UNM2000

Network Convergence
Management System V2.0R4

Standalone System Installation


Guide (Based on Windows)
Version: A

Code: MN000003318

FiberHome Telecommunication Technologies Co., Ltd.

September 2017
Thank you for choosing our products.

We appreciate your business. Your satisfaction is our goal.


We will provide you with comprehensive technical support
and after-sales service. Please contact your local sales
representative, service representative or distributor for any
help needed at the contact information shown below.

Fiberhome Telecommunication Technologies Co., Ltd.

Address: No. 67, Guanggu Chuangye Jie, Wuhan, Hubei, China


Zip code: 430073
Tel: +6 03 7960 0860/0884 (for Malaysia)
+91 98 9985 5448 (for South Asia)
+593 4 501 4529 (for South America)
Fax: +86 27 8717 8521
Website: http://www.fiberhomegroup.com
Legal Notice

are trademarks of FiberHome Telecommunication Technologies Co., Ltd.


(Hereinafter referred to as FiberHome)
All brand names and product names used in this document are used for
identification purposes only and are trademarks or registered trademarks
of their respective holders.

All rights reserved

No part of this document (including the electronic version) may be


reproduced or transmitted in any form or by any means without prior
written permission from FiberHome.
Information in this document is subject to change without notice.
Preface

Version

Version Description

A Initial version, corresponding to V2.0R4.

Related Documentation
Document Main Content Phase to Use
Introduces the functions, application
UNM2000 Network
scenarios and technical specifications
Convergence Management Network Planning
of the UNM2000 Network
System Product Description
Convergence Management System.

UNM2000 Network Introduces how to install the


Convergence Management UNM2000 Network Convergence Network
System Installation Guide Management System on the Windows deployment
(Based on Windows) operating system.

UNM2000 Network Introduces how to install the


Convergence Management UNM2000 Network Convergence Network
System Installation Guide Management System on the SUSE deployment
(Based on SUSELinux) Linux operating system.

UNM2000 Network Introduces the operation guidelines of


Network
Convergence Management the UNM2000 Network Convergence
maintenance
System Operation Guide Management System.

Network
UNM2000 Network The meaning and usage constraints of
maintenance /
Convergence Management shortcut menus and buttons in the
service
System GUI Reference menus and windows
deployment

Intended Readers

This manual is intended for the following readers:

u Network planning engineers

u Network monitoring engineers

u On-site maintenance engineers

I
Terminology Conventions

Terminology Convention
FiberHome UNM2000 Network Convergence Management
UNM2000
System

Symbol Conventions

Symbol Convention Description

Note Important features or operation guide.

Possible injury to persons or systems, or cause traffic


Caution
interruption or loss.

Warning May cause severe bodily injuries.

➔ Jump Jumps to another step.

Cascading
→ Connects multi-level menu options.
menu
Bidirectional
↔ The service signal is bidirectional.
service
Unidirectional
→ The service signal is unidirectional.
service

II
Operation Safety Rules

The network management computer should be placed away from


direct sunlight, electromagnetic interference, heat source,
humidity and dust, and with at least 8cm distance from other
objects in order to keep good ventilation.

Use UPS power supply to avoid loss of network management


data caused by accidental power failure.

The computer case, UPS power supply and switch (or hub)
should be connected to protection earth ground.

To shut down the network management computer, exit the


operation system normally and then shut off the power supply.

Do not exit the network management system when it is working


normally. Exiting the network management system does not
interrupt traffic in the network, but precludes centralized control of
the networked equipment.

The network management computer cannot be used for purposes


other than network management. Use of unidentified memory
devices should be prohibited so as to avoid computer viruses.

Do not delete any file in the network management system


randomly or copy any irrelevant file into the network management
computer.

Do not visit Internet via the network management computer.


Doing so may increase data flow in the net card and hence affects
normal network management data transmission or results in other
accidents.

III
Do not perform service configuration or expansion during service
busy hours via the network management system.

Do not modify the network management computer’s protocol


settings, computer name or LAN settings. Doing so may result in
abnormal operation of network management system.

IV
V
VI
Contents

Preface...................................................................................................................I

Operation Safety Rules .........................................................................................III

1 Installation Overview.......................................................................................1

1.1 Operating Mode ................................................................................2

1.2 System Configuration Requirements .................................................2

1.2.1 Hardware Configuration Requirements................................2


1.2.2 Software Configuration Requirements .................................4

2 Installation Process.........................................................................................6

2.1 Initial Installation ...............................................................................7

2.1.1 Installing the Server End for the First Time...........................7


2.1.2 Installing the Client End for the First Time ............................9

2.2 Upgrade Installation ........................................................................10

3 Installing the UNM2000.................................................................................13

3.1 Installing the Server End .................................................................14

3.1.1 Configuring the System Environment ................................14


3.1.2 Installing the Database......................................................18
3.1.3 Installing the UNM2000 Software ......................................38
3.1.4 Initializing the Database Table...........................................49
3.1.5 Checking Services ............................................................53

3.2 Installing the Client End ..................................................................54

3.2.1 Installing the JDK..............................................................54


3.2.2 Installing the Client End of the UNM2000...........................58

4 Upgrading the UNM2000 ..............................................................................64

4.1 Preparation for Upgrade..................................................................65

4.2 Backing Up the Original Configuration Data.....................................65

4.3 Backing Up the Software Package ..................................................67

4.4 Uninstalling the Current Version ......................................................67


4.5 Installing the Upgrade Version.........................................................71

4.6 Importing the Configuration Data .....................................................71

4.7 Verifying the Upgrade of the Server End ..........................................74

5 FAQ..............................................................................................................76

5.1 How to View the Installation / Uninstallation Logs.............................77

5.2 How to View the Java Version .........................................................77

5.3 How to Uninstall the MySQL Database............................................78

5.4 How to Uninstall the Tomcat ............................................................79

5.5 How to View the Occupation of System Ports ..................................81

5.6 New Alarms Failed to Be Reported in Real Time / New ONU List
Failed to Be Refreshed ...................................................................82

Appendix A Abbreviations ............................................................................85


1 Installation Overview

Before installing the UNM2000, you should be familiar with the operating mode and
configuration requirement of the UNM2000, so as to complete the installation
smoothly.

Operating Mode

System Configuration Requirements

Version: A 1
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

1.1 Operating Mode

The UNM2000 uses the Client / Server architecture. The UNM2000 client end and
server end can be installed on one computer, or on two computers respectively. The
server end supports the access and operations of multiple client ends.

The installation package of the UNM2000 server end includes the following two
components and you can select the components to be installed as required.

u Client: the client end distribution program of the UNM2000.

u Server: the server end program of the UNM2000.

Note:

u It is recommended that you install the client end distribution program


and the server end program of the UNM2000 on one computer. This
manual introduces the installation procedures on the presumption
that the two programs are to be installed on the same computer.

u The UNM2000 supports the remote installation of the client end. You
can access the server in which the client end distribution program
locates to download and install the client end via the IE browser.

1.2 System Configuration Requirements

The following introduces the hardware and software configuration requirements for
the computer on which the UNM2000 is to be installed.

1.2.1 Hardware Configuration Requirements

Server End

The hardware configuration requirements of the UNM2000 server vary according to


the network scale. For detailed requirements, see Table 1-1.

2 Version: A
1 Installation Overview

Table 1-1 Hardware Configuration Requirements of the Server End

Network CPU Clock Rate CPU Mem- Hard Hard Disk Format Network Card
Scale Quantity ory Disk
Space

The format of the disk


Equivalent to
on which the
more than
database and the
1000 OLTs Embedded double
Intel E7-8837 (8- UNM2000 will be
that are fully 4 64G 4*600GB Gb dual-port
core), 2.6GHz installed (disk C and
configured and network cards
disk D by default
connected
respectively) should
with ONUs
be NTFS.
The format of the disk
Equivalent to
on which the
500 to 1000
database and the
OLTs that are Intel XeonE7- Embedded double
UNM2000 will be
fully 4610V2 (8-core), 4 32G 4*600GB Gb dual-port
installed (disk C and
configured and 2.3GHz network cards
disk D by default
connected
respectively) should
with ONUs
be NTFS.
The format of the disk
Equivalent to
on which the
100 to 500
database and the
OLTs that are Intel XeonE5- Embedded double
UNM2000 will be
fully 2667V2 (8-core), 2 32G 2*600GB Gb dual-port
installed (disk C and
configured and 3.3GHz network cards
disk D by default
connected
respectively) should
with ONUs
be NTFS.
The format of the disk
Equivalent to
on which the
less than 100
database and the
OLTs that are Intel XeonE5- Embedded single
UNM2000 will be
fully 2430V2 (6-core), 2 16G 2*600GB Gb dual-port
installed (disk C and
configured and 2.5GHZ network card
disk D by default
connected
respectively) should
with ONUs
be NTFS.

Version: A 3
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Client End

Table 1-2 shows the hardware configuration requirements of the UNM2000 client
end.

Table 1-2 Hardware Configuration Requirements of the Client End

Network Scale CPU Clock Rate CPU Mem- Hard Disk Hard Disk Video Card
Quantity ory Space Format

Equivalent to
The format of the
more than
disk on which the
1000 OLTs that
Intel XeonE5-2637V2 UNM2000 will be 1 GB discrete
are fully 1 16G 1*2TB
(4-core), 3.5GHz installed (disk D graphics
configured and
by default)
connected with
should be NTFS
ONUs
Equivalent to The format of the
500 to 1000 disk on which the
OLTs that are Intel i3-4130 (2-core), UNM2000 will be 1 GB discrete
1 8G 1*1TB
fully configured 3.4GHz installed (disk D graphics
and connected by default)
with ONUs should be NTFS
Equivalent to The format of the
100 to 500 disk on which the nVIDIA
Intel Core i5-4200U (1.
OLTs that are UNM2000 will be GT720M 1GB
6G-2.6G/3M) (2-core), 1 8G 1*500GB
fully configured installed (disk D discrete
3.4GHz
and connected by default) graphics
with ONUs should be NTFS
Equivalent to The format of the
less than 100 disk on which the
Intel Corei5-4200U (1. Intel HD 4400
OLTs that are UNM2000 will be
6G-2.6G/3M) (2-core), 1 4G 1*500GB integrated
fully configured installed (disk D
3.4GHz graphics
and connected by default)
with ONUs should be NTFS

1.2.2 Software Configuration Requirements

The software requirements for the computer running the UNM2000 server end are
as shown in Table 1-3.

4 Version: A
1 Installation Overview

Table 1-3 Software Configuration Requirements of the Server End

Configuration Item Requirement

Windows Server 2012 R2 Standard (64-bit) or Windows Server


2008 R2 Standard (64-bit)
Operating system
SUSE Linux Enterprise 11 (64-bit)

Solaris 11 (64-bit)

SQL Server 2008 R2


Database
MySQL 5.5

JDK JDK 1.6.0


Internet protocol TCP/IPv4 and TCP/IPv6

The software requirements for the computer running the UNM2000 client end are as
shown in Table 1-4.

Table 1-4 Software Configuration Requirements of the Client End

Configuration Item Requirement

Operating system Windows 7, Windows 8 or Windows 10


JDK JDK 1.6.0
Internet protocol TCP/IPv4 and TCP/IPv6

Caution:

u Before installing the UNM2000 server or client, uninstall the JDK of


the version other than JDK 1.6.0 on the computer.

u SNMP is the network management standard based on the TCP/IP


protocol suite, and therefore the TCP/IPv4 and TCP/IPv6 protocols
should be installed both at the UNM2000 server end and client end.

Version: A 5
2 Installation Process

The installation includes the initial installation and upgrade installation. You can
install the UNM2000 according to the installation flowchart.

Initial Installation

Upgrade Installation

6 Version: A
2 Installation Process

2.1 Initial Installation

The following introduces how to install the server end and the client end for the first
time.

2.1.1 Installing the Server End for the First Time

When installing the UNM2000 server end for the first time on Windows operating
system (OS), you can refer to the flowchart shown in Figure 2-1 or Figure 2-2
according to the type of database to be used.

Note:

The JRE software will be installed by default during installing the


UNM2000.

Version: A 7
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Figure 2-1 Flowchart of Installing the Server End for the First Time (for MySQL)

8 Version: A
2 Installation Process

Figure 2-2 Flowchart of Installing the Server End for the First Time (for SQL Server)

2.1.2 Installing the Client End for the First Time

When installing the UNM2000 client end for the first time under the Windows
operating system, users can refer to the flowchart shown in Figure 2-3.

Version: A 9
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Figure 2-3 Flowchart of Installing the Client End for the First Time

2.2 Upgrade Installation


Upgrading the Server End

When upgrading the UNM2000 server end on the Windows OS, you can refer to the
flowchart shown in Figure 2-4.

10 Version: A
2 Installation Process

Figure 2-4 Flowchart of Upgrading the Server End

Version: A 11
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Upgrading the Client End

The UNM2000 supports automatic upgrading of the client end. Upon startup, the
client end will check for updates and upgrade itself automatically, so as to
synchronize the version of the client end with that of the server end.

12 Version: A
3 Installing the UNM2000

The following introduces how to install the UNM2000 for the first time on the
Windows OS.

Installing the Server End

Installing the Client End

Version: A 13
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

3.1 Installing the Server End

The following introduces how to install the UNM2000 server end for the first time on
the Windows OS.

3.1.1 Configuring the System Environment

To ensure the security of the system, the system firewall denies the access to the
system ports. In order to use the UNM2000 normally, you need to enable the firewall
and set a firewall custom rule to allow the UNM2000 to access specific ports.

Prerequisite

You have logged into the Windows OS as an administrator.

Procedure

1. Select Start→Administrative Tool→Windows Firewall with Advanced


Security to display the Windows Firewall with Advanced Security window.

2. Select the Inbound Rules or Outbound Rules in the left pane and click New
Rule in the right pane to display the New Inbound Rule Wizard or New
Outbound Rule Wizard dialog box.

3. Select Port and click Next.

14 Version: A
3 Installing the UNM2000

4. See Table 3-1 to select the corresponding protocol, enter the port number and
click Next. The port 3306 is used as an example to introduce how to add an
inbound rule.

Table 3-1 Custom Rule Settings

Source Protocol Destination Source Port Additional Description


Network Port Options

The port to be
used by the
Description
0/0 TCP 52001:52399 52001:52399 ICE or the
information
application
program.

Description
0/0 UDP 161 161
information ManagerTRAP
Description port.
0/0 UDP 162 162
information
Description MySQL
0/0 TCP 3306 3306
information database port

Version: A 15
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Table 3-1 Custom Rule Settings (Continued)

Source Protocol Destination Source Port Additional Description


Network Port Options

Description SQL Server


0/0 TCP 1433 1433
information database port

The Web client


distribution
port. It is 8080
by default.
Description
0/0 TCP 8080 8080 Specify the
information
port number
according to
the actual
situation.

5. Select Allow the connection and click Next.

16 Version: A
3 Installing the UNM2000

6. Select Domain, Private and Public, and then click Next.

7. Enter 3306 in the Name textbox and relevant description in the Description
(optional) textbox. Then click Finish to complete adding the inbound rule for
the port.

8. Repeat Step 2 to 7 until all inbound and outbound rules are added.

Version: A 17
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

3.1.2 Installing the Database

The following introduces how to install the supporting database.

3.1.2.1 Installing the SQL Server Database

The following introduces how to install the SQL server database.

Prerequisite

u The hardware and software configurations of the server meet the requirements
described in System Configuration Requirements.

u The NET Framework 3.5 SP1 component is installed.

u If Microsoft Visual Studio 2008 is installed on the server, you need to install the
VS-2008 sp1 first.

u The SQL Server2008 installation package is obtained.

Note:

If the MySQL database is to be adopted, skip the procedures in this


section because it will be installed during the UNM2000 software
installation.

Procedure

1. Double-click SQLFULL_x86_CHS.exe to decompress it.

2. Double-click setup.exe in the file folder to display the SQL Server Installation
Center dialog box.

18 Version: A
3 Installing the UNM2000

3. Click Installation in the left pane, and select New installation or add features
to an existing installation. in the right pane.

Version: A 19
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

4. The system will check the installation program support rules. Then click OK in
the SQL Server 2008 R2 Setup dialog box that appears.

Note:

If the check fails, you need to solve all problems causing failures
according to the prompt, and then reinstall the SQL server database.

5. Select the SQL Server 2008 R2 version to be installed, type the product key,
and click Next.

20 Version: A
3 Installing the UNM2000

6. Select I accept the license terms, and click Next.

Version: A 21
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

7. Click Install to install the program support files.

8. The system will check the installation program support rules. Then click Next in
the SQL Server 2008 R2 Setup dialog box that appears.

Note:

If the check fails, you need to solve all problems causing failures
according to the prompt, and then reinstall the SQL server database.

22 Version: A
3 Installing the UNM2000

9. Select SQL Server Feature Installation, and then click Next.

Version: A 23
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

10. Select the components to be installed and click Next.

It is recommended to select the functional components to be installed


according to the following figure. You can also click Select All to install all
components.

11. The system will check the installation rules. Then click Next.

24 Version: A
3 Installing the UNM2000

12. Adopt the default settings (recommended), and click Next.

Version: A 25
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

13. View the disk space summary, and click Next.

14. Configure the server.

1) Click Use the same account for all SQL Server services, select NT
AUTHORITY\NETWORK SERVICE as the account name and click OK.

26 Version: A
3 Installing the UNM2000

2) Click Next in the displayed SQL Server 2008 R2 Setup dialog box.

15. Configure the database engine.

Version: A 27
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

1) Click Mixed Mode (SQL Server authentication and Windows


authentication), and type the password of the SQL Server system
administrator in the Enter password and Confirm password text boxes.
The password unm2K10 is recommended.

2) Click Add Current User and click Next.

16. Do not select sending the error reports, and then click Next.

28 Version: A
3 Installing the UNM2000

17. The system will check the installation configuration rules. Then click Next.

Version: A 29
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

18. Verify the functions of SQL Server 2008 R2 to be installed, and click Install.

19. After the installation is completed, click Close in the dialog box as shown
below.

30 Version: A
3 Installing the UNM2000

3.1.2.2 Installing the MySQL Database

The MySQL database supports two installation modes: installation-required and


installation-free (recommended). This manual uses the installation-free mode as an
example to introduce how to deploy the MySQL database. The name of the
installation-free package is MySQL 5.5.34.rar.

Prerequisite

u The hardware and software configurations of the server meet the requirements
described in System Configuration Requirements.

u A static IP address is assigned for the UNM2000 server.

Procedure

1. Decompress the installation package to disk D.

Decompress the MySQL file folder to the root directory of disk D of the network
management server.

Version: A 31
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Caution:

The MySQL database must be installed on disk D; otherwise running the


UNM2000 may fail.

2. Install the MySQL database service.

1) Select Start→Run, and type cmd in the Open text box of the dialog box
that appears, as shown below.

2) Click OK to display the CLI window and then execute the following
commands.

C:\Document and Settings\Administrator>d:

D:\>cd MySQL\bin

D:\ MySQL\bin>mysqld.exe -install MySQL --defaults-file=\"d:\MySQL\my.ini\"

If Service successfully installed is displayed, the service is installed


successfully, as shown below.

32 Version: A
3 Installing the UNM2000

Note:

After being installed, the MySQL database service appears in the


Services window.

3) Close the CLI window.

3. Configure the MySQL parameters.

1) Open the my.ini file in the D:\MySQL\ directory.

2) See Table 3-2 to check and set the corresponding parameters in the my.
ini file.

Table 3-2 The my.ini File Parameter Configuration Table

Parameter Value
[client] default-character-set gbk

key_buffer_size 256M
max_allowed_packet 64M
table_open_cache 256
sort_buffer_size 256K
read_buffer_size 64K
[mysqld] read_rnd_buffer_size 256K
myisam_sort_buffer_size 64M
myisam_recover_options BACKUP, FORCE
thread_cache_size 8
query_cache_size 16M
thread_concurrency 8

Version: A 33
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Table 3-2 The my.ini File Parameter Configuration Table (Continued)

Parameter Value
max_connections 500

character-set-server gbk

innodb_data_home_dir D:\MySQL\data/

innodb_data_file_path ibdata1:256M:autoextend
innodb_buffer_pool_size 512M
innodb_additional_mem_pool_size 8M
innodb_log_file_size 256M
innodb_log_buffer_size 8M
innodb_flush_log_at_trx_commit 2
innodb_lock_wait_timeout 50
innodb_file_per_table 1
[mysqldump] max_allowed_packet 64M
key_buffer_size 128M
sort_buffer_size 128M
[myisamchk]
read_buffer 2M
write_buffer 2M

3) Save the my.ini file.

4. Access the Services window to start the MySQL database service.

1) Select Start→Administrative Tools→Services to display the Services


window, and then select MySQL.

2) Right-click MySQL and select Properties from the shortcut menu to


display the MySQL Properties (Local Computer) dialog box.

34 Version: A
3 Installing the UNM2000

3) Select Automatic from the Startup type drop-down list and click Start to
start the MySQL service. After the service is started, the process box will
be closed automatically.

4) Click OK in the MySQL Properties (Local Computer) dialog box. The


Status of MySQL will turn into Started in the Services window.

Subsequent Operation

After installing the MySQL database, configure the environment variables of the
database. The configuration procedures are as follows:

Version: A 35
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Caution:

If the Java environment variables are not configured, you cannot query
the Java version. See How to View the Java Version for the query
method.

1. On the desktop of the UNM2000 server, right-click Computer and select


Properties from the shortcut menu to display the System dialog box.

2. In the left area of the System window, click Advanced system settings to
open the Advanced tab of System Properties dialog box.

3. Click Environment Variables to display the Environment Variables dialog


box, as shown below.

36 Version: A
3 Installing the UNM2000

4. In the System variables list box, select the Path variable and click Edit to
display the Edit System Variable dialog box, as shown below.

5. Add the variable value %JAVA_HOME%\bin;D:\MySQL\bin; and then click


OK.

Note:

Different variable values should be separated by semicolons.

Version: A 37
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

3.1.3 Installing the UNM2000 Software

The following introduces how to install the UNM2000 for the first time on the
Windows OS.

Prerequisite

u The hardware and software configurations of the server meet the requirements
described in System Configuration Requirements.

u A static IP address is assigned for the UNM2000 server.

u The installation package of the UNM2000 is obtained.

u The system firewall inbound/outbound rules have been set, or the system
firewall and anti-virus software have been disabled.

Procedure

1. Double-click the UNM2000 installation software, and click Next in the displayed
dialog box.

2. Select I accept the agreement and click Next.

38 Version: A
3 Installing the UNM2000

3. Select the Client and Server components and click Next.

Note:

When the UNM2000 server end is installed, the Client component is


selected by default. The Client component is the client end distribution
program of the UNM2000. After the component is installed, users can
install the UNM2000 client end via WEB mode.

Version: A 39
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

4. Specify the UNM2000 installation path (the default installation path D:


\unm2000 is recommended), and then click Next.

40 Version: A
3 Installing the UNM2000

5. Select English as the installation language and click Next.

6. Set the Tomcat installation path (the default installation path D:\ApacheTomcat
is recommended), and then click Next.

If the ApacheTomcat has been installed on the computer, ➔ step 9.

Version: A 41
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

7. Click Yes in the alert box that appears.

8. Set the Tomcat port (the default port 8080 is recommended), and then click
Next.

42 Version: A
3 Installing the UNM2000

9. Specify the server deployment mode. Select the default Centralized and click
Next.

Note:

This manual only introduces the single-instance installation mode (that is,
deploying all services of the server end on the same computer) and
therefore Centralized is selected.

Version: A 43
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

10. Specify the IP address of the computer running the server end, and then click
Next.

44 Version: A
3 Installing the UNM2000

11. Select the database type and then click Next.

12. Configure the database parameter.

4 Set the MySQL parameter, set the database of the UNM2000 server end
according to Table 3-3 and then click Next.

Table 3-3 Description of the MySQL Database Information

Item Description

Host Sets the IP address of the computer running the server end.

DataBase Password Sets the database password. The default value is vislecaina.

Confirm Password Enter the password of the database again.

Port Sets the database port. The default value is 3306.

Version: A 45
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

4 Set the SQL Server parameter, set the database of the UNM2000 server
end according to Table 3-4 and then click Next.

Table 3-4 Description of the SQL Server Database Information

Item Description

Host Sets the IP address of the computer running the server end.

Sets the password of the database. It should be consistent with


DataBase Password
the password typed during database installation.

Confirm Password Enter the password of the database again.

Port Sets the database port. The default value is 1433.

SQL Server instance name, which should be consistent with


SQL Server InstanceNote 1 that set during database installation. It is mssqlserver by
default.
Note 1: This item appears only when the SQL server database is selected.

46 Version: A
3 Installing the UNM2000

13. Confirm the installation information and then click Next.

Version: A 47
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

14. The installation of the program starts. In the alert box displayed a while later,
click Finish.

15. If you click No in the displayed alert box, the computer will not be restarted
immediately.

Note:

Initialize the database table according to Initializing the Database Table


and then restart the computer.

48 Version: A
3 Installing the UNM2000

3.1.4 Initializing the Database Table

The following introduces how to initialize the database table architecture.

Prerequisite

u The UNM2000 software has been installed successfully.

u The following services are stopped: UnmBus, UNMCFGDataMgr,


UNMCMAgent, UNMCMService, UnmNode and UnmServiceMonitor.

u The MySQL service is started.

Procedure

1. Select Start→Run, and type cmd in the Open text box of the dialog box that
appears, as shown below.

2. Click OK to display the Command Line Interface (CLI) window and then
execute the following commands.
C:\Users\Administrator>d:
D:\>cd unm2000\server\tool
D:\unm2000\server\tool>installdb.bat –i

Version: A 49
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

3. Complete the database initialization according to the GUI prompt.

The procedures may vary with the database selected. The following figure
takes the initialization procedure of SQL Server as an example.

50 Version: A
3 Installing the UNM2000

Figure 3-1 Initialization Procedure

Version: A 51
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Table 3-5 Initialization Procedure

No. Meaning Description

Select the database type


1 Please choose the database type sequence number according to the
current database.
Default value. It is displayed only
Input database file disk partition
2 when the SQL Server database is
label
selected.
Default value. It is displayed only
Are you sure to use D:\SQL_DATA
3 when the SQL Server database is
as database file path
selected.
Enter the database administrator
Please input the database
4 password according to the actual
administrator's password
project planning.

Enter the database administrator


5 Please input the password again password again according to the
actual project planning.

Default value. It is displayed only


Please input the database instance
6 when the SQL Server database is
name
selected.
7 Please input the database port Default value.
Please choose the database data u 1: CHINESE
8
language u 2: ENGLISH
Please input the omit databases,
9 Default value.
separated by '-'

Are you sure to omit following


10 Default value.
database(s)

Please choose database initial


11 Default value.
type

4. When the system returns Initial databases successful., initializing the


database succeeded, as shown below.

52 Version: A
3 Installing the UNM2000

5. Close the CLI window and restart the computer.

3.1.5 Checking Services

The following introduces how to check the UNM2000 relevant services.

Procedure

1. Select Start→Administrative Tools→Services to display the Services


window.

2. View the services listed in Table 3-6 in the Services window and check
whether the status of the services is Started. If any service is not started, select
the service and click Start Service to start it.

Version: A 53
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Table 3-6 UNM2000 Relevant Services

No. Name Description

1 Apache Tomcat 6 It must be started.


2 UnmBus It must be started.
3 UNMCFGDataMgr It must be started.

4 UNMCMAgent It must be started.


5 UNMCMService It must be started.
6 UnmNode It must be started.
7 UnmServiceMonitor It must be started.
The MySQL database service, which must
8 MySQL be started when the MySQL database is
used.
The relevant service of the SQL server
9 SQL Server (MSSQLSERVER) database, which must be started when the
SQL server database is used.
The relevant service of the SQL server
10 SQL Server Browser database, which must be started when the
SQL server database is used.
The relevant service of the SQL server
11 SQL Server VSS Writer database, which must be started when the
SQL server database is used.
The relevant service of the SQL server
12 SQL Server Proxy (MSSQLSERVER) database, which must be started when the
SQL server database is used.

3.2 Installing the Client End

The following introduces how to install the UNM2000 client end.

3.2.1 Installing the JDK

The UNM2000 client must be installed and running with the Java software, and
therefore you need to install the Java environment before installing the UNM2000
client.

54 Version: A
3 Installing the UNM2000

Background Information

If the JDK has been installed on the computer running the UNM2000 client end, but
its version does not meet the requirements described in Software Configuration
Requirements, you need to uninstall it. See How to View the Java Version.

u If the operating system of the client end is Windows x86 (32-bit), please install
the jdk-6u38-windows-i586.exe.

u If the operating system of the client end is Windows x64 (64-bit), please install
the jdk-6u38-windows-x64.exe.

The following takes the installation of client end on the Windows 7 system as an
example for introduction.

Procedure

1. Double-click the corresponding JDK installation package to display the dialog


box as shown in the following figure, and then click Next.

2. Keep the default settings. Click Next and the installation progress will be
displayed.

Version: A 55
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

3. The default installation path is recommended. Click Next and the installation
progress will be displayed.

56 Version: A
3 Installing the UNM2000

4. Click Finish to complete the installation.

Subsequent Operation

After installing the JDK, configure the environment variables. The configuration
procedures are as follows:

1. On the desktop, right-click Computer and select Properties.

2. In the left area of the window, click Advanced system settings to open the
Advanced tab of System Properties dialog box.

3. Click Environment Variables to display the Environment Variables dialog


box, as shown below.

Version: A 57
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

4. In the System variables list box, create and edit the environment variables
according to the following table. Then click OK.

Action Variable Name Variable Value


C:\Program Files(x86)\Java\jdk1.6.0_38
New JAVA_HOME
(installation path of JDK)

Add the value ;%JAVA_HOME%\bin after the


Edit Path
previous value.

Note:

Different variable values should be separated by semicolons.

3.2.2 Installing the Client End of the UNM2000

The following introduces how to install the UNM2000 client end.

58 Version: A
3 Installing the UNM2000

Prerequisite

u The JDK1.6.0 has been installed.

u The server end operates normally.

u The communication between the server end and the client end is normal.

u The system firewall inbound/outbound rules have been set, or the system
firewall and anti-virus software have been disabled.

Procedure

1. Double-click the browser icon, type http://server end IP:port number/


webstart/ (for example, http://10.78.11.225:8080/webstart/) in the browser
address bar, and then press the Enter key to access the installation window of
the UNM2000 client end.

Note:

The port number indicates the Tomcat port number set during the
installation of the server end.

2. Click Download client to download and save the client end installation
program.

Version: A 59
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

3. Double-click the client end installation program UNM2000_Zip and click Next
in the displayed dialog box.

4. Select I accept the agreement and click Next.

60 Version: A
3 Installing the UNM2000

5. Select the UNMClient component and click Next.

6. Specify the installation path of the UNM2000 client (the default installation path
D:\unm2000client is recommended), and then click Next.

Version: A 61
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

7. Enter the IP address of the server end, and then click Next.

8. Click Next to start installing the client.

9. Click Finish to complete the installation.

62 Version: A
3 Installing the UNM2000

10. After the installation completes, double-click the client shortcut icon .

11. Click Yes in the Update confirmation alert box that appears to update the
client version.

Note:

You need to update the client version for the first login after installing the
client.

12. Wait till the update is completed. In the displayed Log into UNM2000 dialog
box, type the username and password (both are admin by default), and type
the IP address of the corresponding server in Server. Then click Login.

Note:

If the UNM2000 can be logged in successfully, the server end and the
client end are installed successfully.

Version: A 63
4 Upgrading the UNM2000

The following introduces how to upgrade the UNM2000. The UNM2000 supports
automatic upgrading of the client end. Upon startup, the client end will check for
updates and upgrade itself automatically, so as to synchronize the version of the
client end with that of the server end.

Preparation for Upgrade

Backing Up the Original Configuration Data

Backing Up the Software Package

Uninstalling the Current Version

Installing the Upgrade Version

Importing the Configuration Data

Verifying the Upgrade of the Server End

64 Version: A
4 Upgrading the UNM2000

4.1 Preparation for Upgrade

The preparations for upgrading the server end of the UNM2000 include the following
aspects:

u The computer running the UNM2000 server end meets the system
configuration requirements described in System Configuration Requirements.

u The version number of the currently used UNM2000 is confirmed.

u The installation package of the new version of the UNM2000 is obtained.

4.2 Backing Up the Original Configuration Data

To avoid data loss caused by upgrading, it is necessary to back up the original


configuration data before the upgrade.

Prerequisite

To back up the configuration data to the FTP server, ensure that the FTP server can
be normally connected.

Procedure

1. Double-click the browser icon, type http://server end IP:52302/nmtool/ in the


browser address bar, and then press the Enter key to access the login GUI of
the UNM2000 network management tool.

You can also log into the UNM2000 client, and select System→UNM
Management Tool to access the login GUI of the UNM2000 network
management tool.

Version: A 65
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

2. Type the username and password (both are Admin by default) on the login GUI,
and click Login.

3. Click Import/Export to access the configuration import / export GUI.

4. (Optional) Click set backup server button, set the relevant parameters and
click OK. Then, click OK in the alert box that appears.

5. Click export, type the file description and then click OK.

66 Version: A
4 Upgrading the UNM2000

6. In the Export Success alert box that appears, click OK.

4.3 Backing Up the Software Package

When the UNM2000 cannot work normally, you can restore it to the latest version
using the backup software package.

Procedure

1. Copy the unm2000-version number-windows-installer.exe files of both the


new version and the current version to the D:\unm2000 install files directory.

Note:

u If the D:\unm2000 install files directory does not exist, create it and
then back up the files.

u If the software package of the current version does not exist, back up
the current installation folder of the current UNM2000, for example,
D:\unm2000.

4.4 Uninstalling the Current Version

After completing the backup, you can uninstall the current UNM2000 according to
the following procedures.

Version: A 67
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Prerequisite

All the UNM2000 clients are closed.

Procedure

You can uninstall the current version via the following three methods.

u Method 1:

1) Select Start→Control Panel to display the Control Panel window.

2) Click Uninstall a program to display the Programs and Features


window.

3) Select UNM2000 and click Uninstall/Change.

4) In the displayed Question alert box, click Yes to uninstall the UNM2000.

5) Click OK in the displayed Info alert box.

6) In the displayed Question alert box, click Yes to restart the computer.

68 Version: A
4 Upgrading the UNM2000

u Method 2:

1) Access the UNM2000 installation directory (for example, D:\UNM2000)


and double-click uninstall.exe.

2) In the displayed Question alert box, click Yes to uninstall the UNM2000.

3) Click OK in the displayed Info alert box.

4) In the displayed Question alert box, click Yes to restart the computer.

Version: A 69
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

u Method 3:

1) Click Start in the system menu and click . In the displayed


application list, find and click Uninstall UNM2000 under the UNM2000.

2) In the displayed Question alert box, click Yes to uninstall the UNM2000.

3) Click OK in the displayed Info alert box.

4) In the displayed Question alert box, click Yes to restart the computer.

70 Version: A
4 Upgrading the UNM2000

Subsequent Operation

After uninstalling the UNM2000 and restarting the UNM2000 server, you need to
manually delete the unm2000 folder (D:\unm2000 by default) under the installation
directory of the original UNM2000 version.

4.5 Installing the Upgrade Version

The following introduces how to upgrade the UNM2000.

Prerequisite

The UNM2000 of the original version is uninstalled.

Procedure

1. Install the UNM2000 software according to Installing the UNM2000 Software.

2. Initialize the database table according to Initializing the Database Table and
then restart the computer.

3. Check and start the UNM2000 relevant services according to Checking


Services.

4.6 Importing the Configuration Data

After completing the upgrade of the UNM2000 version, you need to import the
configuration data.

Version: A 71
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Prerequisite

u The UNM2000 relevant services are started.

u If the configuration data are backed up on the FTP server, ensure that the FTP
server can be normally connected.

Procedure

1. Double-click the browser icon, type http://server end IP address: 52302/


nmtool/ in the address bar of the browser, and then press the Enter key to
access the login GUI of the UNM2000 management tool.

You can also log into the UNM2000 client, and select System→UNM
Management Tool to access the login GUI of the UNM2000 network
management tool.

2. Type the username and password (both are Admin by default, case sensitive)
on the login GUI , and click Login.

3. Select all services on the process management GUI, click Stop, and then click
OK in the displayed alert box.

4. After the status of each service turns to Stopped, click Import/Export to


access the configuration import / export GUI.

5. Click import, select the file to be imported, and then click OK.

72 Version: A
4 Upgrading the UNM2000

6. In the displayed Import Successful alert box, click OK.

7. Enter the path unm2000/server/bin, run the configuration check tool


unmenvcheck till the running is completed.

The tool running succeeds when the contents as shown below in the figure are
displayed.

Version: A 73
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

8. Click Process in the UNM2000 network management tool, select all services,
and click Start to start all the services.

4.7 Verifying the Upgrade of the Server End

The following introduces how to verify the upgrade of the server end.

Prerequisite

The Java cache of the original client should be cleared. Follow the steps below to
clear the Java cache.

1. Run the javacpl.exe file in the C:\Program Files\Java\jre6\bin folder of the


client to display the Java Control Panel dialog box.

2. In the Java Control Panel dialog box, click View next to Settings to display
the Java Cache Viewer dialog box.

74 Version: A
4 Upgrading the UNM2000

3. Select the application program and click to delete the Java cache.

Procedure

1. Double-click the client shortcut icon .

2. Click Yes in the Update confirmation alert box that appears to update the
client version.

3. Wait till the update is completed. In the displayed Log into UNM2000 dialog
box, type the username and password (both are admin by default), and type
the IP address of the corresponding server in Server. Then click Login.

Note:

If the UNM2000 can be logged in successfully, the server end is


upgraded successfully.

Version: A 75
5 FAQ

The following introduces the FAQs in installing and uninstalling the UNM2000.

How to View the Installation / Uninstallation Logs

How to View the Java Version

How to Uninstall the MySQL Database

How to Uninstall the Tomcat

How to View the Occupation of System Ports

New Alarms Failed to Be Reported in Real Time / New ONU List Failed to Be
Refreshed

76 Version: A
5 FAQ

5.1 How to View the Installation / Uninstallation


Logs
Problem

If errors occur during the installation / uninstallation, how to view the installation /
uninstallation logs?

Solution

Do as follows:

1. Access the UNM2000 installation directory (for example, D:\UNM2000).

2. Open the install or uninstall file and view the recorded logs.

5.2 How to View the Java Version


Problem

How to View the Java Version

Solution

On the Windows OS, follow the steps below to view the Java version:

1. Select Start→Run, and type cmd in the Open text box of the dialog box that
appears, as shown below.

2. Click OK, and type java -version in the CLI window to view the version
information.

Version: A 77
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

On the SUSE Linux OS, follow the steps below to view the Java version:

1. Right-click the desktop and select Open in Terminal from the shortcut menu to
display the Terminal window.

2. Type java -version to view the version information.

5.3 How to Uninstall the MySQL Database


Problem

How to uninstall the MySQL database?

Solution

Do as follows:

1. Stop the MySQL service.

1) Select Start→Administrative Tools→Services to open the Service


window.

2) Right-click the MySQL service and select Stop.

2. Delete the MySQL service.

78 Version: A
5 FAQ

1) Select Start→Run, and type cmd in the Open text box of the dialog box
that appears, as shown below.

2) Click OK to display the CLI window and then run the following commands
to delete the MySQL service.
C:\Users\Administrator>d:
D:\>cd mysql\bin
D:\MySQL\bin>mysqld.exe-remove

When Service successfully removed is displayed, the MySQL service


has been deleted, as shown below.

5.4 How to Uninstall the Tomcat


Problem

How to uninstall the Tomcat?

Version: A 79
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

Solution

Do as follows:

1. Select Start→Run, and type cmd in the Open text box of the dialog box that
appears, as shown below.

2. Click OK to display the CLI window and then run the following commands to
delete the Tomcat service.
C:\Users\Administrator>d:
D:\>cd ApacheTomcat\bin
D:\ApacheTomcat\bin>service.bat remove

When The service ‘Tomcat6’ has been removed is displayed, the Tomcat
service has been deleted, as shown below.

3. Delete the D:\ApacheTomcat file folder.

80 Version: A
5 FAQ

5.5 How to View the Occupation of System Ports


Problem

How to view the occupation of system ports?

Solution

Do as follows:

1. Select Start→Run, and type cmd in the Open text box of the dialog box that
appears, as shown below.

2. Click OK, and type netstat-nao in the CLI window to view the occupation of
system ports.

Version: A 81
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

5.6 New Alarms Failed to Be Reported in Real


Time / New ONU List Failed to Be Refreshed
Problem

The SNMP TRAP is not configured properly. As as result, the new alarms fail to be
reported in real time, or the new ONU list cannot be refreshed in a timely manner.

Solution

Do as follows to check and configure the SNMP TRAP properly:

1. Check the Equipment Management IP in the Manager Properties window,


and set it to the IP address of the server communicating with the device.

2. Check whether the Read the Community Name / Write the Community
Name (default value is adsl) has been configured in the SNMP Parameter
Template Management. Make sure this template has been bound with the
specified NE.

82 Version: A
5 FAQ

3. Perform the following checks and configurations to each NE in the EMS


configuration:

1) Open the NE manager and select Configuration→Local Service


Configuration→PON service→Initialize.

2) Select SNMP Trap Receiver IP, and add an entry. Set the IP Address to
the IP address of the server communicating with the device.

3) Select SNMP System Time Config, and set the NMS Server Address.

Note:
If the EMS server address is unknown, you can set the IP address to
0.0.0.0.

Version: A 83
UNM2000 Network Convergence Management System V2.0R4 Standalone System Installation Guide (Based on
Windows)

4) Select Time Calibration, and make sure that the time calibration is
successful.

84 Version: A
Appendix A Abbreviations

BML Business Management Layer

BMS Business Management System

Common Object Request Broker


CORBA
Architecture
CPU Central Processing Unit

DCC Data Communication Channel


DCN Data Communication Network
DDN Digital Data Network

EML Element Management Layer

EMS Element Management System

EPON Ethernet Passive Optical Network

GPON Gigabit-Capable Passive Optical Network

FTP File Transfer Protocol


GE Gigabit Ethernet

GNE Gate Network Element


GUI Graphic User Interface

IP Internet Protocol
International Telecommunication Union-
ITU-T
Telecommunication Standardization Sector
NE Network Element
NEL Network Element Level
NML Network Management Layer

NMS Network Management System

OLT Optical Line Terminal

ONT Optical Network Terminal

ONU Optical Network Unit

SML Service Management Layer

SMS Service Management System

TCP Transfer Control Protocol


TL1 Transaction Language 1

TMN Telecommunications Management Network

UDP User Datagram Protocol

UPS Uninterrupted Power System

Version: A 85
Product Documentation Customer Satisfaction Survey
Thank you for reading and using the product documentation provided by FiberHome. Please take a moment to
complete this survey. Your answers will help us to improve the documentation and better suit your needs. Your
responses will be confidential and given serious consideration. The personal information requested is used for
no other purposes than to respond to your feedback.

Name
Phone Number
Email Address
Company

To help us better understand your needs, please focus your answers on a single documentation or a complete
documentation set.

Documentation Name
Code and Version

Usage of the product documentation:


1. How often do you use the documentation?
□ Frequently □ Rarely □ Never □ Other (please specify)
2. When do you use the documentation?
□ in starting up a project □ in installing the product □ in daily maintenance □ in trouble
shooting □ Other (please specify)
3. What is the percentage of the operations on the product for which you can get instruction from the
documentation?
□ 100% □ 80% □ 50% □ 0% □ Other (please specify)
4. Are you satisfied with the promptness with which we update the documentation?
□ Satisfied □ Unsatisfied (your advice)
5. Which documentation form do you prefer?
□ Print edition □ Electronic edition □ Other (please specify)
Quality of the product documentation:
1. Is the information organized and presented clearly?
□ Very □ Somewhat □ Not at all (your advice)
2. How do you like the language style of the documentation?
□ Good □ Normal □ Poor (please specify)
3. Are any contents in the documentation inconsistent with the product?
4. Is the information complete in the documentation?
□ Yes
□ No (Please specify)
5. Are the product working principles and the relevant technologies covered in the documentation sufficient for
you to get known and use the product?
□ Yes
□ No (Please specify)
6. Can you successfully implement a task following the operation steps given in the documentation?
□ Yes (Please give an example)
□ No (Please specify the reason)
7. Which parts of the documentation are you satisfied with?

8. Which parts of the documentation are you unsatisfied with?Why?

9. What is your opinion on the Figures in the documentation?

□ Beautiful □ Unbeautiful (your advice)

□ Practical □ Unpractical (your advice)

10. What is your opinion on the layout of the documentation?


□ Beautiful □ Unbeautiful (your advice)
11. Thinking of the documentations you have ever read offered by other companies, how would you compare
our documentation to them?
Product documentations from other companies:

Satisfied (please specify)

Unsatisfied (please specify)

12. Additional comments about our documentation or suggestions on how we can improve:

Thank you for your assistance. Please fax or send the completed survey to us at the contact information
included in the documentation. If you have any questions or concerns about this survey please email at
edit@fiberhome.com

S-ar putea să vă placă și