Sunteți pe pagina 1din 2

Supreme 10HT Technical Data Sheet

Supreme 10HT
One component, toughened epoxy system
Master Bond
Polymer System

Key Features
33 No mix, single component system 33 Resistance to mechanical and thermal shocks
33 Serviceability from 4K to +400°F 33 NASA low outgassing approved
33 Unlimited working life at room temperature 33 Withstands 1,000 hours 85°C/85% RH

Product Description high, although it has a small amount of flow when initially
cured. A non-flow version called Supreme 10HTND-2 is also
Master Bond Supreme 10HT features a unique blend of
available. Supreme 10HT’s high performance properties
performance properties including both high shear and
coupled with its convenient handling make it widely used
peel strengths along with convenient handling. Tensile
in a variety of applications in the aerospace, electronic,
shear strengths in excess of 3,600 psi and T-peel strengths
electrical, computer, metalworking, appliance, automotive
up to 30 pli are readily obtained. This one component
and chemical industries. Most importantly, Supreme 10HT
system is formulated to cure at elevated temperatures, e.g.
has been tested for, and meets NASA low outgassing
60-75 minutes at 250°F. Supreme 10HT has a number of
specifications.
outstanding processing advantages; no mixing is necessary
prior to use, the viscosity remains constant with time (i.e. Product Advantages
it will not thicken over time), the working life is unlimited
ƒƒ High shear and peel strengths to a wide variety of
at room temperature and it is room temperature storable.
similar and dissimilar substrates
This epoxy is cryogenically serviceable and has a wide
temperature range of 4K to +400°F. ƒƒ Cryogenically serviceable

Master Bond Supreme 10HT readily withstands severe ƒƒ Superior thermal cycling ability
thermal cycling along with mechanical shock and vibration. ƒƒ Unlimited working life at room temperature
It is very resistant to many chemicals including water, oils, ƒƒ Versatile cure schedules: 60-75 minutes at 250°F;
fuels, solvents, acids and bases. It has excellent adhesion 35-40 minutes at 300°F
to metals, glass, ceramics and many plastics. The cured
ƒƒ 100% reactive; contains no solvents or diluents
epoxy is a superior electrical insulator. Its natural color is
gray, but other colors are available. Its viscosity is very ƒƒ Outstanding durability and toughness

Typical Properties
Tensile lap shear strength, aluminum to aluminum, 75°F 3,600-3,800 psi
Tensile strength, 75°F 8,000-9,000 psi
Tensile modulus, 75°F 450,000-500,000 psi
Compressive strength, 75°F 14,000-16,000 psi
T-peel strength, 75°F 25-30 pli
Elongation, 75°F 5-10%
Hardness, 75°F 70-80 Shore D
Hardness after 1,000 hours 85°C/85% RH 80 Shore D
Volume resistivity, 75°F >1012 ohm-cm
Service temperature range 4K to +400°F [4K to +204°C]

Master Bond Inc. | Tel: +1 (201) 343-8983 | www.masterbond.com | techinfo@masterbond.com 1


Supreme 10HT Technical Data Sheet

Mixing and Curing


Shelf life at 75°F, in original unopened containers 3 months minimum, 6 months maximum
Viscosity, 75°F >500,000 cps
Cure schedule options
250°F 60-75 minutes
300°F 35-40 minutes

Preparation of Adhesive Packaging


Master Bond Polymer System Supreme 10HT does not Packaging available in:
require any mixing prior to use. Some simple stirring ƒƒ 1/2 Pint
is recommended if the adhesive has been stored for a ƒƒ Pint
prolonged period of time without use (this could be ƒƒ Quart
facilitated by heating the product from 90-110°F). Such ƒƒ Gallon
stirring should be done slowly to avoid entrapping air. Using
ƒƒ 5 Gallon
the adhesive is easy. Simply apply the measured adhesive
Available in specialty packaging including
on the surface to be bonded evenly and uniformly.
cartridges and syringes.

Preparation of Bonding Surfaces


Handling and Storage
All bonding surfaces should be carefully cleaned, degreased
All epoxy resins should be used with good ventilation and
and dried for obtaining the maximum bond strengths.
skin contact should be avoided. For safe handling details,
Also when bonding to metal surfaces, chemical etching
should be employed so that the bonds exhibit optimum please consult the product SDS. Optimum storage is at
environmental durability. Non-porous surfaces should be or below 75°F in closed containers. No special storage
conditions are necessary. Containers should, however,
roughened with sandpaper or emery paper.
be kept closed when not in use to avoid contamination.
Cleanup of spills and equipment is readily achieved with
Adhesive Application
aromatic or ketone solvents employing proper precautions
Supreme 10HT can be conveniently applied with a spatula, of ventilation and flammability.
knife or trowel. Enough adhesive should be applied to
obtain an adhesive bond line thickness of 3-6 mils. Porous
Certifications
surfaces may require somewhat more adhesive to fill the
voids than non-porous ones. Thicker glue lines do not
increase the strength of a joint but do not necessarily give
Low Outgassing
RoHS
COMPLIANT
lower results as the Supreme 10HT system does not contain
any volatiles. The parts to be bonded should then be
clamped together with just enough pressure to obtain and Not to Be Used for Specification Purposes
maintain intimate contact during cure. Care should be taken The values contained herein are considered typical
not to squeeze out the adhesive when fixturing. Since the properties only and are not intended to be used
system is 100% reactive and does not contain any solvents as specification limits. For assistance in preparing
or diluents shrinkage on cure is minimal. specifications, please contact Master Bond technical
support for further details.
Cure
Supreme 10HT requires an elevated temperature cure. Notice
The minimum curing condition is 60-75 minutes at 250°F. Master Bond believes the information on the data sheets
Remove excess adhesive promptly before it hardens with a is reliable and accurate as is technical advice provided by
spatula. Then wipe with a rag and solvent, such as acetone, the company. Master Bond makes no warranties, expressed
toluene or MEK. It is important to note that Supreme 10HT or implied, regarding the accuracy of the information, and
is exothermic and when curing the epoxy—particularly at assumes no liability regarding the handling and use of this
300°F, sections should not exceed 10-15 mils. product.
F23C16

Master Bond Inc. | Tel: +1 (201) 343-8983 | www.masterbond.com | techinfo@masterbond.com 2

S-ar putea să vă placă și