Documente Academic
Documente Profesional
Documente Cultură
Our Products:
Conventional and PTC semi-conductor control panel heaters and fan-assist-
ed heaters ranging from 5W to 1200W, as well as tropicalised and EX varia-
for high voltage swichtgear in tions. Temperature and humidity controls ranging from 0°C to 60°C (30° to
outdoor and indoor substa- 140°F) and 35% to 100% RH.
tions A new filter fan series in EMC and standard versions with excellent
performance and shielding
characteristics. Panel lighting and accessories.
About us:
We have been developing and producing innovative products for thermal
management for more than twenty years. Our products are renowned for their
reliability and long life, simplicity of use and high quality. Used and proven
system protction in the auto- worldwide even under extreme conditions.
motive industry
2
Contents:
Heating:
Small semiconductor heater RCE 016 Series................................................... 4
Small semiconductor Heater RC 016 Series..................................................... 5
Small semiconductor Heater HGK 047 Series.................................................. 6
Small semiconductor Heater CSK 060 Series.................................................. 7
Finned extruded Heater SAN-FXE.................................................................... 8
Semiconductor Heater HG 140 Series.............................................................. 9
Compact Fan Heater HGL 046 Series............................................................... 10
Hazardous area Heaer CREx 020 Series........................................................... 11
Electrical Direct Heater SAN-LP........................................................................ 12
Electrical Space Heater SAN-LP AF Ex Heater................................................. 13
Electrical Smart Heater SAN-SMLP.................................................................. 14
Semiconductor Heater CS 060 Series.............................................................. 15
Semiconductor Heater CSF 060 Series............................................................ 16
Small semiconductor Fan Heater CS 028 Series.............................................. 17
Compact semiconductor Fan Heater CSL 028 Series...................................... 18
Electrical Smart Heater SAN-GSMLP............................................................... 19
Explosion proof Heater SP................................................................................ 20
Electrical Smart Heater..................................................................................... 21
Electrical Smart-Space Ex Heater SM-*A......................................................... 22
Electrical Direct Ex Heater CS-*S...................................................................... 23
Electrical Direct Ex Heater CT-*A...................................................................... 24
Anti Condensation and Space Heater SAN-HEF.............................................. 25
Space-saving Fan Heater HV 031 / HVL 031 Series......................................... 26
Semiconductor Fan Heater CR 027.................................................................. 27
Fan Heater with integrated thermostat or hygrostat CR 030............................ 28
Fan Heater with integrated thermostat or hygrostat CR 130............................ 29
Fan Heater with/without integrated thermostat CS 030................................... 30
Fan Heater with/without integrated thermostat CS 130................................... 31
Ventilating:
Low maintenance Filter Fan FF 018 Series (21m3/to 102m3/h)......................... 32-33
Low maintenance Filter Fan FF 018 Series (200m3/h)....................................... 34
High-performance Filter Fan FF 018 Series (300m3/h)...................................... 35
High-performance Filter Fan FF 018 Series (550m3/h)...................................... 36
Outdoor Filter Fan FF 018 Series...................................................................... 37
Low noise Roof Filter Fan RFF 018 Series........................................................ 38
High-performance 19” Fan Tray LE 019 Series................................................. 39
Regulating and monitoring:
Electronic Relay SM 010 (DC 24V + DC 48V).................................................... 40
Small, compact Thermostat KTO 011 / KTS 011.............................................. 41
Fix Thermostat FTO 011 / FTS 011................................................................... 42
Dual Thermostat ZR 011................................................................................... 43
Dual Thermostat FTD 011................................................................................. 44
Mechanical Thermostat FZK 011...................................................................... 45
Electronic Thermostat ET 011 (DC 24V)............................................................ 46
Ex FixTherm96 Thermostat............................................................................... 47
FixTherm96 Thermostat.................................................................................... 48
Mechanical Hygrostat MFR 012........................................................................ 49
Electronic Hygrostat EFR 012........................................................................... 50
Electronic Hygrottherm ETF 012....................................................................... 51
Hazardous area Thermostat REx 011 Series.................................................... 52
Lighting:
Slimline Lamp with on/off switch SL 025 Series............................................... 53
Slimline Lamp with movement sensor SL 025 Series....................................... 54
Dual Lamp with on/off switch DL 026 Series.................................................... 55
Dual Lamp with movement sensor DL 026 Series............................................ 56
Hand Lamp with lamp holder DL 026 Series.................................................... 57
Compact Lamp KL 025 Series.......................................................................... 58
Accessories:
Electrical Sockes SD 035 Series .................................................................... 59
Pressure compensation Device DA 084............................................................ 60
Pressure compensation Device DA 284............................................................ 61
Pressure compensation Device DA 284 (stainless steel).................................. 62
Self-adhesive appliance holder SANOFIX......................................................... 63
Indication of measurements in m.m. Errors and omissions excepted. Specifications are subject to change with-
out notice. Suitability of the products for their intended use and any associated risks must be determined by the
end customer/buyer in their final application.
3
5W, 9W
Small semiconductor
Heater - RCE 016 Series
• Temperature limiting
• Wide voltage range
• Dynamic heating up
• Energy saving
• Compact
Technical Data:
Operating voltage 12-240V AC/DC* (min. 110V, max. 265V)
Heating element PTC resistor, temperature limiting
Heater body Aluminum
Mounting See Accessories
Fitting position Variable
Dimensions Length 45mm, Ø10mm
Op./storage temperature -45 to +70ºC
Prot. type / Prot. class IP32 / II (double insulated)
Approvals VDE + UL File No. E150057
Accessories Mounting clips (see illlustration)
Note Other voltages on request
*) Op. with voltages below AC/DC 140V reduces heating performance by approx. 10%.
Example of connection
L
N
Mounting clips Art. No. (1 packing unit = 2 pieces)
Art. No. Voltage Heating capacity* Inrush current max. Surface temp. (approx.) Connection Weight (approx.)
82240 120-240 5W 2.0A 165˚C 2xAWG 22 sheathed cable (silicone) 20g
82241 12-36 5W
82242 120-240 9W 2.5A 175˚C 2xAWG 22 sheathed cable (silicone) 20g
82243 12-36 10W
* At 20ºC (68˚F) ambient temperature.
4
8W, 10W, 13W
Small semiconductor
Heater - RC 016 Series
• Temperature limiting
• Wide voltage range
• Dynamic heating up
• Energy saving
• Compact
Technical Data:
Operating voltage 120-24V AC/DC* -(min. 110V, max. 265V)
Heating element PTC resistor, temperature limiting
Heater body Aluminium, anodised
Mounting Screw fixing
Fitting position Variable
Op./storage temperature -45 to +70ºC (-40 to +158˚F)
Prot. type / Prot. class IP32 / II (double insulated)
Approvals VDE + UL File No. E150057
Note Other voltages on request
Art. No. : Connection 2xAWG 18 stranded wire
*Op. with voltages below 140V AC/DC reduces heating performance by approx.
10%.
Example of connection
L
N
Art. No. Heating capacity* Inrush current max. Surface temp. (approx.) Connection Weight (approx.)
82244 8W 2.0A 150˚C 2xAWG 18 stranded wire 20g
82246 10W 2.5A 155˚C 2xAWG 22 sheathed cable (silicone) 28g
82248 13W 3.0A 170˚C 2xAWG 22 sheathed cable (silicone) 34g
82243 8W 3.7A 134˚C 2xAWG 18 stranded wire 20g
82247 10W 5.7A 132˚C 2xAWG 22 sheathed cable (silicone) 28g
82249 13W 10.0A 148˚C 2xAWG 22 sheathed cable (silicone) 34g
* At 20ºC (68˚F) ambient temperature.
5
10W to 30W
Small semiconductor
Heater - HGK 047 Series
• Dynamic heating up
• Energy saving
• Wide voltage range
• Temperature limiting
• Clip fixing
Technical Data:
Heating element PTC resistor, temperature limiting
Heater body Extruded aluminium profile, anodised
Mounting Clip for 35mm DIN rail, EN 60715
Fitting position Vertical
Op. / Storage temp. -45 to +70ºC
Prot. type / Prot. class IP54 / I (earthed)
Accessories Screw fixing
50 25
Clip for
35mm DIN rail
L
Example of connection
L
N
Art. No. Operating voltage Heating Inrush Length Weight Connection Approval
capacity1) current max. (L) (approx.)
83250 120-240V AC/DC2) 10W 1.0A 50mm 0.1kg 3 x 0.5mm2 x 300mm sheathed cable (silicone) VDE
83251 120-240V AC/DC2) 20W 2.5A 60mm 0.2kg 3 x 0.5mm2 x 300mm sheathed cable (silicone) VDE
83252 120-240V AC/DC2) 30W 3.0A 70mm 0.2kg 3 x 0.5mm2 x 300mm sheathed cable (silicone) VDE
83253 110-120V AC/DC 10W 1.0A 50mm 0.1kg 3 x AWG 20 x 300mm sheathed cable UL File No. E150057
83254 110-120V AC/DC 20W 1.5A 70mm 0.2kg 3 x AWG 20 x 300mm sheathed cable UL File No. E150057
83255 110-120V AC/DC 30W 1.5A 100mm 0.2kg 3 x AWG 20 x 300mm sheathed cable UL File No. E150057
1)
at 20°C ambient temperature; 2) (min. 110V, max 265V) Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%.
6
10W, 20W
Touch-Safe Small Semiconductor
Heater - CSK 060 Series
• Low surface temperature
• Double insulated (plastic housing)
• Wide voltage range
• Temperature limiting
• Dynamic heating up
• Clip fixing
Technical Data:
Operating voltage 120-24V AC/DC* -(min. 110V, max. 265V)
Heating element PTC resistor, temperature limiting
Surface temperature <85ºC (according to VDE 0100) except upper protective grille
Connection 2-pole terminal 2.5mm2, torque 0.8Nm max.
Casing Plastic according to UL94 V-0, black
Dimensions 98 x 38 x 75mm
Mounting Clip for 35mm DIN rail, EN 60715
Fitting position Vertical
Op./storage temp. -45ºC to +70ºC
Prot. type / Prot. class IP20 / II (couble insulated)
Approvals VDE + UL File No. E150057 (according to UL499 in combination with
UL508A)
Note Other voltages on request
*Op. with voltages below 140V AC/DC reduces heating performance by approx. 10%.
Example of connection
7
Finned Extruded Enclosure Heater
Type SAN-FXE
The FXE range of heaters is designed specifically for frost protection, an-
ti-condensation and temperature control within Zone 1 and Zone 2 Ha-
zardous Areas. The FXE delivers a constant power output and comes com-
plete with mounting bracket and a 1.5 metre flying lead.
Features
• Certified to meet the requirements of the ATEX Directive 94/9/EC, Gost
and IECEx.
• Compact design, requires minimal space.
• Optional over-temperature protection.
• Black anodized convective surface.
• Standard product available with short delivery times.
• Suitable for ambient temperatures -50°C up to +80°C.
Typical Applications:
Control / monitoring panels
Instrumentation cabinets
Condensation prevention
Temperature fluctuations
Frost protection
Motor enclosures
Certification
IECEx & ATEX certified Ex II 2 G/D, Ex d IIC (Gas) T3-T4 Gb, Ex t IIIC (Dust) T200-T135°C Db, EN/IEC60079-0 & EN/
IEC60079-1 & EN/IEC 60079-31
Extrusion
Finned Aluminium, Anodized Matt Black
Mounting:
Vertically Mounted by Bracket or Rail
Voltage:
Up to 254VAC
Rating:
Available in 30, 50, 75 & 100 Watts
Controls
If required, heaters can be supplied with a range of remote mounted thermostats.
Element:
18mm dia 321 St/Steel cartridge element with 1.5m silicone flex cable.
Weather protection:
IP6X
8
15W to 150W
Semiconductor
Heater - HG 140 Series
• Pressure clamp connectors
• Dynamic heating up
• Wide voltage range
• Temperature limiting
• Energy saving
• Clip fixing
• Quick installation
Technical Data:
Operating voltage 120-240V AC/DC* (min. 110V, max. 265V)
Heating element PTC resistor, temperature limiting
Heater body Extruded aluminium profile, anodised
Connection 3 pressure clamps for stranded wire 0.5-1.5mm² (with wire end ferrule)
and rigid wire 0.5-2.5mm2
Connection casing Plastic according to UL94 V-0, black
Mounting Clip for 35mm DIN rail, EN 60715
Fitting position Vertical
Op./storage temperature -45 to +70ºC
Prot. type / Prot. class IP20 / I (earthed)
Approvals VDE + UL file E150057
Accessories Screw fixing
*Op. with voltages below 140V AC/DC reduces heating performance by approx. 10%.
Art. No. Heating capacity* Inrush current max. Length (L) Weight (approx.)
83190 15W 1.5A 65mm 0.3kg
83191 30W 3.0A 65mm 0.3kg
83192 45W 3.5A 65mm 0.3kg
83193 60W 2.5A 140mm 0.4kg
83194 75W 4.0A 140mm 0.5kg
83195 100W 4.5A 140mm 0.5kg
83196 150W 9.0A 220mm 0.7kg
*At 20ºC (68˚F) ambient temperature.
9
Compact
Fan Heater - HGL 046 Series
• Compact design
• Temperature safety cut-out
• Clip fixing
• Long service life
• Maintenance free
Technical Data:
Operating voltage AC 220-240V, 50-60Hz
AC 110-120V, 50-60Hz
Other voltages on request (e.g. AC/DC 48V)
Heating element Resistance heater
Temp. safety cut-out To protect against overheating in case of fan failure.
Heater body Extruded aluminium profile, anodised
Surface temperature Max 75°C (400W)
Axial fan Ball bearing service life 50 000h at 25°C (77°F)
airflow 35m³/h, free flow
Connection 3-pole clamp for 2.5mm²
Mounting Clip for 35mm DIN rail, EN 50022
Fitting position Preferably vertical
Op./storage temperature -40 to +70ºC (-40 to +158˚F)
Prot. type / Prot. class IP20/I (earthed)
Approvals VDE, UL file E150057
Art. No. Approval Operating voltage Heating capacity* Length (L) Weight (approx.)
83256 VDE AC 230V, 50-60Hz 250W 170mm 1.0kg
83257 VDE AC 230V, 50-60Hz 400W 252mm 1.3kg
UL AC 115V, 50-60Hz 250W 170mm 1.0kg
83257-1 UL AC 115V, 50-60Hz 400W 252mm 1.3kg
UL AC 230V, 50-60Hz 250W 170mm 1.0kg
UL AC 230V, 50-60Hz 400W 252mm 1.3kg
*At 20ºC (68˚F) ambient temperature.
10
50W, 100W
Hazardous area
Heater - CREx 020 Series
• Large convection surface
• Clip fixing
• Ready for use
• Maintenance free
Compact convection heater for use in areas with explosion hazard for
prevention of formation of condensation, temperature fluctuations and for
protection against frost in transmitter housings, switch cabinets and measur-
ing equipment.
Technical Data:
Explosion protection acc. to EN LCIE (Laboratoire Central des Industries Electriques)
Conformity certificate 01 ATEX 6073/03, LCIE No 06 ATEX Q8011, IECEx LCI 07, 0020
Heating element High performance cartridge
Heater body Aluminium profile, black anodised
Connection Si HF-JZ 3 x 0.75mm2 cable, length 1m
Connection PE 4mm2
Mounting Clip for 35mm DIN rail, EN 60715
Fitting position Vertical
Operating/storage temperature -20 to +40ºC / -45 to 70ºC
Protection type /Protection class IP65 / I (earthed)
Art. No. Operating voltage Heating capacity* Ex protection type Surface temperature Length (L) Weight (approx.)
83197 230-240VAC 50W d IIC T5 - Ex tD A21 IP6X T100˚C 100˚C 150mm 1.3kg
83198 230-240VAC 100W d IIC T4 - Ex tD A21 IP6X T135˚C 135˚C 180mm 1.5kg
110-120VAC 50W d IIC T5 - Ex tD A21 IP6X T100˚C 100˚C 150mm 1.3kg
110-120VAC 100W d IIC T4 - Ex tD A21 IP6X T135˚C 135˚C 180mm 1.5kg
11
Electrical Direct Heater
SAN-LP Heater
Direct-heaters for Hazardous locations, designed for direct
mounting onto e.g. manifolds etc.
• Freeze protection
• Anti-condensation
• Temperature maintenance
• Certified to meet the requirements of the ATEX Directive 94/9/EC, Gost and IECEx.
• Self-limiting heating elements
• Small dimensions
• No moving parts, no maintenance required therefore long lifetime
• Suitable for T4 and T3 classifications
• Can be used for 110 / 240 VAC/DC
Description
All Cameo Heaters are designed around self-limiting heating elements. These self-limiting semi-conductor elements
are saving power consumption. Our Cameo Direct-heaters are designed to heat the installed equipment. If properly
selected for freeze protection, no thermostat will be needed.
Alternative 316 Stainless Steel heaters can be delivered for the 100-10 Watt range.
Also possible is an aluminium body with four holes drilled through (body #5), for easy mounting.
Please see below for further technical data.
Range
LP-
0AHP T3 ca. 130 °C Surface temperature 200-20 Watt
12
Electrical Space Heater
SAN-LP AF Ex Heater
Space-heaters for Hazardous locations, designed for :
• Freeze protection
• Anti-condensation
• Temperature maintenance
Technical Data:
Power consumption 100-10 Watt
Electrical cable 3x1 sqmm
Material cable braided silicone, optional: non-braided cable
Standard length approx. 1 mtr. Other lengths optional
Other lengths To be specified
Overall dimensions 164x100x60mm (LxWxH)
Material black anodized aluminium
EX protection class II 2G Ex d IIC T4 or T3: II 2D Ex tD A21 IP66 T 135°C or T200°C
Certification KEMA 01ATEX2124X and IECEx DEK 11.0017
Protection degree IP66
Voltage 110/240
Ambient temp. range -60°C...+90°C
Description
13
Electrical Smart Heater for Space Heating
SAN-SMLP Ex Heater
Space-heaters for Hazardous locations, this compact
model is designed for
• Anticondensation
• Freeze protection
• Temperature maintenance
• Small spaces
Description
All SMART Space-heaters are designed around self-limiting heating elements. These semi-conductor elements are
saving power consumption.
Our SMART Space-heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If
properly selected for freeze protection, no thermostat will be needed.
In other situations, if the equipment may not exceed a maximum temperature value, you can add our Fix-Therm96
thermostat as a maximum temperature protection, in the system.
When required in other applications, e.g. analyzers, it is normal practice to use our SMART Space-heaters in combi-
nation with our FixTherm96 thermostats (range from 10°C up to 135°C).
Range
14
50W to 150W
Touch-Safe Semiconductor
Heater - CS 060 Series
• Low surface temperature
• Quick mounting due to clip fixing
• Double insulated (plastic)
• Wide voltage range
• Small size
Technical Data:
Operating voltage 120-240V AC/DC* (min. 110V, max. 265V)
Heating element PTC resistor, temperature limiting
Surface temperature <80ºC, except upper protective grille
Connection 4-pole terminal 2,5mm2, torque 0.8Nm max.
Casing Plastic according to UL94 V-0, black
Mounting Clip for 35mm DIN rail, EN 60715
Fitting position Vertical
Op./storage temperature -45 to +70ºC
Prot. type / Prot. class IP20 / II (double insulated)
Approvals VDE + UL file E150057 (according to UL499
in combination with UL508A)
Note Other voltages on request
*Op. with voltages below 140V AC/DC reduces heating performance by approx. 10%.
Thermostat
FTO 011
178
160
capacity
147
150
Heater CS 060
(W)
132
122 119
Heizleistung
93
85
Art. Nr. 16010.0-00
66
61
FTO 011
55
50
50 44
Art. Nr. 16020.0-00
0
-40 -20 0 20 40
Examples of connection
Art. No. Heating capacity1) Inrush current max. Air outlet temp.2) Dimensions Weight (approx.)
50W 2.5A +86ºC 110 x 60 x 90mm 0.3kg
100W 4.5A +120ºC 110 x 60 x 90mm 0.3kg
150W 8A +145ºC 150 x 60 x 90mm 0.5kg
1)
Ambient temperature - see Heating capacity / Ambient temperature diagram; 2)measured 50mm above protective grille.
15
50 W to 150W
Touch-Safe Semiconductor
Heater - CSF 060 Series
• Low surface temperature
• Integrated thermostat
• Quick mounting due to clip fixing
• Double insulated (plastic)
• Wide voltage range
• Small size
Technical Data:
Operating voltage 120-240VAC* (min. 110V, max. 265V)
Heating element PTC resistor, temperature limiting
60
Surface temperature <80ºC, except upper protective grille
Connection 4-pole terminal 2.5mm2, torque 0.8Nm max.
Casing Plastic according to UL94 V-0, black
90
Leistungs-Umgebungstemperatur-Diagramm
Heater CSF 060 Heating capacity / Ambient
CS temperature
160 diagram CSF 060
200
178
Heating capacity (W)
160
147
150
Heizleistung (W)
132
122 119
110 Art. Nr. 16000.0-00
102
100 93
85
Art. Nr. 16010.0-00
66
61
55
50
50 44
Art. Nr. 16020.0-00
Example of connection 0
-40 -20 0 20 40
Umgebungstemperatur (°C)
Temperature (ºC)
Art. No. Heating Inrush current Air outlet Switch-off Starting Dimensions Weight (approx.)
capacity* max. temperature2) temperature3) temperature3)
50W 2.5A +86ºC +15ºC +5ºC 110 x 60 x 90mm 0.3kg
50W 2.5A +86ºC +25ºC +15ºC 110 x 60 x 90mm 0.3kg
100W 4.5A +120ºC +15ºC +5ºC 110 x 60 x 90mm 0.3kg
100W 4.5A +120ºC +25ºC +15ºC 110 x 60 x 90mm 0.3kg
150W 8A +145ºC +15ºC +5ºC 150 x 60 x 90mm 0.5kg
150W 8A +145ºC +25ºC +15ºC 150 x 60 x 90mm 0.5kg
1)
ambient temperature - see Heating capacity / Ambient temperature diagram; 2)measured 50mm above protective grille; 3)tolerance of ±5K.
16
150W
Small Semiconductor
Fan Heater - CS 028
95
• Small, compact design
• Quite in operation
• Dynamic heating up
32 90
95
75
Technical Data:
75
32 90 65
Heating element PTC heating element
Inrush current max. 12A at 230VAC, 6A at 120VAC
Surface temperature max. 50ºC at casing; 100ºC at upper protective grille
at 20ºC ambient temperature.
65 90
Axial fan, ball bearing Air flow 13.8m3/h, free flow (service life 40,000h at 40ºC)
Connection 2-pole clamp max. 2.5mm , clamping screw torque 0.8Nm max.
2
Clip fixing
Heating capacity (W)
65 90
95
75
Temperature (ºC) 32
Example of connection
FAN Heater CS 028
Thermostat KTO 011
(contact breaker, normally closed)
30
20 40
10 50
0 60
3 4
95
75
L
32 N
17
250W, 400W
Compact Semiconductor
Fan Heater - CSL 028
• Small, compact design
• Quiet in operation
• Dynamic heating up
• Clip or screw fixing
Technical Data:
Heating element PTC heating element
Surface temperature 250W: max 50ºC, except upper protective grille
400W: max 65ºC, except upper protective grille
at 20ºC ambient temperature
Axial fan, ball bearing Air flow 45m3/h at 230VAC, air flow 54m3/h at 120VAC
free flow, service life 40,000h at 40ºC
Connection 2-pole clamp max. 2.5mm2 with strain relief,
clamping torque 0.8Nm max.
Casing Plastic acc. to UL94-0, black
Mounting Clip for 35mm DIN rail, EN 60715 or screw fixing (Ø5.3mm)
Fitting position Vertical
View: back side
Weight Approx. 0.5kg
Op./storage temp. -45 to +70ºC Screw fixing Clip fixing
Prot. type / Prot. class IP20 / II (double insulated)
Note Other voltages on request
Example of connection
Thermostat KTO 011 FAN Heater CSL 028
(contact breaker, normally closed)
Temperature (ºC)
Art. No. Operating voltage Heating capacity* Inrush current max. Dimensions Mounting Approvals
83710 230VAC, 50/60Hx 250W 9A 111x85x90mm Clip fixing VDE; (UL submitted)
83711 230VAC, 50/60Hz 250W 9A 111x85x129mm Screw fixing VDE; (UL submitted)
120VAC, 50/60Hz 250W 6A 111x85x90mm Clip fixing UL submitted
120VAC, 50/60Hz 250W 6A 111x85x129mm Screw fixing UL submitted
83715 230VAC, 50/60Hz 400W 15A 111x85x90mm Clip fixing VDE; (UL submitted)
83716 230VAC, 50/60Hz 400W 15A 111x85x129mm Screw fixing VDE; (UL submitted)
120VAC, 50/60Hz 400W 9A 111x85x90mm Clip fixing UL submitted
120VAC, 50/60Hz 400W 9A 111x85x129mm Screw fixing UL submitted
*at 20ºC ambient temperature
18
Electrical Smart Space-Heater, General purpose
SAN-GSMLP Heater
Space-heaters for Non-Hazardous locations are designed for
• Anticondensation
• Freeze protection
• Temperature maintenance
Technical Data:
Power consumption 200-20 Watt
Electrical cable 3x1 sqmm
Material cable non-braided silicone cable
Standard length approx. 1 mtr. Other lengths optional
Other lengths To be specified
Overall dimensions 100x54x54mm (LxWxH)
Weight Approx. 1400g
Material black anodized aluminium
Protection degree IP66
Voltage 110/240
Description
All SMART Space-heaters are designed around self-limiting heating elements. These semi-conductor elements are
saving power consumption.
Our SMART Space-heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If
properly selected for freeze protection, no thermostat will be needed.
In other situations, if the equipment may not exceed a maximum temperature value, you can add our Fix-Therm96
thermostat as a maximum temperature protection, in the system.
When required in other applications, e.g. analyzers, it is normal practice to use our SMART Space-heaters in combi-
nation with our FixTherm96 thermostats (range from 10°C up to 135°C).
19
Explosion proof
Anti Condensation Heater - SP
Space-heaters for Hazardous locations are designed for
• Freeze protection
• Anti-condensation
• Temperature maintenance
Technical Data:
Power consumption 250-25Watt or 500-50Watt
Electrical cable 3x1 sqmm
Material cable Braided silicone (standard) non-braided optional
Standard length approx. 1 mtr. Other lengths optional, on request
Other lengths To be specified
Overall dimensions 165x185x41,6mm (LxWxH)
Weight Approx. 1600g
Material black anodized aluminium
EX protection class II2G Ex d IIC T4 or T3: II2D Ex tD A21 IP66 T135ºC or T200ºC
Certification KEMA 01ATEX2124X and IECEx DEK 11.0017
Protection degree IP66
Voltage 110/240 VAC/DC
Ambient temp. range -60ºC...+90ºC
20
Electrical Smart-Space Heater
Type GSM-*A
Space-heaters for Non-Hazardous locations, designed
for
• Freeze protection
• Anti-condensation
• Temperature maintenance
Technical Data:
Power consumption 250-25Watt or 500-50Watt
Electrical cable 3x1 sqmm
Material cable Non-braided silicone cable
Standard length approx. 1 mtr. Other lengths optional, on request
Other lengths To be specified
Overall dimensions 164x54x54mm (LxWxH)
Weight Approx. 1400g
Material black anodized aluminium
Voltage AC/DC 110/240
Protection class IP66
Description
All Smart Space-Heaters are designed around self-limiting heating elements. These semi-conductor elements are
saving power consumption.
Our Smart Space-Heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If
properly selected for freeze protection, no thermostat will be needed.
When required in other applications, e.g. analyzers, it is normal practice to use our Smart Space-Heaters in combina-
tions with our FixTherm96 (range from 10°C up to 130°C).
21
Electrical Smart-Space Ex Heater
Type SM-*A
Space-heaters for Hazardous locations, designed for
• Freeze protection
• Anti-condensation
• Temperature maintenance
• Small spaces
Features and Advantages
• Self-limiting heating elements
• Small dimensions
• No moving parts, no maintenance required there-
fore long lifetime
• Suitable for T4 and T3 classification
• Can be used for 110 to 240 VAC/DC
Technical Data:
Power consumption 250-25Watt or 500-50Watt
Electrical cable 3x1 sqmm
Material cable Braided silicone (standard) Non-braided optional
Standard length approx. 1 mtr. Other lengths optional, on request
Other lengths To be specified
Overall dimensions 164x54x54mm (LxWxH)
Weight Approx. 400g
Material black anodized aluminium
EX protection class II 2G Ex d IIC T4 or T3: II 2D Ex tD A21 IP66 T 135°C or T200°C
Certification KEMA 01ATEX2124X and IECEx DEK 11.0017
Voltage AC/DC 110/240 VAC/DC
Protection degree IP66
Ambient temp. range -60°C...+90°C
Description
All Smart Space-Heaters are designed around self-limiting heating elements. These semi-conductor elements are
saving power consumption.
Our Smart Space-Heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If
properly selected for freeze protection, no thermostat will be needed.
In other situations, if the equipment may not exceed a maximum temperature value, our Fix-Therm96 thermostat can
be added as a maximum temperature protection, in the system.
When required in other applications, e.g. analyzers, it is normal practice to use our Smart Space-Heaters in combina-
tions with our FixTherm96 (range from 10°C up to 135°C).
22
Electrical Direct Ex Heater
Type CS-*S
Space-heaters for Hazardous locations, designed for
direct mounting onto e.g. manifolds etc.
• Freeze protection
• Anti-condensation
• Temperature maintenance
Features and Advantages
• Self-limiting heating elements
• Small dimensions
• No moving parts, no maintenance required there-
fore long lifetime
• Suitable for T4 and T3 classification
• Can be used for 110 to 240 VAC/DC
Technical Data:
Power consumption 250-25Watt
Electrical cable 3x1 sqmm
Material cable Braided silicone; optional: Non-braided optional
Standard length approx. 1 mtr. Other lengths optional
Other lengths To be specified
Overall dimensions 85x65x28mm (LxWxH)
Weight Approx. 900g
Material stainless steel 316
EX protection class II 2G Ex d IIC T4 or T3: II 2D Ex tD A21 IP66 T 135°C or T200°C
Certification KEMA 01ATEX2124X and IECEx DEK 11.0017
Voltage AC/DC 110/240 VAC/DC
Protection degree IP66
Ambient temp. range -60°C...+90°C
Description
All Cameo Heaters are designed around self-limiting heating elements. These semi-conductor elements are saving
power consumption.
Our Cameo Direct Heaters are designed to heat the installed equipment. If properly selected for freeze protection, no
thermostat will be needed.
23
Electrical Direct Ex Heater
Type CT-*A
Direct heaters for Hazardous locations, designed for
• Freeze protection
• Anti-condensation
• Temperature maintenance
Features and Advantages
• Self-limiting heating elements
• Small dimensions
• No moving parts, no maintenance required there-
fore long lifetime
• Suitable for T4 and T3 classification
• Can be used for 110 to 240 VAC/DC
Technical Data:
Power consumption 250-25Watt
Electrical cable 3x1 sqmm
Material cable Braided silicone; optional: Non-braided optional
Standard length approx. 1 mtr. Other lengths optional
Other lengths To be specified
Overall dimensions 88x70x35mm (LxWxH)
Weight Approx. 550g
Material black anodized aluminium
EX protection class II 2G Ex d IIC T4 or T3: II 2D Ex tD A21 IP66 T 135°C or T200°C
Certification KEMA 01ATEX2124X and IECEx DEK 11.0017
Voltage AC/DC 110/240 VAC/DC
Protection degree IP66
Ambient temp. range -60°C...+90°C
Description
All Cameo Heaters are designed around self-limiting heating elements. These semi-conductor elements are saving
power consumption.
Our Cameo Direct Heaters are designed to heat the installed equipment. If properly selected for freeze protection, no
thermostat will be needed.
24
Anti Condensation & Space Heater
Type SAN-HEF Hazardous Area
The self-regulating properties of the HEF enclosure hea-
ters eliminate the requirement for a thermostat. Coupled
with the compact design, this makes the HEF ideal for anti
condensation, frost protection and temperature control
where the enclosure is located within Zone 1 and Zone 2
Hazardous Areas.
Certified to ATEX Directive 94/9/EC IECEx, they are suitable
for use where the flammable atmosphere is Group IIA, IIB or
IIC Gas.
Features
• Certified to meet the requirements of the ATEX Directive 94/9/EC, Gost and IECEx.
• Compact, low profile, stainless steel case, requires minimal space.
• Self-regulating - can be used without a thermostat.
• Suitable for ambient temperatures from -60° to +80°C.
• Mounting of the heater can be in any orientation.
• Design allows installation close to internal components and cables without fear of damage by overheating.
Typical Applications:
Control / monitoring panels
Instrumentation cabinets
Condensation prevention
Temperature fluctuations
Frost protection
Certification
ATEX certified Ex II 2 G
IECEx & ATEX certified Ex’e’ T4
EN/IEC60079-0 & EN/IEC60079-7
Casing
Perforated stainless steel
Element
Self-regulating
Controls
The HEF is self-regulating, automatically reducing its output as the ambient temperature rises if overall enclosure
temperature control is required it is recommended that the HEF heater is used in conjunction with one of the Ex’d’
thermostats.
Mounting
The heater may be mounted in any orientation, using appropriate securing bolts through the mounting feet.
Rating
The HEF range is available in a nominal 30, 50, 100, 200 & 500 Watt outputs, models available for 110V or 230-240V
single phase supplies.
25
100W to 400W
Space-saving
Fan Heater HV/HVL 031 Series
• Compact
• Flat design
• High air flow
• Temperature safety cut-out
• Clip fixing
Technical Data:
HV 031 Heater without fan (fan mounting kit included)
HVL 031 Heater with fan
Heating element High performance cartridge
Temp. safety cut-out To protect against overheating in case of fan failure
Heater body Die-cast aluminium (glass bead blasted)
Connection 3-pole screw connector 2.5mm², clamping torque 0.8Nm max.
Connection casing Plastic acc. to UL94 V-0, black
Mounting Clip for 35mm DIN rail, EN 60715
Fitting position Horizontal
Op./storage temp. -45 to +70ºC
Prot. type / Prot. class IP20/I (earthed)
Approvals UL file E187294 (230V only: VDE)
HVL 031 only:
Axial fan, ball bearing Airflow see table
Service life 50,000h at 25°C
Connection (axial fan) 2-pole screw connector 2.5mm2 (L2/N2)
a.) Clip
Important! Heater may only be b.) Type plate
operated together with fan. c.) Axial fan
d.) Air direction
Danger of overheating!
Art. No. HV 031 Art. No. HV 031 Heating capacity Dimensions Weight (approx.)
230VAC, 50/60Hz 120VAC, 50/60Hz
83275 100W 80x112 22mm 0.4kg
83276 150W 80x112x22mm 0.4kg
83277 200W 119x151x22mm 0.5kg
83278 300W 119x151x22mm 0.5kg
83279 400W 119x151x22mm 0.5kg
Art. No. HVL 031 Art. No. HVL 031 Heating capacity Airflow min., Dimension Weight (Approx.)
230VAC, 50/60Hz 120VAC, 50/60Hz free flow
83178 100W 35m3/h 80x112x47mm 0.6kg
83179 150W 35m3/h 80x112x47mm 0.6kg
83180 200W 108m3/h 119x151x47mm 0.9kg
83181 300W 108m3/h 119x151x47mm 0.9kg
83182 400W 108m3/h 119x151x47mm 0.9kg
26
up to 650W
Semiconductor
Fan Heater - CR 027 Series
• Compact heater
• Heating capacity adjusts to ambient temperature
• Adjustable temperature range
• Clip fixing
• Optical indicator
• Temperature safety cut-out
Technical Data:
Heating element PTC resistor, temperature limiting
Temp. safety cut-out To protect against overheating in case of fan failure
Axial fan, ball bearing Airflow see table
service life 50,000h at 25°C
Connection 2-pole clamp 2.5mm2, clamping torque 0.8Nm max.
Casing Plastic, according to UL94 V-0, light grey
Optical indicator Thermostat control lamp
Mounting Clip for 35mm DIN rail, EN 60715
Fitting position Vertical
Op./storage position -45 to +70ºC
Dimensions 100 x 128 x 165mm
Prot. type / Prot. class IP20 / II (double insulated)
Approvals UL file E204590
Art. No. Operating Heating capacity* Heating capacity* Inrush Airflow, Setting range Weight
voltage (50Hz) (60Hz) current max. free flow Temp. regulator (approx)
83285 220-240VAC, 50/60Hz 475W 550W 11.0A 35m3/h 0 to +60°C 0.9kg
83286 220-240VAC, 50/60Hz 550W 650W 13.0A 45m3/h 0 to +60ºC 1.1kg
83287 100-120VAC, 50/60Hz 400W 550W 14.0A 35m3/h +32 to +140°F 0.9kg
83288 100-120VAC, 50/60Hz 510W 650W 15.0A 45m3/h +32 to +140ºF 1.1kg
* At 20ºC (68˚F) ambient temperature.
27
950W
Compact high-performance
Fan Heater - CR 030
• Compact design
• Double insulated
• Integrated thermostat or hygrostat
Technical Data:
Heating element High performance cartridge
Temp. safety cut-out to protect against overheating in case of fan failure,
automatic reset
Heater body extruded aluminium profile
Axial fan, ball bearing Airflow 160m3/h, free flow
service life 50,000h at 25°C
Connection 2-pole clamp max. 2.5mm2, clamping screw with strain relief, torque
0.8Nm max.
Casing Plastic according to UL94-0, black
Mounting Screw fixing (M5)
Fitting position Horizontal
Dimensions 168 x 145 x 100mm
Weight Approx. 1.4kg
Op.*/storage temp. -45 to +70ºC
Prot. type / Prot. class IP20 / II (double insulated)
Note Other heating capacities from 200W up available on request.
Connection diagram
Art. No. Model Operating voltage Heating capacity Setting range Approvals
Fan Heater with thermostat 230VAC, 50/60Hz 950W 0 to +60°C VDE + UL File No. E234324*
Fan Heater with hygrostat 230VAC, 50/60Hz 950W 65% RH, factory-set VDE + UL File No. E234324*
Fan Heater with thermostat 120VAC, 50/60Hz 950W +32 to +140°F UL File No. E234324*
*according to UL499 in combination with UL508A
28
950W
Compact high-performance
Fan Heater - CR 130
• Compact design
• Double insulated
• Integrated thermostat or hygrostat
• Optional clip or screw fixing
Technical Data:
Heating element High performance cartridge
Temp. safety cut-out to protect against overheating in case of fan failure,
automatic reset
Heater body Extruded aluminium profile
Axial fan, ball bearing Airflow 160m3/h, free flow
service life 50,000h at 25°C
Connection 2-pole max. 2.5mm2, clamping screw with strain relief, torque 0.8Nm
max.
Casing Plastic according to UL94 V-0, black
Mounting Clip for 35mm DIN rail, EN 60715 or screw fixing (M6)
Fitting position Horizontal
Dimensions 182 x 160 x 99mm
Weight Approx. 1.5kg
Op.*/storage temp. -45 to +70ºC
Prot. type / Prot. class IP20 / II (double insulated)
Note Other heating capacities from 200W up available on request.
Connection diagram
Art. No. Model Operating voltage Heating capacity Setting range Approvals
Fan Heater with thermostat 230VAC, 50/60Hz 950W 0 to +60°C VDE + UL File No. E234324*
Fan Heater with hygrostat 230VAC, 50/60Hz 950W 65% RH, factory-set VDE + UL File No. E234324*
Fan Heater with thermostat 120VAC, 50/60Hz 950W +32 to +140°F UL File No. E234324*
29
1,200W
Compact high-performance semiconductor
Fan Heater - CS 030
• Compact design
• High heating performance
• Double insulated
• Integrated thermostat (optional)
Technical Data:
Heating element PTC resistor - temperature limiting
Temp. safety cut-out to protect against overheating in case of fan failure
Axial fan, ball bearing Airflow 160m3/h, free flow
service life 50,000h at 25°C
Connection 2-pole clamp max. 2.5mm2, clamping screw with strain relief, torque
0.8Nm max.
Casing Plastic according to UL94-0, black
Mounting Screw fixing (M5)
Fitting position Horizontal
Dimensions 168 x 145 x 120mm
Weight Approx. 1.2kg
Op./storage temp. -45 to +70ºC
Prot. type / Prot. class IP20 / II (double insulated)
Art. No. Model Operating voltage Heating capacity1) Inrush current max. Setting range Approvals
83268 Fan Heater with thermostat 230VAC, 50/60Hz 1,200W 13A 0 to +60°C VDE + UL File No. E2343242)
83269 Fan Heater without thermostat 230VAC, 50/60Hz 1,200W 13A - VDE + UL File No. E2343242)
Fan Heater with thermostat 120VAC, 50/60Hz 1,200W 16A +32 to +140°C UL File No. E2343242)
Fan Heater without thermostat 120VAC, 50/60Hz 1,200W 16A - UL File No. E2343242)
1)
at 20°C ambient temperature; 2)according to UL499 in combination with UL508A
30
1,200W
Compact high-performance semiconductor
Fan Heater - CS 130
• Compact design
• High heating performance
• Double insulated
• Integrated thermostat (optional)
• Optional clip or screw fixing
Technical Data:
Heating element PTC resistor - temperature limiting
Temp. safety cut-out to protect against overheating in case of fan failure
Axial fan, ball bearing Airflow 160m3/h, free flow
service life 50,000h at 25°C
Connection 2-pole max. 2.5mm2, clamping screw with strain relief, torque 0.8Nm
max.
Casing Plastic according to UL94 V-0, black
Mounting Clip for 35mm DIN rail, EN 60715 or screw fixing (M6)
Fitting position Horizontal
Dimensions 182 x 160 x 120mm
Weight Approx. 1.3kg
Op.*/storage temp. -45 to +70ºC
Prot. type / Prot. class IP20 / II (double insulated)
Temperature (ºC)
Connection diagram
Art. No. Model Operating voltage Heating capacity1) Inrush current max. Setting range Approvals
83266 Fan Heater with thermostat 230VAC, 50/60Hz 1,200W 13A 0 to +60°C VDE + UL File No. E2343242)
83267 Fan Heater without thermostat 230VAC, 50/60Hz 1,200W 13A - VDE + UL File No. E2343242)
Fan Heater with thermostat 120VAC, 50/60Hz 1,200W 16A +32 to +140°F UL File No. E2343242)
Fan Heater without thermostat 120VAC, 50/60Hz 1,200W 16A - UL File No. E2343242)
1)
at 20°C ambient temperature; 2)according to UL499 in combination with UL508A
31
21m3/h to 102m3/h
Filter Fan FF 018 Series
Filter fans are used to provide an optimum climate in enclosures. The interior
temperature of an enclosure can be reduced by channelling cooler filtered
outside air into the enclosure thus expelling heated internal air. The resulting
air flow prevents formation of localised hot pockets and protects the elec-
tronic components from overheating. The plastic used for the hood of this
filter fan series is highly weather proof and UV light resistant.
Technical Data:
Axial fan, ball bearing Service life 50,000h at 25°C (65% RH)
fan body aluminium, rotor plastic
Connection 2 wires with pressure clamps 2.5mm2, length 100mm
Casing (filter fan and exit filter) Plastic according to UL94-V-0, light grey
Hood (filter fan and exit filter) Plastic according to UL94 V-0, light grey;
weather proof and UV light resistant according to UL746C (f1)
Mounting frame with double-sided industrial adhesive band for fixing to the outside of
enclosure; certain operating circumstances can make the additional
use of screws necessary (see drilling template); included in the delivery
of the filter fans is a template for the enclosure cut-out.
Filter mat G4 acc. to DIN EN 779, filtering degree 94%
Filter material Synthetic fibre with progressive construction, temperature resistant
to 100°C, self-extinguishing class F1; moisture resistant to 100% RH,
reusable - cleaning by washing or vacuuming
Op./storage temp. -45 to +70ºC
Prot. type / Prot. class IP54* / I (earthed)
*Using fine filter mats type F5 increases the protection type to IP55, bt reduces the air volume.
Special features:
• The self-adhesive seal of the mounting frame prevents dust and water from entering the cabinet.
• Functional design of the intake and exit fan hoods very effectively prevents direct intrusion of falling
water and dust. The advantage is that the filter mat does not get so quickly contaminated with dirt and
thus does not need to be exchanged so often.
• The air channelling makes the filter fan particularly quiet in operation.
• Functional and modern design enables time-saving assembly and maintenance.
• All filter fan models are also available with integrated airflow monitor.
• EMC versions and other voltages on request.
• The direction of air can easily be switched by reversing the axial fan (sizes 1 to 3).
Art. No. Operating Air volume, Air volume Current Power Average noise Depth in Enclosure Weight Approvals
voltage free flow with consump- consump- level (DIN EN enclosure cut-out (approx.)
exit filter tion tion ISO 4871)
230VAC, 21m3/h 16m3/h 80mA 13W 31dB (A) 45mm 97 x 97mm 0.6kg VDE + UL File
50Hz +0.4 No. E234324
230VAC, 55m3/h 42m3/h 100mA 15W 40dB (A) 58mm 125 x 1.0kg VDE + UL File
50Hz 125mm +0.4 No. E234324
230VAC, 102m3/h 68m3/h 100mA 15W 39dB (A) 86mm 176 x 1.3kg VDE + UL File
50Hz 176mm +0.4 No. E234324
120VAC, 24m3/h 18m3/h 160mA 13W 31dB (A) 45mm 97 x 97mm 0.6kg UL File No.
60Hz +0.4 E234324
120VAC, 63m3/h 48m3/h 180mA 15W 40dB (A) 58mm 125 x 1.0kg UL File No.
60Hz 125mm +0.4 E234324
120VAC, 117m3/h 78m3/h 180mA 15W 39dB (A) 86mm 176 x 1.3kg UL File No.
60Hz 176mm +0.4 E234324
32
Filter Fan FF 018 Series
Time-saving assembly and maintenance
SAN’s filter fans are easily installed by one person from outside the cabinet.
1. Make cut-out in the cabinet wall. The cut edge of the cabinet opening
should be free of dirt, fillings and grease. A template for the enclosure cut-
out is included in the delivery of the filter fan.
2. Remove protective film from the sealing strips on the mounting frame.
Press mounting frame into the cabinet opening. The frame stays perma-
nently in the cabinet. (For size 176mm and up we recommend additional
screw fixing.)
3. Electrically connect the axial fan using the clip connectors. Push the unit
into the mounting frame. Fix using screws.
4. Insert the filter mat in the hood. Clip on. Finished.
Changing the filter mat or fan is quickly done by one person. To change the filter
Installation sketch
mat simply remove the filter hood, insert the new mat and snap the hood back
again. No tools required. Maintenance of the fan can easily be done without
removing the mounting frame (2).
Dimensional Drawing
Size 1 Size 2 Size 3
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type
16mm 97x97mm +0.4 0.3kg G4 acc. to DIN EN 779, filtering degree 94% IP54*
16mm 125x125mm +0.4 0.4kg G4 acc. to DIN EN 779, filtering degree 94% IP54*
16mm 176x176mm +0.4 0.6kg G4 acc. to DIN EN 779, filtering degree 94% IP54*
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Art. No. Operating Air volume, Air volume with Current con- Power Average noise Depth in Enclosure cut-out Weight
voltage free flow exit filter sumption consump- level (DIN EN enclosure (approx.)
tion ISO 4871)
230VAC, 50Hz 21m3/h 16m3/h 80mA 13W 31dB (A) 45mm 97 x 97mm +0.4 0.6kg
230VAC, 50Hz 55m /h
3
42m3/h 100mA 15W 40dB (A) 58mm 125 x 125mm +0.4 1.0kg
230VAC, 50Hz 102m3/h 68m3/h 100mA 15W 39dB (A) 86mm 176 x 176mm +0.4 1.3kg
120VAC, 60Hz 24m3/h 18m3/h 160mA 13W 31dB (A) 45mm 97 x 97mm +0.4 0.6kg
120VAC, 60Hz 63m3/h 48m3/h 180mA 15W 40dB (A) 58mm 125 x 125mm +0.4 1.0kg
120VAC, 60Hz 117m3/h 78m3/h 180mA 15W 39dB (A) 86mm 176 x 176mm +0.4 1.3kg
For techinal data see Airflow Monitor LC 013/LCF 013 (Normally Closed, Normally Open)
33
200m3/h
Filter Fan FF 018 Series
• Low maintenance
• High through-flow air volume
• Functional design
• Time-saving installation
• Weather proof and UV resistant
Filter fans are used to provide an optimum climate in enclosures. The interior
temperature of an enclosure can be reduced by channelling cooler filtered
outside air into the enclosure thus expelling heated internal air. The resulting
air flow prevents formation of localised hot pockets and protects the elec-
tronic components from overheating. The plastic used for the hood of this
filter fan series is highly weather proof and UV light resistant.
Technical Data:
Axial fan, ball bearing Service life 50,000h at 25°C (65% RH) Filter Fan
fan body aluminium, rotor metal
Connection 3-pole clamp for 2.5mm2, clamping torque 0.8Nm max.
Casing (filter fan and exit filter) Plastic according to UL94-V-0, light grey
Hood (filter fan and exit filter) Plastic according to UL94 V-0, light grey;
weather proof and UV light resistant according to UL746C (f1)
Mounting frame with double-sided industrial adhesive band for fixing to the outside of
enclosure; certain operating circumstances can make the additional use of
screws necessary (see drilling template); included in the delivery of the filter View from Exit filter
fans is a template for the enclosure cut-out. rear
Filter mat G4 acc. to DIN EN 779, filtering degree 94%
Filter material Synthetic fibre with progressive construction, temperature resistant to
100°C, self-extinguishing class F1; moisture resistant to 100% RH, reusable
- cleaning by washing or vacuuming
Op./storage temp. -45 to +70ºC
Prot. type / Prot. class IP54* / I (earthed)
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Airflow monitor integrated Drilling template
in protective grille of filter for mounting
Filter Fan FF 018 Series fan, e.g. Art. no. frame
Art. No. Operating Air volume, Air volume Current Power Average noise Depth in Enclosure Weight Approvals
voltage free flow with consump- consump- level (DIN EN enclosure cut-out (approx.)
exit filter tion tion ISO 4871)
230VAC, 200m3/h 125m3/h 320mA 45W 52dB (A) 95mm 176x176mm 1.7kg UL File No.
50Hz +0.4 E234324
120VAC, 230m3/h 143m3/h 470mA 39W 52dB (A) 95mm 176x176mm 1.7kg UL File No.
60Hz +0.4 E234324
Exit filter EF 118 Series
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type
16mm 176x176mm +0.4 0.6kg G4 acc. to DIN EN 779, filtering degree 94% IP54*
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
34
300m3/h
Filter Fan FF 018 Series
Filter fans are used to provide an optimum climate in enclosures. The interior
temperature of an enclosure can be reduced by channelling cooler filtered
outside air into the enclosure thus expelling heated internal air. The resulting
air flow prevents formation of localised hot pockets and protects the elec-
tronic components from overheating. Four integrated axial fans provide a
particularly high and uniform air circulation thus contributing to higher reli-
ability. The plastic used for the hood of this filter fan series is highly weather
proof and UV light resistant.
Technical Data:
4x Axial fan
Axial fan, ball bearing Service life 50,000h at 25°C (65% RH)
fan body aluminium, rotor metal
Connection 3-pole clamp for 2.5mm2, clamping torque 0.8Nm max.
Casing (filter fan and exit filter) Plastic according to UL94-V-0, light grey
Hood (filter fan and exit filter) Plastic according to UL94 V-0, light grey;
weather proof and UV light resistant according to UL746C (f1)
Mounting frame with double-sided industrial adhesive band for fixing to the outside of enclo-
sure; certain operating circumstances can make the additional use of screws
necessary (see drilling template); included in the delivery of the filter fans is a
template for the enclosure cut-out.
Filter mat G4 acc. to DIN EN 779, filtering degree 94% View from Exit filter
rear
Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C,
self-extinguishing class F1; mooisture resistant to 100% RH, reusable -
cleaning by washing or vacuuming
Op./storage temp. -45 to +70ºC
Prot. type / Prot. class IP54* / I (earthed)
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Drilling template
for mounting
Filter Fan FF 018 Series frame
Art. No. Operating Air volume, Air volume Current Power Average noise Depth in Enclosure Weight Approvals
voltage free flow with consump- consump- level (DIN EN enclosure cut-out (approx.)
exit filter tion tion ISO 4871)
230VAC, 300m3/h 230m3/h 400mA 60W 53dB (A) 65mm 250x250mm 3.3kg UL File No.
50Hz +0.4 E234324
120VAC, 345m3/h 264m3/h 700mA 60W 53dB (A) 65mm 250x250mm 3.3kg UL File No.
60Hz +0.4 E234324
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type
22mm 250x250mm +0.4 1.0kg G4 acc. to DIN EN 779, filtering degree 94% IP54*
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Filter Mats FM 086 / FFM 086
Filter mat 247x247mm
G4 (1 packing unit = 3 pcs) Art. no.
F5 (1 packing unit = 3 pcs) Art. no.
35
550m3/h
Filter Fan FF 018 Series
Filter fans are used to provide an optimum climate in enclosures. The interior
temperature of an enclosure can be reduced by channelling cooler filtered
outside air into the enclosure thus expelling heated internal air. The resulting
air flow prevents formation of localised hot pocket and protects the electron-
ic components from overheating. The high-performance axial fan provides
high air circulation. The plastic used for the hood of this filter fan series is
highly weather proof and UV light resistant.
Technical Data:
Filter Fan
Axial fan, ball bearing Service life 50,000h at 25°C (65% RH)
fan body aluminium, rotor metal
Connection 3-pole clamp for 2.5mm2, clamping torque 0.8Nm max.
Casing (filter fan and exit filter) Plastic according to UL94-V-0, light grey
Hood (filter fan and exit filter) Plastic according to UL94 V-0, light grey;
weather proof and UV light resistant according to UL746C (f1)
Mounting frame with double-sided industrial adhesive band for fixing to the outside of enclo-
sure; certain operating circumstances can make the additional use of screws
necessary (see drilling template); included in the delivery of the filter fans is a
template for the enclosure cut-out. View from Exit filter
rear
Filter mat G4 acc. to DIN EN 779, filtering degree 94%
Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C,
self-extinguishing class F1; moisture resistant to 100% RH, reusable - clean-
ing by washing or vacuuming
Op./storage temp. -45 to +70ºC
Prot. type / Prot. class IP54* / I (earthed)
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume. Airflow monitor integrated
in protective grille of filter Drilling template
fan, e.g. Art. no. for mounting
Filter Fan FF 018 Series frame
Art. No. Operating Air volume, Air volume Current Power Average noise Depth in Enclosure Weight Approvals
voltage free flow with consump- consump- level (DIN EN enclosure cut-out (approx.)
exit filter tion tion ISO 4871)
230VAC, 550m3/h 300m3/h 300mA 64W 65dB (A) 107mm 250x250mm 2.7kg UL File No.
50Hz +0.4 E234324
120VAC, 632m3/h 345m3/h 780mA 85W 65dB (A) 107mm 250x250mm 2.7kg UL File No.
60Hz +0.4 E234324
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type
22mm 250x250mm +0.4 1.0kg G4 acc. to DIN EN 779, filtering degree 94% IP54*
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Filter Mats FM 086 / FFM 086
Filter mat 247x247mm
G4 (1 packing unit = 3 pcs) Art. no.
F5 (1 packing unit = 3 pcs) Art. no.
Art. No. Operating Air volume, Air volume with Current con- Power Average noise Depth in Enclosure cut-out Weight
voltage free flow exit filter sumption consump- level (DIN EN enclosure (approx.)
tion ISO 4871)
230VAC, 50Hz 550m3/h 300m3/h 300mA 64W 65dB (A) 107mm 250x250mm +0.4 2.7kg
120VAC, 60Hz 632m3/h 345m3/h 780mA 85W 65dB (A) 107mm 250x250mm +0.4 2.7kg
36
Outdoor
Filter Fan - FF 018 Series
The outdoor filter fan can be used in outdoor enclosures where warm air has
to be dissipated on account of increased thermic development. To clean and
exchange the filter mat, it is only necessary to open the lockable door of the
outdoor hood. A protection type of IP55 is achieved due to the special de-
sign of the hood and the use of fine filter mats. The plastic casing is impact
resistant, highly weather proof and resistant to UV light.
Technical Data:
Axial fan, ball bearing Service life min. 50,000h at 25°C (65% RH)
fan body aluminium, rotor plastic
Connection 2 wires with pressure clamps 2.5mm2, length 100mm
Casing (filter fan and exit filter) Casing material high impact plastic ASA, light grey burning behaviour ac-
cording to UL94 H-B; high resistance to weather and UV
Mounting frame with double-sided industrial adhesive band for fixing to the outside of enclo-
sure; certain operating circumstances can make the additional use of screws
necessary (see drilling template); included in the delivery of the filter fans is a
template for the enclosure cut-out.
Filter mat F5 acc. to DIN EN 779, filtering degree 98%
Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C,
self-extinguishing class F1; moisture resistant to 100% RH
Op./storage temp. -45 to +70ºC
Prot. type / Prot. class IP55 / I (earthed)
Approvals UL File No. E234324 View from Outdoor Exit filter
rear
The hood is fixed permanently to the enclosure from the inside using screws. Filter mats can be easily
changed from outside the enclosure through the lockable door in the hood.
Drilling template
for mounting
Filter Fan with Airflow Monitor FFLC 218 (Normally Closed) frame
Art. No. Operating voltage Air volume, Current con- Power Average noise level Depth in Enclosure cut-out Weight
free flow sumption consump- (DIN EN ISO 4871) enclosure (approx.)
tion
230VAC, 50Hz 20m3/h 100mA 15W 40dB (A) 62mm 125x125mm +0.4 1.2kg
120VAC, 60Hz 23m3/h 180mA 15W 40dB (A) 62mm 125x125mm +0.4 1.2kg
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type
16mm 125x125mm +0.4 0.6kg F5 acc. to DIN EN 779, filtering degree 98% IP55
37
350m3/h
Low noise
Roof Filter Fan - RFF 018 Series
• Very low noise
• Minimal depth in enclosure
• High through-flow air volume
• Uniform air circulation
• High reliability
• Time-saving installation
Technical Data:
Axial fans, ball bearing Service life 50,000h at 25°C (65% RH)
fan body aluminium, rotor plastic
Connection 3-pole clamp for 2.5mm2
Casing Plastic according to UL94-V-0 / lacquered steel sheet, light grey
Filter mat G3 acc. to DIN EN 779, filtering degree 85%
Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C,
self-extinguishing class F1; moisture resistant to 100% RH, reusable - clean-
ing by washing or vacuuming
Op./storage temp. -45 to +70ºC
Prot. type IP43 (with filter mat G3 / IP33 (without filter mat)
Prot. class I (earthed)
Approvals UL FIle No. E234324 View from Roof Exit filter
below REF 118
Important note: For reasons of pressure compensation the roof filter fan must always be operated in combi-
nation with another filter fan (e.g. Art. No. ) or a passive intake filter (e.g. Art. No.).
Hole centers
Enclosure cut-out
Roof Filter Fan RFF 018 Series
Art. No. Operating Air volume, Air volume with Current con- Power Average noise Depth in Enclosure cut-out Weight
voltage free flow exit filter sumption consump- level (DIN EN enclosure (approx.)
tion ISO 4871)
230VAC, 50Hz 350m3/h (w/ 500m3/h (w/o 400mA 60W 55dB (A) 44mm 250x250mm +0.4 4.4kg
filter mat G3) filter mat)
120VAC, 60Hz 402m3/h (w/ 575m3/h (w/o 700mA 60W 55db (A) 44mm 250x250mm +0.4 4.4kg
filter mat G3) filter mat)
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type
none 250x250mm +0.4 2.0kg G3 acc. to DIN EN 779, filtering degree 85% IP43 (w/filter mat)
38
High-performance
19” Fan Tray - LE 019 Series
Compact high performance fan tray for enforced circulation of air in switch
and server enclosures and for concerted cooling of 19” component groups.
Natural convection is improved and the formation of localised hot pockets is
avoided. Also available with integrated thermostat (see photo).
Technical Data:
Axial fans, ball bearing Service life 50,000h at 25°C (65% RH)
fan body aluminium, rotor plastic
Material Front panel aluminium, bright anodised
casing steel sheet, electrogalvanized
Optical indicator Integrated in front panel
Connection Appliance power inlet on rear of casing, plug included
Fitting position Horizontal (direction of air upwards)
Op./storage temp. -45 to +70ºC
Prot. type / Prot. class IP20 / I (earthed)
Approvals UL FIle No. E234324
Note:
We recommend using the fan tray in combination with our dual thermostat (ZR 011) for regulating temperature
in electronic enclosures and for protection against overheating due to possible fan failure. The dual ther-
mostat regulates the operation of the fan tray and when connected to a signal device also triggers an early
warning if the enclosure interior temperature rises above a set limit.
When using a fan tray with integrated thermostat, the use of an additional thermostat (KTS 011) provides the
extra safety of activating a signal device.
Art. No. Model No. of Operating Air flow, Power Average noise Speed (rpm-1) Impact Weight
fans voltage free flow consumption level (DIN EN pressure (approx.)
ISO 4871)
without thermostat 3 230VAC, 50Hz 486m3/h 45W 55dB (A) 2600 min-1 (50Hz) 74Pa 3.0kg
with thermostat 0 to +60°C 3 230VAC, 50Hz 486m /h
3
45W 55db (A) 2600 min-1 (50Hz) 74Pa 3.4kg
without thermostat 6 230VAC, 50Hz 972m3/h 90W 57dB (A) 2600 min-1 (50Hz) 74Pa 5.3kg
with thermostat 0 to +60°C 6 230VAC, 50Hz 972m3/h 90W 57dB (A) 2600 min-1 (50Hz) 74Pa 5.7kg
without thermostat 9 230VAC, 50Hz 1458m3/h 135W 58dB (A) 2600 min-1 (50Hz) 74Pa 7.8kg
with thermostat 0 to +60°C 9 230VAC, 50Hz 1458m3/h 135W 58dB (A) 2600 min-1 (50Hz) 74Pa 7.9kg
without thermostat 3 120VAC, 60Hz 576m3/h 45W 55dB (A) 2900 min-1 (60Hz) 88Pa 3.0kg
with thermostat 0 to +60°C 3 120VAC, 60Hz 576m3/h 45W 55dB (A) 2900 min-1 (60Hz) 88Pa 3.4kg
without thermostat 6 120VAC, 60Hz 1152m3/h 90W 57dB (A) 2900 min-1 (60Hz) 88Pa 5.3kg
with thermostat 0 to +60°C 6 120VAC, 60Hz 1152m3/h 90W 57dB (A) 2900 min-1 (60Hz) 88Pa 5.7kg
witout thermostat 9 120VAC, 60Hz 1728m3/h 135W 58dB (A) 2900 min-1 (60Hz) 88Pa 7.8kg
with thermostat 0 to +60°C 9 120VAC, 60Hz 1728m3/h 135W 58dB (A) 2900 min-1 (60Hz) 88Pa 7.9kg
39
24VDC + 48VDC
Technical Data:
Contact type Contact maker, normally open (Relay/MOSFET)
Contact resistance <10mΩ
Service life >100,000 cycles
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3
Connection 6-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715
Casing Plastic according to UL94 V-0, light grey
Dimensions 67x50x46mm
Weight Approx. 90g
Fitting position Variable
Op./storage temp. -45 to +70°C
Protection type IP20
Approvals VDE submitted
e.g.
Temperature
regulator
Load e.g. heater, Switch Module, Control contact, Load, e.g. heater, Switch Module, Control contact,
cooling device with SM 010 e.g. temperature, cooling device without SM 010 e.g. temperature,
temperature cut-out humidity or pressure temperature cut-out humidity or pressure
regulator regulator
Fan
40
Small, compact
Thermostat - KTO/KTS 011
KTO 011: Thermostat (normally closed), contact breaker for regulating heat-
ers.
KTS 011: Thermostat (normally open), contact maker for regulating of filter
fans and heat exchangers or for switching signal devices when temperature
limit has been exceeded.
Technical Data:
Switch temperature difference 7K (±4K tolerance)
Sensor element Thermostatic bimetal
Contact type Snap-action contact
Contact resistance <10mΩ
Service life >100,000 cycles
Max. switching capacity 250VAC, 10 (2) A
120VAC, 15 (2) A
DC 30W
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3
Connection 2-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715 (or for exit filter EF 118 Series)
Casing Plastic according to UL94 V-0, light grey
Dimensions 60x33x43mm
Weight Approx. 40g
Fitting position Variable
Thermostat Thermostat
Op/storage temp. -45 to +80°C
KTO 011 (NC) KTS 011 (NO)
Protection type IP20
Filter fan,
Cooling equipment,
Signal device
Setting range Art. No. Contact Breaker (NC) Art. No. Contact Maker (NO) Approvals
0 to +60°C VDE
-10 to +50°C VDE
+20 to +80°C VDE
+32 to +140°F UL File No. E164102
+14 to +122°F UL File No. E164102
0 to +60°C UL File No. E164102
41
Tamperproof (Pre-set)
Thermostats - FTO/FTS 011
• Small size
• Default temperature settings
• Easy to install
• High switching tolerance
Technical Data:
Sensor element Thermostatic bimetal
Contact type Snap-action contact
Contact resistance <20mΩ
Service life >100,000 cycles
Max. switching capacity 250VAC, 5 (1.6) A
120VAC, 10 (2) A
DC 30W
Max. inrush current AC 10A
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3
Connection 2-pole terminal for 2.5mm2, torque 0.8Nm max.
Mounting Clip for 35mm DIN rail, EN60715
Casing Plastic according to UL94 V-0, light grey
Dimensions 47x33x33mm
Weight Approx. 30g
Fitting position Variable
Op/storage temp. -20 to +80°C / -45 to +80°C
Protection type IP20
Approvals VDE + UL File No. E164102
Example of connection
42
Dual
Thermostat - ZR 011
Technical Data:
Switch temperature difference 7K (±4K tolerance)
Sensor element Thermostatic bimetal
Contact type Snap-action contact
Contact resistance <10mΩ
Service life >100,000 cycles
Max. switching capacity 250VAC, 10 (2) A
120VAC, 15 (2) A
DC 30W
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3
Connection 4-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715
Casing Plastic according to UL94 V-0, light grey
Dimensions 67x50x46mm
Weight Approx. 90g
Fitting position Variable Thermostat
Op/storage temp. -45 to +80°C ZR 011 (NC/NO)
Protection type IP20
Approvals UL File No. E164102
Heater
Filter fan,
Cooling equipment,
Signal device
Connection diagram
43
Tamperproof (Pre-set)
Dual-Thermostat - FTD 011
Technical Data:
Sensor element Thermostatic bimetal
Contact type Snap-action contact
Contact resistance <20mΩ
Service life >100,000 cycles
Max. switching capacity 250VAC, 5 (1.6) A
120VAC, 10 (2) A
DC 30W
Max. inrush current AC 10A
EMC ac. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3
Connection 4-pole terminal for 12.5mm2, torque 0.8Nm max.
Mounting Clip for 35mm DIN rail, EN60715
Casing Plastic according to UL94 V-0, light grey
Dimensions 47x63x33mm
Weight Approx. 40g
Fitting position Variable
Op/storage temp. -20 to +80°C / -45 to +80°C
Protection type IP20
Approvals VDE + UL File No. E164102
Thermostat
FTD 011
Example of connection
44
Mechanical
Thermostat - FZK 011
• Adjustable temperature
• High switching capacity
• Small hysteresis
• Terminals easily accessible
• Clip fixing
• Change-over contact
The mechanical thermostat is used for controlling heating and cooling equip-
ment, filter fans or signal devices. The thermostat registers the surrounding
air and can switch both inductive and resistive loads via snap-action contact.
Technical Data:
Switch temperature difference 4K (±1.5K tolerance)*
Sensor element Thermostatic bimetal
Contact type Change-over snap-action contact
Contact resistance <10mΩ
Service life >100,000 cycles
Max. switching capacity, NC 250VAC, 10 (4) A
120VAC, 10 (4) A
DC 30W
Max. switching capacity, NO 250VAC, 5 (2) A
120VAC, 5 (2) A
DC 30W
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3
Connection 4-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715
Casing Plastic according to UL94 V-0, light grey Connection diagram
Dimensions 67x50x38mm
Weight Approx. 0.1kg
Fitting position Variable Enclosure heater
Op/storage temp. -20 to +80°C / -45 to +80°C
Protection type IP20
Approvals UL File No. E164102 Filter fan,
*Connecting terminal “N” (RF heating resistor) causes the thermal feedback to work and so reduces the switch Cooling equipment,
temperature difference to approx. 0.5K. Signal device
Examples of connection
Art. No. Operating voltage Setting range
230VAC +5 to +60°C
230VAC +40 to +140°F
230VAC -20 to +30°C
120VAC +40 to +140°F
120VAC +5 to +60°C
45
(24VDC)
Electronic
Thermostat - ET 011
• High DC breaking capacity
• Low hysteresis
• Adjustable temperature
• Change-over contact
• Clip fixing
Technical Data:
Switch temperature difference Approx. 3K
Sensor element PTC
Contact type Change-over
Contact resistance <10mΩ
Service life >100,000 cycles
Max. switching capacity 28VDC, 16A
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3
Connection 5-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715
Casing Plastic according to UL94 V-0, light grey
Dimensions 67x50x46mm
Weight Approx. 80g
Fitting position Vertical
Op/storage temp. 0 to +60°C / -45 to +80°C
Protection type IP20
Approvals -
Connection diagram
Examples of connection
46
Ex FixTherm96 Thermostat
The Ex FixTherm96-Thermostats are often used as maximum thermo-
stat in instrumentation cabinets with
• Prevention of overheating
• Temperature controlling
Technical Data:
Housing Anodized aluminium or stainless steel
Current / voltage 6A / 240 VAC
Cable 3x 0,75 sqmm
Material cable silicone braided cable, optional: non-braided cable
Standard length Approx. 1 mtr
Other lengths On request
Overall dimensions o.d. 30mm x 49mm length
Weight Approx. 160g
Switch SPST
Set-point tolerance +/-3ºC
Hysteresis Approx. 2ºC
Mounting bracket avaliable (B)
Ambient temp. range -50ºC...+90ºC
EX protection class II 2G Ex d IIC T6 or T4
II 2D Ex tD A21 IP66T
T 85ºC orT 135ºC
Certification KEMA 01ATEX2125X and IECEx DEK 11.0017
Description
The housing is made from anodized Aluminium or Stainless Steel type 316 (on request).
When required in other applications, e.g. analyzers, it is normal practice to use our Space-heaters in combination with
these Fix-Therm96 thermostats (range from 10°C up to 135°C). The FixTherm96 can also be used for cooling purpo-
ses e.g. FixTherm TH-10/5F.
Range
Aluminium: TH-10/5 – going up with 5°C setpoints e.g. 10/5“ 15/10“ 20/15 etc. up to 135°C maximum.
47
Electrical Thermostat
Ex FixTherm96 General Purpose
SAN-GTH*/*
For Non-Hazardous areas the General Purpose FixTherm96
thermostats are very suitable. Often used as maximum ther-
mostat in instrumentation cabinets with space heating, to
protect the equipment from overheating. Or as a minimum
thermostat with space heating to protect from freezing.
Technical Data:
Housing Anodized aluminium
Current / voltage 6A / 240 VAC
Cable 3x 0,75 sqmm
Material cable Non-braided silicone cable
Standard length Approx. 1 mtr, other lengths optional
Overall dimensions 30mm x 58mm (diameter xH)
Weight Approx. 160g
Switch SPST
Set-point tolerance +/-3ºC
Hysteresis Approx. 2ºC
Mounting bracket avaliable (B)
protection IP66
Description
The housing is made from anodized aluminium. When required in other applications, e.g. analyzers, it is normal prac-
tice to use our Space-heaters in combination with our Fix-Therm96 thermostats (range from 10°C up to 130°C). The
FixTherm96 can also be used for cooling purposes e.g. FixTherm96 TH-10/5F (N.O. contact).
Range
GTH-10/5 - going up with 5°C each time e.g. 10/5 - 15/10 - 20-15 etc. up to 130°C maximum.
48
Mechanical
Hygrostat - MFR 012
Technical Data:
Switch difference* 4% RH (±3% tolerance)
Permissible air velocity 15m/sec
Contact type Change-over contact
Contact resistance <10mΩ
Service life >100,000 cycles
Min. switching capacity 20V AC/DC, 100mA
Max. switching capacity 250VAC, 5 (1) A
DC 20W
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3
Connection 3-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715
Casing Plastic according to UL94 V-0, light grey
Dimensions 67x50x38mm
Weight Approx. 60g
Fitting position Variable
Op/storage temp. 0 to +60°C / -20 to +80°C
Protection type IP20
Approvals UL File No. E164102
Filter fan,
Cooling equipment,
Signal device
Connection diagram
Examples of connection
49
Electronic
Hygrostat - EFR 012
Technical Data:
Switch difference 5% RH (±1% RH tolerance) at 25°C (50% RH)
Reaction time Approx. 5 sec.
Contact type Change-over contact (relay)
Service life >50,000 cycles
Max. switching capacity (relay 240VAC, 8 (1.6) A
output) 120VAC, 8 (1.6) A
24VDC, 4A
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3
Optical indicator LED
Connection 5-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715
Casing Plastic according to UL94 V-0, light grey
Dimensions 64.5x42x38mm
Weight Approx. 70g
Fitting position Vertical
Op/storage temp. 0 to +60°C / -20 to +70°C
Max storage humidity 90% RH (without condensation)
Protection type IP20
Hygrostat Heater
EFR 012
4
Heater
Connection diagram
Example of connection
50
Electronic
Hygrotherm - ETF 012
Technical Data:
Switch difference (temperature) 2K (±1K tolerance) at 25°C (50% RH)
Switch difference (humidity) 4% RH (±1% tolerance) at 25°C (50% RH)
Reaction time (humidity) Approx. 5 sec.
Contact type Change-over contact (relay)
Contact resistance <10mΩ
Service life NC >50,000 cycles
NO >100,000 cycles
Max. switching capacity (Relay NC 240VAC, 6 (1) A
out-put) NO 240VAC, 8 (1.6) A
NC 120VAC, 6 (1) A
NO 120VAC, 8 (1.6) A
24VDC, 4A
EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3
Optical indicator LED
Connection 5-pole terminal, clamping torque 0.5Nm max.:
rigid wire 2.5mm2
stranded wire (with wire end ferrule) 1.5mm2
Mounting Clip for 35mm DIN rail, EN60715
Casing Plastic according to UL94 V-0, light grey
Dimensions 77x60x43mm
Weight Approx. 0.2kg
Fitting position Vertical
Op/storage temp. 0 to +60°C / -20 to +80°C
Protection type IP20
Hygrotherm Heater
ETF 012
Connection diagram
Example of connection
Art. No. Operating volt- Setting range Setting range humidity Approval
age temperature
230VAC, 50/60Hz 0 to +60°C 50 to 90% RH VDE + UL FIle No. E164102
120VAC, 50/60Hz +32 to +140°F 50 to 90% RH UL File No. E164102
120VAC, 50/60Hz 0 to +60°C 50 to 90% RH UL File No. E164102
51
15°C, 25°C
Hazardous area
Thermostat - REx 011 Series
• Compact design
• Set temperature
• High switching capacity
Technical Data:
Explosion proof acc. to EN LCIE (Laboratoire Central des Industries Electriques)
Conformity certificate 01 ATEX 6074/02, LCIE Nº 06 ATEX 08011, IECEx LCI 07. 0021
Sensor element Thermostatic bimetal
Contact type (1-pole) Opens with rising temperature
Service life >100,000 cycles
Max. switching capacity 250VAC, 4 (1) A
Connection Si HF - JZ 3x0.75mm2, length 1m
Mounting mounting bracket with nut M8 (see illustration)
Casing Aluminium, black anodised
Dimensions length 110mm
Weight Approx. 0.2kg
Fitting position Variable
Op/storage temp. -20 to +40°C / -45 to +70°C
Prot. type/ Prot. class IP65 / I (earthed)
Aluminium
Mounting Bracket
52
with on/off switch
Slimline
Lamp - SL 025 Series
• Slim casing
• Electronic ballast
• Lamp without/with electrical socket (choice of sockets)
The flat slimline lamp SL 025 is suitable for all types of panels and enclo-
sures, especially where space is at a premium. The lamp can be mounted on
its narrow or broad surface using screws. It is also available with a magnet
which allows it to be fitted quickly in any position in a steel enclosure. Both
versions are available with an integrated electrical socket enabling the use of
additional appliances.
Technical Data:
Power consumption 11W (equals 75W light bulb)
Luminosity 900Lm
Lamp type Energy saving lamp, 2G7 socket
Service life 10,000h
Switch On/off light switch
Connection Terminal 2.5mm2 with cable clamp, torque 0.8Nm max.
Mounting Screw fixing, M5, 300mm centers
magnet fixing (optional)
Casing Plastic acc. to UL94 V-0, light grey
Dimensions 345x91x40mm
Fitting position Narrow surface/broad surface
Op/storage temp. -20 to +50°C / -45 to +75°C
Protection type IP20
Note The slimline lamp SL 025 is also available with a 19” front panel
24VDC to 48VDC on request
Art. No. Model Operating volt- Socket Nominal Current Weight Protection class Approvals
age (approx)
without magnet 230VAC, 50/60Hz Germany/Russia (1) 16.0A 0.4kg I (earthed) VDE
with magnet 230VAC, 50/60Hz Germany/Russia (1) 16.0A 0.5kg I (earthed) VDE
without magnet 230VAC, 50/60Hz F/PL/CZ/SK (2) 16.0A 0.4kg I (earthed) VDE
with magnet 230VAC, 50/60Hz F/PL/CZ/SK (2) 16.0A 0.5kg I (earthed) VDE
without magnet 230VAC, 50/60Hz Switzerland (3) 10.0A 0.4kg I (earthed) VDE
with magnet 230VAC, 50/60Hz Switzerland (3) 10.0A 0.5kg I (earthed) VDE
without magnet 230VAC, 50/60Hz UK/Ireland (4) 13.0A 0.4kg I (earthed) VDE
with magnet 230VAC, 50/60Hz UK/Ireland (4) 13.0A 0.5kg I (earthed) VDE
without magnet 120VAC, 50/60Hz USA/Canada (5) 15.0A 0.4kg I (earthed) UL File No. E234324
with magnet 120VAC, 50/60Hz USA/Canada (5) 15.0A 0.5kg I (earthed) UL File No. E234324
without magnet 230VAC, 50/60Hz none - 0.4kg II (double insulated) VDE + UL File No. E234324
with magnet 230VAC, 50/60Hz none - 0.5kg II (double insulated) VDE
without magnet 120VAC, 50/60Hz none - 0.4kg II (double insulated) UL File No. E234324
with magnet 120VAC, 50/60 Hz none - 0.5kg II (double insulated) UL File No. E234324
53
with movement sensor
Slimline
Lamp - SL 025 Series
• Slim casing
• Electronic ballast
The flat slimline lamp SL 025 with movement sensor is suitable for all types
of panels and enclosures, especially where space is at a premium. The
lamp can be mounted on its narrow or broad surface using screws. It is also
available with a magnet which allows it to be fitted quickly in any position
in a steel enclosure. Both versions are available with an integrated electri-
cal socket enabling the use of additional appliances. The movement sensor
substitutes a door contact switch.
Technical Data:
Power consumption 11W (equals 75W ligth bulb)
Luminosity 900Lm
Lamp type Energy saving lamp, 2G7 socket
Service life 10,000h
Swittch PIR movement sensor, approx. 6min. fixed switch-on duration
Connection Terminal 2.5mm2 with cable clamp, torque 0.8Nm max.
Mounting Screw fixing, M5, 300mm centers
magnet fixing (optional)
Casing Plastic acc. to UL94 V-0, light grey
Dimensions 345x91x40mm
Fitting position Narrow surface/broad surface
Op/storage temp. 20 to +50°C / -45 to +70°C
Protection type IP20
Note The slimliine lamp SL 025 is also available with a 19” front panel
24VDC to 48VDC on request
The PIR movement sensor switches the lighting on when the enclosure door is opened. The switch-on timne is
reset with every further registered movement. The movement sensor does not react to mevement on the other side
of glass and so can be used in enclosures with glass doors.
Art. No. Model Operating volt- Socket Nominal Current Weight Protection class Approvals
age (approx)
without magnet 230VAC, 50/60Hz Germany/Russia (1) 16.0A 0.4kg I (earthed) VDE
with magnet 230VAC, 50/60Hz Germany/Russia (1) 16.0A 0.5kg I (earthed) VDE
without magnet 230VAC, 50/60Hz F/PL/CZ/SK (2) 16.0A 0.4kg I (earthed) VDE
with magnet 230VAC, 50/60Hz F/PL/CZ/SK (2) 16.0A 0.5kg I (earthed) VDE
without magnet 230VAC, 50/60Hz Switzerland (3) 10.0A 0.4kg I (earthed) VDE
with magnet 230VAC, 50/60Hz Switzerland (3) 10.0A 0.5kg I (earthed) VDE
without magnet 230VAC, 50/60Hz UK/Ireland (4) 13.0A 0.4kg I (earthed) VDE
with magnet 230VAC, 50/60Hz UK/Ireland (4) 13.0A 0.5kg I (earthed) VDE
without magnet 120VAC, 50/60Hz USA/Canada (5) 15.0A 0.4kg I (earthed) UL File No. E234324
with magnet 120VAC, 50/60Hz USA/Canada (5) 15.0A 0.5kg I (earthed) UL File No. E234324
without magnet 230VAC, 50/60Hz none - 0.4kg II (double insulated) VDE + UL File No. E234324
with magnet 230VAC, 50/60Hz none - 0.5kg II (double insulated) VDE
without magnet 120VAC, 50/60Hz none - 0.4kg II (double insulated) UL File No. E234324
with magnet 120VAC, 50/60 Hz none - 0.5kg II (double insulated) UL File No. E234324
54
On/off switch
Dual Lamp - DL 026 Series
55
Movement sensor
Dual Lamp - DL 026 Series
Technical Data:
Luminosity 1000Lm
Lamp type Energy saving lamp, E27 socket
Service life 10,000h
Switch PIR movement sensor, approx. 3min. fixed switch-on duration
Connection 4-pole screw connector 2.5mm2 (torque 0.5Nm max.) for power connection
and further lamps
Mounting Screw fixing, (e.g. 35mm DIN rail)
Casing Plastic acc. to UL94 V-0, light grey
Weight Approx. 0.6kg
Fitting position Variable
Op/storage temp. -20 to +50°C / -45 to +70°C
Prot. type/prot. class IP20 / II (double insulated)
Approvals -
Accessories Wall holder with connection cable (2m), hook and fixing plate
Note 120VAC and DC voltages on request
The PIR movement sensor switches the lamp on when the enclosure door is opened. The switch-on time is reset
with every further registered movement. The movement sensor does not react to mevement on the other side of
glass and so can be used in enclosures with glass doors.
56
With lamp holder
Hand Lamp - DL 026 Series
Technical Data:
Luminosity 1000Lm
Lamp type Energy saving lamp, E27 socket
Service life 10,000h
Connection Power cable (2m) with Euro plug
Mounting Screw or fixing plate (self-adhesive)
Casing Plastic acc. to UL94 V-0, light grey
Weight Approx. 0.6kg
Fitting position Variable
Op/storage temp. -20 to +50°C / -45 to +70°C
Prot. type/prot. class IP20 / II (double insulated)
Approvals -
Accessories Lamp holder, hook and fixing plate
Note 120VAC and DC voltages on request
57
Compact
Lamp - KL 025 Series
Technical Data:
Luminosity 900Lm
Lamp type Compact fluorescent lamp with integral starter
Service life 5,000h
Switch On/off light switch
Connection 3-pole terminal 2.5mm2 with cable clamp, torque 0.8Nm max.
Mounting Magnet fixing
Casing Plastic, light grey
Dimensions 355x65x70mm
Weight Approx. 1kg
Fitting position Variable
Op/storage temp. -20 to +50°C / -45 to +70°C
Protection type IP20
Accessories Lamp cover, Art. No. (see photo)
Magnet
In plastic, aluminium or stainless steel cabinets the lamp can be fixed using
screws together with inserted 35mm DIN rail sections.
Art. No. Operating voltage Socket Power consumption Nominal Current Protection class Approvals
230VAC, 50Hz Germany/Russia (1) 11W (equals 75W light bulb) 16.0A I (earthed) VDE
230VAC, 50Hz none 11W (equals 75W light bulb) - II (double insulated) -
230VAC, 50Hz F/PL/CZ/SK (2) 11W (equals 75W light bulb) 16.0A I (earthed) -
230VAC, 50Hz Switzerland (3) 11W (equals 75W light bulb) 10.0A I (earthed) -
230VAC, 50Hz UK/Ireland (4) 11W (equals 75W light bulb) 13.0A I (earthed) -
230VAC, 50Hz Italy (6) 11W (equals 75W light bulb) 16.0A I (earthed) -
120VAC, 60Hz USA/Canada (5) 9W (equals 60W light bulb) 15.0A I (earthed) -
120VAC, 60Hz none 9W (equals 60W light bulb) - II (double insulated) -
58
Electrical
Socket - SD 035 Series
• Quickly connected
• Available with or without fuse
• Clip fixing
The DIN rail mounted electrical socket can be quickly fitted and connected in
enclosures allowing the use of auxiliary products such as hand lamps, mea-
suring devices, soldering irons etc. The unit is available with and without fuse
and in many world socket standards.
Technical Data:
Connection 3 x pressure clamps for stranded and rigid wire 0.5 - 2.5mm2
Mounting Clip for 35mm DIN rail, EN60715
Casing Plastic acc. to UL94 V-0, light grey
Dimensions 92 x 62 x 48mm
Weight Approx. 0.2kg
Fitting position Variable
Op/storage temp. -45 to +70°C
Prot. type/prot. class IP20 / I (earthed)
59
IP45/IP55
Pressure compensation
Device - DA 084
• High degree of protection
• Easy to install
Technical Data:
Mounting PG29 thread with union nut
Material Plastic acc. to UL94 V-0
Photo: Inside view
Air interface Approx. 7cm2
Dimensions Ø65.5x30.5mm
Fitting position Variable
Op/storage temp. -45 to +70°C
Installation:
Make cut-out Ø37+¹mm in enclosure wall and mount pressure compensation device with nut. Please make sure
that the sealing gasket is put in place on the outer side panel of the enclosure. For optimal pressure compensation
we recommend to use two devices on opposite sides towards the top of the enclosure.
60
IP66
Pressure compensation
Device - DA 284
• High degree of protection
• Semipermeable membrane
• Easy to install
Technical Data:
Mounting Thread M40 x 1.5 with nut Photo: Inside view
Depth in enclosure Approx. 16mm
Material Plastic, light grey
Sealing Sealing gasket NBR
Filter Semipermeable membrane
Air permeability 1200 l/h at a pressure difference of min. 70mbar
Dimensions Ø60x37mm
Fitting position Variable
Op/storage temp. -45 to +70°C
Installation:
Make cut-out Ø40.5+0.5mm in enclosure wall and mount pressure compensation device
with nut. Please make sure that the sealing gasket is put in place on the outer side panel
of the enclosure. For optimal pressure compensation we recommend to use two devices
on opposite sides towards the top of the enclosure.
61
IP66
Pressure compensation
Device - DA 284
• High degree of protection
• Semipermeable membrane
• Corrosion resistant
• Food safe
Installation:
Make cut-out Ø40.5+0.5mm in enclosure wall and mount pressure compensation device with nut. Please make sure
that the sealing gasket is put in place on the outer side panel of the enclosure. For optimal pressure compensation
we recommend to use two devices on opposite sides towards the top of the enclosure.
62
Self-adhesive
Sanofix - Appliance Holder
Sanofix is an appliance holder for direct fixing of small appliances and perfo-
rated 35mm DIN rails.
Technical Data:
Load 500g 24h waiting period*
Mounting Self-adhesive (non-ageing, high-performance adhesive band)
Material Plastic acc. to. UL94 V-0
Dimensions 43x38x14mm
Screw pitch 12.8mm; Ø3.6mm, for perforated 35mm DIN rail
Op./storage temperature -45 to 70˚C
*Depending on the conditions of use (e.g. surface condition, size of the device to be mounted, etc.) higher loads
are possible.
Installation:
Sanofix can only be mounted on smooth surfaces, e.g. metals, lacquered surfaces and plastics (except poly-
ethylene, polypropylene and rubber). The surfaces must be dry, free from dust, oil, separating agents and other
contamination.
63
Calculation of temperature
control in enclosures
What’s needed:
1. The dimensions of the enclosure (height, width, depth) (m)
2. The enclosure position (e.g. single enclosure, enclosure in row) according to calculation formula, enclosure surface area A (m²)
3. The enclosure material (metal, plastic) heat transfer coefficient from table, k (W/m² K)
4. The temperature difference between desired enclosure interior temperature Ti (°C) and the expected ambient temperature Tu (°C)
(e.g. day - night, summer - winter, climate zones) ∆T (K=Kelvin)
5. The stray power (self-warming) of all installed components during operation (e.g. transformers, relays, semiconductors) PV (W)
Calculation and selection of parameters: enclosure surface area - heat transfer coefficient - temperature difference
Example.: Enclosure free on all sides, 2000mm high / 800mm wide / 600mm deep. A = 1.8 x 2.0 x (0.8 + 0.6) + 1.4 x 0.8 x 0.6 = 5.712m²
3. Enclosure material and its heat transfer coefficient k (W/m² K) 4. Temperature difference ∆T (K=Kelvin)
Steel sheet, painted k~5.5W/m² K ∆T = Ti - Tu
Steel sheet, stainless k~4.5W/m² K
Aluminium k~12W/m² K i.e. the temperature difference between interior and exterior
Aluminium, double-walled k~4.5W/m² K temperatures.
Polyester k~3.5W/m² K
Temperature difference ∆T
W
Varmeydelse W
Heating performance
Required air volume V (8m³/h) = installed stray power Pv(W) x air constant f* (3.3m³K/Wh)
temperature difference ∆T (K)
AirLuftmængde
Volume (m³/h)
(m3/time)
64
65
Member of the NIBE Group
• Process Heating
• Heating Elements
• Heating Cables
• Finned Tubular
Radiators
• Immersion Heaters
• Church Heating
• Frost Protection
• Ex-Material
• Oilfilled Radiators
• Drum Heaters
• Heating Pads
• Flow Heaters
• Air Duct Heaters
• High-voltage
• Resistors
• Controllers
With more than 50 years of experience SAN Electro Heat’s most valu-
able asset is special knowhow about design, product development and
manufacturing of professional electrical
heating equipment for industrial use.
www.san-as.com