“ A COMPLETE WATER STORAGE SOLUTION “


Pure Drinking
Water Tank

BS 6920 : 2000
Approved by Water Regulations
Advisory Scheme
KPIC - POLYETHYLENE
WATER TANK
Manufactured to the best quality with COMPONENTS
less maintenance. Our tanks are de-
signed to protect against mold, micro- LLDPE : Copolymer is designed to provide excellent
organisms, bacterias, fungi & algae. stress crack resistance, high rigidity, toughness, gloss
Produced from non toxic material and and very low warpage. The resin contains UV stabilizer.
approved for storage and handling po-
table water as well as Insulated from
external heat.

ADVANTAGES
• Corrosion Free
• Easy handling and installation
• Proven resistance to acidic environ-
ment in water system
• Low maintenance cost
• Low transport cost
• Weight Advantages
• Portable
• Flexibility

APPLICATIONS
• Drinking Water tank
• Septic tank
• Sewage Water tank
• Potable Water tank
• Irrigation water tank

ROTOMOULD (POLYETHYLENE)
WATER TANKS
• Vertical Polyethylene Water tanks
• Horizontal Polyethylene Water tanks
• Rectangular Polyethylene Water tanks

BS 6920 : 2000
Approved by Water Regulations
Advisory Scheme Eco
Friendly
Recyclable
Products
Ozone
VERTICAL
WATER TANK
DIMENSION OF VERTICAL TANKS
CAPACITY DIA HEIGHT THICKNESS
100 GALLON 830 MM 1050 MM 16 MM
200 GALLON 1020 MM 1260 MM 16 MM
250 GALLON 1100 MM 1270 MM 16 MM
300 GALLON 1170 MM 1430 MM 18 MM
400 GALLON 1270 MM 1580 MM 18 MM
500 GALLON 1310 MM 1790 MM 18 MM
600 GALLON 1440 MM 1790 MM 18 MM
800 GALLON 1590 MM 1900 MM 18 MM
1000 GALLON 1700 MM 2030 MM 19 MM
1000 GALLON (S.H) 2400 MM 1200 MM 20 MM
1200 GALLON 1750 MM 2070 MM 20 MM
1500 GALLON 1940 MM 2340 MM 20 MM
2000 GALLON 2170 MM 2570 MM 21 MM
2500 GALLON 2320 MM 2620 MM 22 MM
3000 GALLON 2420 MM 2770 MM 23 MM
5000 GALLON 2830 MM 3380 MM 25 MM

SPECIFICATION BILL OF MATERIALS


ITEM DESCRIPTION ITEM DESCRIPTION QTY
Skin Thickness Up to 10 mm 1 Manhole cover 1
No. of Chambers One 2 Air vent 1
Manhole Diameter up to 500
Inlet Connection up to 6 inch dia uPVC Pipe
Outlet Connection up to 6 inch dia uPVC Pipe
Air Vent up to 20 mm height and 30 mm dia
Layers Properties 3 layers (White, Black, White)

Connection point
500

200

15mm Thickness
TOP VIEW

Air vent Detail


Height 20 mm
200 Dia 50 mm

FRONT VIEW TOP VIEW


WATER TANK
DRAWING
HORIZONTAL
WATER TANK

DIMENSION OF HORIZONTAL TANKS


CAPACITY LENGTH HEIGHT THICKNESS
100 GALLON 1050 MM 790 MM 16 MM
150 GALLON 1180 MM 780 MM 16 MM
200 GALLON 1290 MM 885 MM 16 MM
250 GALLON 1380 MM 920 MM 18 MM
400 GALLON 1690 MM 1130 MM 18 MM
500 GALLON 1810 MM 1180 MM 18 MM
600 GALLON 2010 MM 1330 MM 18 MM
800 GALLON 2100 MM 1390 MM 18 MM
1000 GALLON 2330 MM 1550 MM 19 MM

SPECIFICATION BILL OF MATERIALS


ITEM DESCRIPTION ITEM DESCRIPTION QTY
Skin Thickness Up to 10 mm 1 Manhole cover 1
No. of Chambers One 2 Air vent 1
Manhole Diameter up to 500
Inlet Connection up to 6 inch dia uPVC Pipe
Outlet Connection up to 6 inch dia uPVC Pipe
Air Vent up to 20 mm height and 30 mm dia
Layers Properties 3 layers (White, Black, White)

2
RECTANGULAR
WATER TANK

DIMENSION OF RECTANGULAR TANKS


CAPACITY LENGTH WIDTH HEIGHT
100 GALLON 1300 MM 985 MM 390 MM
200 GALLON 1565 MM 1285 MM 430 MM
400 GALLON 2000 MM 1880 MM 490 MM
500 GALLON 2000 MM 2000 MM 500 MM

SPECIFICATION BILL OF MATERIALS


ITEM DESCRIPTION ITEM DESCRIPTION QTY
Skin Thickness Up to 10 mm 1 Manhole cover 1
No. of Chambers One 2 Air vent 1
Manhole Diameter up to 500
Inlet Connection up to 6 inch dia uPVC Pipe
Outlet Connection up to 6 inch dia uPVC Pipe
Air Vent up to 20 mm height and 30 mm dia
Layers Properties 3 layers (White, Black, White)

2
DELIVERY, HANDLING &
INSTALLATION
The KPIC range of polyethylene storage tanks When your tank is being unloaded, moved or in-
are manufactured in compliance to interna- stalled, damage to tank fittings must be avoided.
tional standards using only the highest quali- Do not allow the weight of the tank to rest on
ty materials, however improper handling and any of the fittings and do not roll the tank over
installation can cause damage to the tanks any of its fittings.
and their fittings.
Warranty may be void if there is a failure on Installation
handling & installation of the tanks.
To avoid problems , guidelines are provided It is very important that tanks are installed on a
for the customers compliance for delivery, smooth, firm surface that can fully support the
handling & installation. weight of the tank. In most all situations a rein-
forced concrete base is the best solution. Even
Delivery and Handling when a tank stand is used, the stand must be
mounted on a solid base.
Upon delivery, it is the customer’s responsi-
bility ity to safely unload the tank from the
delivery vehicle. Unless agreed prior to de-
livery, the standard delivery vehicles do not
have the facilities to unload your tank. Consider the location of the installation and be
sure that there is enough room to carry out any
Delivery is completed once the customer has
maintenance activities. Polyethylene tanks may
thoroughly inspected the item without any
contract or expand due to temperature chang-
defect. if any defect was found on the item ,
es, atmospheric conditions and the nature of the
customer should immediately report the case
contents.
for the company to resolve the problem in
quickest possible way.
The tank should be unloaded onto a smooth,
flat surface that is free from rocks and other
sharp objects that could cause damage. extra
attention must be given to damage caused by
fork lift truck blades. It is highly recommend-
ed that a mobile lifting equipment (crane, Work activities that will take place in the vicinity
forklift truck, etc.) is used to lift large tanks must be taken into consideration precaution any
from the lorry. measure to avoid accidental contact with the
tank. failure may be a result of impact especially
in cold conditions.

The tank is not designed to support the weight


of machinery or equipment. Do not mount items like
this on top of the tank or on its fittings.
If human access is necessary, great care should be
taken to avoid asphyxiation by inhaling of hazardous
vapor and fumes.

Tank Use

The tanks should only be used for what it was pur-


pose for designed. Do not apply contents under
pressure or create a vacuum unless the tank is spe-
cifically rated.

Make sure that the materials stored in the tank are


appropriate for the properties of the tank, fittings,
gaskets and accessories.

FOR MORE
INFORMATION
Give us a call
Tel no.: +97444367821
Email : info@kpic.qa
KHALID PLASTIC INDUSTRIES COMPLEX W.L.L
P.O.Box:1511, Doha,State of Qatar
E-Mail: info@tietan.com,info@kpic.qa Web: www.kpic.com
Khalid Khalid Tel no +974 44367821, Fax No : +974 44630754

S-ar putea să vă placă și