Sunteți pe pagina 1din 54

1.

3 Typography A key part of our visual


language, these next
few pages explain
the best way to use
our typefaces correctly.

41
General Group-wide
Guidelines

40
Edition 1.1 August 2017 Edition 1.1 August 2017
Core Typeface
Kingspan
Brown.
Overview
Highly readable and legible;
Kingspan Brown is the core
typeface of our brand.
Humanist, timeless and with
a technical feel; it conveys
the qualities of our brand
across all of our touch-points;
infusing every aspect of what
we do with the Kingspan look
and feel.
It should be used on all external
facing communications -
from websites to brochures
and letterheads to adverts.
1.3.1
Core Typeface
1.3
Typography
Large
Headlines
Midsized
Headlines
Body Copy
Onsedi tem vellit vellabor
accuptas ipsam hil il molent
lacia simodi sit quia sam imus,
consequi consedi oreribusandi
vid molorep taererionsed
ma sam, que sit velissitiam
rem. Nem re officat iaspit,
audam volut este venihit labo.
Rionsequam solectur ma
volores molore mos audaese
nihici ideliquissi doloritatat.
Bit et, quo omnis re vel molo
qui volorporro magnihi
Body Copy
Onsedi tem vellit vellabor
accuptas ipsam hil il molent
lacia simodi sit quia creating
emphasis or highlighting text
sam imus, consequi consedi
oreribusandi vid molorep
taererionsed ma sam, que
sit velissitiam rem. Nem re
officat iaspit, audam volut
este venihit labo. Rionsequam
solectur ma volores molore
mos audaese nihici ideliquissi
doloritatat. Bit et, quo omnis
re vel molo qui volorporro
magnihi.
Kinspan Brown Thin
The elegant and crisp look
of Kinspan Brown Thin makes it
suitable for usage on as a title
typeface, large statements
in presentations or pull quotes
in editorial documents.
It works best at larger sizes,
however it is still important
to check with your printer about
reproduction of the font over
images. Use of tints in this
weight of Kingspan Brown
is not recommended as it
may lead to poor legibility.
It is not recommended for
use in body copy as it can be
difficult to read in small sizes.
Kinspan Brown Light
We should use Kinspan Brown
Light as our 'regular' typeface
and in all day to day marketing
communications. It is perfect
for usage in everything from
body copy, all headers, image
captions and technical text.
Kinspan Brown Regular
We should treat Kinspan Brown
Regular as our 'bold' weight.
It is reserved for headers and
sub-headers, however it can
be used if body copy is being
reversed out of an image or
dark coloured background.
1.3.2
Overview
1.3
Typography
Licensing
Kingspan Brown has been
licensed for usage by Kingspan
and any agency working with
the Kingspan brand must
obtain Kingspan Brown through
our marketing department.
Kingspan Brown cannot be
used in the creation of logos.
If in doubt about its usage,
please contact the Kingspan
marketing department.

43
Kingspan
Group Guidelines

42
Edition 1.1 August 2017 Edition 1.1 August 2017
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
abcdefghijklmnopq
rstuvwxyz 12345678
910 !@£$%^&**()_+
Kingspan
Brown Thin
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
abcdefghijklmnopq
rstuvwxyz 12345678
910 !@£$%^&**()_+
Kingspan Brown Thin, 10pt / 14pt
Kingspan Brown Thin Italic, 10pt / 14pt
Kingspan Brown Thin, 20pt / 24pt
Kingspan Brown Thin Italic , 20pt / 24pt
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
abcdefghijklmnopq
rstuvwxyz 1234567
8910 !@£$%^&**()_+
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
abcdefghijklmnopq
rstuvwxyz 1234567
8910 !@£$%^&**()_+
1.3.3
Kingspan Brown Thin
1.3
Typography
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
abcdefghijklmnopq
rstuvwxyz 12345678
910 !@£$%^&**()_+
Kingspan
Brown Light
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
abcdefghijklmnopq
rstuvwxyz 12345678
910 !@£$%^&**()_+
Kingspan Brown Light, 10pt / 14pt
Kingspan Brown Light Italic, 10pt / 14pt
Kingspan Brown Light, 20pt / 24pt
Kingspan Brown Light Italic, 20pt / 24pt
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
abcdefghijklmnopq
rstuvwxyz 1234567
8910 !@£$%^&**()_+
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
abcdefghijklmnopq
rstuvwxyz 1234567
8910 !@£$%^&**()_+
1.3.4
Kingspan Brown Light
1.3
Typography

45
Kingspan
Group Guidelines

44
Edition 1.1 August 2017 Edition 1.1 August 2017
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
abcdefghijklmnopq
rstuvwxyz 12345678
910 !@£$%^&**()_+
Kingspan
Brown Regular
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
abcdefghijklmnopq
rstuvwxyz 12345678
910 !@£$%^&**()_+
Kingspan Brown Regular Italic, 10pt / 14pt
Kingspan Brown Regular Italic, 10pt / 14pt
Kingspan Brown Regular, 20pt / 24pt
Kingspan Brown Regular Italic , 20pt / 24pt
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
abcdefghijklmnopq
rstuvwxyz 1234567
8910 !@£$%^&**()_+
ABCDEFGHIJKLMN
OPQRSTUVWXYZ
abcdefghijklmnopq
rstuvwxyz 1234567
8910 !@£$%^&**()_+
1.3.3
Kingspan Brown Regular
1.3
Typography
Century
Gothic
Supporting
Typefaces
Non-Western Language Support
Additional language support
is currently in development
for Kingspan Brown.
Whilst this development takes
place, we should use Noto Sans
as an alternative. It is an open
source typeface currently being
developed by Google.
Noto Sans covers 30 language
scripts and in the future,
will cover all Unicode.
There may be some instances
where it isn't possible to use
Kingspan Brown for technical
reasons or because of an
unsupported language script.
In these instances only, we
should use the typefaces set
out below.
Backup Font
There may be some instances
where it isn't possible to use
Kingspan Brown for technical
reasons; such as an internal
system where a typeface
cannot be installed, or because
Kingspan Brown is not available
in a particular language.
In these instances, we should
revert to using Century Gothic.
Century Gothic is pre-installed
on all Windows and Mac OS
operating systems.
It should not be used as
a substitute for Kingspan
Brown in brochures, websites
or merchandising, unless as
previously stated Kingspan
Brown is not available for
a technical reason.
Languages
Scripts
Please visit
google.com/
get/noto/
for a full list
of available
language scripts.
Languages
Scripts
Latin
Eastern Europe
Cyrillic
Greek
Turkish
1.3.4
Supporting Typefaces
1.3
Typography

47
Kingspan
Group Guidelines

46
Edition 1.1 August 2017 Edition 1.1 August 2017
Typesetting
Best Practice
Temodit aut demporem
num etum nonserum la
idit aut exces rem aut
voluptas aut faccae dera
ipiduntin nis enimporem
es nonsequ oditinimolum
nulparcit aribero id eum
quatissit voluptaerat que.
Paying attention to how we
set our type can make a real
impact on how our information
is interpreted by our audience.
As a general rule, we should
always make sure our text
collumns are neat, not using
hyphenation and avoiding
leaving a single word on a line
at the bottom of a paragraph.
Alignment
We should always set type so
the ragged edge is on the left
of the block.
This makes type easier to read,
as there is a consistent starting
point for the eye to follow.
We should also avoid breaking
words over two sentence or
leaving one word "hanging"
on its own on a line.
1.3.5
Typesetting
1.3.5
Typesetting
1.3
Typography
1.3
Typography
Temodit aut
demp orem num
etum nonserum
la idit aut exces.
20pt / 22pt.
Temodit aut demp
orem num etum
nonserum la idit aut
exces rem. 14pt / 16pt.
Temodit aut demporem
num etum nonserum la
idit aut exces. 8pt / 10pt.
Leading & Baseline Grid
Leading is the space between
lines of type.
To help calculate leading easily
and keep blocks of type aligned
correctly; we use a 2pt baseline
Grid across our documents.
If you are not using a baseline
grid, calculate the leading
size by adding 2p to the point
size of your type.
Depending on the context,
there may be instances when
a greater or lesser amount of
leading is needed, so feel free
to adjust accordingly.
Kerning & Tracking
Kerning refers to the space
between individual letters
of a word, whilst tracking
is the space between a whole
group of words.
On occasion, you may need
to adjust the tracking of a line
of text to fit into a given space,
however you should be careful
not to impair legibility.
All typography should be set
with Optical kerning.
Optical kerning, 0 Tracking Optical kerning, -25 Tracking
Bistest quiate nonsequate
et fugiae am, ipsam quas
ut ent officid millanto estis
earchit aquosa et ea nobis
audae rerat lignimusto etur
ma doles ium reriossusci aut
exerio et ped que explique
rem expel idunde perum
tem etur, corpore et pliatem
quatquis ad quissim olorpor
empostrum inveri dolum ex
ex et optatecabor as volupta
temquis perchil idiciandam,
sinciis doluptas vendi as is aut
offic tem harum quam.
Bistest quiate nonsequate et
fugiae am, ipsam quas ut ent
officid millanto estis earchit
aquosa et ea nobis audae rerat
lignimusto etur ma doles ium
reriossusci aut exerio et ped
que explique rem expel idunde
perum estem etur, corpore et
pliatem quatquis ad quissim
olorpor empostrum inveri
dolum ex ex et optatecabor
as volupta temquis perchil
idiciandam, sinciis doluptas
vendi as is aut offic tem
harum quam.

49
Kingspan
Group Guidelines

48
Edition 1.1 August 2017 Edition 1.1 August 2017
Reversing out
If type is reversed out of an
image or colour background;
we should pay attention to the
weight of the type to ensure
that it does not 'break down'
at small sizes.
The top example shows Kingspan
Brown Regular used against
a grey background.
The bottom demonstrates
Kingspan Brown Light. As you
can see, at the smaller sizes,
parts of the characters become
difficult to distinguish.
There is no 'hard rule' here -
so you must use your discretion
when selecting the right weight
for your design.
Temodit aut
demp orem num
etum nonserum
la idit aut exces.
20pt / 22pt.
Temodit aut
demp orem num
etum nonserum
la idit aut exces.
20pt / 22pt.
Temodit aut demp
orem num etum
nonserum la idit
aut exces rem.
Sed efficitur ante ut
tempor consequat.
14pt / 16pt.
Temodit aut demp
orem num etum
nonserum la idit
aut exces rem.
Sed efficitur ante ut
tempor consequat.
14pt / 16pt.
Temodit aut demporem
num etum nonserum la
idit aut exces. 8pt / 10pt.
Temodit aut demporem
num etum nonserum la
idit aut exces 6pt / 8pt.
Temodit aut demporem
num etum nonserum la
idit aut exces. 8pt / 10pt.
Temodit aut demporem
num etum nonserum la
idit aut exces. 6pt / 8pt.
1.3.5
Typesetting
1.3.5
Typesetting
1.3
Typography
1.3
Typography
Type with Image
When using typography over
an image we should ensure
the composition is balanced
and that the type does not
impede on the focus point
of the image and the text
remains readable.
Type over an image should only
ever be set in white or dark grey.
Coloured type should not be used
on top of imagery.
Temodit aut demporem
num etum nonserum la
idit aut exces. 8pt / 10pt.
Temodit aut
demp orem num
etum nonserum
la idit aut exces.
20pt / 22pt.

51
Kingspan
Group Guidelines

50
Edition 1.1 August 2017 Edition 1.1 August 2017
Hierarchy
& Emphasis
Headline
92pt Subhead 60pt
Body Copy 30pt
Technical Information 10pt
We can create hierarchy
and emphasis through by
using different type styles.
These should be clear
and consistent to allow
for information to be
digested quickly and
easily by our audience.
The examples here are
a guide, and each usage will
require its own treatment.
Dramatic changes
in point size can
establish hierarchy.
1.3.5
Hierarchy & Emphasis
1.3.5
Hierarchy & Emphasis
1.3
Typography
1.3
Typography
Headline 60pt
Subhead 30pt
Body Copy 10pt
Technical Information 10pt
Headline 60pt
Subhead 60pt
Body Copy 10pt
Technical Information 6pt
Headline 30pt
Subhead 30pt
Body Copy 30pt
Technical Information 30pt
At smaller point
sizes, a subtle
colour change
can work to
denote hierarchy.
Alternatively, we
can also change the
weight of type used.
A colour change
can look clean
and sophisticated.

53
Kingspan
Group Guidelines

52
Edition 1.1 August 2017 Edition 1.1 August 2017
1.4 Presentation
Templates
You must use the
correct master template
as Kingspan Brown
is embedded into it.
This means that even
users who do not have
Kingspan Brown on
their machines, will be
able to edit it with the
correct font.

55
General Group-wide
Guidelines

54
Edition 1.1 August 2017 Edition 1.1 August 2017
Presentation
Grid
Internal and external
presentations should be
created at 1025 px x 769 px,
standard size in Microsoft
PowerPoint and Apple's
Keynote software.
Presentation Grid
1025 px x 769 px
The presentation
grid includes a date
and titling system
at the header.
The presentation
grid uses a 6 column
underlying grid
to combine text
and images.
Rules & Tools Rules & Tools

56

Layout Layout 57
Edition 1.1 August 2017 Edition 1.1 August 2017
Templates
Kingspan Wastewater
Management Solutions
Product Guide
Lorem Ipsum Dolor
Ferume non re nis et que qui
nonsedi psusdantur? Ipsaeprovit
apictibusa poribus ad ut optur
ra simpossume voluptatem
yards.
Infrastructure
PP.57.66
03

15
Cylindrical Bunded Tanks

8
Lorem Ipsum Dolor
• Ferume non re nis et que qui nonsedi
psusdantur? Ipsaeprovit apictibusa poribus
ad ut optur ra simpossume voluptatem
yards.
• Itatibus es sequae con pressequi bea
dolesciur, aut rentissitae cor suntiaspic tent.
Nam, aut reptatem imod etusaperum
quiamentio qui de vendiatur ma
voluptaturem quam, cum eum abo.
Peligendae dipsum remoluptae.
• Ferume non re nis et que qui nonsedi
psusdantur? Ipsaeprovit apictibusa poribus
ad ut optur ra simpossume voluptatem
• Ferume non re nis et que qui nonsedi
psusdantur?
• Nam, aut reptatem imod etusaperum
quiamentio qui de vendiatur ma?
• sequae con pressequi bea dolesciur, aut
rentissitae cor suntiaspic tent. Nam, aut
reptatem imod etusaperum quiamentio qui
de vendiatur
• sIpsaeprovit apictibusa poribus ad ut optur ra
simpossume voluptatem
Tank
Dimensions
Maximum Dimensions
cabinets
Product Code/
Capacity
Length Width Height Footprint Max
Length
Max
Height Weight
DP5000CB 2.52m 2m 2m 2.52m x 2m 3.07m 2.3m 2200kg
DP10000CB 4.03m 2m 2m 4.03m x 2m 4.6m 2.3m 2750kg
DP15000CB 5.6m 2m 2m 5.6m x 2m 6.15m 2.3m 2990kg
DP20000CB 4.8m 2.5m 2.5m 4.8m x 2.5m 5.35m 2.82m 4900kg
DP30000CB 7.3m 2.5m 2.5m 7.3m x 2.5m 7.85m 2.82m 6800kg
DP44000CB 8.6m 2.75m 2.75m 8.6m x 2.75m 9.22m 3.05m 7800kg
DP53000CB 10.3m 2.75m 2.75m 10.3m x 2.75m 10.85m 3.05m 8700kg
DP62000CB 12m 2.75m 2.75m 12m x 2.75m 12.55m 3.05m 10400kg
Cylindrical Bunded
Tanks

19
Section 2 Lorem Ipsum
Dolor

18
Lorem Ipsum
Lorem Ipsum
South East
Lorem Ipsum
Lorem Ipsum
Lorem Ipsum Lorem Lorem Ipsum
Global
Expansion Lorem Ipsum
Lorem Ipsum
South East
Lorem Ipsum
Lorem Ipsum
Lorem Ipsum Lorem Lorem Ipsum
Applications For
Commercial Pumping
Stations Range:
· Housing developments.
· Large commercial
developments.
· Industrial developments.
· Caravan/camping sites.
· Schools.
· Hotels and restaurants.
· Nursing homes.
· Attenuated water.
40 years’ experience
designing and
manufacturing diesel
tank solutions
Location
Sydney, Australia
AU
“Hendi dolupti cum fugition re aditae nimi,
optat et pore dolorum ut dit”
–— Lorem Ipsum, Dolor Licipsus sit
Powerpoint Template Options
Rules & Tools Rules & Tools

58

Layout Layout 59
Edition 1.1 August 2017 Edition 1.1 August 2017
Templates
Powerpoint Template Options
For the master
template, check out
the Brand Guidelines
folder on NetX.
Rules & Tools Rules & Tools

60

Layout Layout 61
Edition 1.1 August 2017 Edition 1.1 August 2017
Section 2:
Kingspan
Insulated Panels
Visual Guidelines

63
General Group-wide
Guidelines

62
Edition 1.1 August 2017 Edition 1.1 August 2017
Brand Positioning
and Themes
High Performance Buildings
for a Low Energy Future
Kingspan Insulated Panels is a €1.5bn division
within the Kingspan Group, a manufacturer
of sustainable and affordable best practice
solutions for the global construction sector.
We believe in advancing construction speed
and safety, enabling a low energy future
and transforming our built environment to be
healthier and more attractive. That’s what
drives us to invest continuously in innovation
and knowledge.
From QuadCoreTM, our next generation
insulated panel core, to advanced building
energy modeling, we bring the latest
technologies and services to create more
value for our customers and partners.
Our complete insulated panel systems for
roof, wall and facade are backed byextensive
testing and guarantees, while being supported
by friendly service and a world of practical
know-how that comes from a family business
with 50 years of building better.
These four themes are driving our Insulated Panels
positioning strategy and should be applied as
appropriate in your market and woven through
customer touchpoints.
04 —
Architectural
Versatility
02 —
Innovation &
Building Science
01 —
Service &
Support
03 —
Systems &
Warranties
Strategy Strategy

64

Brand Positioning and Themes Brand Positioning and Themes 65
Edition 1.1 August 2017 Edition 1.1 August 2017
Core Assets Logo
Primary
Colour Palette
Secondary
Colour Palette
Grid Documents
Typeface
Kingspan Brown
Building Envelope
Systems & Solutions Guide
Insulated
Panel
Systems

Middle East
Africa
Turkey
Central Asia
India
Insulated Panel Roof and Wall Systems, Facade and Rainscreen Systems,
Specialist Fabrications, Lighting, Renewable Technologies.
Illustration Product Renders
Icons & Nodes
Photography
General Group-wide
Guidelines

66

Core Assets Core Assets 67
Edition 1.1 August 2017 Edition 1.1 August 2017
Brochure
Architecture
& Covers
The Group will move to the
same formats for brochures
so that when they appear
side by side, no matter
what division they are from,
there will be consistency.
We are allowing more
flexibility in Insulated Panels
than some other divisions
for internal layouts.
Brand in Action Brand in Action

68

69
Edition 1.1 August 2017 Edition 1.1 August 2017
Brochure
Architecture
Global Project Showcase 70 Inspirational Projects 2016 Edition
Topdek
Membrane Flat Roof
System Guide
Insulated Panels / Rooighting / Fabrications / Rooftop Solar PV
Insulated Panel Systems
UK & Republic of Ireland
QuadCore
RW Pitched Roof
System Guide
Insulated Panels / Daylighting / Solar PV /
Fabrications / Gutters / Saftey Systems
Insulated Panel Systems
UK & Republic of Ireland
QuadCore
Architectural Wall Panel
System Guide
Insulated Panels / Rooighting / Fabrications / Rooftop Solar PV
Insulated Panel Systems
UK & Republic of Ireland
Building Envelope
Systems & Solutions Guide
Insulated Panel Roof and Wall Systems, Facade and Rainscreen Systems,
Specialist Fabrications, Lighting, Renewable Technologies.
Insulated Panel Systems
Middle East
Africa
Turkey
Central Asia
India
Cleanroom Systems
Global Case Study Book
High Performance Systems Including Walls,
Windows, Doors and Ceilings
Controlled Environments
UK & Republic of Ireland
Specialist Fabrications
Products & Services Guide
Architectural Features & Cladding Components
Insulated Panel Systems
UK & Republic of Ireland
Corporate
Corporate pieces, such as the
annual Be Inspired book or the
Sustainability Report, will have
a bespoke design but will still
follow the brand guidelines.
Product Selector Case Study Books
Corporate
Panel System Guides
We are moving to presenting
systems rather than panels,
therefore we should choose
photographs that show a
number of system components
(fabrications, lighting etc)
as well as the installed panel
system. We are sadly lacking
in this photography now, but
we need to focus on building
up a bank of system photography
for the future.
Be careful to use blocks of colour
underneath the text areas
for legibility.
We want a bright, sunny, natural
feel to our cover images.
Non-QuadCore
QuadCore
Systems & Solutions Guides, Non QuadCore QuadCore
Case Study Books
This format is intended for:
Our product selector (to be
renamed as a Building Envelope
Systems & Solutions Guide).
Brochures that contain collections
of products e.g. Daylighting,
Fabrications Case study books
for business units.
This format should have a
very visually descriptive set of
photographs on the front cover,
showing a relevant selection
of systems, applications
and building types.
Datasheets
QuadCore
Trapezoidal RW
Data Sheet
Insulated Panel Systems
UK & Republic of Ireland
Architectural
Wall Panel
Data Sheet
Insulated Panel Systems
UK & Republic of Ireland
Product feature
Product feature
Product feature
Product feature
Brochure Architecture & Covers Brochure Architecture & Covers
Brand in Action Brand in Action

70

71
Edition 1.1 August 2017 Edition 1.1 August 2017
We use a range of formats
throughout our printed
marketing communications.
Each format uses a set cover
template, bringing a uniformity
and consistency throughout the
documents we produce.
Our brochure layout has been
designed to work at each format.
A4 Portrait A4 Landscape
Document
Formats
Brochure Architecture & Covers Brochure Architecture & Covers
DL A5 Portrait A5 Landscape
Brand in Action Brand in Action

72

73
Edition 1.1 August 2017
Edition 1.1 August 2017
Brochure
Architecture
A4 Portrait Margin
Area & Gutters
297mm
210mm
Margins
All A4 documents have a uniform margin are
20mm on all four sides – highlighted in blue.
20mm
Gutters and Horizontal Dividing Lines
Both the vertical and horizontal gutters / spaces are exactly 4mm wide.
4mm
4mm
Brochure Architecture & Covers
Brand in Action

74
Brand in Action

75
Edition 1.1 August 2017
Edition 1.1 August 2017
Brochure
Architecture
A4 Portrait Margin
Area & Gutters
Grid Rectangles
of 8 rectangles wide x 17 rectangles high. Each rectangle is approximately
17.75mm x 11.353mm in size.
17.75mm
11.353mm
297mm
210mm
Brochure Architecture & Covers
Brand in Action

76
Brand in Action

77
Edition 1.1 August 2017
Edition 1.1 August 2017
Brochure
Architecture
Front Cover
Brochure name as per NetX guidelines
Brochure Architecture & Covers
Product Portfolio
Systems and
Solutions Guide
Insulated Panels / Daylighting / Fabrications / Rooftop Solar
Insulated Panel Systems
UK &
Republic of Ireland
Designated Image Area
The image area for Case Study / Product Portfolio literature is positioned
starting vertically from the sixth grid rectangle.
Image Size
6 grid rectangles wide x 9 grid rectangles high.
Image Grid Flexibility
The Designated Image Area utilised by multiple images: number
and proportions are to suit images required. Individual image areas
are determined by grid rectangles. Space between images is 4mm,
horizontally and vertically.
Technology / Secondary Logos
Fixed position is the logo baseline on the bottom left grid square.
Kingspan Logo
Width: 48mm.
Fixed position is the logo baseline on the bottom right grid square.
Brochure Sub-Title
Typeface: Kingspan Brown Light
Colour: CMYK: 65 / 57 / 52 / 68
Size: 14pt
Leading: 16.8pt
Kerning: Optical
Tracking: Zero
Grid Position
Vertically align with the top of the 6th grid rectangle.
HLPG & Location
Typeface: Kingspan Brown Regular / Kingspan Brown Light
Colour: CMYK: 65 / 57 / 52 / 68
Line Weight: 0.3pt
3mm
Size: 8pt
Leading: 10pt
Kerning: Optical
Tracking: Zero
Grid Position
Vertically align with the top left grid rectangle.
Line length always matches the longest wording line.
48mm
Insulat
PV
Kingspan Insulated Panels: Case Study / Product Portfolio Main Title
Typefaces: Kingspan Brown Light / Kingspa n Brown Thin
Colour: CMYK: 65 / 57 / 52 / 68
Size: 36pt
Leading: 38pt
Kerning: Optical
Tracking: Zero
Grid Position
Vertically align with the top of the 3rd grid rectangle. Pr Warranty Tab
Size: 30.5mm wide x 45mm deep including 5mm bleed to top.
Grid Position
Fixed position is the tab right hand edge on the right hand edge
of the 8th grid square horizontally.
Brand in Action

78
Brand in Action

79
Edition 1.1 August 2017
Edition 1.1 August 2017
Brochure
Architecture
Front Cover
Brochure Architecture & Covers
Trapezoidal RW
Pitched Roof
System Guide
Insulated Panels / Daylighting / Fabrications / Rooftop Solar PV
Insulated Panel Systems
UK & Republic of Ireland
Designated Image Area
The Designated Image Area for System Guide literature is to suit one
‘hero’ image, positioned starting horizontally 10mm from the left edge,
running to bleed at top and right of page, and aligned with the baseline
of the 14th grid rectangle vertically.
205mm wide x 235.942mm high, including 5mm bleed at top and right.
Technology / Secondary Logos
Fixed position is the logo baseline on the bottom left grid square.
Kingspan Logo
Width: 48mm.
Fixed position is the logo baseline on the bottom right grid square.
Brochure Sub-Title
Typeface: Kingspan Brown Light
Colour: White / Paper (if image allows)
CMYK: 65 / 57 / 52 / 68
Size: 14pt
Leading: 16.8pt
Kerning: Optical
Tracking: Zero
Grid Position
Vertically align with the top of the 6th grid rectangle.
Warranty Tab
Size: 30.5mm wide x 45mm deep including 5mm bleed to top.
Grid Position
Fixed position is the tab right hand edge on the right hand edge
of the 8th grid square horizontally.
HLPG & Location
Typeface: Kingspan Brown Regular / Kingspan Brown Light
Colour: White / Paper (if image allows)
CMYK: 65 / 57 / 52 / 68
Line Weight: 0.3pt
3mm
Size: 8pt
Leading: 10pt
Kerning: Optical
Tracking: Zero
Grid Position
Vertically align with the top left grid rectangle.
Line length always matches the longest wording line.
48mm
Kingspan Insulated Panels: System Guide Main Title
Typefaces: Kingspan Brown Light / Kingspa n Brown Thin
Colour: White / Paper (if image allows)
CMYK: 65 / 57 / 52 / 68
Size: 36pt
Leading: 38pt
Kerning: Optical
Tracking: Zero
Grid Position
Vertically align with the top of the 3rd grid rectangle.
Brand in Action

80
Brand in Action

81
Edition 1.1 August 2017
Edition 1.1 August 2017
Brochure
Architecture
Back Cover
Brochure name as per NetX guidelines
Insert name of document,
above the date of publication,
as it appears on the website
Brochure Architecture & Covers
05/2017
UK
Kingspan Limited
Gree
eld Business Park No.2
eld, Holywell
7GJ
kingspanpanels.Ireland
Kingspan Limited
Carrickmacross Road
Kingscourt, Co.Cavan
420969 kingspanpanels.ering in other markets
contact your representative
or visit
www.kingspanpanels.com
Care has been taken
to ensure that the contents of this publication
accurate, Kingspan subsidiary responsibility information misleading. Suggestions description
products working are Kingspan thereof.
pan No olyw
8
7G
T: +44 (0) 1352
716100
F: +44 (0) 1352
710161
npa
C i k ss R d
o.C
096
F: +353 (0) 420969 8572
ki npa l i
c
er m
ct yo rep
king om
C
h
bkn
e h h tents f h bl
ngsp subsid
bility orma
ugges tion
p ucts o ng a
ngspan Limited and its subsidiaries accept no liability in
reof
an Lim d
ess well
GJ
6100
e Bus
Gree Ho
Flintshire, CH8
0161
anels.co.uk
www.kingspan
nd
i Li d
avan
9 8500
9 Carrickmacros
Co
T: +353 (0) 420
F 420
www.kingspan anels.ie
presentative
othe
our local sales
spanpanels.co
produc
contac
sit k
diary companies do
tion that is found
of, the end use or
re for information
cont
pan Limited and its s
y for errors or for info
stions for, or descrip
or methods of worki
re urate, but Ki
t responsi
ading. Su
of produ
ereof.
w
G
Go
a
wn
Ki
a
69 s
o
T0
wnak
p
he
o
o
dc
hi bli i
d
a
t
po
sp
u
ereof
Kingspan Logo
Width: 48mm.
Fixed position is the logo baseline on the bottom right grid square.
Main Column Headings
Typeface: Kingspan Brown R egular
Colour: CMYK: 65 / 57 / 52 / 68
Size: 11pt
Leading: 14pt
Kerning: Optical
Tracking: Zero
Line Weight: 0.3pt
7mm
Space Before: 4.5mm
Grid Position
Always align with the top of the 3rd grid rectangle
Vertically align each individual country heading
to a grid rectangle
Kingspa
K
Irelan
pp
only and Kin
respect the
are accur
not accept
to be mislea
application o
a
t
For the p
please c
Fh
o
NB / Footnote Copy
Typeface: Kingspan Brown Light
Colour: CMYK: 65 / 57 / 52 / 68
Size: 5.5pt
Leading: 7pt
Kerning: Optical
Tracking: Zero
Space After: 1mm
Generic Product Copy
Typeface: Kingspan Brown Light
Colour: CMYK: 65 / 57 / 52 / 68
Size: 8pt
Leading: 11pt
Kerning: Optical
Tracking: Zero
Grid Position
Always align with the top of the 15th grid rectangle
48mm
Brand in Action

82
Brand in Action

83
Edition 1.1 August 2 May 2017017 Edition 1.1 MAuagyu 2s0t 127017
Brochure
Internal Grids
& Layouts
You must follow the
fundamental setup of
the internal grids in terms
of margins and gutters,
but after that you are free
to mix and match internal
templates as you see fit.
We have included examples
of recommended layouts
but feel free to be creative!
Brand in Action Brand in Action

84

85
Edition 1.1 August 2017
Edition 1.1 August 2017
Brochure
Architecture
Internal Spread A4
297mm
210mm
Margins
All A4 documents have a uniform margin area
of 20mm on all four sides – highlighted in blue.
20mm
Gutters and Horizontal Dividing Lines
Both the vertical and horizontal gutters / spaces are exactly 4mm wide.
4mm
4mm
297mm
210mm
4mm
4mm
297mm
Brochure Internal Grids & Layouts
Brand in Action

86
Brand in Action

87
Edition 1.1 August 2017
Edition 1.1 August 2017
Product Insulated Wall Panel Systems Insulated Wall Panel Systems
Portfolio
Product
Portfolio
23 24
Brochure
Architecture
Internal Spread A4
Page Numbers/Folio Headers
Typeface: Kingspan Brown Light
Size: 8pt
Colour: CMYK: 65/57/52/68
Brochure Internal Grids & Layouts
Brand in Action

88
Brand in Action

89
Edition 1.1 August 2017
Edition 1.1 August 2017
Brochure
Architecture
2 Column Grid
For all Kingspan Insulation A4 portrait literature internal page layouts,
Each column sits within the grid / margin area and is sized 83mm wide
x 257mm depth.
All text and image components sit within this column.
For Kingspan Insulated Panels A4 portrait literature internal page
83mm
257mm
Brochure Internal Grids & Layouts
Brand in Action Brand in Action

90

91
Edition 1.1 August 2017 Edition 1.1 August 2017
Internal Grids
3 Insulated Wall Panel Systems Insulated Wall Panel Systems 4
Insulated
Wall Panel
Systems
01
11
05
32
08
65
Trapezoidal
Wall Panel Systems
Ultra-Smooth
Wall Panel System
Kreate
Integrated Façade System
Architectural
Wall Panel Systems
Premium
Wall Panel Systems
Dri-Design Dry Joint
Metal Façade System
Product
Portfolio
Product
Portfolio
Section Intro Spread options
5 Insulated Wall Panel Systems Insulated Wall Panel Systems 6
Insulated
Wall Panel
Systems
01
11
05
32
08
65
Trapezoidal
Wall Panel Systems
Ultra-Smooth
Wall Panel System
Kreate
Integrated Façade System
Architectural
Wall Panel Systems
Premium
Wall Panel Systems
Dri-Design Dry Joint
Metal Façade System
Product
Portfolio
Product
Portfolio
Brand in Action Brand in Action
— 92

Brochure Internal Grids & Layouts Brochure Internal Grids & Layouts 93
Edition 1.1 August 2017 Edition 1.1 August 2017
Internal Grids
Hero Spread Options
7 Insulated Wall Panel Systems Insulated Wall Panel Systems 8
Lorem
ipsum dolor
sit amet
Lorem ipsum dolor sit amet,
consectetur adipiscing elit,
sed do eiusmod tempor
incididunt ut labore et
dolore magna aliqua. Ut
enim ad minim veniam, quis
nostrud exercitation ullamco
laboris nisi ut aliquip ex ea
commodo consequat.
Product
Portfolio
Product
Portfolio
Lorem ipsum dolor sit amet,
consectetur adipiscing elit,
sed do eiusmod tempor
incididunt ut labore et
dolore magna aliqua. Ut
enim ad minim veniam, quis
nostrud exercitation ullamco
laboris nisi ut aliquip ex ea
commodo consequat.
9 Product Insulated Wall Panel Systems Insulated Wall Panel Systems 10
Portfolio
Product
Portfolio
Lorem
ipsum dolor
sit amet
Brand in Action Brand in Action

94

Brochure Internal Grids & Layouts Brochure Internal Grids & Layouts 95
Edition 1.1 August 2017 Edition 1.1 August 2017
Internal Grids
Hero Spread Options
Trapezoidal
Wall Panel System
13 Product Insulated Wall Panel Systems 14
Portfolio
Insulated Wall Panel Systems Product
Portfolio
17 Product Insulated Wall Panel Systems 18
Portfolio
Insulated Wall Panel Systems Product
Portfolio
Trapezoidal
Wall Panel
System
01
Dandirri Contact Centre
Australia
02
Gazeley Properties
UK
03
Brookfield Park
UK
04
Arigna Coalmine Visitor Centre
Ireland
05
Ski Centre, Queenstown
New Zealand
Clockwise from left
Trapezoidal
Wall Panel
System
Dri-Design is a dry joint
metal façade system
that provides nearly endless
design possibilities,with an
unlimited palette of colours,
finishes, materials, textures
and custom perforations.
01
Dandirri Contact Centre
Australia
02
Gazeley Properties
UK
03
Brookfield Park
UK
04
Arigna Coalmine Visitor Centre
Ireland
05
Ski Centre, Queenstown
New Zealand
Clockwise from left
15 Product Insulated Wall Panel Systems 16
Portfolio
Insulated Wall Panel Systems Product
Portfolio
Brand in Action Brand in Action

96

Brochure Internal Grids & Layouts Brochure Internal Grids & Layouts 97
Edition 1.1 August 2017 Edition 1.1 August 2017
Internal Grids
Introduction Spread
1 Introduction Introduction 2
Introducing
QuadCore
It’s all in the grey cells...
QuadCore technology is Kingspan’s
next generation of self-blended hybrid
insulation core.
Across the world of insulated panels,
this innovation with its distinctive
grey microcells powers the industry’s
highest overall performance.
20%
Thermal performance
enchanceement
Thermal and
structural guarantee
Superior fire
protection
Route to
Net-Zero-Energy
buildings.
40yr
Fire Zero
This scientific breakthrough has led
to a completely new core material
for our insulated panels that delivers
the industry’s highest thermal
performance, superior protection and
enhanced environmental credentials.
Technology decisions made today
can impact the value of property
tomorrow. That’s why our building
performance team will be with you
every step of the way.
We help you navigate the complexities
of a changing legislative landscape
and a competitive property market.
We also bring our expertise in
‘whole building analysis’ to bear
on maximising the return on your
building envelope investment.
All backed by peace of mind and a
unique 40 year thermal and structural
guarantee that’s unrivalled among
advanced building systems.
The journey starts here.
The development of
QuadCore is a quantum
leap on the journey
to high-performance
buildings that are better
for the environment
and for business.
Kingspan’s most
important technology
breakthrough of
the 21st century.
QuadCore technology
is rolling out across the
world into the full range
of Kingspan Insulated
Panel systems for roofs,
walls and façades.
Contact your local sales
office for information
about specification
and availability.
Product
Portfolio
Product
Portfolio
Brand in Action Brand in Action

98

Brochure Internal Grids & Layouts 99
Edition 1.1 August 2017 Edition 1.1 August 2017
Internal Grids
Technical Information Spread Options
19 Product Insulated Wall Panel Systems Insulated Wall Panel Systems 20
Portfolio
Product
Portfolio
Architectural
Wall Panel Systems
KS600-KS1000
Product Highlights
Architectural Wall Panels and
Longspan Architectural Wall
Panels (same profile as AWP
but with a greater spanning
capability) are secret-fix wall
panel systems that offer
unprecedented freedom of
design and top-of-the-range
performance to architects.
Available in 11 distinct profiles,
these systems allow architects
to look beyond traditional
insulated panel designs to
create buildings with more
inspiring façades at an
affordable cost to the client.
Compatible With
– Day-Lite Architectural
Systems
See page 114
– Specialist Fabrications
See page 108
– Integrated Preformed
Corners
see page XX
– Wide Range of Top Hat
Profiles
see page XX
Key Benefits
– Accelerated build speed
through pre-engineered,
single component, single-fix
installation.
– Most are available in
cover widths from 600-
1000mm in as low as 1mm
increments depending on
the profile.
– Wide range with lengths
from 1.8m up to 13m,
suitable for vertical or
horizontal application.
– Huge flexibility with
simple integration with
doors, windows, glazing,
louvres and traditional
construction materials.
– Architecturally enhancing
ancillary package available,
including pre-formed corner
and curved units.
All AWP products are available in cover
widths 600mm, 900mm and 1000mm
as standard. Other width variations
are available subject to minimum order
quantity.
Please note that the product codes
shown above are for AWP only.
Longspan product codes are the same
as AWP, but with the inclusion of
‘Longspan’ before the profile code e.g.
KS600-1000 Longspan MR.
Details
Profile
Fixing Detail
Metal Type
Colours
Coatings
Applications
Lengths
Cover Width
Spanning
Capacity
Environmental
Rating
Fire Rating
Product
Compatibility
Preformed
Corners
and Panels
Seals
Curvewall, Convex,
Euro-Box, Flat, Flat-Stucco,
Louvre, Mini-Micro,
Micro-Rib, Plank, Tramline,
Wave
Secret-fix
Steel or aluminium
Please refer to colour
charts for the
coatings listed below
Kingspan XL Forté
(Symphony / Vivace /
Crescendo), Kingspan
Spectrum (Solid / Metallic /
Diamond), Kingspan Altaris
and Kingspan Textured.
Curvewall in Kingspan
Spectrum Metallic (Silver
only). Louvre in Kingspan
XL Forté Symphony
(Goosewing Grey / Bottle
Green only) and Kingspan
Spectrum Solid and
Metallic (Onyx / Silver /
Obsidian only). Please
note, Flat is only available
in Kingspan XL Forté
and Flat-Stucco is only
available in
Kingspan Spectrum
Suitable for vertical or
horizontal
application
From From 1.8m up to 13m
From 600mm to 1000mm,
available in increments
from as low as 1mm
subject to minimum order
requirements and is profile
dependent*
Longspan – up to 8,2m,
frame to frame
Green Guide A+ rating
as per the BRE Global
“The Green Guide to
Specification”, Green
Guide 2008 ratings (applies
to AWP CX, EB, FL, MM,
MR and WV, in 600mm,
900mm and 1000mm cover
widths only)
LPCB** approved, FM
approved (AWP 900mm
and 1000mm cover
widths only)
All profiles integrate
with each other, as
well as with Optimo
and Kingspan Day-Lite
Architectural (AWP
only)
Panels can be curved on
the length or width,
corners can be cranked
or and Panels: mitred
depending on profile
Factory-applied side
weather seal
Specifications
and Accreditations
KS600–1000
MR/EB/FL/FL-S/MM
/ CX/WV/PL and
KS1000 TL/CW/LV
KS600–1000
Longspan
MR/EB/FL/FL-S/
MM CX/WV/PL and
KS1000 TL/CW/LV
Standard
Environement
Temp Control
Hygine
High Humitiy
Low Temp
Fire Rating LPCB
Fire Rating FM
Convex
KS600-1000 CX
Flat-Stucco
KS600-1000 FL-S
Wave
KS600-1000 WV
Micro-Rib
KS600-1000 MR
Euro-Box
KS600-1000 EB
Louvre
KS1000 LV
Tramline
KS1000 TL
Tramline
KS1000 TL
Euro-Box
KS600-1000 EB
Mini-Micro
KS600-1000 MM
Plank
KS600-1000 PL
Thermal Performance,
Dimensions and Weight
Kingspan KS100
U-value (W/m2K)
R-value (m2K/W)
Core Thickness (mm)
Overall Thickness (mm)
Weight (kg/m2) 0,5 steel /
0,4 steel (AWP)
Weight (kg/m2) 0,63 /
0,63 Steel (Longspan)
Kingspan KS100
U-value (W/m2K)
R-value (m2K/W)
Weight (kg/m2) 0,5 steel /
0,4 steel (AWP)
Weight (kg/m2) 0,63 /
0,63 Steel (Longspan)
Kingspan KS1000 LV
U-value (W/m2K)
R-value (m2K/W)
Weight (kg/m2) 0,5 steel /
0,4 steel (AWP)
Weight (kg/m2) 0,63 /
0,63 Steel (Longspan)
35
0,50
2,08
40
82
9,81

29
0,29
3,44
12,40

33
0,33
3,000
13,00

35
0,50
2,08
40
82
9,81

29
0,29
3,44
12,40

33
0,33
3,000
13,00

30
0,50
2,08
40
82
9,81

26
0,26
3,84
12,80

28
0,28
3,57
13,40

30
0,50
2,08
40
82
9,81

26
0,26
3,84
12,80

28
0,28
3,57
13,40

30
0,50
2,08
40
82
9,81

26
0,26
3,84
12,80

28
0,28
3,57
13,40

AWP
50
0,50
2,08
40
82
9,81

AWP Curvewall
42
0,43
2,32
11,80

AWP Lourve
49
0,49
2,04
12,40

50
0,50
2,08
40
82
9,81

42
0,43
2,32
11,80

49
0,49
2,04
12,40

AWP and Longspan
AWP and Longspan Curvewall
4
AWPand Longspan Lourve
* Tramline, Curvewall and Louvre
are only available in 1000mm
cover widths.
The U-values have been
calculated using the method
required by the appropriate
EN14509 guidelines.
** Longspan panels are only
LPCB approved. Please contact
Kingspan Technical Services for
further information.
*** Please check minimum order
quantities for Curvewall in 140mm
thickness with the Kingspan
Customer Service Team.
† All profiles except Curvewall
and Louvre.
Product Renders
Données Techniques
QuadCore Gamme
Architecturale de Bardage
Convex
KS600-1000 CX
Wave
KS600-1000 WV
Tramline
KS1000 TL
Mini-Micro
KS600-1000 MM
Euro-box
KS600-1000 EB
Micro-Rib
KS600-1000 MR
Plank
KS600-1000 PL
Flat-Stucco
KS600-1000 FL-S
Description
QuadCore Gamme Architecturale de Bardage est une gamme de
panneaux sandwich isolants avec mousse QuadCore Technology à
fixations cachées, ou seule la géométrie du profil extérieur diffère.
QuadCore Gamme Architecturale de Bardage se compose des
panneaux sandwich isolants suivants :
– KS600-1000 MR (Micro-Rib)
– KS600-1000 EB (Euro-Box)
– KS1000 TL (Tramline)
– KS600-1000 PL (Plank)
– KS600-1000 MM (Mini-Micro)
– KS600-1000 CX (Convex)
– KS600-1000 WV (Wave)
– KS600-1000 FL-S (Flat-Stucco)
Application
Ces panneaux sont destinés aux façades de bâtiments de types
industriels et tertiaires, à température positive d’hygrométrie
faible à moyenne. Veuillez nous contacter pour plus d’informations
sur la pose en ERP.
La pose est également possible dans des bâtiments d’hygrométrie
forte ou conditionnés en température, ou en humidité dont la
pression de vapeur est comprise entre 5 et 15 mm Hg.
Pour plus d’informations, veuillez contacter le Service Technique
Kingspan.
Profils
Les géométries des différents profils sont indiquées à la Figure 1.
Parements & Revêtements
Parements en acier de nuance S 220 GD + ZA conformément à la
norme NF EN 10346 et prélaquage suivant la norme NF EN 10169
Les épaisseurs standards sont de 0,60 mm pour le profil extérieur
et 0,40 mm pour le profil intérieur.
Les revêtements prélaqués standards sont les suivants:
Extérieur
– Kingspan Spectrum 55 μm
– Kingspan XL Forté 200 μm
Intérieur
– Kingspan CLEANsafe 15 μm
Pour les coloris, d’autres revêtements et d’autres épaisseurs de
parements, veuillez contacter votre commercial.
Isolant
Mousse QuadCore Technology de couleur grise et de conductivité
thermique λ = 0,018 W/m.K (valeur CE). Une demande de
certification ACERMI est en cours.
Épaisseurs
Les panneaux sandwich isolants QuadCore Gamme Architecturale
de Bardage sont disponibles en épaisseurs 45, 60, 70, 80, 100, 120,
140 et 150 mm.
Largeurs Utiles
À l’exception du panneau KS1000 TL qui est proposé en largeur
utile de 1000 mm, les autres panneaux sandwich isolants
QuadCore Gamme Architecturale de Bardage sont disponibles en
largeurs utiles standards de 600, 900 et 1000 mm.
D’autres largeurs utiles peuvent être également proposées.
Veuillez contacter le service Technique Kingspan pour plus
d’informations.
Longueurs
Les longueurs standards sont de 1,80 à 13,40 m. Pour d’autres
longueurs, veuillez contacter votre commercial.
Tolérances
Les tolérances sont celles définies dans la norme NF EN 14509.
Colisage
Épaisseur Nombre de panneaux par palette > 1,80 m
45 23
60 18
70 15
80 13
100 10
120 8
140 7
150 5
Transport Maritime
Des caisses en bois sont disponibles pour des projets qui exigent
une livraison par bateau. Des conteneurs en acier peuvent être
également proposés. Pour plus d’informations, veuillez consulter
votre commercial.
Produits Associés
Kingspan propose également une gamme de produits associés
afin de proposer un système de toiture à pente complèt, tels
que des accessoires, des couvre-joints, des panneaux d’angles
préfabriqués, des panneaux cintrés et le Kingspan Day-Lite
Architecturale.
Pour plus d’informations, veuillez contacter votre commercial.
Réaction au Feu
Les panneaux sandwich isolants QuadCore Gamme Architecturale
de Bardage bénéficient d’un rapport de classement de réaction au
feu B-s1, d0 (équivalent M1).
Certification & Evaluation
Les panneaux sandwich isolants QuadCore Architecturale de
Bardage sont en cours de certification auprès du leader mondial
de l’assurance dommages aux biens Factory Mutual (FM Global).
La certification ACERMI est en cours.
Performances Acoustiques
Les panneaux sandwich isolants QuadCore Gamme Architecturale
de Bardage possèdent un indice d’affaiblissement acoustique
Rw(C ;Ctr) = 24(-3 ;-4) dB.
Qualité
Les panneaux sandwich isolants QuadCore Gamme Architecturale
de Bardage sont fabriqués dans nos usines qui sont certifiées ISO
9001:2008 (système qualité), ISO 14001:2004 (environnement) et
OHSAS 18001:2007 (santé-sécurité du travail).
Nos usines font également l’objet d’audits réguliers de la part
d’organismes indépendants tels que Factory Mutual et le CSTB.
Qualité Environnementale
QuadCore Gamme Architecturale de Bardage est notée Green
Guide A+ conformément au BRE Global ‘The Green Guide to
Specification’.
Garantie
Kingspan propose une garantie automatique sur la performance
thermique de 10 ans et sur le revêtement Kingspan Spectrum et
Kingspan XL Forté de 15 ans.
Les panneaux sandwich isolants QuadCore Gamme Architecturale
de Bardage propose une garantie structurelle et thermique jusqu'à
40 ans. Veuillez nous consulter pour plus d'informations.
21 Product Insulated Wall Panel Systems Insulated Wall Panel Systems 22
Portfolio
Product
Portfolio
Brochure Internal Grids & Layouts Brochure Internal Grids & Layouts
Brand in Action Brand in Action

100

101
Edition 1.1 August 2017
Edition 1.1 August 2017
Unventilated – Insulation Between & Under Rafters at 600 mm Centres (Recommended for
New Build or Re–roofing)
Figure 1a Figure 1b
Fully Filled Insulation Between Rafters –
No Sarking Board
Fully Filled Insulation Between Rafters –
18 mm Sarking Board
Horizontal lap between
runs of breathable sarking
membrane sealed (if
required) with 75 mm
wide double sided acrylic
adhesive tape
47 mm wide rafters at
600 mm centres
Kingspan Kooltherm® K7
Pitched Roof Board
fully filling space between
rafters
Tiles / slates
Tiles / slate batten
Breathable sarking
membrane e.g.
Kingspan nilvent® 1
38 x 38 mm
counter–batten
3 mm skim coated
Kingspan Kooltherm® K118
Insulated Plasterboard
under rafters 2 3
Horizontal lap between
runs of breathable sarking
membrane sealed (if
required) with 75 mm
wide double sided acrylic
adhesive tape
47 mm wide rafters at
600 mm centres
Kingspan Kooltherm® K7
Pitched Roof Board
fully filling space between
rafters
18 mm sarking board
Natural slates 4
Breathable sarking
membrane e.g.
Kingspan nilvent®
3 mm skim coated
Kingspan Kooltherm® K118
Insulated Plasterboard
under rafters 2 3
U–values (W/m2.K) for Various Thicknesses of Kingspan Kooltherm®
K118 Insulated Plasterboard Assuming Rafters of Depth Shown Fully
Filled with Kingspan Kooltherm® K7 Pitched Roof Board
Rafter Depth
(mm)
Product Thickness of Kingspan Kooltherm®
K118 Insulated Plasterboard* (mm)
32.5 57.5 72.5
100 0.20 0.15 0.13
125 0.17 0.13 0.12
150 0.15 0.12 0.11
U–values (W/m2.K) for Various Thicknesses of Kingspan Kooltherm®
K118 Insulated Plasterboard Assuming Rafters of Depth Shown Fully
Filled with Kingspan Kooltherm® K7 Pitched Roof Board
Rafter Depth
(mm)
Product Thickness of Kingspan Kooltherm®
K118 Insulated Plasterboard* (mm)
32.5 57.5 72.5
100 0.19 0.15 0.13
125 0.16 0.13 0.12
150 0.14 0.12 0.11
* Product thickness = insulant thickness + 12.5 mm plasterboard.
NB Refer to local distributor or Kingspan Insulation price list for current stock and non–stock
sizes.
* Product thickness = insulant thickness + 12.5 mm plasterboard.
NB Refer to local distributor or Kingspan Insulation price list for current stock and non–stock
sizes.
6
Double page spread example
Typical Constructions and U–values
Assumptions
The U−values in the tables that follow
have been calculated, under a
management system certified to the BBA
Scheme for Assessing the Competency
of Persons to Undertake U–value and
Condensation Risk Calculations, using the method detailed in
BS / I.S. EN ISO 6946: 2007 (Building components and building
elements. Thermal resistance and thermal transmittance.
Calculation method), and using the conventions set out in
BR 443 (Conventions for U−value calculations). They are valid
for the constructions shown in the details immediately above
each table.
U−value tables for pitched roofs with rafters at different centres
than those specified can be found on the Kingspan Insulation
website (see rear cover for details).
NB Calculations assume that the insulation core of Kingspan Kooltherm® K118 Insulated
Plasterboard has a thermal conductivity of 0.018 W/m.K.
NB When calculating U–values to BS / I.S. EN ISO 6946: 2007, the type of mechanical fixing
used may change the thickness of insulation required. The effect of fixings for Kingspan
Kooltherm® K118 Insulated Plasterboard in the U–value calculations for Figures 1a, 1b, 1c, 1d,
2a, 2b, 4a & 4c is insignificant as the insulation layer penetrated is not the main insulation
layer. Please see Figures 3a & 3b for details of appropriate fixing assumptions. Please
contact the Kingspan Insulation Technical Service Department (see rear cover) for project
calculations.
NB For the purposes of these calculations the standard of workmanship has been assumed
good, and therefore the correction factor for air gaps has been ignored.
NB The figures quoted are for guidance only. A detailed U–value calculation and a
condensation risk analysis should be completed for each project.
NB If your construction is different from those specified, and / or to gain a comprehensive
U−value calculation along with a condensation risk analysis of your project, please consult
the Kingspan Insulation Technical Service Department for assistance (see rear cover).
Image Key
1 In Figures 1a & 3a the breathable sarking membrane can
be placed over the counter–battens, draped to provide for
drainage and overlain with tile / slate battens. This will yield
a marginally better U–value but it will be more difficult to
seal the breathable sarking membrane effectively.
2 T h e requirement for a vapour control layer and / or under tile
ventilation should be assessed to BS 5250: 2002.
Vapour check plasterboard or a separate vapour control
layer can be used as preferred (see ‘Design Considerations –
Vapour Control Layer’).
3 Kingspan Kooltherm® K118 Insulated Plasterboard contains an
integral vapour control layer (see ‘Design Considerations
– Vapour Control Layer’).
4 If tiles are to be used then this normally necessitates the
use of counter–battens and tiling battens over the
breathable sarking membrane to allow for water drainage
and attachment of the tiles.
U–value Table Key
Where an ✖ is shown, the U–value is higher than the worst
of the maximum new build area weighted average U–values
allowed by the:
– 2013 editions of Approved Documents L to the Building
Regulations for England;
– 2014 editions of Approved Documents L to the Building
Regulations for Wales;
– 2015 editions of Technical Handbooks Section 6 to the
Building Standards for Scotland;
– 2012 editions of Technical Booklets F1 & F2 to the Building
Regulations for Northern Ireland; and
– 2011 edition of Technical Guidance Document L (Dwellings)
and 2008 edition of Technical Guidance Document L
(Buildings other than Dwellings) to the Building Regulations
for the Republic of Ireland.
Where an is shown, the combination of insulation products
may result in an interstitial condensation risk and so the
calculations have been excluded.
U Value Competency Scheme
CERTIFICATE CS/1004-2
5
Main Page Title
x: 20mm
y: 23.7mm
Line Weight: 0.3pt
Line Offset: 10mm
Grid Position
Aligned with left grid rectangle and set
at 23.7mm vertically to allow for line above
to vertically align with the 1st grid rectangle.
Line length to suit layout.
Main Column Headings
x: 20mm
y: 54.8mm
Line Weight: 0.3pt
Line Offset: 7mm
Grid Position
Aligned with left grid rectangle and set
at 54.8mm vertically to allow for line above
to vertically align with the 3rd grid rectangle.
Line length to fit column width.
Page Folio (left)
x: 20mm
y: 286mm
Line Weight: 0.3pt
Line Offset: 3.5mm
Line Width: 4mm
Page Folio (right)
x: 186mm
y: 286mm
Line Weight: 0.3pt
Line Offset: 3.5mm
Line Width: 4mm
Internal Grids
Brochure Internal Grids & Layouts
Brand in Action Brand in Action

102

103
Edition 1.1 August 2017
Edition 1.1 August 2017
Double page spread example
- Typeface Hierachy
9
Unventilated Roof – Ventilation Considerations
Unventilated roof approaches create a warm pitched roof space
which does not require cross ventilation. Research suggests that
sealing an unventilated roof yields a more energy efficient roof,
as the impacts of ventilation and incidental infiltrating cold air
can be minimised. Therefore, if creating an unventilated roof,
it is preferable to fully seal all joints in the breathable sarking
membrane (see ‘Position of Breathable Sarking Membrane’
below). Any water vapour reaching the breathable sarking
membrane escapes without condensing. There is then adequate
air movement beneath the tiles to dissipate this water vapour to
the outside atmosphere. Tape for sealing joints in the breathable
sarking membrane should be specified in accordance with the
recommendations of the breathable membrane manufacturer.
The requirement for a vapour control layer and / or under–tile
ventilation should be assessed to BS 5250: 2011 (Code of practice
for control of condensation in buildings).
Ventilated Roof – Ventilation Considerations
In these cases the Building Regulations / Standards require a
50 mm ventilation air gap between the insulation and the
sarking felt, so as to avoid condensation.
The requirement for a vapour control layer should be assessed
to BS 5250: 2011.
Vapour Control Layer
If required, the vapour resistance of the roof lining can be
increased by the use of a vapour check plasterboard*, the use
of Kingspan Kooltherm® K118 Insulated Plasterboard, which
contains an integral vapour control layer*, the use of a layer
of polythene sheeting*, or by the application of two coats of
Gyproc Drywall Sealer.
* With appropriate detailing at joints, penetrations and roof perimeters.
Breathable Sarking Membrane
BS 5250: 2011 recommends that low resistance breathable
sarking membranes for use in unventilated systems must
not have a vapour resistance that exceeds 0.25 MN.s/g,
e.g. Kingspan nilvent®.
In roofs with no continuous surface (Figure 1c), it is preferable,
though more difficult, to install the breathable sarking
membrane in vertical runs with junctions between runs sealed
by counter–battens placed over the laps in rafter positions.
The breathable sarking membrane is installed taut as the
counter–batten provides a space for water drainage.
Recommended Solutions for New Build / Re–roofing
The ideal solution for new build or re–roofing projects is,
therefore, between and under rafter insulation with a
continuous surface for the breathable sarking membrane so
that it can be installed in horizontal runs under counter–battens
with laps sealed with tape (Figures 1a, 1b & 1d).
The next best solution is, therefore, between and under rafter
insulation with no continuous surface for the breathable sarking
membrane, and the breathable sarking membrane installed in
vertical runs with laps sealed under counter–battens (Figure 1c).
Where very low U–values are required, for new build or re–
roofing projects, the ideal solution is between and over rafter
insulation with the breathable sarking membrane installed in
horizontal runs under counter battens with laps sealed with
tape (Figures 3a & 3b).
Insulating at Ceiling Level – Choice of Build Up
When insulating at ceiling level in a pitched roof with loft
insulation between and over joists (Figures 4b, 8a & 8b) it is vital
to ensure the continuity of insulation at the specified R−value
right to the eaves. This can be difficult because of the angle of
pitch of the roof and the position of the rafters can prevent the
insulation laid over the joists from being fitted all the
way to the eaves. The use of Kingspan Kooltherm® K7 Pitched
Roof Board in between joists and Kingspan Kooltherm® K118
Insulated Plasterboard below joists (Figures 4c, 9a & 9b) allows
continuity of insulation and can minimise heat loss from this
linear thermal bridge.
Mansard Roofs / Walls
Kingspan Kooltherm® K7 Pitched Roof Board can be
used for the construction of insulated tiled or slated mansard
roofs / walls. Design and installation guidance is as for
pitched roofs.
Fire Stops
Current Building Regulations / Standards should be considered
with regard to the requirements for, and provision of, fire stops.
Design Considerations
10
Ridge flashing with 150mm sealed butt straps Site applied fire rated canister insulation
KS1000 RW/LPCB insulated roof panel
Internal ridge flashing with 150mm overlap sealed with
6x4mm butyl tape or gun-grade sealant
Self-drilling self-tapping primary fixings with minimum
19mm diameter non-ferrous EPDM backed washer
Stitching screws with minimum 14mm diameter non-ferrous
EPDM backed washer fitted at every crown
Profiles filler sealed top & bottom with gun-grade
sealant (profiles filler set back 80-100mm)
Gun-grade seal at panel joint inline
with internal air seal
Air seal - 6mm diameter butyl rubber sealant
Construction Details
QuadCore Trapezoidal KS1000 RW: Ridge Detail
New Column Body Copy Heading
x: 107mm
y: 23.7mm
Line Weight: 0.3pt
Line Offset: 6.75mm
Grid Position
Aligned left with grid rectangle and set
at 54.8mm vertically to allow for line above
to vertically align with the 3rd grid rectangle.
Line length to fit column width.
New Column Body Copy Only
x: 20mm
y: 54.8mm
Line Weight: 0.3pt
Line Offset: 6.2mm
Grid Position
Aligned with left grid rectangle and set
at 54.8mm vertically to allow for line above
to vertically align with the 3rd grid rectangle.
Line length to fit column width.
Page Folio (left)
x: 20mm
y: 286mm
Line Weight: 0.3pt
Line Offset: 3.5mm
Line Width: 4mm
Page Folio (right)
x: 186mm
y: 286mm
Line Weight: 0.3pt
Line Offset: 3.5mm
Line Width: 4mm
Internal Grids
Brochure Internal Grids & Layouts
Brand in Action Brand in Action

104

105
Edition 1.1 August 2017 Edition 1.1 August 2017
Business Cards
Brand in Action Brand in Action

106

107
Edition 1.1 August 2017 Edition 1.1 August 2017
Business Cards
Name / Surname
Job Title
Business Unit or Division
E: name.surname@kingspan.com
M: +00 (0) 0000 000 000
T: +00 (0) 0000 000 000
F: +00 (0) 0000 000 000
Web url
Address Title
Address Line 1
Address Line 2
Address Line 3
Name/Surname
Typeface: Kingspan Brown Bold
Size: 10pt
Colour: CMYK: 65/57/52/68
Job Title
Typeface: Kingspan Brown Light
Size: 8pt
Colour: CMYK: 65/57/52/68
Division
Typeface: Kingspan Brown Light
Size: 6pt
Colour: CMYK: 33/28/26/34
Contacts/URL
Typeface: Kingspan Brown Light
Size: 6.5pt
Colour: CMYK: 65/57/52/68
Address
Typeface: Kingspan Brown Light
Size: 6.5pt
Colour: CMYK: 33/28/26/34
Business Card: Front
® Kingspan and the Lion Device are Registered Trademarks of the Kingspan Group plc
in the UK, Ireland and other countries. A Trademarks/Rights ll rights reserved.
Typeface: Kingspan Brown Light
Size: 5.5pt
Colour: CMYK: 65/57/52/68
Business Card:

S-ar putea să vă placă și