Documente Academic
Documente Profesional
Documente Cultură
N N
TECHNICAL MANUAL
CONTENTS
1. PERFORMANCE CHARACTERISTICS
2. MATERIAL CHARACTERISTICS
5. CAUTION ------------------------------------------------ 21
7. PACKAGE ------------------------------------------------ 25
APPENDIX
1. SPECIFICATIONS --------------------------------------------------------------- 29
2. DISCHARGE RATES IN AMPERE --------------------------------------------------------------- 47
3. DISCHARGE RATES IN WATTS --------------------------------------------------------------- 50
4. CURVES VOLTAGE OF “K” --------------------------------------------------------------- 53
5. MATERIAL SAFETY DATA SHEET (M.S.D.S) --------------------------------------------------------------- 59
6. I.A.T.A --------------------------------------------------------------- 61
7. ELECTROLYTE OF SULFURIC ACID IN THE SLA BATTERY --------------------------------------------- 62
4. BATTERY SELECTION CHARTS ----------------------------------------------- 63
2 OF 63
1. PERFORMANCE CHARACTERISTICS
- UNION BATTERY –
(DISCHARGE)
(CHARGE)
AT DISTANCE, LEAD OXIDE IN POSITIVE PLATES AND SPONGY LEAD IN NEGATIVE PLATES REACT WITH
SULFURIC ACID IN THE ELECTROLYTE AND GRADUALLY TRANSFORM INTO LEAD SULPHATE, DURING WHICH
THE SULFURIC ACID CONCENTRATION DECREASES.
CONVERSELY, WHEN THE BATTERY IS CHARGED, THE POSITIVE AND SULPHATE GRADUALLY REVERT TO LEAD
DIOXIDE AND SPONGY LEAD RESPECTIVELY. RELEASING THE SULPHURIC ACID ABSORBED IN THE ACTIVE
MATERIAL. DURING WHICH THE SULPHURIC ACID CONCENTRATION INCREASES, AS SHOWN IN FIGURE 1.
WHEN BATTERY CHARGING APPROACHES ITS FINAL STAGE. THE CHARGING CURRENT IS CONSUMED SOLELY
FOR ELECTROLYTE DECOMPOSITION OF WATER IN THE ELECTROLYTE, RESULTING IN GENERATION OF
OXYGEN GAS FROM POSITIVE PLATES AND HYDROGEN GAS FROM NEGATIVE PLATES. THE GENERATED GAS
WILL ESCAPE FROM THE BATTERY CAUSING A DECREASE OF THE ELECTROLYTE, THEREBY REQUIRING
OCCASIONAL WATER REPLENISHMENT.
HOWEVER, OUR BATTERIES UTILIZE THE CHARACTERISTICS OF SPONGY LEAD, OR NEGATIVE ACTIVE
MATERIAL, WHICH IS VERY ACTIVE IN MOIST CONDITIONS AND REACTS VERY QUICKLY WITH OXYGEN.
THEREBY SUPPRESSING THE DECREASE OF WATER ELIMINATING THE NEED OF WATER REPLENISHMENT.
THE PROCESS OF CHARGING FROM ITS BEGINNING TO THE FINAL STAGE IS IDENTICAL WITH THAT OF
CONVENTIONAL BATTERIES AS SHOWN IN FIGURE 1.
ON THE OTHER HAND, AFTER THE STAGE OF CHARGING OR UNDER OVERCHARGE CONDITION, THE CHARGING
ENERGY IS CONSUMED FOR ELECTROLYTIC DECOMPOSITION OF WATER, AND THE POSITIVE PLATES
GENERATE OXYGEN GAS WHICH REACTS WITH THE SPONGY LEAD IN NEGATIVE PLATES AND THE SULFURIC
ACID IN ELECTROLYTE, TURNING A PART OF NEGATIVE PLATES INTO A DISCHARGED CONDITION. THUS
SUPPRESSING THE HYDROGEN GAS GENERATION FROM NEGATIVE PLATES.
THE PART OF NEGATIVE PLATES, WHICH HAD TURNED TO DISCHARGED CONDITION THROUGH REACTION WITH
OXYGEN GAS, IS THEN REVERTED TO ORIGINAL SPONGY LEAD BY SUBSEQUENT CHARGING. THUS, A
NEGATIVE PLATE KEEP EQUILIBRIUM BETWEEN THE AMOUNT WHICH TURNS INTO SPONGY LEAD BY
CHARGING AND THE AMOUNT OF SPONGY LEAD WHICH TURNS INTO LEAD SULPHATE THROUGH ABSORBING
THE GAS GENERATED FROM POSITIVE PLATES, WHICH MAKES IT POSSIBLE FOR THE BATTERY TO BE OF A
SEALED TYPE.
THE CHEMICAL REACTION, WHICH TAKES PLACE AFTER THE FINAL STAGE, OF CHARGING OR UNDER
OVERCHARGE CONDITION IS AS SHOWN IN FIGURE 2.
3 OF 63
(FIGURE 1)
TO REACTION (a)
d) REACTION OF PbSO4
TO REACTION (b)
TO REACTION (a)
(FIGURE 2)
AS DESCRIBED ABOVE, THE OXYGEN GAS GENERATED FROM THE POSITIVE PLATES REACTS QUICKLY WITH THE ACTIVE
MATERIAL IN CHARGED CONDITION IN THE NEGATIVE PLATES AND RETURNS TO WATER CAUSING VERY LITTLE LOSS
THEREOF. THUS MAKING IT POSSIBLE TO BUILD THE BATTERY IN A SEALED CONSTRUCTION.
5 OF 63
CHARGING AT CONSTANT VOLTAGE CHARGING IS THE MOST SUITABLE AND COMMONLY USED FOR CHARGING
SEALED LEAD ACID BATTERIES. FIGURE SHOW THE CHARGING CHARACTERISTIC OF OUR BATTERIES WHEN
CHARGED BY CONSTANT VOLTAGE CHARGER AT 2.25 VOLT/CELL WHEN THE INITIAL CHARGING CURRENT IS
CONTROLLED AT 0.1CA.
THE CHARGE VOLTAGE OF THE BATTERY DECREASES WITH INCREASING TEMPERATURE AND INCREASES
WITH DECREASING TEMPERATURE.
ACCORDINGLY CHARGING WITH GIVEN VOLTAGE REQUIRE INCREASED CHARGING CURRENT WHEN
TEMPERATURE IS HIGH AND DECREASED CHARGING CURRENT AT LOWER TEMPERATURE. TEMPERATURE OF
5°C OR ABOVE 35°C.
HOWEVER, TEMPERATURE COMPENSATION OF CHARGE VOLTAGE IS NECESSARY.
TEMPERATURE (°C) 0 10 20 25 30 35
VOLTAGE/CELL 2.37 2.33 2.30 2.28 2.25 2.23
CHARGE CHARACTERISTICS
7 OF 63
THE CAPACITY OF A BATTERY (AH) IS REPRESENTED BY THE RESULT OF THE DISCHARGE CURRENT (A) AND DISCHARGE
TIME (H) UNTIL THE FINAL DISCHARGE VOLTAGE IS REACHED.
THE FIGURE OF CONSTANT CURRENT DISCHARGE PERFORMANCE RELATED TO A PARTICULAR END OF DISCHARGE
VOLTAGE LEVEL IN THE RANGE 1.60 VOLTS PER CELL THROUGH TO 1.75 VOLTS PER CELL.
§ THE AVAILABLE AMPERES (OR WATTS WHERE APPLICABLE) OUTPUT FOR EACH DURATION IS
DEPENDANT UPON THE END OF DISCHARGE VOLTAGE LEVEL CHOSEN.
INCREASE IN SPECIFIED END VOLTS WOULD INCREASE BATTERY SIZE REQUIRED. THE QUOTED
END OF DISCHARGE VOLTS LEVEL RELATES TO THE BATTERY TERMINAL VOLTAGE. HENCE.
§ VOLTAGE DROP DUE TO CABLE RESISTANCE BETWEEN BATTERY TERMINALS LOAD CIRCUIT NEEDS
TO BE ALLOWED FOR IN THE SYSTEM CALCULATION. PARTICULARLY WHERE A HIGH CURRENT
SHORT DURATION LOAD IS INVOLVED.
§ THE ABOVE FIGURE SHOWS AN EXAMPLE OF DISCHARGING CHARACTERISTIC FOR 0.05c ~ 3c.
C AS NOMINAL CAPACITY.
8 OF 63
THE CAPACITY OF A BATTERY IS SUBJECTED TO THE INFLUENCE OF AMBIENT TEMPERATURE AND THE
DISCHARGE RATE.
LOW TEMPERATURE (BELOW 5°F, -15°C) MAY REDUCE THE AVAILABLE CAPACITY, AND HIGH TEMPERATURE
(OVER 122°F, 50°C) MAY DAMAGE THE BATTERY.
THE BELOW FIGURE SHOWS AN EXAMPLE OF THE EFFECT OF TEMPERATURE ON CAPACITY FOR THE RANGE
OF (4°F ~ 104°F) -20°C ~ -50°C.
THE RATED CAPACITY FOR 20°C IS 100%.
9 OF 63
THE USE OF THE Pb-Ca BASED ALLOY GRID RESULT SIN A VERY LOW SELF-DISCHARGE RATE.
THE AVERAGE SELF-DISCHARGE RATE PER DAY. IF LEFT CHARGED FOR SIX NON-USE MONTHS IS ABOUT
0.1% - 0.2% (20°C).
THE BELOW FIGURE SHOWS AN EXAMPLE OF THE SELF-DISCHARGE RATE FOR AMBIENT TEMPERATURE. IF THE
BATTERY IS NOT USED FO RA LONG PERIOD OF TIME, RECHARGE IS AT LEAST ONCE EVERY SIX MONTH.
10 OF 63
§ CYCLIC USE
THE NUMBER OF CYCLES (CHARGE & DISCHARGE)DEPENDS ON THE DEPTH OF DISCHARGE. OPERATING
TEMPERATURE AND THE CHARGING METHOD. THE BELOW FIGURE SHOWS THE RELATIONSHIP BETWEEN
DEPTH OF DISCHARGE AND NUMBER OF CYCLES.
§ FLOATING USE
AS THE LIFE OF BATTERY FOR FLOATING APPLICATION IS GREATLY AFFECTED BY VOLTAGE. CARE MUST
ALSO BE EXERCISED TO MAINTAIN AN APPROPRIATE WORKING TEMPERATURE. BECAUSE IT GREATLY
AFFECTS THE LIFE OF THE BATTERY. THE BELOW FIGURES SHOW THE LIFE OF BATTERIES FOR FLOATING
APPLICATIONS.
11 OF 63
THE VALUE OF INTERNAL RESISTANCE IS IMPORTANT WHEN A BATTERY MUST PRODUCE A PEAK CURRENT (I.E FOR
SWITCH TRIPPING) AT THE END OF THE DISCHARGE PERIOD.
THE GRAPH OPPOSITE SHOWS RESISTANCE AS A PERCENTAGE OF FULLY CHARGED RESISTANCE VALUE, FOR VARIOUS
CHARGE STATES.
THE UNION BATTERY HAS ITS INTERNAL RESISTANCE SMALLEST WHEN IT IS CHARGED COMPLETELY. THE INTERNAL
RESISTANCE SLOWLY AS DISCHARGE PROGRESS, AND INCREASES RAPIDLY AT THE FINAL STAGE OF DISCHARGE. IT
WILL BE OBSERVED THAT THE INTERNAL RESISTANCE DECREASES SLOWLY WHEN THE DISCHARGE IS TERMINATED AS
IT HAS REACHED THE FINAL STAGE.
THE MINUTE QUANTITIES OF GASES WHICH ARE RELEASE FROM BATTERY WITH RECOMMENDED RATES OF CHARGE
AND OVERCHARGE WILL NORMALLY DISSIPATE RAPIDLY INTO THE ATMOSPHERE.
HYDROGEN GAS I S DIFFICULT OT CONTAIN IN ANYTHING BUT A METAL OR GLASS ENCLOSURE; I.E., IT CAN PERMEATE A
PLASTIC CONTAINER AT A RELATIVELY RAPID RATE. BECAUSE OF THE CHARACTERISTICS OF GASES AND THE RELATIVE
DIFFICULTY IN CONTAINING THEM. MOST APPLICATIONS WILL ALLOW FOR THEIR RELEASE INTO THE ATMOSPHERE.
2. MATERIAL CHARACTERISTICS
- UNION BATTERY
2.1 PLATE
The positive and negative plates are made of lead oxide pasted on grids of Pb – Ca alloy that can be recharge quickly.
PLATE
PARAMETER GRID
(ACTIVE MATERIAL)
Ca 0.1 ± 0.01 % -
Ag - Max. 0.002%
Cu - Max. 0.002%
As - Max. 0.002%
PURITY
Sb + Sn 0.45 ± 0.15 % (Sn only) Max. 0.005%
Zn - Max. 0.002%
Fe - Max. 0.002%
Bi - Max. 0.005%
A1 0.025 ± 0.005 % -
2.2 SEPARATOR
Absorptive Glass Mat (AGM) with high durability and thermos-ability is used for separators, which absorbs electrolyte and
retains excellent conductivity.
Characteristics:
Parameter Contents
Porosity >90%
Parameter Contents
Hardness 60 ± 5 IRHD
TYPE A B C
These are made for ABS720 Resin, a synthetic resin, which has a superior acid resistance and durability. The container and
cover are designed to be completely sealed to prevent any leakage of electrolyte and gas.
Characteristics:
Parameter Contents
2.5 TERMINAL
Characteristics:
Parameter Contents
2-6-1 CHARACTERISTICS
Sulfuric acid is used both as an ingredient in the paste and as an e lectrolyte. In each application, dilute sulfuric acid is
obtained by mixing concentrated sulfuric acid of 1.835 specific gravity with water to the strength required.
Sulfuric acid concentrations most frequently used in battery manufacturing correspond to a specific gravity range of 1.050 to
1.400.
Sulfuric acid should be of high purity. The presence of even very small amount of certain impurities can affect both the life and
capacity of the battery adversely.
NO ITEM SPECIFICATION
4. STORAGE SYSTEM
AFTER LONG TERM STORAGE, ALL BATTERIES DELIVER LESS THAN RATED CAPACITY ON FIRST
CYCLE. IN CYCLIC APPLICATION FULL CAPACITY WILL BE OBTAINED THROUGH SEVERAL
CHARGE/DISCHARGING CYCLES.
IN FLOATING APPLICATION, FULL CAPACITY WILL BE ACHIEVED IN 24 – 48 HOURS, WHEN CHARGED
AT 2.3V/CELL.
n REFRESH CHARGE
AS THE BATTERY LIFE IS GREATLY AFFECTED BY THE METHOD OF CHARGING ADOPTED, YOU MUST
CONSIDER THE BATTERY USAGE AS WELL AS THE CHARGING CHARACTERISTICS, AND ALSO YOU
MUST BE VERY ATTENTIVE IN SELECTING AN APPROPRIATE CHARGER.
THE FOLLOWING CONSTANT VOLTAGE CHARGER CIRCUITS PROVIDE CONSTANT VOLTAGE.
21 OF 63
5. CAUTION
§ HEAT KILLS BATTERIES. YOU MUST AVOID PLACING BATTERIES IN CLOSE PROXIMITY TO HEAT
SOURCES OF ANY KIND.
YOU WILL ENJOY LONGER SERVICE LIFE. IF BATTERIES ARE OPERATED IN AMBIENT TEMPERATURE
RANGE OF 20°C (68°F) TO 25°C (77°F)
§ SINCE THE BATTERIES MAY GENERATE IGNITABLE GAS, PLEASE DO NOT INSTALL THEM CLOSE TO
ANY ITEM THAT PRODUCES SPARKS.
§ AS THE BATTERY CONTAINERS AND COVERS ARE MADE OF ABS720 RESIN, PLACING BATTERIES IN
AN ATMOSPHERE OF, OR IN CONTACT WITH ORGANIC SOLVENTS OR ADHESIVE MATERIAL SHOULD
BE AVOIDED.
§ USE SHOCK ABSORBER AND FASTEN BATTERY FIRMLY WHEN HEAVY VIBRATION OR EXPECTED
DURING SERVICE.
§ CLEAN THE BATTERY WITH A PIECE OF WET CLOTH. NEVER HAVE THE BATTERY SPLASHED OR
DEPOSITED WITH OILS OR ORGANIC SOLVENTS SUCH AS GASOLINE OR PAINT THINNER, NOR HAVE
IT CLEANED WITH CLOTHS IMPERMANENT WITH THESE MATERIALS.
6. USEFUL FORMULA
Example:
0.46 × 10 −3 ×120
x 1/6 = 0.00015 M3/Min
60
23 OF 63
V (Cell Voltage )
S.C.C (I) =
Ω( Internal Resistance of Battery )
Example:
12
= 2,666 A
0.0045Ω
24 OF 63
Example:
0.86 x (0.0003 x 18) x (13.5 – 10) + 0.07 x (0.0003 x 18) = 0.0166 Cal/Hr
25 OF 63
MX-12600 1 55 660
MX-12700 1 60 720
MX-121000 1 44 528
MX-122000 1 22 264
26OF 63
OUTSIDE USA
MODEL PCS / CARTON
PCS/PALLET PCS/CONTAINER
MX-12600 1 55 660
MX-12700 1 68 720
MX-121000 1 50 552
MX-122000 1 22 264
27 OF 63
APPENDIX
29 OF 63
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 6V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 6V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 6V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 6V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 6V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
20 HOURS RATE
I N D E X S P E C I F I C A T I O N
NOMINAL VOLTAGE 12 V
AFTER 1 MONTH 5%
SELF DISCHARGE (20°C, 68°C) AFTER 3 MONTH 10%
TERMINAL TYPE A
CONSTANT CURRENT
CONSTANT CURRENT
DISCHARGE RATES IN AMPERE AT 77°F (25°C)
AMPERES TO F.V 1.75 VOLTS PER CELL
TYPE
5 MIN 10 MIN 15 MIN 20 MIN 30 MIN 45 MIN 1 HR 3 HR 5 HR 10 HR 20 HR
MX-06012 4.650 2.815 1.973 1.606 1.202 0.847 0.704 0.291 0.203 0.111 0.060
MX-06040 15.499 9.384 6.576 5.352 4.008 2.825 2.348 0.970 0.676 0.372 0.200
MX-06070 23.249 14.076 9.864 8.028 6.012 4.237 3.522 1.455 1.014 0.555 0.300
MX-06100 38.748 23.460 16.440 13.380 10.020 7.062 5.870 2.426 1.690 0.930 0.500
MX-06120 46.498 28.152 19.728 16.056 12.024 8.475 7.044 2.911 2.028 1.110 0.600
MX-12012 4.650 2.815 1.973 1.606 1.202 0.847 0.704 0.291 0.203 0.111 0.060
MX-12040 15.499 9.384 6.576 5.352 4.008 2.825 2.348 0.970 0.676 0.372 0.200
MX-12070 27.124 16.422 11.508 9.366 7.014 4.944 4.109 1.698 1.183 0.648 0.350
MX-12120 46.498 28.152 19.728 16.056 12.024 8.475 7.044 2.911 2.028 1.110 0.600
MX-12240 92.995 56.304 39.456 32.112 24.048 16.950 14.088 5.821 4.056 2.232 1.200
MX-12310 120.119 72.726 50.964 41.478 31.062 21.893 18.197 7.519 5.239 2.883 1.550
MX-12400 163.200 97.200 68.800 57.960 41.280 29.792 24.640 10.441 7.240 4.040 2.100
MX-12600 265.200 157.950 111.800 94.185 67.080 48.412 40.040 16.967 11.765 6.565 3.413
MX-12700 285.600 170.100 120.400 101.430 72.240 52.136 43.120 18.272 12.670 7.070 3.675
MX-121000 408.000 243.000 172.000 144.900 103.200 74.480 61.600 26.103 18.100 10.100 5.250
MX-122000 489.600 291.600 206.400 173.880 123.840 89.376 73.920 31.324 21.720 12.120 6.300
CONSTANT CURRENT
MX-06012 4.736 2.909 2.040 1.671 1.236 0.867 0.720 0.301 0.206 0.115 0.062
MX-06040 15.787 9.696 6.800 5.580 4.120 2.889 2.400 1.003 0.688 0.384 0.206
MX-06070 23.681 14.544 10.200 8.370 6.180 4.333 3.600 1.505 1.032 0.576 0.309
MX-06100 39.468 24.240 17.000 13.950 10.300 7.222 6.000 2.508 1.720 0.960 0.515
MX-06120 47.362 29.088 20.400 16.740 12.360 8.666 7.200 3.010 2.064 1.152 0.618
MX-12012 4.736 2.909 2.040 1.674 1.236 0.867 0.720 0.301 0.206 0.115 0.062
MX-12040 15.787 9.696 6.800 5.580 4.120 2.889 2.400 1.003 0.688 0.384 0.206
MX-12070 27.628 16.968 11.900 9.765 7.210 5.055 4.200 1.756 1.204 0.672 0.361
MX-12120 47.362 29.088 20.400 16.740 12.360 8.666 7.200 3.010 2.064 1.152 0.618
MX-12240 94.723 58.176 40.800 33.80 24.720 17.333 14.400 6.019 4.128 2.304 1.236
MX-12310 122.351 75.144 52.700 43.245 31.930 22.388 18.600 7.775 5.332 2.976 1.597
MX-12400 175.200 100.800 72.160 61.440 43.200 31.122 25.600 10.824 7.416 4.160 2.160
MX-12600 284.700 163.800 117.260 99.840 70.200 50.573 41.600 17.589 12.051 6.760 3.510
MX-12700 306.600 176.400 126.280 107.520 75.600 54.464 44.800 18.942 12.978 7.280 3.780
MX-121000 438.000 252.000 180.400 153.600 108.000 77.805 64.000 27.060 18.540 10.400 5.400
MX-122000 876.000 504.000 360.800 307.200 216.000 155.610 128.000 54.120 37.080 20.800 10.800
50 OF 63
CONSTANT CURRENT
DISCHARGE RATES IN WATTS AT 77°F (25°C)
AMPERES TO F.V 1.85 VOLTS PER CELL
TYPE
5 MIN 10 MIN 15 MIN 20 MIN 30 MIN 45 MIN 60 MIN
MX-06012 8.34 5.50 3.75 3.08 2.26 1.58 1.25
MX-06040 27.79 18.34 12.51 10.26 7.52 5.27 4.16
MX-06070 41.69 27.50 18.77 15.39 11.28 7.90 6.24
MX-06100 69.48 45.84 31.28 25.65 18.80 13.17 10.40
MX-06120 83.38 55.01 37.54 30.78 22.45 15.80 12.48
MX-12012 8.34 5.50 3.75 3.08 2.26 1.58 1.25
MX-12040 27.79 18.34 12.51 10.26 7.52 5.27 4.16
MX-12070 48.64 32.09 21.90 17.96 13.16 9.22 7.28
MX-12120 83.38 55.01 37.54 30.78 22.56 15.80 12.48
MX-12180 118.12 77.93 543.18 43.61 31.96 22.38 17.68
MX-12240 166.75 110.02 75.07 61.56 45.12 31.60 24.96
MX-12310 215.39 142.10 96.97 79.52 58.28 40.82 32.24
MX-12400 277.92 183.36 125.12 102.60 75.20 52.67 41.60
MX-12600 451.62 297.96 203.32 166.73 122.20 85.59 67.60
MX-12700 486.36 320.88 218.96 179.55 131.60 92.17 72.80
MX-121000 694.80 458.40 312.80 256.50 188.00 131.67 104.00
MX-122000 1389.60 916.80 625.60 513.00 376.00 263.34 208.00
CONSTANT CURRENT
DISCHARGE RATES IN WATTS AT 77°F (25°C)
AMPERES TO F.V 1.75 VOLTS PER CELL
TYPE
5 MIN 10 MIN 15 MIN 20 MIN 30 MIN 45 MIN 60 MIN
MX-06012 9.01 5.94 4.05 3.32 2.42 1.71 1.36
MX-06040 30.05 19.80 13.50 11.08 8.08 5.69 4.52
MX-06070 45.07 29.70 20.26 16.61 12.12 8.54 6.78
MX-06100 75.12 49.50 33.76 27.69 20.20 14.23 11.30
MX-06120 90.14 59.40 40.51 33.23 24.24 17.08 13.56
MX-12012 9.01 5.94 4.05 3.32 2.42 1.71 1.36
MX-12040 30.05 19.80 13.50 11.08 8.08 5.69 4.52
MX-12070 52.58 34.65 23.63 19.38 14.14 9.96 7.91
MX-12120 90.14 59.40 40.51 33.23 24.24 17.08 13.56
MX-12180 127.70 84.15 57.39 47.07 34.34 24.19 19.21
MX-12240 180.29 118.80 81.02 66.46 48.48 34.15 27.12
MX-12310 232.87 153.45 104.66 85.84 62.62 44.12 35.03
MX-12400 300.48 198.00 135.04 110.76 80.80 56.92 45.20
MX-12600 488.28 321.75 219.44 179.99 131.30 92.50 73.45
MX-12700 525.84 346.50 236.32 193.83 141.40 99.62 79.10
MX-121000 751.20 495.00 337.60 276.90 202.00 142.31 113.00
MX-122000 1502.040 990.00 675.20 553.80 404.00 284.62 226.00
CONSTANT CURRENT
I. Product Identity
Product: Sealed Lead Acid Battery
V. Reactivity Data
Stability: Stable
Hazardous Polymerization: Will not occur
Incompatibility (Material to Avoid): Solvents may dissolve battery case material
Hazardous Decomposition Severe overcharge and overheating may
Or Byproducts: cause sulfur oxide fumes.
60 OF 63
January 5, 2004
We hereby certify that all Union Battery's Maintenance Free Rechargeable Sealed Lead
Acid Batteries conform to the UN2800 classification as "batteries, wet, non-spillable,
electric storage".
th
We further certify that under IATA Dangerous Goods Regulations, 47 Edition,
UN2800, Union Battery's sealed acid batteries meet the requirements to conform to
special provision A67, classifying them as non-dangerous goods. The Union Battery's
sealed acid batteries are therefore EXEMPT from the subject regulations for dangerous
goods and are acceptable for transport on both cargo and passenger aircraft.
For you reference:
IATA Dangerous Goods Regulation, 44th Edition, Section 4.5A, Special Provision;
A67 Non-spillable batteries are considered to be non-dangerous if at a
temperature of 55 deg. C(130 deg. F), the electrolyte will not flow
from a ruptured or cracked case and there is no free liquid to flow
and if, when packaged for transport, the terminals are protected from short
circuit.
Composition of
Gas evolution per second generated gas(%,
icA
Cathode Anode Log (ia/i c) v/v)
Ec - Ea (if i a
Potential Potential [Equation ia/i c
(V) assumed
Ec (V) Ea (V) (8)]
10A) Oxygen Hydrogen
(ia x (10 i c/ ia)x Total Oxygen Hydrogen
11200)/(2x96500) 0.1160
2.30 2.20 +0.10 0.8455 7.0065 1.427246 0.5803 0.1655605 0.7459 77.8 21.2
2.30 2.22 +0.08 1.0764 4.7468 1.10668 0.5803 0.244375 0.8247 70.4 29.6
2.30 2.25 +0.05 0.42275 2.6470 3.77786 0.5803 0.438232 1.0185 57.0 43.0
2.30 2.28 +0.02 0.1691 1.4761 6.77461 0.5803 0.785855 1.3662 42.5 57.5
2.30 2.29 +0.01 0.08455 1.2149 8.23113 0.5803 0.954811 1.5351 37.8 62.2
2.30 2.295 +0.005 0.042275 1.10224 9.07243 0.5803 1.052402 1.6327 35.5 64.5
2.30 2.32 -0.02 0.1691 1.4761 6.77461 0.5803 0.785855 1.3662 42.5 57.5
2.30 2.35 -0.05 -0.4275 0.3778 26.46903 0.5803 3.070407 3.6507 15.929.6 84.1
63 OF 63