Sunteți pe pagina 1din 2

VEK M1H / VEK M2H


Induction loop detector for vehicle detection

FEATURES

 Isolation transformer between loop and detector


electronics

 Automatic calibration when switching on or


changing the adjustment of holding time

 Plastic housing with compact size to be


mounted directly on DIN-rail
(wiring on the housing)

 Adjustment of unlimited holding time possible

 All adjustments with DIP-switch on front panel

 Mode „direction indication“ for VEK M2H

 Permanent or pulse output adjustable


TECHNICAL DATA

Dimensions (W x H x D) 22.5 x 79 x 90 mm
without front connector
Protection class IP 40
Housing plastic clamp housing for DIN-rail
with 2x 3-pin. clamps
Power supply 24 V AC/DC, +/-10%
Power consumption max. 1.5 W
Inductance range 25-800 µH
Operating frequency 30-130 kHz
Sensitivity range 0.01 %-0.65 % in 4 steps
Loop lead-in max. 250 m
Signal outputs
VEK M1H 1 presence relay with contact n.c.,
1 pulse relay with contact n.o.,
adjustment of rest or operation
current principle for permanent relay
with shift switch on front plate
VEK M2H 1 presence relay with contact n.c.
per channel pulse output when
leaving of loop on channel 2,
adjustable relay function principle:
rest current / operating current resp.
closing / opening via jumper or
plumbline bridge adjustable
Switching voltage 24 V AC/DC
Temperature range –20 °C up to 70 °C
Humidity max. 95% (not condensing)

ORDER DESCRIPTIONS DIP SWITCH MODES

VEK M1H-A Induction loop detector (1-channel) The following functions can be adjusted:
VEK M2H-A Induction loop detector (2-channel) Sensitivity channel 1 step 1-4
Sensitivity channel 2** step 1-4
Frequency** low / high
Holding time 5 minutes / infinite
Relay operation principle* principle of rest / operation current
Status recognition** presence / direction
Relay output* presence signal / impulse signal
*only for VEM M1H
**only for VEK M2H

FUNKTION OF LED

LED green LED red Function

off off no power supply


flash off detector calibrates
on off detector operational, loop free
on on detector operational,
loop occupied
off on loop failure
FEIG ELECTRONIC reserves the right to change specification without notice at any time. flash on / off loop frequency as flashing signal
Stand of information: January 2012.

S-ar putea să vă placă și