Sunteți pe pagina 1din 1

TD 15-487

12 Core Armoured Direct Buried Double Jacket PE

Cable Design IEC/EN 60794-3-10

x Central strength member (CSM): steel wire.

x Loose Tube: thermoplastic material, containing 6 optical fibres and


filled with a suitable water tightness compound.

x Stranding: the required number of elements (tubes or fillers) are SZ


stranded around the central strength member.

x Longitudinal Water Tightness: polyester tape (jelly filled).

x Inner Sheath: PE. 1 ripcord beneath.

x Armour: corrugated steel tape. 2 ripcords beneath.

x Outer Sheath: HDPE.

- not to scale -

Technical data
No. of Fibres 12
Design (Elements × Fibres per Tube) 6x6
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Inner sheath thickness mm 0.8 nominal
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 13.1 nominal
Cable Weight kg / km 192
Max installation tension N 3000
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.

Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 3000N fibre strain d 0.33%, 'D reversible
Crush(short term) IEC 60794-1-2-E3 3000 N / 100mm 'D d 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 'D d 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm

Optical Characteristics
See the attached cabled optical fibre data sheet.

Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 14 of 28