1.

Improvements and additions


1) Added OPC UA function
The OPC-UA function has been added to the XGL-EFMT (B) module. Please refer to the
product manual for the extension of OPC-UA function for XGL-EFMT (B) module.

2) Find Device function of ST program has been improved.


Find Device has been improved to find devices assigned to variables.

3) XGB thermocouple input module function added


An external 24V power abnormality detection function has been added to the XGB
expansion thermocouple input module (XBF-TC04S). Whether an external power failure
occurs can be confirmed by the module automatic variable (_ □□ _EXT_PWR_ERR). For
more information on the added features and support O/S versions, please refer to the
module user manual.
4) User library improvements
Improved the existing user library creation UI. Easily reorganized UI and easy to add with
drag-and-drop functionality.
Please refer to the manual for details.

[Library Manager]

[Drag and drop function]


5) Improved custom scaling apply
It has been improved to display the same size when changing the size change (DPI) of
text, apps and other items over 100% in high resolution (UHD or higher) monitor.
(Changed to registry value)

6) Added two local ethernet related flags


Flag for high performance XGT PLC has been added (XGI-CPUN, XGK-CPUSN, CPUHN,
CPUUN)

_L_ETHERNET_WAR: Local Ethernet alert


_L_ETHERNET_WAR_INIT: Initializing Local Ethernet Alerts

7) Add custom frame BCC type - CRC8


Refer to the product manual for applicable models and versions.

[order]
One. In the User Frame Definition Group window, click the Add Top BCC button.

2. In the Add BCC dialog box, click the Format drop-down list.
3. Click the [OK] button and CRC8 type BCC will be added to the user frame definition
group window.

8) Read module information when reading online


If the I/O information of the PLC connected to the project information does not match
when reading online, the parameters of the module can not be read. The readout has
also been improved to reconfigure I/O information.

When [Online] - [Read], the information of the communication module is automatically


updated like open from PLC.

9) The [Motion Command] function for testing of XMC products now supports [All Axis]
command function. The user can perform test commands at up to 36 axes at a time
using the full axis command function.

10) A comment has been added to the command dialog of XGK(B).

11) The following command has been added.

 XMC-E32A: LS_CrossSealCamGen, LS_RotaryKnifeCamGen, LS_OnOffCam


For details on the operation of the command, refer to the instruction manual of the
product.
2. Error correction
1) Fixed an issue where the variable does not change normally when Replace All.
Fixed a problem where Replace does not work normally in Variable/Comment window
when Replace All is done in Variable/Comment window.

2) Correct error display of comparison result of real number comparison instruction


Fixed an issue where the comparison result was not displayed correctly when comparing
the real number type (single precision real number, double precision real number)
comparison command.

3) The parameter names of some XGK(B) series commands have been changed.
Duplicate commands with the same parameter name separated by case
(TON_EN, TOFF_EN, TMR_EN, TMON_EN, TRTG_EN, TLMT_EN, TDLY_EN)

If the parameter name is recognized as a device, modify d1, D1 to Dst1, n1, N1 to Num1
(117 commands such as WSFL, WSFR, XCHG)

4) XBMHP Auto Assign Project Simulator Error


Fixed a problem where simulator does not work properly in auto assignment project