Sunteți pe pagina 1din 4

Connection Box

▣Features
(A)
lAble to check the status of operation by Counter

Red indicator
lAble to drive multiple sensors by single
power (B)
Timer
lRealization of convenience for wiring or
power line
lWhen use water resistive cover, water (C)
proof structure will be IP67 Temp.
controlle
(When use protection cover, water proof
structure will be IP 66)
(D)
Power
Please read "Caution for your safety" in operation
! controlle
manual before using.

▣Ordering information ▣Type (E)


Panel
meter

PT 4 - 3 D N Appearances Model
DC 2-wire type PT4-2D
(F)
PT4-3DN Tacho/
DC 3-wire type Speed/
2D DC 2-wire type PT4-3DP Pulse
meter
3DN DC 3-wire NPN type DC 2-wire type PT6-2D
3DP DC 3-wire PNP type PT6-3DN
DC 3-wire type (G)
PT6-3DP Display
4 4pcs unit
Connector DC 2-wire type PT8-2D
6 6pcs
PT8-3DN
8 8pcs DC 3-wire type
PT8-3DP (H)
PT Connection Box Sensor
controlle

(I)
▣Specifications Proximit
sensor

PT4-3DN PT6-3DN PT8-3DN


Model PT4-2D PT6-2D PT8-2D
PT4-3DP PT6-3DP PT8-3DP
(J)
Photo
Power supply 12-24VDC electri c
(Operating voltage) (10-30VDC) sensor

Leakage current 0.5mA


Connection life cycle Min. 200 times (K)
Pressur
Cable tensile strength 10kgf(98N)[15s] sensor
Insulation resistance Min. 50MΩ(at 500VDC)
Dielectric strength 1500VAC 50/60Hz for 1minute
(L)
Vibration 1mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 2 hours Rotary
encoder
Shock 500m/s²(50G) in X, Y, Z direction for 3 times
Indicator Power indicator : Green, Operation indicator : Red (M)
5-Phase
Ambient temperature -25 ~ +70℃(at non-freezing status) stepping
motor &
Storage temperature -30 ~ +80℃(at non-freezing status) Driver &
Controlle
Ambient humidity 35 ~ 95%RH
Protection IP67(IEC specification)
Weight Approx. 630g Approx. 690g Approx. 745g
※When using a cover for water-proof : IP67(IEC standards)

I-46
PT Series
▣Dimensions
lPT4-□□ 73 5000
56.5
140
100 10
ø9

4-ø4.5

Unit:mm

98 5000
lPT6-□□ 56.5
140
100 10
ø9

4-ø4.5

Unit:mm

lPT8-□□ 123 5000


56.5
140
100 10
ø9

4-ø4.5

Unit:mm

▣Water resistive cover ▣Protective cover


Form Model Applicable model Form Applicable model
M12
lPT4-□□□ lPT4-□□□
P96-M12-1 lPT6-□□□ lPT6-□□□
lPT8-□□□ lPT8-□□□

※This protection cover is used for protecting unused ※This protection cover is used for protecting unused
connection hole from water or oil etc. connection hole from dust or particle etc.
※If use water resistive cover, IP67 is available. (IP66 is available)
※Please tighten it. ※Please push it into hole.

※Water resistive cover is optional.

I-47
Connection Box
▣Connections
(A)
Counter
DC 2-wire type DC 3-wire type(PNP type) DC 3-wire type(NPN type)
Blue
Blue Blue
(Power-) - -
(Power-) (Power-) - (B)
Brown Brown + Brown
+ Timer
(Power+) Power indicator Connection (Power+) Power
+
LED Connection (Power+) Power indicator Connection
No. indicator LED No. LED No.
Operating 1 1 1
White indicatorLED White Opera ting (C)
4 2 1 4 2 1 White
(Signal 1) ! (Signal 1) ! !
indica tor L ED
4 2 1 Temp.
3 3 (Signal 1) controlle
3
Operating
indicatorLED
Gray 1 1 1
Gray Gray (D)
(Signal 2) @ 4 2 2 (Signal 2) @ 4 2 2
4 2 2
3 (Signal 2) @ Power
3 3 controlle

Pink 1 1 1
Pink Pink (E)
(Signal 3) # 4 2 3 (Signal 3) # 4 2 3 4 2 3
3 3 (Signal 3) # Panel
meter
3

Red 1 1 (F)
Red Red 1 Tacho/
(Signal 4) $ 4 2 4 4 2 4
(Signal 4) $ 4 2 4
3 3 (Signal 4) $ Speed/
Pulse
3 meter

Black 1 1
Black Black 1
(Signal 5) % 4 2 5 (Signal 5) % 4 2 5 (G)
(Signal 5) % 4 2 5 Display
3 3 unit
3

Violet 1 Violet 1
6 1
(Signal 6) ^ 4 2 (Signal 6) ^ 4 2 6 Violet (H)
^ 4 2 6 Sensor
3 3 (Signal 6) controlle
3

Orange 1 1
Orange
(Signal 7) & 4 2 7 4 2 7 1
(Signal 7) &
(I)
Orange Proximit
3 3 (Signal 7) & 4 2 7 sensor
3

Yellow 1 1
Yellow 1 (J)
(Signal 8) * 4 2 8 4 2 8
(Signal 8) * Yellow
* 4 2 8
Photo
3 3 (Signal 8) electri c
3 sensor

(K)
Pressur
sensor
▣Mounting dimensions
4-ø4.5
(L)
Rotary
encoder

(M)
5-Phase
stepping
motor &
Driver &
Controlle

56.5

※4 / 6/ 8 holes size are the same.

I-48
PT Series
▣Connections
lPRCM Series(Connector type) lPRW Series(Cable outgoing type)
Connection cable should be used for connector Cable outgoing type can be connected directly but
type proximity sensor. when the installation distance is longer, please use
connection cable.
Connection cable
: C1D4-2

PRCM18-5DN

PT4-3DN PT4-3DN

▣Applicable models
Distribution box Applicable models Connection

PRCMT12-2DO/DC, PRCMT12-4DO/DC, PRCMT18-5DO/DC,


lConnection cable
PRCMT18-8DO/DC, PRCMT30-10DO/DC, PRCMT30-15DO/DC
PT□-2D DC 2-wire type
PRWT12-2DO/DC, PRWT12-4DO/DC, PRWT18-5DO/DC, lDirect connection
PRWT18-8DO/DC, PRWT30-10DO/DC, PRWT30-15DO/DC lConnection cable

PRCM12-2DN/DN2, PRCM12-4DN/DN2, PRCM18-5DN/DN2,


PRCM18-8DN/DN2, PRCM30-10DN/DN2, PRCM30-15DN/DN2,
lConnection cable
PRCML18-5DN/DN2, PRCML18-8DN/DN2, PRCML30-10DN/DN2,
DC 3-wire type PRCML30-15DN/DN2
PT□-3DN
(NPN type)
PRW12-2DN/DN2, PRW12-4DN/DN2, PRW18-5DN/DN2,
PRW18-8DN/DN2, PRW30-10DN/DN2, PRW30-15DN/DN2, lDirect connection
PRWL18-5DN/DN2, PRWL18-8DN/DN2, PRWL30-10DN/DN2, lConnection cable
PRWL30-15DN/DN2

PRCM12-2DP/DP2, PRCM12-4DP/DP2, PRCM18-5DP/DP2,


PRCM18-8DP/DP2, PRCM30-10DP/DP2, PRCM30-15DP/DP2,
lConnection cable
PRCML18-5DP/DP2, PRCML18-8DP/DP2, PRCML30-10DP/DP2,
PRCML30-15DP/DP2
DC 3-wire type
PT□-3DP
(PNP type) PRW12-2DP/DP2, PRW12-4DP/DP2, PRW18-5DP/DP2,
PRW18-8DP/DP2, PRW30-10DP/DP2, PRW30-15DP/DP2, Direct connection
PRWL18-5DP/DP2, PRWL18-8DP/DP2, PRWL30-10DP/DP2, lConnection cable
PRWL30-15DP/DP2

※It is able to use lead type proximity sensor with connection box, if use plug type connector cable.

▣Proper usage
1. Connection box is only for DC power, Do not use with AC power.
2. Please do not mix DC 2-wire and DC 3-wire types.
Remember, there are NPN /PNP type in DC 3-wire type.
3. Please be sure of correct wiring. Power cable(Blue : -, Brown : +).
4. Green LED will not turn on when the power polarity is reversed.
5. Please connect signal line following the diagram and load must be installed when operating sensor.
6. Please check Red LED when operating sensor.
7. Please use protection cover or water-resistive cover (P96-M12-1) on unused connectors.

※Water resistive cover(P96-M12-1) is optional.