DESIGN OF SUMP PIT OF VOL.

5 m3 Units in meter

100 HPP

99.2 IL of PIPE

IL 96.5

D 2

B
1.50

Calculation of Retantion Depth

Depth required to dead storage = volume/area 1.7 m

Consider additional free board of 0.25 m

Total Depth 2.7 m

Air Products Internal Use Only


Design of RCC cable trench

1.5

1.5 EP WP SUR
8.1 15 10
1.8 kN/mm2 kN/mm2 kN/mm2

Grade of Concrete M25 25 N/mm2


Grade of steel Fe500 500 N/mm2

Submerged Unit weight of soil 18 kN/m3


Unit Wt of Water 10 kN/m3

Overall Depth of wall 150 mm 0.150 m


Cover 40 mm 0.04 m
Effective depth 110 mm 0.11 m
Width 1000 mm 1.00 m
Base slab Depth 200 mm 0.20 m
Coefficient of earth pressure 0.3
Cover thikness 250 mm 0.25 m
Effective length 1.65 m
Design of Side walls

Earth pressure P1 6.1 kN/m


Water presuure P2 11.25 kN/m
Surcharge P3 15 kN/m

Moment Due to P1 M1 3.0375 kN-m/m


Moment Due to P2 M2 5.625 kN-m/m
Moment Due to P3 M3 11.25 kN-m/m

Total Moment @ Base of wall M 19.9125 kN-m/m

Check for depth


M = 0.138fckbd2 75.972 mm ok

factored moments Mu 29.8688 kN-m/m

Mu/bd2 2.47 N/mm2


Percentage of steel 0.648 % As per SP-16 P No 49
Main reinfor
Area of steel requied Pt*bd/100 712.8 mm2

Check
Asv min 0.002Ac 300 mm2 Eurocode 2- Design of concrete structures
clause 9.6.2
Asv max 0.04Ac 6000 mm2

Asv provided 712.8 mm2

Air Products Internal Use Only


Dia Of bar 12 mm
spacing 1000 * (p * d2/4)/ Ast reqd 158.586 mm

Spacing should not gretter than min of 3D 450 mm


400 400 mm 2

Provide 12 mm@ 159 mm c/c spacing

Horizontal reinforcement Eurocode 2- Design of concrete structures


Ash min, Min of 25% of vert reinf 178.2 mm2
or
0.001Ac 150 mm2

Ash provided 178.2 mm2

Dia Of bar 10 mm
spacing 1000 * (p * d2/4)/ Ast reqd 440.516 mm

Spacing should not gretter than 400 400 mm

Provide 10 mm@ 400 mm c/c spacing

Design of Base slab


Self weight of Wall W1 11.25 kN
Self weight of slab W2 9 kN
Weight of cover W3 11.25 kN
lIve load W4 10kg/m2 0.18 kN
Cable tray load W5 100kg/m2 1.8 kN

Total 33.48 kN

Upward pressure from soil 18.6 kN/m

factored upward pressure 27.9 kN/m

Moment @ mid span wl2/8 9.49472 kN-m

Mu/bd2 0.23737
Main reinfor
percentage of steel 0.073 % As per SP 16

Area of steel requied Pt*bd/100 146 mm2 Eurocode 2- Design of concrete structures

270.4 mm2

Asmax 0.04Ac 8000 mm2

Asv provided 270.4 mm2

Dia Of bar 10 mm
spacing 1000 * (p * d2/4)/ Ast reqd 290.311 mm

Spacing should not gretter than min of 3d 600 mm


400 400 mm

Provide 10 mm@ 290 mm c/c spacing

Air Products Internal Use Only


Distrubution steel

As min 20% of principal reinf 29.2 mm2 Eurocode 2- Design of concrete structures

Dia Of bar 10 mm
spacing 1000 * (p * d2/4)/ Ast reqd 2688.36 mm

Spacing should not gretter than min of 3h 600 mm


400 400
Main steel
Provide 10 mm@ 400 mm c/c spacing

Air Products Internal Use Only