Sunteți pe pagina 1din 9

Case: D:\TITIP\B3\WORK\Process Simulation\LPG DEPOT DUMAI Case 3,hsc

Flowsheet:Main
Current Flowsheet Environment:
Main
Unit ( 1 ) Unloading ( 5 ) Vapor Return to Tanker ( 3 ) To TLA ( 2 ) P2

Vapour Fraction 0 1 0 0
Temperature C 38.00 27.61 27.97 27.61
Pressure kg/cm2 8.19 6.19 10.01 6.19
Mass Flow tonne/h 350.00 28.54 78.11 78.11
Liquid Volume Flowm3/h 645.64 53.68 143.85 143.85
Mass Density kg/m3 512.84 13.89 528.93 528.53
Viscosity cP 0.12 0.01 0.14 0.14
se Comp Mole Frac (Overall-n-Butane) 0.60 0.41 0.62 0.62
se Comp Mole Frac (Overall-Propane) 0.40 0.59 0.38 0.38
( 4 ) Vapor Return To Tank

1
26.58
6.01
0.83
1.56
13.50
0.01
0.41
0.59
Unit ( 1 ) (Unloading
5 ) Vapor Return to Tanker
V3 TANK OUTLET V1 s2 l3 1

Comp Mole Frac (n-Butane) 0 0 0.2 0 0.2 0.2 <empty> 0.2


Comp Mole Frac (Propane) 0.4 0.589659 0.8 0.382179 0.8 0.8 <empty> 0.8
Comp Mole Frac (Air) 0 0 0 0 0 0 <empty> 0
Comp Mole Frac (H2O) 0 0 0 0 0 0 <empty> 0
Comp Mole Frac (i-Butane) 0.6 0.410341 0 0.617821 0 0 <empty> 0
3 air out L1 Cooling Spray L1-2 To Tank Kapal To Tank-2 Kapal-2 To Tank-3

0 0 0.4 0 0 0.5 0.5 0.4 0.4 0.6


0 0 0.6 0 0 0.5 0.5 0.6 0.6 0.4
1 1 0 0 0 0 0 0 0 0
0 0 0 1 1 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
Kapal-3 P3 TLA 2 P1 TLA 2-2 ( 3 ) To TLA ( 2 ) P2 V( 4truk
) Vapor Return To
toTank
v tank

0.6 0 0 0 0 0 0 <empty> 0 <empty>


0.4 0.382179 0.382179 0.382179 0.382179 0.382179 0.382179 <empty> 0.588831 <empty>
0 0 0 0 0 0 0 <empty> 0 <empty>
0 0 0 0 0 0 0 <empty> 0 <empty>
0 0.617821 0.617821 0.617821 0.617821 0.617821 0.617821 <empty> 0.411169 <empty>
cooler 3 P4 2 4 LPG Filling Shed

<empty> 0 0 0.4 0
<empty> 0.382179 0.6 0.6 0.379827
<empty> 0 0 0 0
<empty> 0 0 0 0
<empty> 0.617821 0.4 0 0.620173
Unit Qc Q comp QP1-2 QP1-3 QP1-3-2 QP1-3-3 QP2 QP2-2

Heat Flow Btu/hr 190997.6 28661.01 730942.7 93692.77 94061.16 93486.66 170242.3 170242.3
QP1 Q cooler Q comp 2

69985.05 20 <empty>

S-ar putea să vă placă și