Table of Contents
2. Install Place
3. Elevator Type
1) Mechanical elevator
2) Electronic(Digital) Elevator
1. Elevator 384
Operation panel
Reader
Elevator
Operation panel
Wiegand
Standard Software
Elevator 384
Reader
Under 100M
• Connect reader to Elevator 384(Elevator access control panel) via Wiegand communication.
Operation panel
Wiegand Wiegand
RS-485
Standard Software
Elevator 384 Up to 1,000 meter
Reader
Over 100M
• If the distance between elevator control panel and reader inside of elevator is over 100M,
Wiegand repeater is required.
Control cabinet
Elevator car
Standard Software
Elevator 384
Operation
Panel
Elevator controller
- If a building is higher than 30 floors, the distance between Access control panel and reader installed in
elevator car might more than 100M, you should measure distance.
- If the distance is longer than 100M, you should use Wiegand repeater.
TPS Room C
Elevator car
Standard Software
Elevator 384
Operation
Panel
∙ TPS Room
- Tele communication Pipe Shaft Room
- If the distance between Access control panel and reader is longer than 100M, you should use Wiegand repeater
Operation panel
Control cabinet
Standard Software
Reader
Elevator controller Elevator 384
Elevator
- High maintenance fee is required when there is some problem in access control system,
because engineers from both company access control system and elevator have to visit together for trial run .
Dry contact
N
Elevator car
Dry contact
3
Dry contact Elevator controller
2 Operation
Panel
1
Dry contact
∙ Mechanical Elevator
- The elevator that each elevator button on elevator operation panel is connected by
respective dry contact line to Elevator controller.
Dry contact
N Proximity reader
Dry contact
2 COM
1 NO
Output port
for 2nd floor
※ Emergency switch
should be installed
for ACS fail situation.
Emergency
Switch Wiegand
Elevator 384
Software Package Development 11
ⓒ 2019 IDTECK Co. Ltd.
Ⅱ. Important consideration
3. Elevator type
2) Electronic Elevator
N
Elevator car
3
RS485 Elevator controller
2 Operation
Panel
∙ Electronic Elevator
- The elevator that each elevator button on elevator operation panel is connected
by one RS485 line to Elevator controller
- Interface panel (H/W Ass`y ) which supports receiving dry contact signal of each floor from
IDTECK Elevator access control panel should be provided by elevator company
Software Package Development 12
Ⅱ. Important consideration
3. Elevator type
Diagram for Electronic elevator
RS485
※ - Interface panel (H/W Ass`y )
1
which supports receiving dry
contact signal of each floor
Interface panel
from IDTECK Elevator access
(H/W Ass`y )
control panel should be
provided by elevator company
NC
1
COM
NO
※ Emergency switch
should be installed
for ACS fail situation. Emergency
Switch
Wiegand
Elevator 384
Software Package Development 13
ⓒ 2019 IDTECK Co. Ltd.
Diagram of IDTECK Standard Software
- IDTECK Standard software provide
① Access control
② Elevator control
Access control system
Elevator control
Door access control
IDTECK
Standarad Software ITDC ICON100 Elevator 384
Operation
Panel