This article provides information on iDrac6 communication failure message occurs at POST on a Dell PowerEdge 11G servers.

Issue:
When you reboot a PowerEdge 11th Generation server you may see the following error during POST.

Alert! iDRAC6 not responding.. Power required may exceed PSU wattage.
Alert! Continuing system boot accepts risk that system may power without warning.
Strike the F1 key to continue, F2 to run the system setup program.

https://www.dell.com/support/article/in/en/indhs1/sln266092/alert-idrac6-not-responding-power-required-may-exceed-psu-wattage-on-a-dell-poweredge-11g-server?lang=en 1/4
7/27/2019 Alert! iDRAC6 not responding.. Power required may exceed PSU wattage. on a Dell PowerEdge 11G Server | Dell India

Solution:
Attempt to reboot the server and the error may clear.

If the error is still present, remove AC power for 30 seconds.


Once AC power is re-applied, Allow 2 minutes for the idrac to complete POST/Initialize, before powering the server back on.

Troubleshooting questions
1. 1.Is iDRAC accessible via local racadm from within the Server OS? (Run "racadm getsysinfo" and see if the idrac returns a response).
2. Is the iDRAC web GUI accessible from a client web browser?
3. Is the iDRAC IP address pingable?
4. Does the error occur on every reboot or is problem intermittent?
5. Once power was drained, did the error immediately come back at the next POST?
6. Has any hardware been replaced?
7. Is the iDRAC still in the hung state after AC cycle?Is this an iDRAC Express or Enterprise? If Enterprise, is the NIC configured for Shared or
Dedicated?
8. Can you connect to iDRAC via SSH/Telnet connection?
9. If Dell OpenManage Server Administrator (OMSA) is installed, is the iDRAC present?
10. Can the issue be reproduced?
11. Is iDRAC LAN disabled in CTRL+E Configuration Utility?

https://www.dell.com/support/article/in/en/indhs1/sln266092/alert-idrac6-not-responding-power-required-may-exceed-psu-wattage-on-a-dell-poweredge-11g-server?lang=en 2/4
7/27/2019 Alert! iDRAC6 not responding.. Power required may exceed PSU wattage. on a Dell PowerEdge 11G Server | Dell India

Steps to Resolve

Through testing in multiple environments, the following steps have been discovered to resolve this issue a majority of the time.
1. Clear flea power (unplug power and hold power button for 20 seconds).
2. Boot to F2 BIOS Configuration Utility and soft reset it (turn on Caps Lock, Scroll Lock, and NUM Lock. Press Alt+e, Alt+f, Alt+b and the system will
reboot).
3. Boot into the Ctrl+E iDRAC BIOS and reset it to Default, escape and the system will reboot.
4. Boot back into the iDRAC BIOS again and verify that the iDRAC LAN and IPMI over LAN are both enabled, save and exit, escape and the system will
reboot.
5. Boot the system to the OS and attempt iDRAC firmware flash to the latest version available.

If the issue remains, it means that the iDRAC is not working and needs to be replace. Also the issue can come from the motherboard as the iDRAC is
plugged on it.

 Note: In systems with software RAID controllers (S100 and S200), the BIOS soft reset will also revert the on-board SATA controller to default.
In order to return control of the drives to the SATA controller, boot to system setup and set the SATA controller mode to RAID.

Need more help?


Find additional PowerEdge and PowerVault (//www.dell.com/EnterpriseKB) articles
Watch Part Replacement Videos (//qrl.dell.com/Product/Categories) for Enterprise products

Visit and ask for support in our Communities (https://www.dell.com/community/)

Create an online support Request (//www.dell.com/support/incidents-online/case)

https://www.dell.com/support/article/in/en/indhs1/sln266092/alert-idrac6-not-responding-power-required-may-exceed-psu-wattage-on-a-dell-poweredge-11g-server?lang=en 3/4
7/27/2019 Alert! iDRAC6 not responding.. Power required may exceed PSU wattage. on a Dell PowerEdge 11G Server | Dell India

Article ID: SLN266092

Last Date Modified: 07/29/2016 02:49 AM

https://www.dell.com/support/article/in/en/indhs1/sln266092/alert-idrac6-not-responding-power-required-may-exceed-psu-wattage-on-a-dell-poweredge-11g-server?lang=en 4/4

S-ar putea să vă placă și