Sunteți pe pagina 1din 7

PROPOSAL

ON
DESIGN, SUPPLY, INSTALLATION & COMMISSIONING
OF
1 KWP OFF GRID SOLAR PHOTO VOLTAIC ROOF TOP POWER PLANT
AT

Prepared by:
Electro Sales India
Rly Gate-2 Guwahati-781001
M- 9864203065.
Email- esi_powers@yahoo.co.in
electrosales20@gmail.com
Summary of Proposed 1KWP Solar Power Plant
SYSTEM DEFINITION

1. Location of Project Site :

2. Proposed Capacity of Solar Power Plant : 1KWp Off Grid Solar PV Roof Top Power Plant

Grid Interfacing: Solar system output shall be connected to a suitable load bus capable of taking the input.

SYSTEM COMPONENTS

Quantity =4 nos.
Wattage =250 Wp
Solar SPV Modules 250Wp. Make- Topsun Energy Ltd. MNRE Approved
Warranty Twenty FiveYears.

Quantity = 1 Nos
Inverter 2KVA/PCU AC Maximum power output = 2Kw
Maximum efficiency = >95%
Power Connection = Single Phase / Single Phase
Warranty – Two Years.

Quantity = 4 Nos.
Battery 12V,150Ah Voltage = 12 VDC,
Ampere Hour rating= 150 Ah
Make- Exide Industries Ltd.
Warranty- Five Years.

Cables will conform to IS 694 and shall be of 650 V/


1.1 kV grade. Interconnections, array to junction
boxes, junction to DCDB, DCDB to PCU etc. will be
selected to keep voltage drop and losses to the minim
um. The bright annealed 99.97% pure bare copper
conductors offer low conductor resistance; result in
Electrical Accessories lower heating thereby increasing cable life and
efficiency. These wires are insulated with a special
grade PVC, compound formulated and manufactured
in-house.

Working voltage: up to 1100 V


Temperature range: -15 deg C to +70 deg C
Sizes: Suitable sizes
Color codes: Red, Yellow, Black, Blue, Green
Assumption of Load Profile:
1. Technical:

1.1 Connected load of the Power Plant : 1.0 Kw

2. Battery Bank at each proposed locations

2.1 Battery Bank Capacity : 48 VDC; 150 AH


2.2 Selected battery : 12V; 150 AH
2.3 Nos. of days of use : 2 days (1 day use + 1 day autonomy)
2.4 Nos. of batteries required : 4 Nos.

3. PCU Size at each proposed locations

3.1 PCU capacity :1

+ KVA; 1 Phase; 48 VDC / 230 VAC 50 Hz.

4. OBJECTIVES

The proposed Solar PV Power Packs with an objective to attain following benefits:

- Providing uninterrupted power to the light points, Fans and computer for better communication & functioning of
the organization.
- Saving of precious fossil fuels.
- Noiseless, pollution free and Eco-friendly power.
- Saving of revenue.
- Can work as a demonstration project for further expansion of PV technology all over the country.

5. Area Required for Installation for 1KWP solar power plant:

The area required for installation of the plant is approximately

1 KW SPV Power Plant : 15 Sq. m (Approximately)

6. Location preferred for setting up SPV Array:

The above mentioned SOUTH FACING open space area should be available for setting up SPV Array for the
Proposed Power plants. The area should be complete shadow free without any sunlight obstruction like nearby tree
as well as tall building etc. Expose to stay at the settler direction should be absolutely clear.

Summary of 1 KWP SPV power plant with battery backup:

Capacity Nos. of module Nominal Nos. of Total nos. of Connected Daily Inverter Area
of power required voltage days of battery load of Watt- capacity required
plant of autonomy required power hour required for
power considered plant installation
plant
2KVA;
4Nos.
4Nos. 1.5 48 VDC/
1KWP 48VDC 2 day (12 volt; 150 15 Sq. m.
( 250Wp) KW 5kWh 230VAC
Ah)
50 Hz.
Schematic Diagrams:

Project configuration of 1 KWP SPV Power Plant with battery backup:

1KWp Solar Inverter: 1 KVA Load in kW or kWh:


Photovoltaic Array: As per load 5 kWh / Day

Battery Bank
Cell: 48 V/ 150 AH
Nos. of Cell: 4 Nos

ELECTRICAL

POWER CONTROLING UNIT

Nominal Battery voltage for battery backup power 48 volts DC


plant

AC output voltage 230 volt AC, 50 Hz

Maximum output capacity 1.0 KVA

Peak output capacity Up to 150% of maximum current for 15 seconds

Output wave shape Sine wave

THD <5%

Max current ripple 4% peak to peak

No load power consumption 2.5 % of O/p rating

Efficiency at 30 degree centigrade Up to a maximum of 85%


Working Pricipal:
Solar plant produces electricity to charge the battery bank connected as well as supply current to the load
connected with the system.

This system may be connected with the existing grid so that battery bank and the existing load could get the the
power on non sunny days.

PCU in this systems is of priority based which automatically sense the required priority.

a) 1st priority SOLAR means it will charge the battery bank and continue to supply current to the load if sun
intensity is sufficient as per
requirement.

b) 2nd priority is BATTERY means the battery bank will supply the current to the load connected in absence of
sun intensity.

c)3rd priority is GRID means the grid will supply the current for charging of the battery bank and the
connected load.
We may also change the priority if required as per site demand.

Advantages: a) Power may be obtained anytime may at daytime or even at evening as system is supported by
battery bank.
Protections:

Following protections shall be provided:


- Short Circuit
- Battery deep discharge/overcharge
- Overload
- Battery reverse polarity
- Input surge voltage

Project Duration:
The complete work of supply, installation and commissioning shall be in a period of 1 months once the sanction is
granted.
B. Bill of Material
The bill of material for SPV Power Plant is as under:

Sl No Description of item Unit Quantity

1 Solar PV Modules 250Wp Set 4 Nos.

2 Power Conditioning Unit 2KVA Nos. 01 Nos..

3 Array Junction Box Bus Bar No. 1 no.

4 MCB’s Set 1 Set.

5 Wires and Cables: 2.50 sq mm multistrand Set 50 mtrs x 2


6.0 sq mm multistrand 25 mtrs x 2

6 Isolator Set 1 no.

7 Structure For Module Set 1 no.

8 Rack for Battery Bank Set 1 no.

9 Battery Bank Set 4Nos.


(48VDC; 150 Ah) It depends on the capacity of the power
** for battery backup power plant plant.
Anexure III
Financial Aspects

Sl. Item description. Quantity. Amount.

1. 1 KWP SOLAR POWER GENERATING SYSTEMS. 1 set. 230000.00

(As per list of materials given. Annexure II )

230000.00

Amount In Words: Two lacs Thirty Thousand Only.


Anexure IV

Products Warranty And Other Terms & Conditions.


1. Items carry warranty for five Years Onsite. Solar Panels carrys warranty for Twenty
Five Years.

2. Defective Products will be service or replaced at free of cost at the warranty period
but the transportation cost of the materials shall be borne by the customer.

3. Warranty void if the products are tampered or been serviced by any unauthorized
person/s.

4. Maintenance of the systems including battery water topping , cleaning of solar


panels are at customer’s scope.

5. Hardware including cables, nut bolts, connectors and MS structure are not eligible
for warranty.

6. Payment Terms: i) Advance 40% along with confirm order.

ii) Balance 50% at the time of delivery.

iii) Remaining 10% after successful installation & commissioning.

7. Payment Mode By Bank : Bank of Maharastra


20152901977
IFSC – MAHB0001275
Branch- Lakhtokia Guwahati.

8. Company doesnot helds for responsibility of any kind of damage occurs due to
natural calamity.