0 evaluări0% au considerat acest document util (0 voturi)
11 vizualizări1 pagină
This document is a tender call notice inviting quotations from manufacturers and suppliers for the supply, erection, and commissioning of a 400KVAR APFC panel. It provides specifications for the components required, including incoming and outgoing items. Technical requirements specify that the panel must be fabricated from CRCA sheet steel, be floor mounted, cubical type, and confirm to industrial standards. Quotations must be submitted by July 5th and include details of the bidding company/firm along with past performance certificates and after-sales service support. The selected supplier will be responsible for a 3-year performance warranty on capacitors and detuned reactors.
This document is a tender call notice inviting quotations from manufacturers and suppliers for the supply, erection, and commissioning of a 400KVAR APFC panel. It provides specifications for the components required, including incoming and outgoing items. Technical requirements specify that the panel must be fabricated from CRCA sheet steel, be floor mounted, cubical type, and confirm to industrial standards. Quotations must be submitted by July 5th and include details of the bidding company/firm along with past performance certificates and after-sales service support. The selected supplier will be responsible for a 3-year performance warranty on capacitors and detuned reactors.
This document is a tender call notice inviting quotations from manufacturers and suppliers for the supply, erection, and commissioning of a 400KVAR APFC panel. It provides specifications for the components required, including incoming and outgoing items. Technical requirements specify that the panel must be fabricated from CRCA sheet steel, be floor mounted, cubical type, and confirm to industrial standards. Quotations must be submitted by July 5th and include details of the bidding company/firm along with past performance certificates and after-sales service support. The selected supplier will be responsible for a 3-year performance warranty on capacitors and detuned reactors.
Quotations are invited in sealed cover from the Reputed Manufacturers/Suppliers for Supply, Erection and Commissioning of APFC Panel of 400KVAR with the detail specifications mentioned below. Sl.No. Item Description Make Qty INCOMING 1 ACB-800A,MDO 3P, 50 KA Ics=Icu=Icw with LSIG L&T/ABB/Siemens 1 2 APFCR Relay (12 steps) BELUK Beluk 1 3 On delay Timer L&T/ABB 1 4 CT (600/5A) 5VA, Cl-1 Kappa/Ampturn 4 5 VAF Meter L&T/ABB/Prok 1 6 Indicator - Red, Yellow L&T/ABB/Siemens 2 7 Indicator - Blue L&T/ABB/Siemens 1 8 Auto Manual Selector Switch Salzer/Kaycee 1 9 Control Contactor (4NO) L&T/ABB/Siemens 10 10 Emergency stop push button with NC contact L&T/ABB/Siemens 1 11 MCB 6A DP L&T/ABB/Siemens 1 12 Control Fuse base - 32A L&T/ABB/Siemens 3 13 HRC Fuse2A L&T/ABB/Siemens 3 14 Cooling Fan Best Quality 4 OUTGOING A 50KVAr x 6 Nos 1 MCCB-125A, 3P, 50 KA with SP.LINK L&T/ABB/Siemens 6 2 MOC-50, CONTCATOR L&T/ABB/Siemens 6 3 Add on Aux. Cont. Block 1NO+1NC L&T/ABB/Siemens 6 4 Push Button On & Off L&T/ABB/Siemens 12 5 Indicator Red & Green (ON & OFF) L&T/ABB/Siemens 12 6 7% Detuned Reactor copper 50kVAr L&T/ABB/Meher 6 7 Capacitor -30KVAr , 480V AC, Box type Ultra Heavy Duty L&T/ABB/Epcos 12 B 25KVAr x 3 Nos 1 MCCB-63A, 50 KA, 3P with SP.LINK L&T/ABB/Siemens 3 2 MOC-25, CONTCATOR L&T/ABB/Siemens 3 3 Add on Aux. Cont. Block 1NO+1NC L&T/ABB/Siemens 3 4 Push Button On & Off L&T/ABB/Siemens 6 5 Indicator Red & Green (ON & OFF) L&T/ABB/Siemens 6 6 7% Detuned Reactor copper 25kVAr L&T/ABB/Meher 3 7 Capacitor -30KVAr , 480V AC, Box type Ultra Heavy Duty L&T/ABB/Meher 3 C 10KVAr x 2Nos 1 MCCB-32A, 50 KA, 3P with SP.LINK L&T/ABB/Siemens 2 2 MOC-12.5, CONTCATOR L&T/ABB/Siemens 2 3 Add on Aux. Cont. Block 1NO+1NC L&T/ABB/Siemens 2 4 Push Button On & Off L&T/ABB/Siemens 4 5 Indicator Red & Green (ON & OFF) L&T/ABB/Siemens 4 6 7% Detuned Copper Reactor 10kVAr L&T/ABB/Meher 2 7 Capacitor -12.5KVAr , 480V AC, Box Type Ultra Heavy Duty L&T/ABB/Epcos 2 D 5KVAr x 1Nos 1 MCCB-16A, 3P, 50KA with SP.LINK L&T/ABB/Siemens 1 2 MOC-8.5, CONTCATOR L&T/ABB/Siemens 1 3 Add on Aux. Cont. Block 1NO+1NC L&T/ABB/Siemens 1 4 Push Button On & Off L&T/ABB/Siemens 2 5 Indicator Red & Green (ON & OFF) L&T/ABB/Siemens 2 6 7% Detuned Copper Reactor 5kVAr L&T/ABB/Meher 1 7 Capacitor -7.5KVAr , 480V AC, Box Type Ultra Heavy Duty L&T/ABB/Epcos 1 TECHNICAL REQUIREMENTS 1 Panel should be duly fabricated with 2mm CRCA sheet steel with Angle frame, powder coated, free standing, cubical type, floor mounted with internal wiring, Indoor type & with AL.Busbar with CPRI approved certificate. 2 The Incomer ACB should be suitable for LSIG Protection with ICW=50KA for 1 sec 3 The outgoing MCCB should be suitable for LI Protection. 4 APFCR Relay (12 steps) for displacement as well as distortion reactive power correction. 5 All Capacitor should be suitable for 480V AC, BOX TYPE ULTRA HEAVY DUTY 6 The panel should be cubical type & should be confirm to 3 A Terms and Conditions : a. Party should have earlier experience of supply of APFC panel and minimum 3 customers’ performance certificates for >300KVAR APFC with 7% detuned reactor should be attached. Offers without performance certificate will be summarily rejected. b. Performance warranty for 3 years for capacitors and Detuned Reactors should be given in writing. c. Price Basis: The quoted price should be FOR, Cuttack basis. The Technical and Financial Bids should be submitted separately in a closed envelope superscribing on the top “Quotation for APFC Panel of 400KVAR”. The quotations should reach the undersigned within 5thJuly 2019. The participating firms should also submit details of their Company/Firm along with their service back-up. The undersigned reserves the right to reject any/or all quotations without assigning any reason thereof. In the matter of any dispute the jurisdiction shall be within Courts in Cuttack, Odisha. Working General Manager ‘The Samaja’ Gopabandhu Bhawan, Buxibazar Cuttack-753001 (Odisha) Email: gm@samaja.in