Engineering Structures
journal homepage: www.elsevier.com/locate/engstruct
a r t i c l e i n f o a b s t r a c t
Article history: The seismic performance of coupled shear wall systems is governed by the shear resistance of their cou-
Received 27 October 2015 pling beams. Steel fibre reinforced concrete (SFRC) is widely applied in coupling beams for its positive
Revised 25 September 2016 contribution to their ductility. This study deals with the seismic behaviour of SFRC coupling beams using
Accepted 27 September 2016
conventional reinforcements and develops a simplified model that applies the Mohr-coulomb failure cri-
terion to predict the seismic shear strength of SFRC coupling beams. Variables studied include concrete
compressive strength, fibre volume fraction and span-to-depth ratio. Results show that steel fibres
Keywords:
improve the shear strength, deformation and energy dissipation capacity of the SFRC coupling beams.
Shear strength
Steel fibre reinforce concrete
When fibre volume fraction is greater than 2.5% or span-to-depth ratio excesses 2.5, SFRC coupling beams
Seismic assessment present an excellent seismic performance and avoid effectively brittle shear failure. Using the Mohr-
Coupling beam Coulomb failure criterion, a simplified shear model was proposed for SFRC coupling beams and presents
Mohr-Coulomb failure criterion a good accuracy and reliability. Furthermore, taking into account the negative effect of span-to-depth
ratio, the proposed shear model was modified further. The comparative results demonstrated that the
new shear model presents a more reasonable assessment accuracy and higher reliability.
Ó 2016 Elsevier Ltd. All rights reserved.
http://dx.doi.org/10.1016/j.engstruct.2016.09.056
0141-0296/Ó 2016 Elsevier Ltd. All rights reserved.
G. Cai et al. / Engineering Structures 128 (2016) 428–440 429
Nomenclature
fc0 compression strength of concrete s shear stress of cracked section of coupling beam
ln/d span/depth ratio r normal stress of cracked section of coupling beam
V shear strength of coupling beam c the cohesion of materials
Vcf shear provided by fibre reinforce concrete h the angle of internal friction
0
Vsd shear provided by diagonal reinforcements f cfrc compression strength of SFRC
Vs shear provided by transverse reinforcements Vu ultimate shear of coupling member in Fig. 4
bw the width of the coupling beam Vc concrete shear in compression zone in Fig. 4
d the height of the coupling beam Vs shear force due to transverse steel in Fig. 4
Avd the cross-sectional area of one diagonal bar d overall depth of section in Fig. 4
fy yield strength of diagonal bars scf shear stress along the diagonal plane in Fig. 4
fyt yield strength of transverse reinforcements rcf normal stress perpendicular direction in Fig. 4
Av the cross-sectional area of shear rebars T tension of longitudinal steel in Fig. 4
S spacing of transverse reinforcements Fc concrete force in compression zone
ft tensile strength of original concrete A, B calculation factors
kf factors of steel fibre, calculated as qflf/df c compression-to-tension strengths ratio
qf volume fraction of steel fibre VCB shear strength of SFRC coupling beam
lf/df aspect ratio of steel fibre g affecting factor due to ln/d
h0 effective height of coupling beam VSFCB modified shear strength of SFRC coupling beam
SE
CB
CB
CB
(a) Single RC wall (b) Coupled RC wall by CBs (c) Seismic effects and def n
CB SE CB
SE
CB: coupling beam
G G
G : gravity
SE: seismic effects
conventional RC coupling beams. This was attributed to the fact same as the one reported by previous studies [e.g. 9]. Lequesne
that SFRC beam can resist a higher shear deformation and provide et al. [10] also reported that high performance fibre reinforced
a better cracking resistance capacity than normal RC ones, which is concrete (FRC) can reduce the required area of diagonal
430 G. Cai et al. / Engineering Structures 128 (2016) 428–440
reinforcements by 70% relative to a code-compliant design. of three shear contributions from conventional transverse rein-
Besides, Canbolat et al. [1] also illustrated that the use of high- forcements, diagonal reinforcements and fibre reinforce concrete
performance fibre reinforced cement composites (HPFRCC) could respectively. The design equation is given by,
be an alternative design proposal for RC coupling beams of the qffiffiffiffi
0 Av f yt d
shear wall systems without using diagonal reinforcements. They V ¼ V cf þ V sd þ V s ¼ 0:4 f c bw d þ ð2Av d f y sin aÞ þ ð1Þ
explained that HPFRCC exhibits a tension strain hardening beha- S
viour even though it still has a number of cracking and concrete where Vsd is taken as zero for the SFRC coupling beams only having
crunching. It implies that fibre reinforced concrete could be used conventional reinforcements.
to reduce the dependency of heavily diagonal reinforcing in cou- Zhang et al. [12] have reported that the addition of moderate
pling beams while maintaining similar strength and ductility to volume of steel fibres not only can enhance the shear strength of
well-detailed diagonally reinforced ones [1]. RC coupling beams, but also can improve the spalling resistance
Besides, comparing with normal RC coupling beams, HPFRCC of cover concrete, as well as the concrete crushing or the damage
coupling beams can exhibit a higher deformation capacity with at shear-compressive zones. This is benefited to ultimate failure
more uniform crack distribution and stable strength degradation modes of RC coupling beams, that is to realize the favorable change
[11]. Zhang et al. [12] also experimentally verified that the ductility from shear-dominant failure to flexure-dominant failure models.
and energy dissipation capacity of SFRC coupling beams using Meanwhile, according to the research on SFRC coupling beams
moderate steel fibres both were enhanced in about 20% when com- with low span-depth ratio (ln/d 6 2.5) and using conventional rein-
pared with the ones of normal RC coupling beams. However, the forcements, Zhang et al. [12] have proposed a shear strength model
experimental investigation focusing on the seismic behaviour of for these SFRC coupling beams on the basis of Chinese design code
SFRC coupling beam is still very limited. In addition, as one of [17], which can be expressed in the form of,
the most important seismic design indexes of RC members, the
shear strength of RC coupling beams is currently being concerned Av f yt h0
V ¼ V cf þ V s ¼ 0:8ð1 þ 0:7kf Þf t bh0 þ 0:45 ð2Þ
by structural research community. The work conducted by Parra- S
Montesinos [11] demonstrated that the HPFRCC increases effec-
where kf is a characteristic value of steel fibre calculated as qf lf/df. ft
tively the shear strength and confinement of RC coupling beams
is the tensile strength of original concrete obtained from tension
subjected to shear reversals. However, as regards to SFRC coupling
test referring to Chinese test standard [17]. qf is fibre volume frac-
beams, there is not universally-accepted method to predict their
tion, and lf/df is the aspect ratio of steel fibre. ho is the effective sec-
seismic shear strength.
tional depth of coupling beam which is taken as the distance from
The primary purpose of the current study is to develop a practi-
the center of tensile longitudinal reinforcements to compressive
cal design model for predicting the shear strength of SFRC coupling
concrete edge.
beams with conventional reinforcements using some relevant the-
ories and the deformation mechanism of SFRC coupling beams
under high shear reversals. Meanwhile, the seismic behaviour of 3. Proposed formula for evaluating the shear strength of SFRC
SFRC coupling beams will be experimentally investigated and syn- coupling beams
optically discussed. Through comparing experimental results of the
SFRC coupling beams and the test data obtained from literature 3.1. Failure mechanism
review, existing and proposed models to predict the shear strength
of SFRC coupling beam will be examined and discussed. RC coupling beams subjected to seismic loads usually present a
similar deformation development and some primary damage char-
acteristics when compared with RC columns. To clearly understand
2. Existing evaluation models for evaluating the shear strength the shear transferring and failure behaviour of SFRC coupling
of SFRC coupling beams beams, the deformation and failure mechanism of normal RC cou-
pling beams are briefly reviewed here.
As described previously, while extensive studies have focused When subjected to a low transversal reversed cyclic load, RC
on the shear behaviour of RC coupling beams, a few shear design coupling beams can deform elastically or freely as the RC support
methods have been proposed for them specifically for SFRC cou- elements under seismic loads. In theory, the enhancement action
pling beams. Aktan and Bertero [13] and Aristizabal-Ochoa [14] of steel fibres to concrete is not obvious at this moment because
reported that conventionally reinforced concrete coupling beams the steel fibres just are considered as aggregates in a non-
(CCBs) still exhibit a satisfactory performance when their nominal cracked concrete. Once the first flexural crack was observed, how-
gross section shear stress are below to 0.25fc0 0.5 (in MPa), if they ever, the elastic deformation of RC coupling beam stops and steel
failed in a flexure-dominate mode. Besides, ACI 318 code [15] fibres start to work at the cracked section and the beam begins
recommended that the RC coupling beams with a span/depth ratio to resist flexural deformation. Since the emergence of the first
(ln/d) of less than 4.0 could be designed into a diagonally reinforced shear crack, a well-designed RC coupling beam usually presents
concrete coupling beams (DRCBs). On the other hand, the code also stable flexural and shear cracking development. The process
requires that the coupling beams with ln/d of less than 2.0 and the accompanies generally with a further degradation of stiffness and
ones with a sectional stress exceeding 0.33fc0 0.5 (in MPa) on gross spalling of concrete cover until the beam achieves its maximum
sectional area must be designed to use diagonally reinforcements. shear resistance capacity. Subsequently, certain longitudinal steel
Moreover, the diagonal elements must have a width outside rebar starts to yield and the shear resistance of RC coupling beam
dimension exceeding half of beam width and a depth of 0.2 times reduces due to the degradation of dowel action of longitudinal
beam width, referring to Section 21.7.7.4 (a) in ACI 318 [15]. For steel or the decline of interlock action of coarse aggregates in con-
the coupling beams with ln/d of greater than 4, the code suggested crete, etc. Finally, RC coupling beam fails due to the loss of shear
the beams should satisfy the requirements in Section 21.5 which resistance caused by the yielding of more reinforcement rebars
means that they should be designed as flexural members in term or a crushing in core concrete.
of special moment frames. The ultimate failure mode of RC coupling beam can be divided
Lequesne and Wight [16] have proposed a calculation method into three types, i.e., flexure failure, flexure-shear failure and shear
to predict the shear strength of FRC coupling beams which consists failure modes respectively. For the RC coupling beams with
G. Cai et al. / Engineering Structures 128 (2016) 428–440 431
flexure-dominant failure mode, flexure cracks usually can obtain a concrete. Most of classical engineering materials somehow follow
sufficient development without obvious diagonal shear cracks. This this rule in at least a portion of their shear failure envelope [19].
failure is usually caused by a lateral moving of coupling beam at its As shown in Fig. 3, the Mohr-Coulomb failure criterion represents
main flexural cracked section which normally at the ends of cou- a series of linear failure envelope curves (or can be called as
pling beams. Flexural-slip failure mode was considered as one of strength curves) in a principal stress plane (see Plane B) that can
classic flexure-dominant failure modes caused usually by the buck- be obtained from a relationship between the shear stress (s) and
ling action of some longitudinal reinforcement bars at main subjected normal stress (r), as shown in Eq. (3). It should be noted
cracked section [18]. With regard to RC coupling beams failed in that the compression direction is assumed to be positive in the
shear mode, however, these beams usually show completely devel- following discussions.
oped shear cracks in their hinge region before longitudinal steel
rebars achieve their yielding level, even though the first crack is s ¼ r tan h þ c ð3Þ
still a flexural type. Subsequently, after some shear loading cycles,
In this equation, s is the internal shear stress, r is normal stress, and
some major 45-degree and large-width major shear cracks begins c is the intercept of the failure envelope in the shear stress axis,
to occur and results in a rapid degradation in shear strength until
which is often called cohesion; h represents the internal angle of
final failure, regardless of the yielding of longitudinal reinforce- friction which is computed as the slope of failure envelope curve
ments. On the other hand, for RC coupling beams with flexure- in this figure.
shear dominant failure mode, longitudinal reinforcements usually According to previous descriptions, it is very important to
achieve their yielding status after a stable and continuous cracking develop a shear strength equation with a proper physical meaning
development. The beams also can present main diagonal shear for SFRC coupling beams taking into account main shear transfer
cracks once their residual shear strengths at certain displacement mechanisms of coupling beam with shear-dominant failure mode
are lower than their flexural resistance capacities. In these cases, and the effects of key structural factors. Fig. 4 shows the various
the shear strength of this type of coupling beams usually deterio- shear transfer mechanisms of SFRC coupling beams using stirrups
rates when certain transverse shear reinforcement fractures or and conventional reinforcements. Referring to above described
starts to yield. analyses regarding the deformation and failure mechanisms of
normal RC coupling beams under reversed shear cyclic loads, some
3.2. Calculation formula of shear strength for SFRC coupling beams basic assumptions are made: (1) The diagonal plane has an inclina-
tion of 45-degree with the longitudinal direction of beam which
The Mohr–Coulomb theory is a widely-used mathematical has been experimentally verified by previous studies and analyses
model that describes the response of brittle materials such as e.g. [1,20]; (2) The failure of diagonal plane complies with the Mohr
Vc
C
Fc
σcf
C-S τcf
d θ
T2
Vs3
Vs2
T1
Vs1 Y
X
Vu
Fc : Concrete compression; Vc: Concrete shear in compression zone;
T : Tension of longitudinal steel; Vs : Shear force due to transverse steel;
τcf : Shear stress along the diagonal plane; Vu : of member;
σcf : Normal stress C-S: Internal compression strut effect;
θ : Degree of main diagonal crack; d: Overall depth ;
pffiffiffi pffiffiffi
Coulomb failure criterion which is similar to RC columns under where the factors A and B are taken as 1=2 c and ðc 1Þ=2 c,
seismic loads [21]; (3) With regards to the internal compression respectively.
strut effectiveness, Kowalsky and Priestley [22] considered that a Therefore, based on Eqs. (7)–(9), the shear strength of SFRC cou-
typical value of compression zone range from 0.25 to 0.35 times pling beams is computed as,
of overall depth of RC columns under seismic loads. However, for
1:8A 0:1B þ 0:1 0
SFRC coupling beams with conventional reinforcements, consider- Vu ¼ Vs þ Vc þ f cfrc bd ð10Þ
ing without strong axial compressive action because of the absence
B þ 1:0
of external axial loads but having the enhancement effect of steel In the equation, the shear forces of the 45-degree truss mecha-
fibres to concrete at cracked section, the compression zone is taken nism Vs and shear contribution of concrete Vc are obtained refer-
as 10% of beam depth in SFRC coupling beams; (4) Similar to RC ring to the model proposed by ASCE-ACI committee 426 [23] (no
columns subjected to seismic loads, the tensile and compressive axial load), shown as the following two equations,
longitudinal reinforcing bars in coupling beams can balance them-
Av f yt 0:8d
selves internally [21]. Vs ¼ ð11Þ
On the basis of the above assumptions and considering with the S
equilibrium of all forces depicted in Fig. 4, the balance equations in qffiffiffiffiffiffiffiffi
0
the directions X and Y are obtained, as follows, V c ¼ 0:29 f cfrc 0:8bd ð12Þ
X 0:9db 0:9db X
Y ¼ V u þ rcf cos h scf sin h V si V c ¼ 0 As a consequence, the shear strength of SFRC coupling beams is
sin h sin h given by,
ð4Þ qffiffiffiffiffiffiffiffi
Av f yt 0:8d 0 1:8A 0:1B þ 0:1 0
X X Vu ¼ þ 0:29 f cfrc 0:8bd þ f cfrc bd ð13Þ
0:9db 0:9db S B þ 1:0
X¼ T i C F c rcf sin h scf cos h ¼ 0
sin h sin h
Referring to the various primary shear contributions of RC col-
ð5Þ umns in Priestley et al. model [24], the last shear components in
Meanwhile, using the assumption of the internal compression Eq. (13) can be considered as a comprehensive influence of steel
strut effect described above, the ultimate compressive resistance fibres on the shear transfer mechanism of coupling beam located
force of concrete Fc in compression zone is expressed as, at diagonal cracked section. On the other hand, it was well known
0 that the value of c ranges from 10 to 16 for conventional concrete
F c ¼ 0:1f cfrc bd ð6Þ [25] which has been simply considered as 10 in circular concrete
0 columns reported by first author of this paper [21]. However, due
where f cfrc
is fibre concrete compressive strength.
to the addition of steel fibres, the compressive and tensile
Therefore, according to the assumptions (1) and (4), the equilib-
strengths of steel fibre concrete both change simultaneously.
rium equations in the directions of X and Y axis are expressed in
Moreover, the increasing levels of the two strengths of steel fibre
the following forms of,
X concretes are different and depend nonlinearly on each other. This
Y ¼ V u þ 0:9dbrcf 0:9dbscf V s V c ¼ 0 ð7Þ indicates the using of a constant ratio c that is same as the one in
normal concrete is not appropriate in steel fibre concretes. Xu and
X Shi [26] evaluated the relationship of compressive strength,
X ¼ F c 0:9dbrcf 0:9dbscf ¼ 0 ð8Þ
splitting tensile strength and flexural strength of concretes using
In the two equations, by introducing two calculation factors A various fibres as well as proposed an empirical model for predict-
and B, as well as denoting the compression-to-tension strengths ing the splitting tensile strength of the concretes using their com-
ratio of steel fibre concrete as c and by referring to the simplifying pressive strengths. However, their database only included a few
method of the Mohr-Coulomb failure criterion in conventional specimens using straight steel fibres. In order to investigate the
concrete proposed by Architecture Institute Japan (AIJ) [21], the relationship between the ratio c and steel fibres volume fraction,
Mohr-Coulomb failure criterion for steel fibre concrete is presented a basic experimental investigation focusing on the mechanical
as, properties of straight steel fibre concretes is performed in this
study. The test program used some usually-used steel fibre con-
scf ¼ Af 0cfrc þ Brcf ð9Þ cretes with a compressive strength ranging from 30 MP to
12 2 18
SFRC compression/tensile strength
1.8 16
10 1.6 14
1.4
8 12
all data
(γ)
1.2
tensile
10
6 1
8
0.8 γ = -1.78ρ + 14.5
4 0.6 6 Fc=34-50MPa
R² = 0.31
0.4 4 Fc=60-70MPa
2 Xu and Shi model [26] Fc=50-60MPa
Xu and Shi model [26] 0.2 2 Fc=70-90MPa
0 0 0
0 2 4 6 8 10 12 0 1 2 3 0 0.5 1 1.5 2 2.5 3
tensile (kN) ρf (%)
Fig. 5. Compressive and splitting tensile strengths of steel fibre reinforced concrete.
G. Cai et al. / Engineering Structures 128 (2016) 428–440 433
80 MPa. The volume fractions of steel fibre (straight) in the con- 0.12
0.17 1.9
0.16 1.8
(9)
(9)
0.15 1.7
0.14 1.6
0.13 1.5
A = 0.0112ρ + 0.13
0.12 R² = 0.9902 1.4
B= -0.1413ρ + 1.78
Factor A
Factor B
0.11 1.3
R² = 0.9985
0.1 1.2
0.09 1.1
0.08 1
0 1 2 3 4 0 1 2 3 4
Fiber volumne ρ (%) in concrete ρ (%)
Table 1
Details of the specimens and main results.
Specimens Width B Depth d Hight ln ln/d Fibre concrete Longitudinal Transverse steel Fibre Results
steel
– fc0 ft Asl fyl Dts S fyt lf/df fyf qf Vmax Failure
(mm) (mm) (mm) (–) (Mpa) (Mpa) (mm2) (Mpa) (mm) (mm) (Mpa) (–) (Mpa) (%) (kN) modes
Where fc0 and ft are compression and tensile strength of concrete; ln/d is span-to-depth of member; Asl is total area of longitudinal steel bars; fyl, fyt, and fyf are yielding strength
of longitudinal, transerve reinforcement and fibre, respectively; Df and S is diameter and spacing of transverse reinforcements; lf/df is the aspect ratio of fibre; qf is the volume
fraction of fibre in concrete; Vmax is measured maximum lateral force; For failure modes, S-C: shear compression; S-T: shear tension; S: shear dominant; F: flexure dominant;
F-S: flexure-shear failure; F-S-C: flexure-shear compression failure.
type which has an aspect ratio of 42 and a yielding strength of steel connect plates were fixed to the upper shear wall through
380 MPa. The details of test setup and loading method are shown four pre-set steel bars (I). All steel connection plates and rebars
in Fig. 9. To evaluate the seismic response of these SFRC coupling have a high stiffness to ensure the stability and safety of the whole
beams, all specimens have been designed according to Chinese loading system during testing.
standard of CECS13-2009 [28] and Chinese National testing guide- A cyclic loading used in the vertical direction of beams was
line JGJ101-1996 [29]. Uniformly distributed longitudinal and divided clearly into two phases as shown in Fig. 10. To observe
transverse reinforcements were arranged to resist flexural and and collect detailed information of cracking development of the
shear deformation of these coupling beams. specimens at early stage, a load-control type loading (single cyclic
As shown in Fig. 9, each specimen was placed and rotated into for each level) was applied firstly until certain longitudinal rein-
the test setup system by connecting the upper stiff RC shear wall to forcement achieved its yielding level or when the envelope curve
strong reaction RC walls (D), and fixed to strong floor (Strong steel of the load-displacement of this specimen exhibits an obvious
beam, C) through the bottom RC shear wall. A quasi-static load was yielding point. At this moment, the specimen was considered to
performed to the upper stiff RC shear wall through a horizontal reach its yielding displacement (D) in this study. Subsequently,
hydraulic actuator (A) in the term of passing through the mid- to simulate the demands and impacts of earthquake action, some
span of coupling beams to induce an anti-symmetrical moment displacement-control loading cycles (2 cycles for each level) with
pattern to these coupling beams. The actuator was connected to certain displacement level were applied to each specimen, starting
the upper RC structural wall via a strong L-type steel loading frame from 1.0 time yielding displacement (D) (i.e. 1.0D, 2.0D, 3.0D, etc.).
(B) consisting of two high stiffness steel I-section beams. To con- During the testing, the cracking development, failure and detailed
nect the upper RC wall and the steel frame, four steel triangular- deformation and force of the specimens were recorded and
G. Cai et al. / Engineering Structures 128 (2016) 428–440 435
1800
Ve cal n
E Δ
1200
B
L
F I
800+0.5ln
600
D
A: Actuator of CBs);
B: Steel load frame;
H strong steel beam;
ln
0.5ln
D: wall (RC);
A E: Upper strong steel Beam;
G F: Strong steel columns;
600
2500
flexure-shear/flexure failure mode. When the ratios of ln/d were that ln/d ratio and steel fibre volume fraction both have a signifi-
small levels such as 1.0 and 1.5, large-width cracks were observed cant influence on the ultimate failure modes of the SFRC coupling
and no obvious lateral moving was confirmed in these coupling beams. When the ln/d ratio of coupling beam exceeds 2.0 or fibre
beams. On the other hand, when the ln/d ratios ranged from 2.0 volume fraction reaches 2.5% of concrete, SFRC coupling beams
to 3.0, some classical flexure-shear failures were confirmed accom- usually failed with a flexure-dominant failure mode.
panying with two X-type main diagonal cracks at two ends (hinge
zone) of these beams. The damage of the core parts of the two 4.2.2. General seismic response of SFRC coupling beams
X-type cracking zones increases with ln/d ratios. When ln/d The hysteretic curve is an important result to check the seismic
increases up to 3.5, however, the failure mode of coupling beam behaviour of RC elements and usually reflects some main points
completely switched into flexure failure mode which was mainly such as ultimate resistance capacity, stiffness and ductility devel-
attributed to larger and more flexural deformation of the beam. opment, as well as energy dissipation capacity. To understand
In addition, despite all specimens having different fibre volume the overall seismic performance of the SFRC coupling beams,
fraction and same ln/d of 2.0 also show a similar flexural cracking- Fig. 12 compares the hysteretic response of shear force-
resistance load of 30 kN and obvious 45-degree diagonal cracks displacement of some representative specimens.
finally, fibre volume fraction presents a significant influence on The results show that the SFRC coupling beams with a high ln/d
the cracking development of these beams. When the volume frac- ratio can exhibit larger ductility capacity owing to the beams have
tion increases up to 1.5%, the two X-type cracks located at two ends better flexural deformation capacity. Besides, the specimen with
of beams moved to the middle section of the beams until a new ln/d of 3.5 presents an excellent energy dissipation behaviour,
obvious X-type diagonal crack appeared at this zones. Besides, stable stiffness degradation and large deformation capacity, as well
the distribution of all cracks in these beams is more uniform shown as fails in a typical flexure failure mode. On the other hand, the
as Fig. 11. In other word, as fibre volume fractions increase, the results indicated that the compressive strength of fibre concrete
ultimate failure modes of SFRC coupling beams were changed from has no significant effect on the initial stiffness of the SFRC coupling
shear-tension to shear compression or flexure-shear failure. This beams, while higher strength concrete can improve their ultimate
changing is very benefit to the shear resistance capacity and defor- shear strengths and corresponding ultimate deformation levels.
mation of RC coupling beam under reversal cyclic shear loads. This is explained by the fact: when fibre concrete compressive
Table 1 lists the main experimental parameters and results of strengths are between 30 MPa and 40 MPa, the contribution of
all tested SFRC coupling beams, including failure mode and maxi- steel fibre on the ductility property of coupling beams is very lim-
mum shear resistance force, etc., while Fig. 11 demonstrates the ited due to the bond action is small level between this straight type
ultimate damage situations of the specimens. The results show steel fibre and concrete. When fibre concrete compressive strength
Fig. 12. Lateral force vs. displacement of some representative SFRC coupling beams.
increases, the energy dissipation capacity of SFRC coupling beams present a better initial deformation capacity comparing with the
was improved with a considerable degree. Therefore, the enhanc- conventional ones.
ing effectiveness of steel fibres on the whole deformation capacity
and ultimate shear resistance of SFRC coupling beams depends sig-
4.2.3. Effect of main variables on shear strength of SFRC coupling
nificantly on concrete compressive strength. Additionally, normal
beams
RC coupling beam shows a typical pinched force-displacement
As described previously in Section 3, the major shear contribu-
response characteristic when compared to SFRC coupling beams
tions of SFRC coupling beams usually come from three compo-
and usually fails with shear failure mode. This indicates the addi-
nents, i.e. steel fibre reinforced concrete, shear (vertical)
tion of steel fibre increases the energy dissipation and deformation
reinforcements and steel fibre in main cracked sections. Fig. 14
capacity of RC coupling beams. This kind pinched hysteretic
and Table 1 show a clear description related to the effects of fibre
response was improved significantly when steel fibre volume frac-
concrete compressive strengths, fibre volume fractions and ln/d
tion increases, especially as the fraction is higher than 2.0%. Fur-
ratio of beam on the ultimate shear strengths of SFRC coupling
thermore, tensile reinforcements also trend to reach their
beams failed in shear dominant failure mode. Results show that
yielding strengths when more steel fibres are used in concrete,
these three parameters all have a significant influence on the ulti-
which means these SFRC coupling beams can resist a larger lateral
mate shear strength of SFRC coupling beams. The shear strength of
deformation.
SFRC coupling beams increases with steel fibre volume fraction and
Fig. 13 shows the initial response of the envelope curves of
fibre concrete compressive strength, and decreases as the ln/d ratio
force-displacement of all tested SFRC coupling beams. Experimen-
of coupling beam.
tal result also verifies that SFRC coupling beams have higher initial
stiffness when low ln/d ratio was used, which is similar as normal
RC coupling beam. When the fibre concrete compressive strengths 5. Verification of the proposed formula in this study
increase up to 70 MPa, the higher concrete compressive strength
has resulted in an increase in the initial stiffnesses of the beams. In order to evaluate the accuracy and reasonability of existing
However, when fibre concrete compressive exceeds than 70 MPa, models to predict the shear strength of SFRC coupling beams and
because of the obvious brittle behaviour of concrete, the initial to check the proposed calculation method (i.e. Eq. (18)) in this
stiffnesses of SFRC coupling beams decrease as concrete compres- study, Fig. 15 compares the strength ratios (Vexp/Vmodel) between
sive strength, as shown in Fig. 13. As for the effect of steel fibre on experimental shear strength (Vexp) and their corresponding
the initial stiffness of coupling beams, the beams with steel fibre calculative values (Vmodel) obtained by various models, using the
lateral force(kN)
lateral force(kN)
280 Linear (S failure) 280 280
Fig. 14. Tested variables vs. shear strengths of SFRC coupling beams.
1 1 1
Fig. 15. Comparison of predicted strength ratio based on existing and proposed models.
exp/Vmodel
Vexp/Vmodel
1 1 1
0 0 0
0 0.5 1 1.5 2 25 45 65 85 0.8 1 1.2 1.4 1.6 1.8 2 2.2
Concrete compression strength (MPa)
Fig. 16. Effect of variables on the predicated strength ratio based on proposed model.
experimental results of the present study and the collected test Furthermore, aiming to further examine the reliability of the
data from literature review which focused on SFRC coupling beams proposed model to estimate the shear strength of SFRC coupling
reinforced by conventional reinforcements [12]. According to the beams in future practical design work, Fig. 16 studies the relation-
comparative results, the proposed model exhibits an improved- ship between Vexp/Vmodel ratios and several main structural factors
significantly prediction accuracy and high reasonability. The max- of coupling beams, such as concrete compressive strength, fibre
imum and minimum values of the Vexp/Vmodel ratios of this model volume fraction and span-to-depth ratio of beam ln/d. As presented
are 1.28 and 0.97, respectively, are better than that of the other in the figure, no obvious tendency is observed for the concrete
two models. Besides, the detailed statistical results of the ratios compressive strength and fibre volume fraction. This indicates that
of Vexp/Vmodel of the proposed model also indicate that it provides the current proposal can be used to design SFRC coupling beams
the closest agreement with the existing experimental results, with when using different concrete compressive strength or fibre vol-
a mean ratio of 1.08, a standard deviation of 0.09 and a coefficient ume fraction in practical engineering. For shear span ratio ln/d,
of variation of 8.28%. however, when it is less than 2.0, the negative effect of increasing
G. Cai et al. / Engineering Structures 128 (2016) 428–440 439
400 the ln/d ratio is greater than 2.5 or fibre volume fraction is
This study higher than 2.5%, SFRC coupling beams usually fail with a
350
Ref.[10] flexure-dominant failure mode, which avoids effectively a
Experimental strength (kN)
[16] Lequesne RD. Behavior and design of high-performance fibre-reinforced [24] Priestley MN, Verma R, Xiao Y. Seismic shear strength of reinforced concrete
concrete coupling beams and coupled-wall systems Doctoral columns. J Struct Eng 1994;120(8):2310–29.
dissertation. The University of Michigan; 2011. [25] Architecture Institute Japan. AIJ standard for structural calculation of steel
[17] GB50010-2002. Code for design of concrete structures English reinforced concrete structures. Tokyo: Marauzen; 2010 [in Japanese].
version. Beijing: National standard of China, China Architecture and Building [26] Xu BW, Shi HS. Correlations among mechanical properties of steel fibre
Press; 2002. reinforced concrete. Constr Build Mater 2009;23(12):3468–74.
[18] Gong BN, Fang EH. Behavior of reinforced concrete coupling beams between [27] Zollo RF. Fibre-reinforced concrete: an overview after 30 years of
shear wall under cyclic loading. Chin J Build Struct 1988;9(1):34–41 [in development. Cement Concr Compos 1997;19(2):107–22.
Chinese]. [28] CECS13-2009. Standard test methods for fibre reinforced concrete. Chinese
[19] Juvinal Robert C. Marshek Kurt. Fundamentals of machine component design. association for engineering construction standardization. Beijing: China
2nd ed.; 1991. p. 217. ISBN 0-471-62281-8. Planing Press; 2010.
[20] Khalifa ES. Analytical model for steel fibre concrete composite short-coupling [29] JGJ101-1996. Specification of test methods for earthquake resistant
beam. Compos B Eng 2014;56:318–29. building. Beijing: China Industry Standards; 1997.
[21] Cai G, Sun YP, Takeuchi T, Zhang J. Proposal of a complete seismic shear [30] Tassios TP, Moretti M, Bezas A. On the behavior and ductility of reinforced
strength model for circular concrete columns. Eng Struct 2015;100:399–409. concrete coupling beams of shear walls. ACI Struct J 1996;93(6).
[22] Paulay T, Priestley MJN. Improved analytical model for shear strength of [31] Harries KA, Fortney PJ, Shahrooz BM, Brienen PJ. Practical design of diagonally
circular reinforced concrete columns in seismic regions. ACI Struct J 2000;97 reinforced concrete coupling beams-critical review of ACI 318 requirements.
(3):388–96. ACI Struct J 2005;102(6).
[23] ASCE-ACI Task Committee 426. The shear strength of reinforced concrete
members. ASCE J Struct Div 1973;99:1091–187.