Documente Academic
Documente Profesional
Documente Cultură
1 WMPT
This describes the WCDMA Main Processes and Transmission unit (WMPT). It is the BBU3900
main control and transmission board that processes the signals and manages the resources for
other boards.
Panel
Functions
Processes signaling and manages resources for other boards in the BBU3900
Provides USB ports, one of which facilitates automatic base station upgraded when a USB
disk is inserted during software installation and data configuration
Provides one FE electrical port and one FE optical port which support the IP protocol
LEDs
In addition to the previous three LEDs, the WMPT has another six LEDs indicating the connection
status of the FE optical port, FE electrical port, and the commissioning Ethernet port. The six LEDs
have no silk screen and are on both sides of each of the three ports. Figure 2 shows the LEDs
beside the three ports.
Figure 2 LEDs beside the three ports on the WMPT
Ports
DIP Switches
The WMPT has two DIP switches: SW1 for setting the E1/T1 working mode and SW2 for setting
the protection grounding for the E1/T1 cables receiving 4-way signals. Figure 3 shows the DIP
switches on the WMPT.
1 2 3 4
ON ON ON ON The E1
impedance is
set to 75 ohms.
1 2 3 4
ON ON ON ON Unbalanced
Mode
CAUTION:
All the DIP bits of SW2 are set to OFF by default. When four E1 links are faulty, you should set all
the DIP bits of SW2 to ON so that the faults are rectified.
Parent topic: Boards and Module of the BBU3900