Application wizard
Industry Pure power plant (PP)
Process Id Power/Boiler dual pressure reheat with water condensor (222112)
Application HP to Cold Reheat (L)
PowerSIZ 1.6S
Technical Specification.
Steam conditioning valve equipment. Page 2/3
Date / Rev. / User Id : 2010-09-09 / D / Lindberg, Marcus
Customer : CETHAR VESSELS LIMITED
Project : VANDANA VIDYUT LTD
PO. No. LOI MBJ013/014/HP-LP
Reference No. 301912.10 A/B
Tag No. 01/02MAN40-AA201
No. of valves 2
Application wizard
Industry Pure power plant (PP)
Process Id Power/Boiler dual pressure reheat with water condensor (222112)
Application HP to Cold Reheat (L)
PowerSIZ 1.6S
Selected CCI Steam conditioning equipment.
Reference No. 301912.10 A/B Page 3/3
Date / Rev. / User Id : 2010-09-09 / D / Lindberg, Marcus
PowerSIZ 1.6S
Sound Pressure Level (SPL) Prediction - IEC 60534-8-3
Control Valve - Noise Aspects
Date / Rev. / User Id : 2010-09-09 / D / Lindberg, Marcus
Reference No. 301912.10 A/B
Customer : CETHAR VESSELS LIMITED Tag No. 1-HPBP
Project : VANDANA VIDYUT LTD Valve type VLB - 100BTC
1. The room where the valves are installed shall have a reverberation time of 1 second or less.
2. Straight pipe upstream the valve inlet stud L1 ≥ 3 x DN1, min 1 m.
Straight pipe downstream the valve outlet stud L2 > 6 x DN2, min 4 m.
Upstream stop valve, of type gate or globe, not closer than 3 m.
Downstream stop valve not closer than 8 m.
No studs for safety valve connection within 3 m upstream and 8 m downstream.
No T-pieces or flow orifices within the same area.
Pipe support devices such as fixpoints and pipe hangers to be insulated from the building floor
and steel structure via noise barriers.
3. Flow velocities should be within CCI's recommendations. Pipe wall thickness,
especially on the outlet pipe should be acc. to CCI's recommendations.
4. Good insulation preferably a multilayer type. First a thermal insulation, then a noise attenuation insulation
upon the first layer. The second layer should be applied from approximately 3 m upstream of the valve itself,
and approximately 6 m downstream of the valve outlet end.
5. Measuring Instrument according to IEC-651. Measuring to ISO 9614-2.
If it is uncertain from which areas or parts excessive noise is emited, a sound intensity (power)
measuring instrument should be used to detect the noise sources.
Example of an instrument is Brüel & Kjær type 2260+BZ7205.
6. Corrections to be made for background noise.
CCI Noise prediction
The CCI noise prediction only relates to the noise generated by our equipment. CCI will not be responsible
for noise generated by upstream/downstream devices, expansion joints in piping or other noise sources
in the plant. All predictions are made assuming only one valve in operation and assuming no reflection of noise
from surrounding surfaces. For systems dumping to condenser the noise generated by the dump tube
system is not accounted for in the above valve noise prediction. If requested separate predictions can be
provided for this equipment on best effort basis.
PowerSIZ 1.6S
E 2011-01-05 Revised Tag no KJ.Ahn
D 2010-12-10 Revised design pressure and pipe thickness KJ.Ahn
C 2010-10-07 Design confirmed by sub supplier C.H.P
B 2010-09-20 Added end prep LgM
A 2010-09-14 1:st issue LgM
LgM 2010-09-14
Technical Specification for
CHECKED BY DATE
HP to CRH Bypass TCV
Tag no: 3-HPBP WIV 1/2
ÖHM 2010-09-16 DOCUMENT NUMBER: V301912.20 A/B/C/D
CONTROL VALVE DATA SHEET
Project Vandana Vidyut Ltd Tag # 01/02MAN07-AA201
Buyer Cethar Vessels Limited Item # 20
Owner Qty. 2
Inq. Rev. Date Model 100DSV
Prop. Rev. Date D-SHT Rev. C Dwg # S1179506
P.O. Application HP to CRH Bypass TCV
1 Fluid Water/Steam Crit Press 226 kg/cm2 A Crit Temp 374.2 deg C
Units 60%TMCR 60%VWO 60%BMCR TG IN40% CRH60%TMCR
2 Mass Flow Rate kg/h 40558 42426 43084 27635 45982
3 Inlet Pressure (P1) kg/cm2 A 200.99 200.94 200.94 201.27 200.86
4 Outlet Pressure (P2) kg/cm2 A 35.78 37.96 34.32 17.03 26.1
5 Differential (P) kg/cm2 165.2 163.0 166.6 184.2 174.8
6 Inlet Temp. (T1) deg C 167.3 170.0 140.0 135.3 148.3
7 Density kg/m3 911.5 908.9 936.3 940.3 929.0
8 Vapor Pressure kg/cm2 A 7.563 8.077 3.686 3.222 4.638
9 Viscosity cpoise 0.1670 0.1642 0.2014 0.2089 0.1895
10 Required Flow Cv 3.975 4.192 4.148 2.525 4.34
11 Travel % Stroke 87.9 91.2 90.5 66.2 93.4
12 SPL dBA 75.0 75.0 75.0 75.0 75.0
13 Pipe In OD 88.9 THK 11.13 mm 38 Actuator Type Electro hydraulic
14 Pipe Out OD 88.9 THK 11.13 mm 39 Mfr / Model EHCP 040/20-50 VCN
15 Pipe Matl In SA-106 Out SA-106 40 Failure Mode Fail Close
16 Type Globe Size 80 X 80 mm 41 Supply Type Hydraulic oil
17 Design P In 250 Out 250 kg/cm2 G 42 Supply (Min/Max) 150.0 / 170 kg/cm2g
18 Design T In 260.0 Out 260.0 deg C 43 Shut-off Differential 250 kg/cm2
19 Rating(s) In ASME 2500 Out ASME 2500 44 Stem Orientation Vertical Up
20 Material WCC / A105 45 Manual Override N/A
21 Connect In Butt Weld BJ013-00-47-101 Style D 46 N/A
22 Connect Out Butt Weld BJ013-00-47-101 Style D 47 Positioner Type Electro hydraulic
23 Flow Dir. Flow to Close (OTP) 48 Mfr / Model STI / SmartTrak
24 Bonnet Type Bolted 49 Input Signal 4-20 mA
25 Bonnet Seal Gasket 50 Increasing Signal Valve open
26 Packing Type Chevron 51 Cam Characteristic N/A
27 Packing Matl Teflon 52 Housing N/A
28 Trim Type Dragٛ, Multi-Path, Multi-Stage 53 Filter (Filter Reg) N/A
29 Trim Size 25.4 mm Rated Cv 4.78 54 Limit/Torque Switch Open / Close
30 Trim Char. Characterized 55 Position Feedback Integrated
31 Number of Pressure Reducing Stages Min 12 Stages 56 I - P Transducer N/A
32 Plug Type Balanced 57 Solenoid Valve(s) N/A
33 Stem Matl 17-4PH H900 58 Elect Housing STD Standard
34 Plug Matl 17-4PH H900 59 Seat Leakage MSS-SP 61
35 Seat Matl 300 Series 60 Open Time(s) < 3.0 sec QO < 3.0 sec
36 Guide Matl 400 Series, HT 61 Close Time(s) < 3.0 sec QC < 3.0 sec
37 62 Approx. Weight 45 kgs (Valve only)
Notes / Special Instructions
63 For easy maintenance, the trim is a quick change type. No components are screwed or welded to the body or bonnet.
64 Valve design to ASME B16.34, latest edition.
65 Hardware capacity shown above assumes 10% over capacity margin
66 IBR certification is required
67
68
69
70
71
72
73
74
75
VALSIZ® Version 8.4i (Printed 5-01-11, 8:14 AM)
E 2011-01-05 Changed tag no KJ.Ahn
D 2010-12-10 Changed design P KJ.Ahn
C 2010-10-07 Design confirmed by sub supplier EH.Lee
B 2010-09-20 Added end prep LgM
A 2010-09-14 1:st issue LgM
14 Pipe Out 3" Sch 160 39 Mfr / Model EHC 050/25-100 VCN
15 Pipe Matl In SA-106 Out SA-106 40 Failure Mode Valve Close
ACTUATOR
16 Type GLOBE Size 3" (80A) 41 Supply Type Hydraulic Oil
17 Design P In 250 Out 250 kg/cm2g 42 Avail. Supply (Min) 150 kg/cm2g
VALVE BODY / BONNET
18 Design T In 260 Out 260 deg C 43 Avail. Supply (Max) 170 kg/cm2g
19 Rating(s) In ASME 2500# Out ASME 2500# 44 Stem Orientation Vertical Up
20 Material A216 WCB 45 Manual Override N/A
21 Connect In ASME 2500# BW Same as Body 46 Shut-off pressure 250 kg/cm2
22 Connect Out ASME 2500# BW Same as Body 47 Positioner Type N/A
POSITIONER
Application wizard
Industry Pure power plant (PP)
Process Id Power/Boiler dual pressure reheat with water condensor (222112)
Application LP Bypass to condenser (R)
1
Temperature increased to be above saturation
PowerSIZ 1.6S
Technical Specification.
Steam conditioning valve equipment. Page 2/3
Date / Rev. / User Id : 2010-09-14 / E / Lindberg, Marcus
Customer : CETHAR VESSELS LIMITED
Project : VANDANA VIDYUT LTD
PO. No. LOI MBJ013/014/HP-LP
Reference No. 301912.40 A/B
Tag No. 01/02MAN12-AA201
No. of valves 2
Application wizard
Industry Pure power plant (PP)
Process Id Power/Boiler dual pressure reheat with water condensor (222112)
Application LP Bypass to condenser (R)
PowerSIZ 1.6S
Selected CCI Steam conditioning equipment.
Reference No. 301912.40 A/B Page 3/3
Date / Rev. / User Id : 2010-09-14 / E / Lindberg, Marcus
PowerSIZ 1.6S
Sound Pressure Level (SPL) Prediction - IEC 60534-8-3
Control Valve - Noise Aspects
Date / Rev. / User Id : 2010-09-14 / E / Lindberg, Marcus
Reference No. 301912.40 A/B
Customer : CETHAR VESSELS LIMITED Tag No. 4-LP BP 1/2
Project : VANDANA VIDYUT LTD Valve type VLB - 225BTC
1. The room where the valves are installed shall have a reverberation time of 1 second or less.
2. Straight pipe upstream the valve inlet stud L1 ≥ 3 x DN1, min 1 m.
Straight pipe downstream the valve outlet stud L2 > 6 x DN2, min 4 m.
Upstream stop valve, of type gate or globe, not closer than 3 m.
Downstream stop valve not closer than 8 m.
No studs for safety valve connection within 3 m upstream and 8 m downstream.
No T-pieces or flow orifices within the same area.
Pipe support devices such as fixpoints and pipe hangers to be insulated from the building floor
and steel structure via noise barriers.
3. Flow velocities should be within CCI's recommendations. Pipe wall thickness,
especially on the outlet pipe should be acc. to CCI's recommendations.
4. Good insulation preferably a multilayer type. First a thermal insulation, then a noise attenuation insulation
upon the first layer. The second layer should be applied from approximately 3 m upstream of the valve itself,
and approximately 6 m downstream of the valve outlet end.
5. Measuring Instrument according to IEC-651. Measuring to ISO 9614-2.
If it is uncertain from which areas or parts excessive noise is emited, a sound intensity (power)
measuring instrument should be used to detect the noise sources.
Example of an instrument is Brüel & Kjær type 2260+BZ7205.
6. Corrections to be made for background noise.
CCI Noise prediction
The CCI noise prediction only relates to the noise generated by our equipment. CCI will not be responsible
for noise generated by upstream/downstream devices, expansion joints in piping or other noise sources
in the plant. All predictions are made assuming only one valve in operation and assuming no reflection of noise
from surrounding surfaces. For systems dumping to condenser the noise generated by the dump tube
system is not accounted for in the above valve noise prediction. If requested separate predictions can be
provided for this equipment on best effort basis.
PowerSIZ 1.6S
C 2011-04-15 Changed item & tag numbers LgM
Application wizard
Industry Pure power plant (PP)
Process Id Power/Boiler dual pressure reheat with water condensor (222112)
Application LP Bypass to condenser (R)
1
Temperature increased to be above saturation
PowerSIZ 1.6S
Technical Specification.
Steam conditioning valve equipment. Page 2/3
Date / Rev. / User Id : 2010-09-14 / C / Lindberg, Marcus
Customer : CETHAR VESSELS LIMITED
Project : VANDANA VIDYUT LTD
PO. No. LOI MBJ013/014/HP-LP
Reference No. 301912.45 A/B
Tag No. 01/02MAN11-AA201
No. of valves 2
Application wizard
Industry Pure power plant (PP)
Process Id Power/Boiler dual pressure reheat with water condensor (222112)
Application LP Bypass to condenser (R)
PowerSIZ 1.6S
Selected CCI Steam conditioning equipment.
Reference No. 301912.45 A/B Page 3/3
Date / Rev. / User Id : 2010-09-14 / C / Lindberg, Marcus
PowerSIZ 1.6S
Sound Pressure Level (SPL) Prediction - IEC 60534-8-3
Control Valve - Noise Aspects
Date / Rev. / User Id : 2010-09-14 / C / Lindberg, Marcus
Reference No. 301912.45 A/B
Customer : CETHAR VESSELS LIMITED Tag No. 4-LP BP 1/2
Project : VANDANA VIDYUT LTD Valve type VLB - 225BTC
1. The room where the valves are installed shall have a reverberation time of 1 second or less.
2. Straight pipe upstream the valve inlet stud L1 ≥ 3 x DN1, min 1 m.
Straight pipe downstream the valve outlet stud L2 > 6 x DN2, min 4 m.
Upstream stop valve, of type gate or globe, not closer than 3 m.
Downstream stop valve not closer than 8 m.
No studs for safety valve connection within 3 m upstream and 8 m downstream.
No T-pieces or flow orifices within the same area.
Pipe support devices such as fixpoints and pipe hangers to be insulated from the building floor
and steel structure via noise barriers.
3. Flow velocities should be within CCI's recommendations. Pipe wall thickness,
especially on the outlet pipe should be acc. to CCI's recommendations.
4. Good insulation preferably a multilayer type. First a thermal insulation, then a noise attenuation insulation
upon the first layer. The second layer should be applied from approximately 3 m upstream of the valve itself,
and approximately 6 m downstream of the valve outlet end.
5. Measuring Instrument according to IEC-651. Measuring to ISO 9614-2.
If it is uncertain from which areas or parts excessive noise is emited, a sound intensity (power)
measuring instrument should be used to detect the noise sources.
Example of an instrument is Brüel & Kjær type 2260+BZ7205.
6. Corrections to be made for background noise.
CCI Noise prediction
The CCI noise prediction only relates to the noise generated by our equipment. CCI will not be responsible
for noise generated by upstream/downstream devices, expansion joints in piping or other noise sources
in the plant. All predictions are made assuming only one valve in operation and assuming no reflection of noise
from surrounding surfaces. For systems dumping to condenser the noise generated by the dump tube
system is not accounted for in the above valve noise prediction. If requested separate predictions can be
provided for this equipment on best effort basis.
PowerSIZ 1.6S
E 2011-01-05 Changed tag no KJ.Ahn
D 2010-12-10 Changed connection size design P KJ.Ahn
C 2010-10-07 Design confirmed by sub supplier C.H.P
B 2010-09-20 Added end prep LgM
A 2010-09-14 1:st issue LgM
LgM 2010-09-14
Technical Specification for
CHECKED BY DATE
LP Bypass to Condenser TCV
Tag no: 5-LP BP WIV 1/2/3/4
ÖHM 2010-09-16 DOCUMENT NUMBER: V301912.50 A/B/C/D
CONTROL VALVE DATA SHEET
Project Vandana Vidyut Ltd Tag # 01/02MAN15/16-AA201
Customer Cethar Vessels Limited Item # 50
Ult. Client Qty. 4
Inq. Rev. Date Model 840H
Prop. Rev. Date D-SHT Rev. 2 Dwg # S1179530
Serial # A66903-01~04 Application LP Bypass to Condenser TCV
1 Fluid LIQUID Crit Pressure 225 kg/cm2a Crit Temp deg C
Units 60%TMCR 60%VWO 60%BMCR TG IN40% CRH 60% TMCR
2 Flow Rate kg/hr 46236.5 48597.9 49673.0 32308 50674.1
SERVICE CONDITIONS