Sunteți pe pagina 1din 11

NGTRiiAGE-partner(eng) REV: 27.0.

19 BUILD DATE: 081618


*******************************************************************************
SP LOG MESSAGE POPULARITY INFORMATION
*******************************************************************************

Total SPA SPB Ercode Message


------ ------ ------ -------- --------------------
46373 17424 28949 78a Write cache enable pending
10691 6777 3914 7115000d PSM File "
10021 6608 3413 745c Either the Storage Processor (SP) or the Disk
Processor Enclosure (DPE) is not working properly. Contact your service provider
for further assistance.
7860 0 7860 40008031 Failing Command:
2532 2337 195 801 Soft SCSI Bus Error
2508 2041 467 63f Resume PROM read succeeded.
1266 1266 0 741e Power/cooling module (Power Supply 1) is not
receiving ac power. The enclosure will continue to receive power from the other
working power supply.
1250 1220 30 71200007 Found package
1067 971 96 60a A logical unit has been enabled
1013 809 204 71510000 Info:
867 797 70 76004101 Found a warning during POST:
703 664 39 803 Recommend Disk Replacement
653 178 475 a07 CRU Powered Down
637 162 475 7127897c Disk failed or was physically removed.TLA Part Number
is
548 358 190 904 VSC Shutdown/Removed [Faulted] 0 0
4
503 300 203 6c1 BE Fibre Loop Down 0 0
7
458 202 256 40000001
457 442 15 6a1 CRU ready. [sn
412 400 12 71170019 SFP Inserted for logical port
377 365 12 782 FRUMON Revision:
342 333 9 a25 Enclosure state change [missing->ok] 1 0
0
332 47 285 67b Database region rebuild started
330 46 284 67c Database region rebuild completed 1 ffff00
313 304 9 0
299 38 261 78b Drive physically removed from slot 0 0
0
297 36 261 78c Drive physically inserted into slot 0 0
0
277 212 65 867 Resume PROM read failed.
250 244 6 3 User configuration data for parameter CO
250 244 6 71240014 Creating root partition \Device
250 244 6 71240016 Unit State: ENABLED
225 207 18 71170009 Fibre Channel loop up on logical port
212 206 6 6e1 FE Fibre Port Enabled 0 0
0
211 43 168 613 CRU Unit Equalize Started [to 0_0_9 ALU
205 199 6 41000001
200 191 9 7117001b SFP Diagnostic condition "Received power low alarm"
detected for logical port
200 194 6 76000100
194 190 4 2006 Able to read events from the Windows
183 157 26 1
181 0 181 71100001 Lost contact with 5d50a0bb60010650:0 on conduit
179 0 179 71310007 CMID Transport Device 0:
177 0 177 631 VSC Installed 0 0
0
172 103 69 714 Read cache enabled 0 0
0
167 26 141 605 CRU Unit Rebuild Halted [to 0_0
155 0 155 944 Hard Peer Bus Error
142 76 66 655 SPS Enabled - Checking Config
140 75 65 698 Battery Testing In Progress [Testing] 0 0
80
134 131 3 1775 The Event log service was started.
134 131 3 1779 Microsoft (R) Windows (R) 5.01. 2600 Service Pack 2
Uniprocessor Free.
133 71 62 637 SPS Recharging 0 0
0
125 122 3 9 Broadcom NetLink (TM) Gigabit Ethernet: Network
controller configured for 100Mb full-duplex link.
125 122 3 f Broadcom NetLink (TM) Gigabit Ethernet: Driver
initialized successfully.
125 122 3 71110002 Compiled on Dec 7 2011 at 22:28:42, Free (Retail)
Build.
125 122 3 71110003 DriverEntry() returned 0.
125 122 3 71120002 Compiled on Dec 7 2011 at 22:28:54, Free (Retail)
Build.
125 122 3 71120003 DriverEntry() returned at 0.
125 122 3 71190002 My SP ID is 0x5d50a0bb60010650
125 122 3 71200002 Compiled at Dec 7 2011.
125 122 3 71200003 DriverEntry() returned 0.
125 122 3 71200006 Current (incremented) reboot count is 1.
125 122 3 7124000f NT Mirror Driver Compiled on Dec 7 2011 23:08:58 Free
(Retail) Build 00_00_01.
125 122 3 71240010 DriverEntry() exiting with status 0.
125 122 3 71470003 Creating Drive Object 60.
114 66 48 7400 Disk drive (Enclosure
107 104 3 940 Fault reported by SPS. Replace the SPS. 0 0
100
106 103 3 3e8 Telnet Service was started successfully.
106 103 3 601 SP Powerup 0
4d495300 c8
106 103 3 751 Initialization of private space on all the disks has
started 0 0 ffffffff
106 103 3 753 Initialization of private space on all the disks has
completed 0 0 ffffffff
106 23 83 799 Peer Requested Drive Power Down. 0 0

106 103 3 76000001 newSP inhibits I/O.


105 102 3 41000000 Starting service: K10Governor
105 102 3 41000600 DynStrings:WaitService started
104 101 3 41000002 Starting
104 101 3 41000100 DumpManager started
104 101 3 41000101 No new dump found
103 100 3 41000500 PeerWatch started
101 98 3 41000300 LockWatch started
100 97 3 71214000 ktconsService log: Waiting for signal from the
Governor to take ktrace dump.
99 54 45 638 SPS Enabled
97 95 2 2000 Application Starting Up
95 0 95 7403 Storage Processor (Part No. N/A, Serial No. N/A) is
not working properly. Write cache will be disabled. Verify that servers have access
through the other SP. Contact service provider for further assistance.
91 0 91 744e The peer storage processor has been powered off.
90 0 90 a23 Peer SP Down. 3 0
0
90 87 3 4700 '128.221.2
89 0 89 71310008 CMID Transport Device 0: Gate 0 connects to SP ID
0x5d50a0bb60010650:0 (Signature 0x38fb71)
84 3 81 743a Storage system management software can no longer
manage Storage Processor (SP
78 0 78 7402 Power/cooling module (Power Supply 1) (Part No.
76 13 63 741b Disk was removed from the storage system.
72 35 37 720f The storage system has disabled its write cache, most
likely because of a hardware issue.
69 25 44 7210 Write cache is temporarily disabled because the
Standby Power Supply (SPS) is testing or charging. When finished, write cache will
be re-enabled. Change the battery test time for this system if required.
66 0 66 643 SP Initializing 0 0
0
66 0 66 644 SP Inserted 0 0
0
63 0 63 40004001 #THREADO: Peer died in Run: 1073774611
63 60 3 71000001 The SnapView Driver has started, compile info: Jul 16
2008 11:07:18 Free (Retail) Build.
63 60 3 71170004 TDD activated with ScsiTarg.
63 60 3 71280001 The RollBack Driver has started; compile info: Jul 16
2008 11:13:52 Free (Retail) Build.
62 9 53 602 CRU Enabled [swap 0
62 59 3 71160000 DiskTarg (TDD) starting.
62 59 3 71170003 TDD linked with ScsiTarg.
61 58 3 71130002 Compiled on Dec 7 2011 at 22:28:48, Free (Retail)
Build.
61 58 3 71130003 DriverEntry() returned 0.
61 58 3 71150002 Compiled on Dec 7 2011 at 22:29:13, Free (Retail)
Build.
61 58 3 71150003 DriverEntry() returned 0.
61 58 3 71150005 Read and processed default Persistent Container
\Device\CLARiiON_PSM
60 0 60 7432 Link Control Card is not communicating with some of
its disk drives, most likely due to a disk drive problem. The affected drives will
have their fault LEDs on.
58 1 57 7404 Standby Power Supply (SPS Enclosure 0 SPS A) is not
working. Write cache will be disabled. Verify power and serial cables are connected
properly. If SPS is not charging and problem persists, contact service provider.
57 36 21 6a0 Disk soft media error [Recovered error (on-drive
ECC)] 0 0 22
53 0 53 712707b6 SP Status:(44) Application running.
49 2 47 606 Unit Shutdown for Trespass [ALU
37 0 37 873 Flare's ATM detects one CMI connection is down. 0
0 0
36 0 36 7127ca2d SP is in a hung state. The state code is:
34 7 27 603 CRU Unit Rebuild Started [to 0
34 6 28 614 CRU Unit Equalize Complete [to 0_0_9 ALU
28 3 25 604 CRU Unit Rebuild Complete [to 0
26 26 0 90d SPS Removed 0 0
20000
19 5 14 6a2 Hot Spare is now replacing a failed drive. [swap 0
19 5 14 7a7 Drive removed, seen by either SP, acknowledged by
both SPs completes. 0
19 5 14 906 Unit Shutdown [ALU 2
19 0 19 744f Peer storage processor (SP) did not power up because
a hardware component is not functioning properly or is missing. Servers with paths
to both SPs will now have access to LUNs through the working SP.
19 7 12 71170008 Fibre Channel loop down on logical port
17 3 14 67d All rebuilds for a FRU have completed 0
ffffffff ffffffff
16 4 12 67e All equalizes for a FRU have completed 0
ffffffff ffffffff
16 4 12 6a3 Hot Spare is no longer replacing a failed drive.
[swap 0_0_5] 0 9 5
14 2 12 7a5 Drive removed, seen by local SP. [queued] 0
12 0 12 755 Logical format of the disk was incorrect and was
reconstructed successfully. 0 0 83
12 0 12 7127ca2a SP is faulted. Fault Code: 0. FRU: SP board - Part
Number: SeeNavi should be replaced.

*******************************************************************************
KTRACE LOG MESSAGE POPULARITY INFORMATION
*******************************************************************************

Total SPA SPB Message


------ ------ ------ --------------------
2439 1185 1254 SASBE-
1260 630 630 dba_fru_get_bound_original_position; Fru
1149 519 630 Disk Powerup. Fru
615 316 299 Enter
615 316 299 Exit
404 190 214 RB COMPLETE RG:
381 183 198 cm_fru_edge_cache_region, no edge cache control on drive
330 133 197 Enclosure (
322 148 174 Clear init flag. fru
305 165 140 ca_ok_to_enable_cache() fails. Cache hardware not OK. Status:
276 0 276 cm_en_dis_system_cache, cm_element state
208 104 104 current_dde_rev
204 102 102 ProcessMasterDdeRead Fru
191 89 102 HOST_FRU_ENABLED fru=
185 86 99 cm_assign_invalidate_unit_edge_cache.FRU:
180 90 90 Odbs_Start(): START: Single Disk Op: fru
164 82 82 Data Area Locking:createLock() PLock
164 82 82 Odbs_ProcessDiskDead(): P
152 74 78 cm_set_disk_pwr_led: fru
142 71 71 deading drive. fru:
138 0 138 Automode --> Sending pio ena/dis write cache request...
138 69 69 selection error. fru:
137 67 70 DEAD DISK: md dead msg, FRU
135 64 71 setup_write_state(), encl:
132 66 66 Odbs_PopulateMasterDde(): INSERT
126 0 126 Automode Cache Mgr --> Trying to ENABLE cache! (Try:
122 46 76 0xffffffff
122 61 61 3
120 59 61 Odbs_Start(): STOP: Single Disk Op: fru
120 56 64 cm_env_handle_write_response, Encl.:
112 56 56 Odbs_PopulateMasterDde(), REG_INSERT : OK
110 34 76 -> scsiSts
110 34 76 IO_DEVICE_ERROR: path
109 33 76 ASC
108 53 55 DEAD DISK: handle dead disk, FRU
108 53 55 DEAD DISK: send remove to pfsm, Fru
101 50 51 set DH_FULL_INIT, fru
91 42 49 LCC Getlog - processing getlog response
91 42 49 LCC Getlog - sending VD_REQUEST_COMPLETE
91 42 49 end of scsi read buffer
91 42 49 scsi read buffer command
91 42 49 send SCSI read buffer command
86 43 43 rg_open_dh - group:
84 42 42 cm_pup_sm_check_sys_fru_drive_type() log_fru
76 38 38 Drive::instance called for FRU
76 38 38 SFD Creating Drive Object
76 36 40 sent RAID_GROUP_STARTUP group
74 37 37 Creating SAS Drive at
74 37 37 Maybe Powerup complete.Fru:
72 36 36 LUSM, a notification has been queued for LU
60 30 30 2
55 18 37 Setting max read xfer to
51 27 24 Rebuild: FRU
50 25 25 K1
50 29 21 TPM Hndle API Event: cntx=
47 23 24 Starting Serial Read of All fields for Fru PROM ID:
46 1 45 MirrorCheckSenseData() Disk
45 22 23 Serial Read completed. field:
45 22 23 cm_env_diagnose_encl_state Encl pos.
42 21 21
42 21 21 <IdmDatabaseObject>
40 20 20 cld_open Unit:
39 21 18 Enclosure (-
38 19 19 psmDataAreaFindOrCreateDataArea()
36 18 18 Auto Insert Volume
36 18 18 LUSM, queue up notification for LU
36 18 18 No Tr Execute IownLun:
36 18 18 Sent PResv Info for DLU
36 16 20 \Device\CLARiiONdisk1
36 17 19 cm_env_process_pending_removes: fru =
36 18 18 cm_send_aep_continue; send ready event to hostside for LU
36 18 18 not ready error. fru:
36 18 18 read_image_file: subscript_id =
36 18 18 read_image_file: subscript_id=
35 16 19 cm_env_update_enclosure_states, Encl.:
32 22 10 Error
32 16 16 cm_env_check_rp_read_pending(). A Serial Read is pending on
Bus:
31 15 16 cm_lcc_any_encl_flt, Reason changed, encl
30 0 30 IrpC::executeDriveRequest:reassignBlocks (IRP =
30 0 30 MirrorRemapComplete() (IRP=
30 15 15 validate_image_header: subscript_id=
28 14 14 cm_fru_sig_peer_msg, fru
27 27 0 Initializing List
27 27 0 TestForBattery, PSA1 DC Detected
27 13 14 cm_env_diagnose_encl_state fan fault in encl
26 16 10 Lun
25 0 25 CM(CM_SEND_DH_INQ) disk
25 0 25 sending spinup to fru:
24 12 12 DriverEntry
24 12 12 MirrorUpdatePartitions: Matched \Device\Harddisk0\DP(
22 16 6 Completed Tr Execute ioctl to WWN
22 11 11 OSW SFP_EVENT - type:
22 16 6 Trespass IownLun:
22 16 6 Trespass Log Suppress is FALSE
21 9 12 :CallPsm() Exiting IoControlCode
21 9 12 :CallPsm() IoControlCode
21 10 11 Disk
21 10 11 New Read: flt_bmask:
21 10 11 Processing Read Response for Encl:
21 10 11 Prv Read: flt_bmask:
20 12 8 QE4 fc_tl_write_itr fm_
20 12 8 TPM Notify: st=
20 10 10 Unexpected Serial Read reply. Encl Pos.:
20 10 10 cm_env_checkForTelcoPowerSupplies: Retry count is
20 10 10 cm_env_init_encl Init encl_desc struct. Encl:
20 10 10 cm_env_init_exp Init exp_element struct. exp_id:
20 10 10 cm_lcc_serial_cmds: Err. Resp. Error:
20 10 10 sendErrorPackage() called
19 7 12 0x0
19 7 12 0x1
19 7 12 0x2
19 7 12 0x3
19 7 12 0x4
19 7 12 0x5
19 7 12 0x6
19 7 12 0x7
19 7 12 0x8
19 7 12 0x9
19 11 8 FRU:
19 8 11 cm_exptrace_sysio_expander_callback: ACK received from sysio
for encl pos
19 8 11 system_io_file_write_ex, ZwWriteFile Success, status =
19 8 11 system_io_fill_sgl_param, writing to pipe
19 7 12 tabl_index, encl_num, cable_pos, state, uid, sas_address,
peer_state
18 9 9 :validate_image_header: subscript_id =
18 12 6 Assign Notification WWN:
18 9 9 Connect to \Device\CLARiiONdisk1
18 9 9 IRP_MJ_PNP IRP_MN_QUERY_DEVICE_RELATIONS for DevObj=
18 12 6 Signal Assign Thread. SignaledCount
18 9 9 validate_image_header: subscript_id =
18 9 9 validate_image_header: subscript_id =
17 6 11 0x5d5
17 6 11 0xdc2
17 6 11 0xdd2
17 6 11 0xf4
17 7 10 :CreditAllocatedBytes() Size
17 7 10 :DebitAllocatedBytes() Size
17 7 10 HandleCmSpsMsg, updated SpsTestingInfo
17 7 10 HandleCmSpsMsg,msg_code
16 7 9 :AllocateNonPagedPool() Allocated Bytes
16 7 9 :FreeNonPagedPool() Allocated Bytes
16 6 10 FS: drive bypassed, setting keep_fru_dead, fru
16 8 8 IOCTL GET_CONFIG - format
16 8 8 MirrorLoginAliasedDisk: Disk
16 8 8 RegistryQueryFeatureLimit() Compat level:
16 8 8 UPDATE_EXPANDER_LIST
16 8 8 bus reset error. fru:
16 8 8 cm_env_lcc_error_retry Reissue Async cmd:
16 7 9 cm_env_process_pending_removes. Encl:
16 8 8 getlog soft error. fru:
15 8 7 LCC resume PROM transfer failed. Status
14 7 7 ListRules()
14 7 7 Odbs_PopulateMasterDde(), SWAP_IN_INSERT : OK
14 7 7 Odbs_PopulateMasterDde(), SWAP_IN_RECEIVED_FLAG PID:
14 7 7 Rebuild: Pri LUN
14 7 7 cm_fru_sig_update_complete fru
14 7 7 power supply resume PROM transfer failed ff,
13 12 1 Requested DLU object not found for XLU
13 4 9 State Machine start params:
13 8 5 TrespassGetGeometry ReIssue Notify Irp: \Device\CLARiiONdisk1
13 4 9 cm_enclsm_set_rule_level
13 4 9 encl SM alg:
13 4 9 encl SM flags:
13 4 9 encl position:
13 4 9 encl sas addr high:
13 4 9 encl sas addr low:
13 4 9 encl tbl index:
13 4 9 encl unique id:
13 4 9 polled encl number:
12 6 6 2a: IoCallDriver Status
12 6 6 2b: IoCallDriver Status
12 6 6 2c: IoCallDriver Status
12 6 6 2d: IoCallDriver Status
12 6 6 2e: IoCallDriver Status
12 6 6 2f: IoCallDriver Status
12 6 6 3a: IoCallDriver Status
12 6 6 3b: IoCallDriver Status
12 0 12 Automode Cache Mgr --> Already allocated, going ENABLED!
12 0 12 Automode Cache Mgr --> State transition: AM_CMGR_PENDING =>
AM_CMGR_WAIT_ENABLE.
12 8 4 CALLBACK: LINK UP - connection type
12 6 6 Change in Drive status. Encl:
12 5 7 DEAD DISK: Fru
12 5 7 DEAD DISK: hot spare dead - send remove to peer, Fru
12 5 7 DEAD DISK: hot spare dead, Fru
12 8 4 DVM Disc Comp- Dev List Size:
12 6 6 FS: resetting unstable drive parameters for FRU
12 6 6 IRP_MJ_PNP IRP_MN_DEVICE_USAGE_NOTIFICATION for DevObj=
12 6 6 IRP_MJ_PNP IRP_MN_START_DEVICE for DevObj=
12 6 6 SyncPSMIoctl() returning
12 8 4 TPM Lnk Up: state=
12 5 7 cm_env_handle_write_response, Encl.:
12 6 6 cppshDriver.cpp cppshExecConstructors
12 6 6 cppshExecConstructors
12 6 6 fc_tl_handle_fm_int: speed neg is active sn_
11 0 11 Automode Cache Mgr --> State transition: AM_CMGR_WAIT_ENABLE
=> AM_CMGR_PENDING.
11 0 11 Automode Cache Mgr --> Stuck in state: AM_CMGR_WAIT_ENABLE,
giving up.
11 3 8 ESM: get_encl_tbl_index, matching uid to index
11 8 3 FRU: (HS)
11 3 8 cm_env_check_add_encl
10 5 5 FRU REMOVE - received a message from the peer to power down
FRU
10 5 5 GetPortConfig setting PortIsValid:
10 5 5 IRP_MJ_PNP IRP_MN_QUERY_PNP_DEVICE_STATE for DevObj=
10 5 5 Loop resumed on bus
10 5 5 No P(x) value set for port (in registry).
10 5 5 SpidFSRAnalyzeSMIStatus() - SMBus Status: Ok
10 5 5 Updated rev of dbo type
10 5 5 cm_dh_resume. Resume Loop. Bus:
10 5 5 cm_dh_suspend. Hold Loop. Bus:
*******************************************************************************
SP LOG MESSAGE EVENT CODE SUMMARY
*******************************************************************************

Total SPA SPB Ercode Message


------ ------ ------ -------- --------------------
313 304 9 0
183 157 26 1
250 244 6 3 User configuration data for parameter CO
125 122 3 9 Broadcom NetLink (TM) Gigabit Ethernet: Network
controller configured for 100Mb full-duplex link.
125 122 3 f Broadcom NetLink (TM) Gigabit Ethernet: Driver
initialized successfully.
106 103 3 3e8 Telnet Service was started successfully.
106 103 3 601 SP Powerup 0
4d495300 c8
62 9 53 602 CRU Enabled [swap 0
34 7 27 603 CRU Unit Rebuild Started [to 0
28 3 25 604 CRU Unit Rebuild Complete [to 0
167 26 141 605 CRU Unit Rebuild Halted [to 0_0
49 2 47 606 Unit Shutdown for Trespass [ALU
1067 971 96 60a A logical unit has been enabled
211 43 168 613 CRU Unit Equalize Started [to 0_0_9 ALU
34 6 28 614 CRU Unit Equalize Complete [to 0_0_9 ALU
7 0 7 621 Background Verify Started [ALU 2048] 0
ffff0800 8000000
7 0 7 622 Background Verify Complete [ALU 2048] 0
ffff0800 8000000
177 0 177 631 VSC Installed 0 0
0
133 71 62 637 SPS Recharging 0 0
0
99 54 45 638 SPS Enabled
2508 2041 467 63f Resume PROM read succeeded.
66 0 66 643 SP Initializing 0 0
0
66 0 66 644 SP Inserted 0 0
0
142 76 66 655 SPS Enabled - Checking Config
332 47 285 67b Database region rebuild started
330 46 284 67c Database region rebuild completed 1 ffff00
17 3 14 67d All rebuilds for a FRU have completed 0
ffffffff ffffffff
16 4 12 67e All equalizes for a FRU have completed 0
ffffffff ffffffff
140 75 65 698 Battery Testing In Progress [Testing] 0 0
80
57 36 21 6a0 Disk soft media error [Recovered error (on-drive
ECC)] 0 0 22
457 442 15 6a1 CRU ready. [sn
19 5 14 6a2 Hot Spare is now replacing a failed drive. [swap 0
16 4 12 6a3 Hot Spare is no longer replacing a failed drive.
[swap 0_0_5] 0 9 5
503 300 203 6c1 BE Fibre Loop Down 0 0
7
212 206 6 6e1 FE Fibre Port Enabled 0 0
0
172 103 69 714 Read cache enabled 0 0
0
106 103 3 751 Initialization of private space on all the disks has
started 0 0 ffffffff
106 103 3 753 Initialization of private space on all the disks has
completed 0 0 ffffffff
12 0 12 755 Logical format of the disk was incorrect and was
reconstructed successfully. 0 0 83
377 365 12 782 FRUMON Revision:
46373 17424 28949 78a Write cache enable pending
299 38 261 78b Drive physically removed from slot 0 0
0
297 36 261 78c Drive physically inserted into slot 0 0
0
106 23 83 799 Peer Requested Drive Power Down. 0 0

14 2 12 7a5 Drive removed, seen by local SP. [queued] 0


5 3 2 7a6 Drive removed, seen by peer SP. [master
19 5 14 7a7 Drive removed, seen by either SP, acknowledged by
both SPs completes. 0
2532 2337 195 801 Soft SCSI Bus Error
703 664 39 803 Recommend Disk Replacement
277 212 65 867 Resume PROM read failed.
37 0 37 873 Flare's ATM detects one CMI connection is down. 0
0 0
548 358 190 904 VSC Shutdown/Removed [Faulted] 0 0
4
19 5 14 906 Unit Shutdown [ALU 2
26 26 0 90d SPS Removed 0 0
20000
107 104 3 940 Fault reported by SPS. Replace the SPS. 0 0
100
155 0 155 944 Hard Peer Bus Error
653 178 475 a07 CRU Powered Down
90 0 90 a23 Peer SP Down. 3 0
0
342 333 9 a25 Enclosure state change [missing->ok] 1 0
0
134 131 3 1775 The Event log service was started.
134 131 3 1779 Microsoft (R) Windows (R) 5.01. 2600 Service Pack 2
Uniprocessor Free.
97 95 2 2000 Application Starting Up
194 190 4 2006 Able to read events from the Windows
90 87 3 4700 '128.221.2
72 35 37 720f The storage system has disabled its write cache, most
likely because of a hardware issue.
69 25 44 7210 Write cache is temporarily disabled because the
Standby Power Supply (SPS) is testing or charging. When finished, write cache will
be re-enabled. Change the battery test time for this system if required.
114 66 48 7400 Disk drive (Enclosure
78 0 78 7402 Power/cooling module (Power Supply 1) (Part No.
95 0 95 7403 Storage Processor (Part No. N/A, Serial No. N/A) is
not working properly. Write cache will be disabled. Verify that servers have access
through the other SP. Contact service provider for further assistance.
58 1 57 7404 Standby Power Supply (SPS Enclosure 0 SPS A) is not
working. Write cache will be disabled. Verify power and serial cables are connected
properly. If SPS is not charging and problem persists, contact service provider.
76 13 63 741b Disk was removed from the storage system.
1266 1266 0 741e Power/cooling module (Power Supply 1) is not
receiving ac power. The enclosure will continue to receive power from the other
working power supply.
60 0 60 7432 Link Control Card is not communicating with some of
its disk drives, most likely due to a disk drive problem. The affected drives will
have their fault LEDs on.
84 3 81 743a Storage system management software can no longer
manage Storage Processor (SP
91 0 91 744e The peer storage processor has been powered off.
19 0 19 744f Peer storage processor (SP) did not power up because
a hardware component is not functioning properly or is missing. Servers with paths
to both SPs will now have access to LUNs through the working SP.
10021 6608 3413 745c Either the Storage Processor (SP) or the Disk
Processor Enclosure (DPE) is not working properly. Contact your service provider
for further assistance.
458 202 256 40000001
63 0 63 40004001 #THREADO: Peer died in Run: 1073774611
7860 0 7860 40008031 Failing Command:
105 102 3 41000000 Starting service: K10Governor
205 199 6 41000001
104 101 3 41000002 Starting
104 101 3 41000100 DumpManager started
104 101 3 41000101 No new dump found
101 98 3 41000300 LockWatch started
103 100 3 41000500 PeerWatch started
105 102 3 41000600 DynStrings:WaitService started
63 60 3 71000001 The SnapView Driver has started, compile info: Jul 16
2008 11:07:18 Free (Retail) Build.
181 0 181 71100001 Lost contact with 5d50a0bb60010650:0 on conduit
125 122 3 71110002 Compiled on Dec 7 2011 at 22:28:42, Free (Retail)
Build.
125 122 3 71110003 DriverEntry() returned 0.
125 122 3 71120002 Compiled on Dec 7 2011 at 22:28:54, Free (Retail)
Build.
125 122 3 71120003 DriverEntry() returned at 0.
61 58 3 71130002 Compiled on Dec 7 2011 at 22:28:48, Free (Retail)
Build.
61 58 3 71130003 DriverEntry() returned 0.
61 58 3 71150002 Compiled on Dec 7 2011 at 22:29:13, Free (Retail)
Build.
61 58 3 71150003 DriverEntry() returned 0.
61 58 3 71150005 Read and processed default Persistent Container
\Device\CLARiiON_PSM
10691 6777 3914 7115000d PSM File "
62 59 3 71160000 DiskTarg (TDD) starting.
62 59 3 71170003 TDD linked with ScsiTarg.
63 60 3 71170004 TDD activated with ScsiTarg.
19 7 12 71170008 Fibre Channel loop down on logical port
225 207 18 71170009 Fibre Channel loop up on logical port
412 400 12 71170019 SFP Inserted for logical port
200 191 9 7117001b SFP Diagnostic condition "Received power low alarm"
detected for logical port
125 122 3 71190002 My SP ID is 0x5d50a0bb60010650
125 122 3 71200002 Compiled at Dec 7 2011.
125 122 3 71200003 DriverEntry() returned 0.
125 122 3 71200006 Current (incremented) reboot count is 1.
1250 1220 30 71200007 Found package
100 97 3 71214000 ktconsService log: Waiting for signal from the
Governor to take ktrace dump.
125 122 3 7124000f NT Mirror Driver Compiled on Dec 7 2011 23:08:58 Free
(Retail) Build 00_00_01.
125 122 3 71240010 DriverEntry() exiting with status 0.
250 244 6 71240014 Creating root partition \Device
250 244 6 71240016 Unit State: ENABLED
53 0 53 712707b6 SP Status:(44) Application running.
637 162 475 7127897c Disk failed or was physically removed.TLA Part Number
is
12 0 12 7127ca2a SP is faulted. Fault Code: 0. FRU: SP board - Part
Number: SeeNavi should be replaced.
36 0 36 7127ca2d SP is in a hung state. The state code is:
63 60 3 71280001 The RollBack Driver has started; compile info: Jul 16
2008 11:13:52 Free (Retail) Build.
179 0 179 71310007 CMID Transport Device 0:
89 0 89 71310008 CMID Transport Device 0: Gate 0 connects to SP ID
0x5d50a0bb60010650:0 (Signature 0x38fb71)
125 122 3 71470003 Creating Drive Object 60.
1013 809 204 71510000 Info:
106 103 3 76000001 newSP inhibits I/O.
200 194 6 76000100
867 797 70 76004101 Found a warning during POST:

S-ar putea să vă placă și