
1.1KV PVC 4x25sqmm Mtr 323.73
1.1KV PVC 4x16 sqmm Mtr 258.26
1.1KV PVC 4x10 sqmm Mtr 218.24
1.1KV PVC 2x25 sqmm Mtr 219.46
1.1KV PVC 2x10 sqmm Mtr 190.36
Supply at the site of work of HT, XLPE insulated, armoured, Aluminium conductor cables as per
IS-7098/Part-II/1985 with up to date amendment & specified in the specifications of the sizes
given below, laying of additional cables in same trenches of required width in all types of areas
7 (normal soil, footpath, road etc) by excavation with laying arrangement with stand cushion and
brick/brick tiles or shaped RCC cover protection as required/approved by utility owing agency at
the required depth including refilling of trenches, testing &commissioning of cables etc as
required
11KV XLPE3X300 sqmm Mtr 2671.06
Supply at the site of work of LT, PVC insulated, armoured, Aluminium conductor cables as per
IS-1554/Part-I/1988 with up to date amendment & specified in the specifications of the sizes
given below, laying of additional cables in same trenches of required width in all types of areas
8 (normal soil, footpath, road etc) by excavation with laying arrangement with stand cushion and
brick/brick tiles or shaped RCC cover protection as required/approved by utility owing agency at
the required depth including refilling of trenches, testing & commissioning of cables etc as
required
1.1KV PVC 4x95 sqmm Mtr 788.10
1.1KV PVC 4x70 sqmm Mtr 602.60
1.1KV PVC 3.5x70sqmm Mtr 544.40
1.1KV PVC 4x25sqmm Mtr 301.90
1.1KV PVC 4x16 sqmm Mtr 236.43
1.1KV PVC 4x10 sqmm Mtr 196.42
1.1KV PVC 2x25 sqmm Mtr 197.63
1.1KV PVC 2x10sqmm Mtr 168.53
Supply at the site of work of LT, XLPE insulated, armoured, Aluminium conductor cables as per
IS-7098/Part-I /1988 with up to date amendment & specified in the specifications of the sizes
9 given below, laying of cables in existing pipes in all types of areas normal soil, footpath, road
etc).. As directed by engineer in charge, including testing and commissioning of cables etc as
required
1.1KV XLPE 3.5x240sqmm Mtr 1411.31
1.1KV XLPE 3.5x185 sqmm Mtr 1106.98
1.1KV XLPE 3.5x150sqmm Mtr 896.01
1.1KV XLPE 3.5x120 sqmm Mtr 759
1.1KV XLPE 3.5x95 sqmm Mtr 617.15
Supply at the site of work of LT, XLPE insulated, armoured, Aluminium conductor cables as per
IS-7098/Part-I/1988 with up to date amendment & specified in the specifications of the sizes
given below, laying of additional cables in same trenches of required width in all types of areas
10 (normal soil, footpath, road etc) by excavation with laying arrangement with stand cushion and
brick/brick tiles or shaped RCC cover protection as required/approved by utility owing agency at
the required depth including refilling of trenches, testing &commissioning of cables etc as
required
1.1KV XLPE 3.5x240sqmm Mtr 1583.48
1.1KV XLPE 3.5x185 sqmm Mtr 1247.63
1.1KV XLPE 3.5x150sqmm Mtr 1016.05
1.1KV XLPE 3.5x120 sqmm Mtr 863.28
1.1KV XLPE 3.5x95 sqmm Mtr 708.08
Supply at the site of work of LT, XLPE insulated, armored, Aluminium conductor cables as per
IS-7098/Part-I/1988 with up to date amendment & specified in the specifications of the sizes
given below, laying of cables in trenches in all types of areas (normal soil, footpath, road etc) by
11
excavation with laying arrangement with stand cushion and brick/brick tiles or shaped RCC
cover protection as required/approved by utility owing agency at the required depth including
refilling of trenches, testing & commissioning of cables etc as required.
1.1KV XLPE 3.5x240sqmm Mtr 1608.94
1.1KV XLPE 3.5x185 sqmm Mtr 1273.09
1.1KV XLPE 3.5x150 sqmm Mtr 1041.51
1.1KV XLPE 3.5x120 sqmm Mtr 885.1
1.1KV XLPE 3.5x95 sqmm Mtr 729.91
Supply, Making, Testing and Commissioning of Complete Straight Through Joint as Specified in
the Specification including Provision of Lugs/Ferrules for Jointing the HT/LT, XLPE/PILCA/PVC
12
insulated cables, excavation of Pits, sand Cushioning, Protective Covering Refilling of Jointing
Pit etc as Required by Utility Owing Agency of Following Sizes and Type:

11KV H.S. Type 3 x 300 sqmm Set 17859.64


LT 1.1KV cast resin comp. Type 3.5x240 Set 1933.88
LT 1.1KV cast resin comp. Type 3.5x185 Set 1581.06
LT 1.1KV cast resin comp. Type 3.5x150 Set 1541.05
LT 1.1KV cast resin comp. Type 3.5x120 Set 1481.63
LT 1.1KV cast resin comp. Type 3.5x95 Set 1018.47
LT 1.1KV cast resin comp. Type 4x95 Set 1018.47
LT 1.1KV cast resin comp. Type 4x70 Set 1018.47
LT 1.1KV cast resin comp. Type 4x25 Set 710.51
LT 1.1KV cast resin comp. Type 4x16 Set 632.91
LT 1.1KV cast resin comp. Type 4x10 Set 632.91
LT 1.1KV cast resin comp. Type2x25 Set 632.91
LT 1.1KV cast resin comp. Type 2x10 Set 544.40
LT 1.1KV cast resin comp. Type 3.5CX70 Set 1018.47
Supply, Making, testing & Commissioning of Complete Heat Shrinkable Type Indoor/Outdoor
type and end Termination as Specified in the Specifications including provision of Lugs/Ferrules
13
for Termination of XLPE insulated cable including making Hole in the Switch Board, Clamping,
Supporting complete as required by Utility owing agency of Following Sizes:

INDOOR TERMINATIONS
11 KV H.S. Type 3X300 Sq. Mm Set 6429.71
OUTDOOR TERMINATIONS
11 KV H.S. Type 3X300 Sq. Mm Set 9636.69
14 DISMANTLING (Taking Out From Ground) of Cables
Dismantling (taking out from ground) the following rating & sizes of XLPE/PILCA/PVC cables,
without damaging the cables, by excavation in all types of area (normal soil, foot-path, road etc.)
with refilling excavated trenches. This also includes handing over of dismantled cable (if not
relayed) to concerned utility owning agency
11KV Cables of all Type and Sizes above 120 Sqmm Mtr 41.22
LT Cables of all Type and Sizes 120 Sqmm and above Mtr 30.31
LT Cables of all Type and Sizes less than 120 Sqmm Mtr 25.46
Dismantling and removing existing structures, posts, etc of HT/LT lines and transportation and
15 stacking of all materials at suitable locations as per instructions including digging out loading M 50.92
and unloading on to lorries, of poles, lines and all materials without damaging the same.
Dismantling and removing existing structures, posts, etc of transformer installations and
transportation and stacking of all materials at suitable locations as per instructions including
16
digging out loading and unloading on to lorries, etc of poles, transformers, and all materials
No 6073.25
without damaging the same.
Dismantling and shifting of RMU at various locations and re- erecting, including foundation
17
works and earthing.
No 30311.68

Supply and erection of LT distribution pillar boxes over cable ducts on the sides of roads. The
box shall be fabricated out of 14 swg CRCA sheet, fully compartmentalised, common cubicle
frame work, free standing type dust and vermin proof and water proof suitable for outdoor
application(IP-65) and powder coated, with 2 nos 250A, 4 pole extra current limiting type,
isolation duty MCCB set at 200A, 35KA , as incomers, operating iduvidually with mechanical
castel key interlocking for receiving supply from the duplicate cable feeders, with 4 nos 4 pole
18
extra current limiting type, isolation duty MCCB, 125 A 25 KA as outgoings meant for
No 133367.73
connecting to individual metering panels located at consumer prmises, through cables, the
boxes shall be provided with air insulated , 250A colour coded TPN aluminium bus bars wih all
rigid interconnections and with a set of indicator lamps with suitable control fuses and duplicate
earth connections using 40 mm GI pipes and no: 6 SWG GI wire, including cost of all materials
and labour as per standard specifications and directions of utility officers

Supply and erection of LT distribution panel boards to be erected in consumer's premises. The
boards shall be fabricated out of 16swg CRCA sheet, fully compartmentalised, common cubicle
frame work, free standing type dust and vermin proof and suitable for outdoor application(IP-
65) and powder coated, with 1 nos 125A, 25KA 4 pole extra current limiting type, isolation duty
MCCB as incomer and 8nos 4 pole extra current limiting type, isolation duty MCCB, 63A ,25
19
KA as outgoings, and provision for accommodating energy meter with sealing facility . The
No 60527.57
boards shall be provided with air insulated , 125A colour coded TPN aluminium bus bars wih all
rigid interconnections and with a set of indicator lamps with suitable control fuses and duplicate
earth connections using 40 mm GI pipes and no: 6 SWG GI wire, including cost of all materials
and labour as per standard specifications and directions of utility officers

Supply and erection of ring main units, CTC type for replacing tapping DP structures of HT
circuits, and for CSS, on RCC 1:2:4 foundations using foundation bolts and giving connections,
20
etc complete including cost off all materials and labour, as per standards and directions of
No 810428.7
officers.
Supply and erection of ring main units, ADD ON type for replacing tapping DP structures of HT
21
circuits, on RCC 1:2:4 foundations.
No 256679.26

Supply, installation, Testing and commissioning of CSS (Compact


Switching Station) – 11 KV, 990 KVA, consisting of Transformer one vacuum/SF6 breaker for
transformer control, LT panel with I/C ACB, and O/G, MCCBs (8 N0s) enclosed in 2 mm thick
22
weather proof GS enclosure including construction of necessary foundation, using, foundation
No 3479780.29
bolts, etc, complying with IS 1330 and as per specifications of KS E Board, and directions of
officers.
Fitting and erecting one HT TW/RSJ/Rail Single Pole in position, including fitting cros sarm,
23 digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads to the No 680.19
ground for earthing (excluding provision of earthinging).
Fitting and erecting one HT PSC/RCC Single Pole in position, including fitting cross arm, digging
24 and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads to the ground No 1200.34
for earthing (excluding provision of earthing).
Fitting and erecting one HT 'A' type Single Pole in position, including fitting cross arm,digging
25 and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads to the ground No 1520.43
for earthing (excluding provision of earthing).
Fitting and erecting one HT Four legged 'A' type Single Pole in position including fitting cross
26 arm, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads to No 2200.63
the ground for earthing (excluding provision of earthing).

Fitting and erecting one HT Double Pole Structure using TW/RSJ/Rail pole in position including
27 fitting 2 Nos channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient No 2136.37
length of GI earthing leads to the ground for earthing (excluding provision of earthing).

Fitting and erecting one HT Double Pole Structure using PSC/RCC pole in position including
28 fitting 2 Nos channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient No 3176.66
length of GI earthing leads to the ground for earthing (excluding provision of earthing).

Fitting and erecting one HT Double Pole Structure using 'A' type pole in position including fitting
29 2 Nos channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient length of No 3816.85
GI earthing leads to the ground for earthing (excluding provision of earthing).

Fitting and providing one HT Stay for 11 kV pole, including digging and back filling pit in ordinary
30
soil.
No 494.69
Fitting and providing one Strut using HT pole, including digging and back filling pit in ordinary
31
soil.
No 600.17
Fitting and providing one HT Fly stay for 11 kV pole using HT pole, including digging and back
32 filling pits in ordinary soil drawing sufficient length of GI earth leads to the ground for earthing No 1229.44
(excluding provision of earthing).
Stringing of one km 11 kV line with ACSR Raccoon (3 conductors) after fitting insulators and
giving jumper connections including cutting removing tree branches wherever necessary and
33
conveyance of all materials (except poles) to an initial distance of 200 m from stacking place,
km 12563.58
after cutting and removing tree branches wherever necessary

Fitting 3 Nos channel cross arm, AB switch, DO fuse, LA, HT & LT connections up to OH lines,
etc. on existing DP structure, earthing the same using earth pipe, digging & back filling pit in
34
ordinary soil (upto 5 Nos), provision for one set (3 Nos) of LT fuses. excluding mounting of
No 5296.06
Transformer on plinth but including erecting up of statutory fencing around the structure.

Erecting one 100/150/160 kVA Transformer from any vehicle/Ground to existing DP and giving
35
connections(including expenses for transporting transformer in lorry from any stores to site).
No 2610.44

Erecting one 100/150/160 kVA Transformer from any vehicle/Ground to existing Plinth and
36
giving connections(including expenses for transporting transformer in from any stores to site).
No 2270.95

Erecting one 250/315/500 kVA Transformer from any vehicle/Ground to existing Plinth and
37 giving connections(including expenses for transporting transformer in lorry from any stores to No 3031.17
site).
Installing One DTR Meter with box (Normally 40x25x100 size) on existing poles and giving the
38
complete connections including conveyance of materials.
No 1340.99
Fitting one additional Fuse unit and giving connection from Transformer to fuse and fuse to LT
39
OH line.
No 122.46
40 Erecting one LT TW/RSJ/Rail Pole in position including digging & back filling pit in ordinary soil. No 420.73

41 Erecting one LT PSC/RCC Pole in position including digging & back filling pit in ordinary soil. No 740.82
42 Providing Stay for LT poles including digging & back filling pit in ordinary soil. No 334.64
43 Providing Strut using LT pole including digging and back filling pit in ordinary soil. No 372.23
44 Providing Fly stay for LT pole using LTpole including digging and back filling pit in ordinary soil. No 791.74
Stringing, shackling, fitting cross arms, insulators and binding, giving jumper connection etc
using ACSR Rabbit for Phase and ACSR weasel for Neutral, for one km LT 3 ph 4 wire line
45
including cutting removing tree branches wherever necessary and conveyance of all materials
km 11003.14
(except poles) from stacking place.
Stringing, shackling, fitting cross arms, insulators and binding, giving jumper connection etc for
one km additional conductor (ACSR Rabbit/Weasel) on existing LT line including cutting
46
removing tree branches wherever necessary and conveyance of all materials (except poles)
km 2461.31
from stacking place.
Stringing, shackling, fitting insulators (excluding fitting of cross arm) and binding, giving jumper
connection etc, for one km additional conductor (ACSR Rabbit/Weasel) on existing LT line
47
including cutting removing tree branches wherever necessary and conveyance of all materials
km 1661.08
(except poles) from stacking place.
Fitting one set (3Nos) LT lightning arrestors in three phase line and giving connections excluding
48
earthing
No 169.75

49 Supply and erecting PSC Poles in position including fittings, excavation and back filling of pits. No 3394.91
50 Providing stay for poles including cost of materials and back filling of pits etc. No 1200.34
51 Supply at site of ACSR Raccoon (6/1/4.09mm) conductor for 11 KV system,. km 58602.17
52 Supply at site of ACSR Rabbit (6/1/3.35mm) conductor for 11 KV system,. km 39445.19
53 Supply at site of ACSR Weasel (6/1/2.59mm) conductor for 11 KV system,. km 25306.61
54 Supply at site any type of LT/HT poles with fittings No. 3348.83
55 Supply at site of LT/HT, A type poles with fittings No. 17280.08
56 Supply at site of LT/HT, four legged A type lattice poles with fittings No. 68929.96
Providing earthing for poles and supports, pillarc boxes, panels, structures, transformers, etc
57 including supply of materials, excavation, giving connection, laying lead wires, etc complete No 3622.85
using 40 mm GI pipes 3 m long and GI wires of size upto No 6 SWG.

Constructing Transformer plinth of size 1.5m x 1.5m x 1.5m on 1.8m x 1.8m x 0.75m basement
inclusive of cost of all material. [Excavation 1.8m x1.8m x 0.75m, Random Rubble in CM(1:6)
58
1.8m x 1.8m x 0.75m + 1.5m x 1.5m x 1.5m, concrete(1:2:4, 20mm) 1.5m x1.5m x10cm, plaster
No. 11969.47
CM(1:3) 12mm, 1.5m x 1.5m, Pointing CM(1:3) 1.5m x 1.5m x4 sides.

B-1 Annexure B -Telecom. Utilities.


Supply & Provision of Polythene Insulated, Polythene sheathed Jelly filled (PIJF) copper
1 conductor underground Armoured telephone cable as per DOT/BSNL Specification. No-
G/CUG/01-02 Feb 96 (latest)
a) 1200/6.5 lbs (0.5 mm) Mtr 2,789
b) 800/6.5 lbs (0.5 mm) Mtr 1,879
c) 400/6.5 lbs (0.5 mm) Mtr 1,303
d) 200/6.5 lbs(0.5 mm) Mtr 636.55
e) 100/6.5 lbs (0.5 mm) Mtr 363.74
f) 50/6.5 lbs (0.5 mm) Mtr 187.93
g) 20/6.5 lbs (0.5 mm) Mtr 84.87
Supply & Provision of Polythene Insulated, Polythene sheathed Jelly filled (PIJF)
2 copper conductor underground Unarmoured telephone cable as per DOT Specification
No- G/CUG/01-02 Feb 96 (latest)
a) 1200/6.5 lbs (0.5 mm) Mtr 2,087
b) 800/6.5 lbs (0.5 mm) Mtr 1,409
c) 400/6.5 lbs (0.5 mm) Mtr 977.25
d) 200/6.5 lbs(0.5 mm) Mtr 476.5
e) 100/6.5 lbs (0.5 mm) Mtr 272.81
f) 50/6.5 lbs (0.5 mm) Mtr 140.65
g) 20/6.5 lbs (0.5 mm) Mtr 63.05
Identification for working /non working cables.This includes cutting , testing & jointing
3 pairs 2.42
etc. of different corrage at both ends & jointing of cables pair
Trenching and backfilling on footpath/cc/bitumunious dense carpeted road for identification of
4
cables ( 1.5m x 1.5 m)
Mtr 515.3
5 Trenching and backfilling on footpath/cc/bitumunious dense carpeted road ( .90m x1.0m) Mtr 206.12
6 Supply and provision of GI pipe B class (100 mm) Mtr 381.93
7 Supply and provision of Red stone slab (600x225x38) Nos. 18.19
8 Supply & Provision of jointing kit
a) TSF-vi Nos. 1,576
b) TSF-v Nos. 1,212
c) TSF-iv Nos. 848.73
d) TSF-iii Nos. 727.48
e) TSF-ii Nos. 394.05
9 Supply & Provision of Jointing material for jointing of copper cables Nos. 1151.84
10 Making Jointing pit (3mX3m) Nos. 727.48
11 Jointing of newly laid cable pairs pairs 2.42
12 laying/slewing of cables of diff. Corrage (Cu.)
a) 800 pair & above Mtr 12.12
b) Below 800 pair Mtr 6.06
13 Supply & provision of 48 Fibre Optical Fibre Cable Mtr 95.78
14 Supply & provision of 24 Fibre Optical Fibre Cable Mtr 69.11
15 Joint Enclosure 48 Fibre Nos. 836.60
16 Joint Enclosure 24 Fibre Nos. 666.86
17 Making 48 F splice Nos. 6,668.57
18 Making 24 F splice Nos. 4,849.87
19 Laying of OFC cable Mtr 12.12
20 Supply and Provision of HDPE pipe 32 mm dia (for subducting) Mtr 24.25
21 Laying of Subduct (32 mm) Mtr 6.06
22 Supply and Provision of 4 mm dia 3 strand polypropylene rope of ordinary grade Mtr 2.42
23 Erection of BSNL Telephone Poles Nos. 97.00
24 Construction of Joint Chamber for Joints and Pulling Pit Nos. 4,849.87
25 Construction of 110 mm PVC pipe cable duc
a) 48 way R Mtr. 7,274.80
b) 24 way R Mtr. 6,062.34
c) 16 way R Mtr. 5,456.10
26 Construction of Manhole for Cable Duct Nos. 133,371.37
27 Supply & provision of 110 mm HDPE PN 10 (10 Kgf) pipe through trenchless technology Mtr. 2,121.82
28 Laying of cables through moling technology ( at a depth of 1.75 m) Mtr. 375.86
29 Shifting of BSNL Pillars Job 133,371.37
B-2 Details of Duct Work
RATES FOR CABLE DUCT & MANHOLES-Non DSR items for Cable duct & Man
Holes.

Providing & laying PVC pipes, complete with sockets with cable duct in standard formation or as
specified by the Engineer-in-Charge and in alignment maintained by using spacers including
jointing with solvent cement solution but excluding the cost of PVC spacers all complete as per
1 BSNL specifications (finished length of pipes shall be measured for making payment) and the mtr. 110.33
rates includes the cost of rodding, cleaning & performing mandrel test and to pass all the checks
and tests prescribed in final acceptance testing schedule of BSNL:a) 110mm Outer Dia PVC
pipe of 2.5mm wall thickness

Providing and fixing Abs thermoplastic spacer 2.7mm thick in any colour other than black as per
2
drawing & shall ensure 50mm gap between pipes as per drawing.
a) Double ended Spacer - 4-Ways Nos. 54.56
b) Single ended Spacer - 4-Ways Nos. 52.14
Providing and fixing Abs thermoplastic expansion plug (110gm. Wt.) in ducts in any colour other
3 than black all complete as per the direction of Engineer-in-Charger and as per BSNL drawing: a) Nos. 63.05
110 mm outer dia pipe.
Providing and fixing 5mm thick (165gm.wt.) high density plastic material end caps in ducts in
4 any colour other than black all complete as per the direction of Engineer–in –Charge and as per Nos. 2.42
BSNL drawing:a) For 110mm outer dia pipe.

Providing and laying 4mm dia 3 strand polypropelene rope of ordinary grade ( as per IS:5175- One Running
5
1987) inside the pipe from manhole to manhole as per direction of Engineer-in-Charge. Meter.
2.42

Providing and laying polythene sheet of approved quality and weight not less than 1 Kg./10
Sqm. as per direction of Engineer-in-Charge. (The overlap shall not be less than 150mm
6 wherever necessary).Polythene sheet to be wrapped all-round duct i/c fixing to the sides of soil Sq. Meter 18.19
by nailing etc. all complete. (Net area of polythene sheet ex. Overlapping) shall be measured
for payment

Providing & fixing MS channel hot dip galvanized to a minimum coating wt. Of 610 gm./Square
meter of size ISMC-75 (wt. 6.80 Kg./Mtr.) including making holes of 14mm dia as desired by the
Engineer-in-Charge in both the flanges of the channel for fixing brackets and holes of 17mm dia
in the web of the channel at the required spacing for fixing the channel to the wall of the
7 manholes with the help of expandable type of 12mm dia, 65mm long stainless steel dash Nos. 611.08
fasteners and hold-in-Anchor bolt of approved size & quality complete as per the direction of
Engineer-in-charge and as per drg. The rate includes the cost of channel, dash fastners, bolts,
washers, making hole etc. and the labour involved in all the operations as stated above: a)
1600 mm long.

Providing and fixing in Manhole base slab, MS galvanized pulling eyelet of 20mm dia and
8 1000mm long, fixed in position as per direction of Engineer-in Charge and as per BSNL Nos. 135.80
Drawings.

Providing and fixing sump cover assembly consisting of cover frame and grill as per drawing.
The sump cover frame shall be manufacture red from 35x35x5mm galvanized MS angle section
and shall have clear inside opening of 300x300mm having holdfast of MS flat of size 20x4mm,
9 150mm long including welding, the cover grill shall be approved factory make and made of steel Nos. 494.69
fibre reinforced concrete of size 340x340x30mm thick and shall have 2mm thick galvanised
plate all-round. The random distributed steel fibre shall be provided @ 0.75% by volume of
concrete. The fibre shall be of medium tensile steel in accordance with IS 12592 (Pt1-1988).

Providing & Fixing precast steel fibre reinforced concrete cover and frame for M/H of 690mm.
Dia clear opening and shall be of approved factory make as per approved design & drg.
Reinforced cement concrete of grade CU.M.0 conforming to IS 456-1978 shall be used and
admixture confirming to is 9103-1979 shall be added to concrete mix. The manufacturing
process shall be as per IS 12592 (Pt. 1, 1988). The random distributed steel fibre shall be
provided at a rate of 0.75% by volume to concrete. The fibre shall be of medium tensile steel in
10
accordance with IS 12592 (Pt 1 1988). The reinforcement as shown in drg. Shall be provided in
Nos. 1658.65
the frame & cover and the same shall be welded to side lining of the cover. The galvanized MS
Plate, Flat and Hooks as shown in the drg. Shall be provided in frame and cover for sidelining
and lifting arrangement. The cover shall be able to withstand heavy duty loading conforming to
classification HD-20 circular type as per IS-1726-1990. Suitable keyhole and PMT markings
sunk cast on covers shall be made

Providing & fixing locking arrangement for Manhole as per drg. The locking arrangement shall
11 be of galvanized MS Angles, square bars, flats, plate etc. The rate includes cost of materials, Kilogram. 64.26
welding, drilling, galvanizing & labour for manufacturing and fixing to the Manhole wall etc.

Painting of Manhole code number with black or red paint over white base, in size of 100mm and
12 10mm thick at the inside surface of all the opening in Manhole as per the direction of Engineer- Nos. 53.35
in-Charge.

Providing and fixing in Manhole walls MS galvanized ladder hooks of 16mm dia and 800mm
13
long fixed in position as per the direction of Engineer-in-Charge and as per BSNL drawing.
Nos. 53.35

Providing and fixing steel work welded in built up section cable bearer for manhole/Handhole
(including GI nut and bolts) as per drawing including cutting handling upto each manhole and
fixing in position all complete as per the direction of Engineer-in-Charge in tees, angles, flats
and channels). (The end of the bolts shall be splitted into two parts and spreaded after fixing to
14
avoid reopening and welding shall be continued on both side. All the above steel sections
Kilogram. 69.11
should be hot dip galvanized confirming to IS standard with minimum thickness of galvanizing
conforming to 570gm/sqm. The wt. of section without galvanizing shall be considered for
payment.

Providing and fixing MS galvanized circular frame of 1100mm dia consisting of 75x4mm flat
including providing of 3 Nos. (150x15x6mm) MS galvanized lugs including cutting holes in RCC
15
neck, welding lugs to reinforcement and making good the holes with RCC (1:1.5:3) complete as
Nos. 663.22
per direction of Engineer-in-Charge.
Disposal of surplus excavated materials/earth/rock etc. including loading, unloading and
16 stacking all complete to the BSNL plot/dumping yard identified by the local bodies irrespective of Cu.M. 139.43
all leads & lift as directed by Engineer-in-Charge .
17 Dismantling of existing M/H & protection for existing OFC / copper cables nos. 5971.40
Dismantling of existing cable duct & handling of cable including serviceable material & disposal
18
of unserviceable materials
job 11536.62
C ANNEXURE-C
Taking out and transportation of C.I/M.S/P.S.C/H.S. pipes including dejointing and transportation
1
upto all lifts and a lead of 5km.( The Scrap shall be the property of NCRTC)

A a) upto 300mm dia pipe line Mtr 322.52


b) upto 400-600 mm dia pipe line Mtr 589.26
B for interconnection point/Y-Tee/Valve
a) upto 300mm dia Each 12158.62
b) upto 400-600 mm dia Each 31242.85
Providing and laying S&S NP-3 RCC, pipes manufactured by using sulphate resistant cement
2
including jointing with rubber ring and filling joints with cement mortar 1:2
a) 150 mm diameter Mtr 458.31
b) 250mm dia pipe Mtr 680.19
c) 300mm dia pipe Mtr 808.72
d) 400mm dia pipe Mtr 1436.77
e) 450mm dia pipe Mtr 1487.7
f) 600mm dia pipe Mtr 2286.71
g) 900mm dia pipe Mtr 4255.76
Providing and laying S&S NP-4 RCC pipes manufactured by using sulphate resistant cement
3
including jointing with rubber ring and filling joints with cement mortar 1:2
a) 600 mm dia pipe Mtr 3625.28
b) 450 mm dia pipe Mtr 2237
c) 400 mm dia pipe Mtr 1767.78
d) 300 mm dia pipe Mtr 1252.48
e) 250 mm dia pipe Mtr 718.99
Plugging of water main with baloon of adequate size by inflating with air compressor including
4
transportation of air compressor at site
a) 400 mm dia Job 15425.01
b) 600 mm dia Job 23137.51
Plugging the total sewerage from the existing sewer line so as to reduce the drainage of sewer
line to minimum in wet and foul condition by placing gunny bags filled up with earth and stacked
properly including supplying and laying the filled up gunny bags up to full length and required
5
height as directed by Engineer and subsequent removal of the same after completion of the job
to the entire satisfaction of the Engineer-in-charge, including pumping & bailing out of the water
complete.
a) 250 mm dia pipe Job 1765.35
b) 300 mm dia pipe Job 2541.33
c) 400 mm dia pipe Job 4118.75
d) 450 mm dia pipe Job 5098.42
e) 600mm dia pipe Job 9063.19
f) 700mm dia pipe Job 11790.03
Plugging the total storm water drain from the existing storm water line so as to reduce the
drainage of storm line sewer line to minimum in wet and foul condition by placing gunny bags
filled up with earth and stacked properly including supplying and laying the filled up gunny bags
6
up to full length and required height as directed by Engineer and subsequent removal of the
same after completion of the job to the entire satisfaction of the Engineer, including pumping &
bailing out of the water complete.
a) 150 mm dia pipe Job 634.12
b) 250 mm dia pipe Job 1765.35
c) 300 mm dia pipe Job 2541.33
d) 400 mm dia pipe Job 4520.08
e) 450 mm dia pipe Job 5098.42
f) 600 mm dia pipe Job 9063.19
g) 900 mm dia pipe Job 20393.69
Providing lead caulked joints including the cost of pig lead supply and fixing of rubber gaskets
7 welding, and cutting of MS pipes and specials, including the cost of H/P of T&P at site (For
watermains at interconnection point / Y-tee/ valve) including cost of dewatering.

a) upto 300 mm dia Each 17685.04


b) 400 - 600 mm dia Each 22105.7
Supply and installation of MS pipe (6 mm thick) with 750 Micorn PV coating internally and 250
micron anti corrosive bituminous paint externally with a tolerance of 6" in gradient by trenchless
technology method at an average depth of 5 mtrs below the road level including excavation &
filling of pits, dewatering arrangements, supporting systems for soil, including the approval from
8 the concerned department. The firm will also supply the test certificate w.r.t M.S. Pipe, design of
PV coating etc. The work also involves under ground mapping of services, barricading,
installation of flickering lights etc, clearing site in all respects after submitting CCTV survey
report from u/s to d/s, connection manholes along with the site of drawing showing work
complete in all respect.
a) 250 mm dia( 6mm thick) Mtr 17685.04
b) 600 mm dia ( 10mm thick) Mtr 64845.16
Providing and laying of 100 mm GI pipe, medium class, Jindal make, with all accessories like
9
bends, sockets, etc all complete
Mtr 685.04
from steel confirming to IS: 2062) the steel pipe surface internal and external shall be blasted to
near white and then coated with solvent less P.U. coating of nominal 750 microns and nominal
1000 microns on exterior and interior surface respectively all approved/used by
railway/DDA's/RDA's project for sewer and water lines with design and construction of Man
holes at approximate 30 meter interval or required distance with trenchless construction
technique below the water table preferably without the need of dewatering, Accuracy of level at
required gradient/slope to be achieved by use of Laser/CCTV controlled by suitable
10 equipment. .In the last pit, the equipment to be positioned at surface in a single traffic lane. The
work shall be done in such a manner that it will not disturb the smooth movement of traffic . The
item includes excavation of trenches and recovery pit andr backfilling after work completed at
the site of work mobilization and demobilization of equipment consumable etc as needed to
complete the work and cleaning of site complete including disposal of surplus earth within 10 km
lead and making water and manhole connections.Traffic control arrangement and lighting
display of sign board. Insurance of work man etc complete including removal of all hindrances,
unforeseen items permission of other dept. (dept. shall only assist in getting permissions etc.)
a) 900mm dia pipe by trenchless technology Mtr 79582.7
Providing and laying MS pipes/barels made out of required thickness MS plate Including
painting with epoxy paint of approved quality outside and inside tested to a head of 15kg/cm
11
square suitable for welding joints conforming to IS 3589-1981, IS 784-1974 including testing of
the specified head as directed by the Engineer.
a) Pipes made up of MS sheet(6mm to12mm th.) Kg 83.66
Providing and laying MS special such as tees, bends, collars, tails pieces etc made out of
required thickness MS sheet including painting with epoxy paint of approved quality outside and
12
inside tested to a head of 15kg/sqcm suitable for welding joints conforming to IS 3589-1981, IS
784-1974 including testing of the specified head as directed by the Engineer.

13 Specials made up of MS sheet(6mm to 12mm th.) Kg 99.42


Providing H.S. Pipe, made out of 6 mm thick MS plate with inside cement mortar lining of 25 mm
14
thick and 25 mm thick outside coating as per IS :1916 of following diameter
a) 300 mm dia pipe Mtr 6336.35
b) 400 mm dia pipe Mtr 8473.93
c) 600 mm dia pipe Mtr 11052.85
Laying H.S. Pipe, made out of 6 mm thick MS plate with inside cement mortar lining of 25 mm
15
thick and 25 mm thick outside coating as per IS :1916
a) 300 mm dia pipe Mtr 220.67
b) 400 mm dia pipe Mtr 294.63
c) 600 mm dia pipe Mtr 364.95
Providing and fixing 400 mm dia D/F non- return / check valve of PN 1.0 rating having
Body/Door of CI Gr. 20, TRUNNION shaft AISI 410, Face & Seat ring of GM i.e. metal to metal
16
seat & not Rubber to metal, generaly confirming to IS: 5312, Falnge flat face drilled to ISI 538
Each 172495.57
Part IV & VI/BS 10 Table "D" .

Providing and fixing CI D/F Sluice Valve with S&S ( IS 6603 12 Sr 12) stain ang gun metal Parts
17 confirming to IS 14846 of approved make/ of approved brand ( withcap ) in the existing pipe
with bolts, nuts, rubber insertions etc. complete and as per the direction of Engineer

a) 400 mm dia Each 109146.28


b) 600 mm dia Each 250581.77
required distance. Pipe to be laid with trenchless construction technique. Accuracy of level at
required gradient/slope to be achieved by use of laser /CCTV controlled by any suitable
equipment. In the last pit the equipment to be positioned at surface in a single traffic lane for the
work. The item includes excavation of trenches and recovery pits, excavated earth taken out
and their backfilling after work completed at the site. Work includes mobilization and
demobilization of equipment consumable etc as needed to complete the work and
cleaning of site complete including disposal of surplus earth within 10 km lead and making
18 water and manhole connections, traffic control arrangement, lighting of complete work site area,
display of sign board. Insurance of work man etc complete including removal of all hindrances,
unforeseen items permission of other deptt (deptt shall only assist in getting permissions etc.).
Nothing extra shall be paid on this account to complete the job. The firm will also supply the
test certificate w.r.t MS pipe design and P.U coating etc, during the execution of work.
Dewatering of pit and making good by back filling in layers of 20 cm each as per the relevant
CPWD specifications and disposal of surplus earth as per direction of Engineer-in charge. The
firm has to make connections in the u/s and D/S manholes at the same existing invert level
a) 1400 mm dia pipe by Trenchless technology Mtr 152997.79
Supply and installation of 450 mm dia MS pipe of 10 mm wall thickness confirming to IS
2062 suitable for welding joints with 750 Micron P.U. coating internally and anti-
corrosive bituminous paint on external surface, with tolerance of 6" in or gradient by
trenchless technology method at an average depth of 4-4.5m below the road level
including interconnection with existing chambers ( with required excavation and its
restoration including dewatering arrangement) including thrust pit and receiving pit
and the supporting system of soil should be got approved from the department before
execution. The trenchless has to be carried out below existing deep nallah below
19 road, in sub-soil and existing services. The firm will also supply the test certificate w.r.t Mtr 35414.32
MS pipe design and P.U coating etc, during the execution of work. The work also
involved necessary number of thrust pit and receiving pit as per the site
condition to perform boring including road cutting under ground mapping of
service. Dewatering of pit and making good by back filling in layers
of 20 cm each as per the relevant CPWD specifications and disposal of surplus earth
as per direction of Engineer-in charge. The firm has to make connections in the u/s
and D/S manholes at the same existing invert level including necessary plugging in the
existing line by dismantling and restoration of the connection manholes complete.
Providing and Laying mild steel pipe 1500mm internal dia. made from 12mm thick MS
Plate conforming to IS 2062, Interior lining with cement mortar and exterior surface
20 treated with coating and wraping confirm to IS3589 2001, IS: 10221-1982, 11909-1986, Mtr 54160.9
specifications i/c all lead and lift complete as per direction of the Engineer-in-charge

Providing and Laying M.S. specials such as tees, bends, collars, tail piece etc. made
out of required thickness of M.S. Plate i/c welding, painted with epoxy paint of approved
21 quality outside and inside tested to a head of 15 Kg/ cm Sq. suitable for welding joints Kg 104.22
confirming to IS: 3589 , IS: 784-1978, 7322-1974 to specified head as directed by
Engineer-in-charge
Providing and laying of 1500 mm dia. M.S. Pipe made up of 16mm thk. M.S. Plate as
per IS2062 through trenchless technology by Specialized Laser guided Tunnel boring
Machine with steering kit to cross the carriage way i/c maintain levels with the help of
laser guided equipment, excavation of thrust & receiving pit side shoring, providing
thrust bed & blocks, welding cutting the steel pipes surface internal & external painted
22 Rm 209820.52
with Epoxy paint on each face of pipe, filling back compaction disposal of surplus earth,
i/c, generator, JCB, cranes, trenchless machine, jacks, hydraulic technology, testing etc.
all material, Labour and T&P complete job as per direction of Engineer-in-charge.
Letter of Price Bid

Date:
OCB No.: NCRTC (DM/CN/COR-OF/59)
Invitation for Bid No.: NCRTC (DM/CN/COR-OF/59)

To
National Capital Region Transport Corportation Limited
7/6, Siri Fort Institutional Area,
August Kranti Marg,
New Delhi – 110049
Tel : +91-11-41066943
Fax : +91-11-41066953

We, the undersigned, declare that:

(a) We have examined and have no reservations to the Bidding Documents, including Addenda issued in accordance with Instructions to Bidders (ITB) 8.

(b) We offer to execute in conformity with the Bidding Documents and the Technical Bid submitted for the following Works: Package 3: Construction of elevated viaduct from Duhai EPE to Shatabdi Nagar Station and seven
Nos. of elevated Stations viz., Murad Nagar, Modi Nagar South, Modi Nagar North, Meerut South, Partapur, Rithani & Shatabdi Nagar [excluding Architectural Finishing & Pre-engineered steel roof structure of
Stations] of Delhi – Meerut Regional Rapid Transit System (RRTS) Corridor.
For following LOT
DM/CN/COR-OF/59,LOT P3L2:-Construction of elevated viaduct from start of Modi Nagar North Station to Shatabdi Nagar Station and 5 elevated stations viz. Modi Nagar North, Meerut South, Partapur, Rithani&
Shatabdi Nagar[Excluding Architectural Finishing & Pre-engineered steel roof structure of Stations] of Delhi – Ghaziabad – Meerut RRTS Corridor.

(c) The total price of our Bid, excluding any discounts offered in item (d) below is:
[amount in INR in words], #VALUE! [amount in INR in figures] 0.00

The total bid price from the Summary of Bill of Quantities should be entered by the bidder inside this box. Absence of the total bid price in the Letter of Price Bid may result in the rejection of the bid.

(d) The discounts offered and the methodology for their application are 0.00%
[insert discounts and methodology for their application if any]

In case both the LOTs i.e LOT P3L1 & P3L2 are awarded to us we offer an additional Discount of Percentage of offered bid price of the LOT P3L1 and

Percentage of the offered bid price of the LOT P3L2 , to be distributed proportionally in each pay item.

(e) Our Bid shall be valid for a period of 180 days from the date fixed for the bid submission deadline in accordance with the Bidding Documents, and it shall remain binding upon us and may be accepted at any time before
the expiration of that period.
(f) If our Bid is accepted, we commit to obtain a performance security in accordance with the Bidding Documents.

(g) We have paid, or will pay the following commissions, gratuities, or fees with respect to the bidding process or execution of the Contract*

Name of Recipient Address Reason Amount

(h) We understand that this bid, together with your written acceptance thereof included in your notification of award, shall constitute a binding contract between us, until a formal contract is prepared and executed.

(i) We understand that you are not bound to accept the lowest evaluated bid or any other bid that you may receive.

(j) We agree to permit ADB or its representative to inspect our accounts and records and other documents relating to the bid submission and to have them audited by auditors appointed by ADB.

Name

In the capacity of

Signed

Duly authorized to sign the Bid for and on behalf of

Date
*If none has been paid or is to be paid, indicate “None”.