Sunteți pe pagina 1din 12

Surtronic R-series ®

High speed roundness measurement systems


Surtronic® R-series
High speed roundness systems for bearings, automotive and precision industries

Surtronic® R-series
A range of roundness products robust enough for the shop
floor but accurate enough for any inspection room.

Working closely with manufacturers across a wide range of


industries including precision bearings, automotive and
aerospace engineering Taylor Hobson have focussed on the key
attributes that are most important for quality control in today’s
precision industries

The new Surtronic R-series of instruments offer a flexible


solution for all your roundness and form requirements with a
variety of systems and application specific accessories along
with fixtures that can be tailored to your specific need.

Speed (3 parts/minute including set-up)


The most important benefit these systems offer is speed. In precision
industries as manufacturing volumes increase all too often the
bottleneck is metrology. High measurement throughput systems ensure
higher sampling rates are achieved while also supporting increased
manufacturing volumes.

Precision (±25 nm spindle accuracy)


Although many times faster than traditional benchtop roundness
systems there is no loss of precision or accuracy. Full ISO compliant
measurements can be taken with ±25 nm accuracy and 6 nm gauge
resolution (30 nm for R100/R105).

Robustness (suitable for 24/7 operation)


All systems are designed for constant 24 hour, 7 days a week use in
demanding shop floor environments; manufactured using only the X-sight touch screen software
most durable and hard wearing materials.

Ease of use (touchscreen software)

‘‘
The X-sight touch screen software platform with intuitive navigation
make the Surtronic roundness system as easy to use as a SatNav or
SmartPhone with everything you need at your fingertips. Speed and reliability matter;
we choose Taylor Hobson

’’
metrology.
Dr Sashi Balakrishnan, Chief Tribologist,
Mercedes-Benz HPE (leading Formula 1 engine supplier)
World’s highest throughput roundness system…
• Increase manufacturing output • Ensure part traceability
• Reduce part scrappage • Improve ‘right first time’

What can it measure?


The Surtronic R-series of instruments is ideally suited
to measuring high volume production parts across a
wide variety of industries.

Bearings
– Races, Balls, Needles and Rollers

Automotive
– Valves, Con Rods, Pins and Brake Discs

Process Control
– Grinding, Turning, Milling and Honing

Patented gauge orientation


Using Taylor Hobson’s patented gauge orientation with its robust locking mechanism
orientation from roundness to flatness or internal to external only takes a few
second.

Accurate gauging
All systems incorporate Taylor Hobson’s accurate and reliable Talymin gauge
technology, delivering 6nm resolution (30nm for R100 series).

Patented rapid centreTM


Rapid Centre avoids valuable cycle time being lost on manual part centring. On
most parts precision results are achieved following a very simple and fast loading
procedure. Now roundness measurements can be made in less than 30 seconds
including part loading, centring, measurement, analysis and results display!

Accessories and standards


A full range of accessories and standards are available to support the
instrument. These include magnetic chuck, Rapid Centre fixture, Glass
hemisphere, Calibration set, Precision test cylinder, Cresting standard,
Stylus kit, Flick standard (20µm or 300µm) and replacement air filter
modules.
Surtronic® R-series
More than a measurement instrument…
…a new measurement concept

Easy to use software

• D
 eveloped in collaboration with key
bearings, automotive and precision
engineering companies

• L arge colour display, easy viewing


of results

• T
 ouch screen operation means every
feature at your fingertips

• E asy analysis setup with single button


recall

• A
 dvanced analysis packages for
bearings and automotive applications

Taylor Hobson’s tried and tested Precision


diamond turned air bearing spindle with
±25nm accuracy. Now includes auto
aligning sleeve for ease of maintenance.

‘‘ Our 15 Taylor Hobson roundness


machines ensure we maintain our

’’
high throughput and accuracies.
Derek Pitcher, Q/A Coordinator, Barden
Corporation, UK, a member of the Schaeffler Group
Testimonials

Mercedes-Benz High Performance Engines


Mercedes-Benz Technology Centre design, manufacture and test
Formula 1 racing engines for Mercedes GP Petronas, Vodafone
McLaren Mercedes and Force India F1 racing teams.

The company is renowned for its high quality parts and technical
excellence, and also its speed and flexibility, which has helped to
bring success for Formula 1 racing drivers.

Successes
• 2010 Dewar Trophy for Technical Excellence for KERS
• 2010 Race Engine Technology magazine, ‘Race Engine of the Year’
• 2009 Formula 1 Constructors’ World Championship, (Brawn GP)
• 2009 Formula 1 Drivers’ World Championship (Jenson Button)

‘‘
Speed and reliability are important both on and off the track for us, we have to work to the tightest
of timescales and highest tolerances to get our engines race ready. Taylor Hobson equipment gives
us high throughput and the confidence in our manufacturing processes to allow us to continually

’’
control and improve them.
Dr Sashi Balakrisnan, Chief Tribologist, Mercedes Benz High Performance Engines
(leading Formula1 engine supplier)

Barden
A world leader in the design and manufacture of super precision ball bearings,
Barden bearings are produced to the highest standards available.

Used in industries with a neccessity for critical tolerances, high speeds and reliable
performance under demanding operating conditions, Barden bearings are also
used in safety-critical and harsh environment applications.

Applications
• Aerospace • Nuclear bearings
• Industrial plants • Automotive industries
• Dental and medical

‘‘ Having the responsibility to ensure 1.5 million bearings each year are to the highest quality,
controlling our components at all stages of manufacturing. We have 15 Taylor Hobson roundness
measuring instruments that help us maintain high throughput and the accuracies we require to

’’
ensure every single bearing is the highest quality.
Derek Pitcher – Q/A Co-Ordinator – Measurement
The Barden Corporation (UK) Ltd, a member of the Schaeffler Group
Applications
Bearing components

Bearing races Ball bearings Needles and rollers

Automotive components

Valves Con rods Brake discs

Monitoring manufacturing

Grinding Turning Milling Honing

Join the roundness revolution


Whatever your industry or application if you need high speed roundness measurement we have it covered…

Roundness Eccentricity Squareness Harmonic analysis

Flatness Concentricity Parallism Thickness variation

Coaxiality Radial runout


Surtronic R-series specifications
High speed roundness systems for bearings, automotive and precision industries

R-100 series R-120 series


Model
number
R-100 R-105 R-120 R-125

Max diameter 300 mm 300 mm

Measuring
Max height 300 mm 300 mm
capacity

Max weight 20Kg (44 lb) 20Kg (44 lb)

Diameter, standard 125 mm 125 mm


Diameter, accessory 300 mm 300 mm

Work table Centering ±1.25 mm ±1.25 mm

Levelling 30 arc minutes 30 arc minutes

Height of neutral plan 51 mm 51 mm

Speed of rotation 20 Rpm Max 20 Rpm Max


Spindle
Accuracy ± 25 nm @ 6RPM ± 25 nm @ 6RPM

Range 2 mm 2 mm
Gauge
Resolution 30 nm 6 nm

Type None, Gaussian, Robust


None, Gaussian, Robust
Standard filter cut-offs 1–15 upr, 1–50 upr, 1–150 upr, 15–150 upr,
Filter 1–15 upr, 1–50 upr, 1–150 upr, 1–500 upr
1–500 upr, 15–500 upr
User selectable
Special filters User selectable & Bandpass

Roundness/flatness ü ü ü ü
Coaxiality, eccentricity, ü ü ü ü
Concentricity, radial runout ü ü ü ü
Squareness l ü ü ü
Parallism l ü ü ü
System
features
Measure interrupted surfaces l ü ü ü
Harmonic analysis l l ü ü
Thickness variation l l l ü
Advanced harmonics û û l ü
Centering attachment 125mm l l l ü
Table top 300mm l l l l

All accuracies and uncertainties are quoted at 20°C ± 1°C (68°F ± 1.8°F with 1-50 filter at 6 rpm.
Due to continuing technical improvements, Taylor Hobson reserves the right to change these specifications.

ü= Included – l = Optional û = Not available


(Customer specific analysis available on request)
Floor plans
750 mm Arm extended
620 mm Nominal height excluding feet

620 mm
320 mm

3 M5 x 8 mm deep tapped holes


Equi-spaced on the following PCDs
Ø 25.3mm (± 0.05 mm)
500 mm Ø 58.7mm (± 0.15 mm)
Ø 92.5mm (± 0.4 mm)

750 mm Arm extended


320 mm

90°

6.5 mm

500 mm

Environmental / services
Model number R-100 R-105 R-120 R-125
Weight (without fixtures) 35 Kg 40 Kg

Alternating supply, single phase with earth (3 wire system)


Voltage: 90 - 260 v
Electrical supply
Frequency: 47 - 63 Hz
Consumption (total system): 250 VA max, 160 W

Temperature: Operating 10 - 35°C (50°F - 95°F)


Temp / time gradient less than 2°C / hour (3.6°F / hour)
Environmental conditions Humidity operating 30 % to 80 % relative, non-condensing
Storage 10 % to 90 % relative, non-condensing
Free air flow rate 1.0 m / sec maximum steady (39.4 in / sec)

Maximum source pressure 8.1 bar (120 psi)


Minimum source pressure 5.4 bar (80 psi)
Air consumption 0.037 cu.m / min (1.3 scfm)
Air source requirements
Operating pressure 4.1 bar (60 psi)
Filtering 5 µm (200 µin)
Moisture content – dewpoint 2 °C (3.6 °F)
RONt

Analysis Roundness Thickness ∆r1


Datum
Thicknessvariation ∆r1 R axis
Thickness
variation Wall Squareness
∆r1
∆r2
Thickness
variation
Thickness
Wall ∆r1∆r1 ∆r2

ccentricity (E) variation


variation
Wall ∆r2 - ∆r1∆r2
Sqr
FLTt ∆r2 - ∆r1
ricity (E) Wall
Wall ∆r2∆r2
Datum ∆r2 - ∆r1
ity (E) axis

R-100
R-105
R-120
R-125

R-100
R-105
R-120
R-125
Type of Measurement Evaluation Type of Measurement ∆r2∆r2 Evaluation
- ∆r1
- ∆r1
icity (E)(E) analysis Flatnessmode
ntricity ECC
diagram analysis mode diagram
ECC RONt
RONt
RONt
RONt ∆z2
ECC ∆z2
ECC
ECC
CONC Thickness ∆z2 ∆z1
Roundness Runout Thickness Parallelism ∆z2∆z2 ∆z1
Roundness
Roundness Runout RONt
Datum variation Datum
Roundness Datum axis variation
Datum
Datum ∆z2 -z1
∆z1 z2
R R ∆z2 Datum
axis

Squareness
disc axis
Roundness

Runout axis RONt


RONt
RONt Thickness R R axis
∆z1
- ∆z1
axis
Concentricity (C)
Runout disc
Thickness
Thickness
Squareness ∆z1∆z1
Runout
Runout Datum ü ü ü ü variation
Squareness
Squareness z2 - z1
∆z2 - ∆z1 – ü ü ü
nout
Radial Datum
axisDatum Squareness
variation
variation
oundness
dial axis
axis disc ∆z2∆z2
- ∆z1
- ∆z1
ut FLTt
disc
disc Datum Sqr
Sqr
Roundness FLTt
FLTt R axis Sqr
out
unout Roundness
oundness FLTt Sqr
Datum
Datum
Datum
Datum Datum
ial
adial Datum
axisDatum
axis Squareness R RR
axis
axis
axis
axis
Flatness
Flatness
Flatness axis Squareness
Flatness Runout
Squareness
Squareness
FLTt Runout Sqr
RONt Harmonics
DatumRONt RONt
FLTt Harmonics Sqr
FLTt FLTt
axis RONt Sqr ∆r1 Sqr
Thickness

Parallelism
Runout
CONC RONt
Datum
Flatness CONC
Flatness

Runout
CONC Datum Datum
Runout axis RONt Harmonics
Parallelism
Runout CONC
axis axis Parallelism
Harmonics
Harmonicsvariation
Parallelism
Runout Flatness RONt ü ü ü ü Parallelism z1z1
z1 z2z2 – ü ü ü
Flatness
Roundness Flatness
Roundness
Arial RONt
RONt Wall z1 z2
Datumz2 ∆r2
city (C)Roundness
Arial RONt RONt RONt Datum
R axis
Datum
ty (C)
ty (C)
oundness
Roundness Rz1 axis
tricity
unout
Runout (C)
Runout CONC z2z2
z2
- z1 Datum
-- z1 R
Datum axis∆r2 - ∆r1
Roundness Eccentricity (E) Squareness
Parallelism Rz2R
- z1 axis
axis Datum
Arial
Arial Squareness
Squareness
oundness Arial CONC CONC
CONC z1 R z2
axis
oundness
Roundness Squareness
Squareness Parallelism
Parallelism Datum
ndness Parallelism Datum
Datum
(C) Roundness
R Datum z1
axis z2
Sqr
tyRoundness FLTt
FLTt ECC Squareness OR
z1R z1axis
DatumDatum
z2Sqr z2
FLTt OR R - z1RR axisaxis
z2 Raxis Sqr
axis Sqr
ncentricity (C) FLTt Datum
Datum axis Squareness Interrupted Surface Sqr
centricity
y (C) (C) FLTt Datum Squareness
Squareness ∆z2
axis Coax
Coax Squareness
Interupted
Squareness z2 - z1 Sqr
Flatness
FlatnessFlatness
FLTtDatum
Datum axis InteruptedSquareness z2 - z1 z2 - z1
Coaxality

Measure

FLTt
axis
axis Datum surface OROR
OR Sqr
Flatness surface Thickness Sqr – ü
Sqr Sqr
Flatness FLTt axisü ü ü ü ü ∆z1
ü
Coaxality
Coaxality FLTt FLTt
FLTt FLTtDatum Runout Sqr Sqr
Flatness Coax
Coax
Coax
Datum
Datum
axis Thickness
Thickness
Interupted
Datum
Interupted
Interupted
Thickness variation ∆r1
∆r1
∆r1
Datum Datum
axis Datum Thickness
axis
∆r1 ∆z2 - ∆z1
Flatness axis axis
CONC
axis axis
variation
variation
surface
surface
surface
variation disc
Flatness
Flatness Flatness CONC CONC variation Parallelism
Coaxality
Coaxality FlatnessRunout
Flatness
Coaxality CONC
WallParallelism
Wall
Wall Parallelism z1 ∆r2 ∆r2 ∆r2
z2
CONC Wall
Parallelism z1 ∆r2
z2
Radial z1 z2
entricity (C)
CONC Thickness Parallelism Parallelism
∆r1
z1∆r2∆r2 -
z1 - ∆r1
∆r2 - ∆r1
∆r1 z2z2
ccentricity
ty (C)
entricity
entricity
centricity (E)
(E)
(E)
(C) CONC harmonicharmonic ∆r2
z2 z1∆r1
- z1
variation
Thickness ∆r1 z2
yEccentricity
Squareness(E) Parallelism z2 - z1
uareness
(C) CONC
CONCCONC Thickness
Thickness analysis ∆r1 z2 -∆r1
z1
ity (C)
Harmonic Analysis

CONC CONC Wall analysis


Parallelism
Parallelism
variation z1
z2z2
- z1 ∆r2 z2
centricity (C) Parallelism
variation
variation Parallelism
Parallelism - z1
z1z1 z2 - z1 z2z2
Concentricity

ECC
ECC Wall z1 z1 z1 z2 z2 ∆r2 ∆r2z2
y (C) ECC ECC Wall harmonic
harmonic
Wall
harmonic ∆r2 - ∆r1 ∆r2
areness
quareness
yity(C)(C) (E)
eness
entricity ü Runout
z2 - z1
C) entricity
city (C) (C) ü ü ü analysis
analysis
analysis Harmonics z2z2
- z1 ∆z2
∆z2
- z1 ∆z2 ∆r2 - ∆r1 – – ü ü
z2 - z1 z2 ∆z2- ∆r1
z2 -∆r2
z1
entricity Eccentricity
Eccentricity
(E) (E)
(E)
∆r2- z1
- ∆r1

RunoutECC
Thickness
Thickness
Thickness ∆z1
∆z1
∆z1
∆r2 Runout Runout
RunoutRunout Datum Datum
Thickness
variation
∆z1
Axis 2 Axis Datum
N ECC N variation
variation ∆z2 ∆r1 ∆z2
Arial ECC2 axis ECC
Datum
axis Thickness discvariation ∆z2
∆z2
-
- ∆z1
- ∆z1
∆z1
-axis -
axis ThicknessThicknessdisc
disc
∆r1
∆r1 ∆z2 ∆z2 - ∆z1
Runout 1 1 Thickness variation disc ∆r1
∆r1 ∆z2 ∆z2
Runout
Runout L L variation
N Thickness variation
2 Runout N WallThickness
Thickness ∆r1 ∆z1 ∆r2
Radial
Radial Runout N N variation
Wall
- variation Wall
∆r2
Radial
2-∆r1Radial
∆r2-∆r1 Axis1 2 Axis
AxisAxis
Axis 2 2 1 Datum N- - variationThickness ∆r2 ∆z1
- Thickness
Wallvariation
ThicknessThickness ∆r1 ∆r2
Eccentricity

Runout ∆z1 ∆z1


Runout Runout axis- 1 1 Wall
Thickness
Thickness disc ∆r1∆r1
∆z2
∆r2
∆r2 - ∆r1 - ∆z1
Eccentricity (E) L L 1 1 Datum Thickness
variation Wall
Thickness variation ∆r1∆r2∆r1- ∆r1 ∆r1
Radial

entricity (E) L 1 NDatum


Datum N Thickness variationvariation ∆r2 - ∆r1 OR ∆r2 ∆z2 - ∆z1
Runout Eccentricity (E) axis üvariation
variation
ü variationüWallvariation
ü ∆z2 - ∆z1 ∆z2 – - ∆z1– – ü
entricity (E) axis Naxis
variation disc disc
disc
∆r2∆r2- ∆r1
- ∆r1 ∆r2
centricity
-∆r1
∆r2-∆r1 (E) Axis 1 1
Axis - - Wall
Radial
r1 Runout Axis 1 - WallWall
Coax ∆r2∆r2∆r2
- ∆r1
RunoutEccentricity
Runout (E) Wall Wall Interupted ∆r2 ∆r2 ∆r2
Thickness Variation

Radial ECC 11 1
Runout
Runout ∆r2 - ∆r1
ECC Runout
ntricityRadial
Radial (E) ECC
Runout Harmonics
Harmonics
Harmonics surface ∆r2∆r2- ∆r1
- ∆r1
ntricity
centricity
ricity (E)
(E) (E) ECC
ECC Harmonics ∆r2 - ∆r1
∆r2 -∆z2
∆r1 ∆z2
∆r2 - ∆r1
Eccentricity
centricity (E) (E) Coaxality ECC ∆z2
∆z2
∆z2
Runout ECC Thickness ∆z2 ∆z1
Runout
Runout ECCRunout
ECC Thickness ∆z1
Runout ECCRunout
Runout ECC ECC Datum Thickness
Harmonicsvariation ∆z1
Arial
Arial
Arial Runout Runout
Datum Runout Thickness
variation ∆z2 ∆z1
Arial Runout Runout axis
Datum Thickness
variation ∆z2
∆z2 ∆z1 ∆z2 - ∆z1
Runout axis
Datum
Harmonics
variation
Harmonics disc
Thickness
Harmonics ∆z2 ∆z2 ∆z2
∆z2 - ∆z1 ∆z1- ∆z1
∆z2
Runout Datum axis disc
variation
disc ∆z2 - ∆z1
Runout axis variation harmonic
Axial

Axial

∆z2
∆z1 - ∆z1
Runout Runout Squareness
Runout Runout
axis Datumü ü ü ü Thickness
disc
disc – - ∆z1– – ü
axis Thickness
Thickness ∆z1∆z1 ∆z2
Runout
Radial Radial Runout
Runout Datum Thickness
variationdisc
Thickness
Thickness analysis ∆z1 ∆z1 ∆z1
RunoutArial
Radial
Runout Runout Runout
Runout Datum
Datum variation
variation ∆z2 - ∆z1
Runout
Radial Runout
Runout axis variation
Radial Datum DatumDatum
axis disc variation
variation OROR ∆z2 - ∆z1
∆z2 - ∆z1
Arial axis axis disc
disc OR ∆z2 - ∆z1 ∆z2 - ∆z1
Radial Runout

∆z2 - ∆z1
Arial Arial
unout Radial axis axis disc disc disc
OR
unout
Runout
nout Coax
Coax
adial Runout
Runout CoaxCoax Interupted
Interupted
Interupted
adial
Radial
ial Interupted
RadialRadial Runout surface
surface
surface
Runout Runout surface Harmonics OR
Coaxality
Coaxality
Coaxality Harmonics
Coaxality∆r2 Runout
Runout NHarmonics
Harmonics OR
Axis 2 OR OR
- Harmonics
CoaxRunout Interupted Harmonics
Radial

Runout Coax
RunoutRunout
Runout
∆r1
Coax üCoax
Runout
Runout
Runout
Lü surface
ü1 Harmonics
üInteruptedInterupted
Interupted
N
Runout
Arial Arial Harmonics
Coaxality
Runout Runout Harmonics
surface
Runout Arial∆r2-∆r1 Axis 1 Harmonics
surface surface Harmonics
Harmonics
-
Arial
Arial
Coaxality Coaxality
Runout
Coaxality harmonic
harmonic
1 harmonic
Squareness
Squareness
Squareness harmonic
Runout Arial
Squareness analysis
analysis
analysis
Runout
Runout
Runout analysis
Arial Runout
Runout
Arial
ArialArial
Arial Arial harmonic OR
OR
Squareness OR
Coax analysis harmonic OR
OR
Squareness Coax harmonic
Interupted harmonic OR
Squareness
Squareness Coax Interupted
Interupted analysis
Coax
Coax analysis
surface
Interupted analysis
∆r2
∆r2 Coax
surface
Interupted
surface OR
OR
∆r2 Coaxality
∆r2Coaxality Axis
Axis
Axis 22 2 2
NN
N surfaceInterupted
surface OR OR
OR OR
Coaxality Axis Coax -- - N
Coaxality
Coaxality Coax1 1 -
Coax surface
Interupted
L L Coax Coax1 Coax Interupted
Interupted
Surtronic product range

Surtronic® Duo measures surface roughness at the touch of a button


and shows the result on a large LCD window. Cycle time is about 5
seconds and the result is saved until another measurement is taken.
• Ready to use out of the box
• 
Battery life more than 5000 measurements

Parameters Range Resolution

Ra: 40µm (1600µin) 0.01µm (0.4µin)

Rz, Rv, Rp, Rt: 199µm (7800µin) 0.1um (4µin)

Surtronic® 25 offers high speed roughness with a large display


and simple menu structure. Battery powered and offering total
portability with a built-in memory for up to 100 readings.
• Unique stylus lift for total flexibility
• Long traverse length & extended pick-up reach
• Powerful PC software included
Inductive pick up

Gauge range / resolution 300µm (0.012in) / 0.01µm (0.4µin)

Accuracy (5 µm diamond tip) 2% of reading + LSD µm

The Surtronic® R-100 Series is robust enough for the shop floor,
giving a flexible solution for all roundness and form requirements that
can be tailored to your needs with analysis options and fixtures.
• Patented gauge orientation
• Robust enough for 24/7 operation
• Easy-to-use touchscreen software

Feature

Gauge resolution 30 nm (1180 µin)

Spindle accuracy 25 ±nm (980 µin)

Surtronic® R-120 Series builds on the robustness and ease-of-use of the


R-100 Series, offering a higher throughput and improved resolution. It also
includes all advanced roundness analyses and harmonics.
• Robust, fast and easy-to-use
• Includes Rapid CentreTM
• Throughput 3 parts / minute including set-up

Feature

Gauge resolution 6 nm (236 µin)

Spindle accuracy ±25 nm (980 µin)


Accessories

1 Six jaw component chuck 6 Cresting standard – 1 2


A 6-jaw precision scroll chuck. For checking the vertical and
Capacity – Inside diameter horizontal alignment of the
20 mm – 95 mm (0.78 in–3.74 in) gauge head.
Capacity – Outside diameter code 112/1876 optional
2 mm–32 mm (0.08 in –1.26 in).
code 112/1859 optional. Reservoir assembly kit –
If the air supply is of poor quality or
unreliable and does not meet the
2 Standard stylus arms
instrument’s standards, then the
Ruby ball x 100 mm (3.9 in)
reservoir assembly is recommended 3
1 mm (0.039 in), code 112/3245
to provide an even flow of air to the
2 mm (0.078 in), code 112/3244
spindle.
4 mm (0.157 in), code 112/3243
code 112/2869 optional

Bar stylus 7 Flick standard –


A 100 mm (3.9 in) stylus for measuring For rapid calibration of gauge
small diameter components head sensitivity; alternative to
code 112/3489 optional the gauge calibration set.

'Let's talk Roundness' book 20 µm (788 µ") range


A 64-page handbook on the code 112/2308 optional
theory and practice of roundness
4
measurement. 300 µm (.012") range
code 600-5 standard code 112/2233 optional

3 Glass hemisphere – Pre-filter element


For checking overall system code 112/2361 optional
performance. UKAS calibration
certificate is optional. Accessory case – A useful
case for carrying standard
Roundness < 0.05µm (2µ") and optional accessories.
code 112/436 optional code 48/453 optional

4 Calibration set – 8 Six jaw component chuck


For calibrating the gauge head. A 6 jaw precision scroll chuck.
Comprises a circular glass flat Capacity: inside diamter 5
and three gauge blocks (2.5 mm, 20 mm - 95 mm (0.78 in - 3.74 in).
2.8 mm and 3 mm). UKAS calibration Capacity: outside diamter
certificate is optional. 2 mm - 32 mm (0.08 in - 1.26 in)
code 112/1874 optional code 112/1859 optional

5 Precision collet chuck – Kinematic dowel support set –


removable For stable workpiece mounting.
Three ball type location (for use with code 112/1861 optional
manual or automated tables)
Note: collet required – see list below. Special requests 6 7
code 112/3662 Taylor Hobson can also provide
customized products which are
112/3554-1.0 1 mm collet designed to exactly match your
112/3554-1.5 1.5 mm collet requirements. These include work
112/3554-2.0 2 mm collet components with specific dimensions
112/3554-2.5 2.5 mm collet and special styli for applications such
112/3554-3.0 3 mm collet as small holding devices for bores,
112/3554-3.5 3.5 mm collet shoulders or undercuts.
112/3554-4.0 4 mm collet
112/3554-4.5 4.5 mm collet 8
112/3554-5.0 5 mm collet
112/3554-5.5 5.5 mm collet
112/3554-6.0 6 mm collet
112/3554-6.5 6.5 mm collet
112/3554-7.0 7 mm collet
112/3554-7.5 7.5 mm collet
112/3554-8.0 8 mm collet
Serving a global market Taylor Hobson UK
(Global Headquarters) © DiskArt™ 1988

PO Box 36, 2 New Star Road


Taylor Hobson is world renowned as a manufacturer Leicester, LE4 9JQ, England
of precision measuring instruments used for inspection Tel: +44 116 276 3771 Fax: +44 116 246 0579
in research and production facilities. Our equipment email: taylor-hobson.uk@ametek.com
performs at nanometric levels of resolution and accuracy.

To complement our precision manufacturing capability we


also offer a host of metrology support services to provide
Taylor Hobson France
Rond Point de l’Epine Champs
our customers with complete solutions to their measuring Batiment D, 78990 Elancourt, France
needs and total confidence in their results. Tel: +33 130 68 89 30 Fax: +33 130 68 89 39
taylor-hobson.france@ametek.com
Contracted Services from Taylor Hobson

• Inspection services
Taylor Hobson Germany
Postfach 4827, Kreuzberger Ring 6
measurement of your production parts by 65205 Wiesbaden, Germany
skilled technicians using industry leading Tel: +49 611 973040 Fax: +49 611 97304600
instruments in accord with ISO standards taylor-hobson.germany@ametek.com

• Metrology training
practical, hands-on training courses for
Taylor Hobson India
1st Floor, Prestige Featherlite Tech Park
roundness and surface finish conducted 148, EPIP II Phase, Whitefield, Bangalore – 560 006
by experienced metrologists Tel: +91 80 6782 3200 Fax: +91 80 6782 3232
taylor-hobson.india@ametek.com
• Operator training
on-site instruction will lead to greater
proficiency and higher productivity
Taylor Hobson Italy
Via De Barzi
20087 Robecco sul Naviglio, Milan, Italy
• UKAS Calibration and Testing Tel: +39 02 946 93401 Fax: +39 02 946 93450
certification for artifacts or instruments taylor-hobson.italy@ametek.com
in our laboratory or at customer’s site

For the above services, contact our Center of Excellence: Taylor Hobson Japan
3F Shiba NBF Tower, 1-1-30, Shiba Daimon Minato-ku
email: taylor-hobson.cofe@ametek.com
Tokyo 105-0012, Japan
or call: +44 116 276 3779 Tel: +81 (0) 3 6809-2406 Fax: +81 (0) 3 6809-2410
taylor-hobson.japan@ametek.com
• Design engineering
special purpose, dedicated metrology Taylor Hobson Korea
systems for demanding applications #310, Gyeonggi R&DB Center, 906-5, lui-dong
Yeongtong-gu, Suwon, Gyeonggi, 443-766, Korea
• Precision manufacturing Tel: +82 31 888 5255 Fax: +82 31 888 5256
taylor-hobson.korea@ametek.com
contract machining services for high
precision applications and industries

• Preventative maintenance
Taylor Hobson China Beijing Office
Western Section, 2nd Floor, Jing Dong Famg Building (B10)
protect your metrology investment No.10, Jiu Xian Qiao Road, Chaoyang District, Beijing, 100015, China
with a Talycare service cover plan Tel: +86 10 8526 2111 Fax: +86 10 8526 2141
taylor-hobson.beijing@ametek.com
For the above services, contact our Sales Department:
email: taylor-hobson.sales@ametek.com
or call: +44 116 246 2034 Taylor Hobson China Shanghai Office
Part A, 1st Floor, No. 460 North Fute Road
Waigaoqiao Free Trade Zone, Shanghai, 200131, China
Tel: +86 21 5868 5111-110 Fax: +86 21 5866 0969-110­
taylor-hobson.shanghai@ametek.com

Taylor Hobson Singapore


AMETEK Singapore, 10 Ang Mo Kio Street 65
No. 05-12 Techpoint, Singapore 569059
Tel: +65 6484 2388 Ext 120 Fax: +65 6484 2388 Ext 120
OPTIMA taylor-hobson.singapore@ametek.com

UKAS
Taylor Hobson USA
1725 Western Drive
West Chicago, Illinois 60185, USA
Tel: +1 630 621 3099 Fax: +1 630 231 1739
2624 TAYLOr HOBSON taylor-hobson.usa@ametek.com
A8248 ISO9001

www.taylor-hobson.com
Copyright© 2011 • Taylor Hobson • Surtronic Roundness_07/2011

S-ar putea să vă placă și